A new 14.5 GHz Electron Cyclotron Resonance (ECR) ion source has been constructed over the last two years. The source was designed and tested by making use of the latest results from ECR ion source development, such a...A new 14.5 GHz Electron Cyclotron Resonance (ECR) ion source has been constructed over the last two years. The source was designed and tested by making use of the latest results from ECR ion source development, such as high mirror magnetic field, large plasma volume, and biased probe. 140uA of O^7+, 185uA of Ar^11+ and 50uA of Xe^26+ could be produced with a RF power of 800 W. The intense beams of highly charged metallic ions are produced by means of the method of a metal evaporation oven and volatile compound through axial access. The test results are 130uA of Ca^11+, 70uA of Ca^12+ and 65uA of Fe^lo+. The ion source has been put into operation for the cyclotron at the institute of Modern Physics (IMP).展开更多
Fe K-shell ionization cross sections induced by 2.4-6.0 MeV Xe^20+ are measured and compared with different binary- encounter-approximation (BEA) models. The results indicate that the BEA model corrected both by th...Fe K-shell ionization cross sections induced by 2.4-6.0 MeV Xe^20+ are measured and compared with different binary- encounter-approximation (BEA) models. The results indicate that the BEA model corrected both by the Coulomb repulsion and by the effective nuclear charge (Zeff) agrees well with the experimental data. Comparison of Fe K-shell X-ray emission induced by 5 MeV xenon ions with different initial charge states (20+, 22+, 26+, 30+) verifies the applicability of the effective nuclear charge (Zeff) correction for the BEA model. It is found that Zeff correction is reasonable to describe direct ionization induced by xenon ions with no initial M-shell vacancies. However, when the M shell is opened, the Zeff corrected BEA model is unable to explain the inner-shell ionization, and the electron transfer by molecular-orbital promotion should be considered.展开更多
This paper describes a long-term operation of the 2.45-GHz microwave proton source at Peking University. The DC proton beam of 50–55 mA with energy of 35 keV has been run for 306 hours continuously. Total beam availa...This paper describes a long-term operation of the 2.45-GHz microwave proton source at Peking University. The DC proton beam of 50–55 mA with energy of 35 keV has been run for 306 hours continuously. Total beam availability,defined as 35-keV beam-on time divided by elapsed time, is higher than 99%. Water cooling machine failures cause all the downtime, and no plasma generator failure or high voltage breakdown is observed. The longest uninterrupted run time is122 hours.展开更多
Charge breeding technique is used for RIB (radioactive ion beam) production in order of optimizing the re-acceleration of the radioactive isotopes produced by a primary beam in a thick target. Charge breeding is ach...Charge breeding technique is used for RIB (radioactive ion beam) production in order of optimizing the re-acceleration of the radioactive isotopes produced by a primary beam in a thick target. Charge breeding is achieved by means of a device capable of increasing the ion charge state from 1+ to a desired value n+. In some experiments, a continuous RIB of a given energy may be required. To reach this goal, a charge breeding device based on a hollow gun EBIS (electron beam ion source) has been proposed by the author recently. That EBIS, in principle, can be capable to realize a CW (continuous wave) operation. A sufficiently high focusing magnetic field could reduce to zero the hole radius in the EBIS electron beam. However, a smaller efficiency in the ion charge state increase should be expected. A code developed for studying the ion selective containment in a EBIS has been modified and used to simulate the ion charge state breeding. The effects of the hollow electron beam on the breeding rate have been studied.展开更多
研制了一台体积和重量都较大、设计性能较高的全永磁电子回旋共振(Electron cyclotron resonance, ECR)离子源LAPECR2(Lanzhou all permanent magnetic ECR ion source No.2)。该离子源将用于中国科学院近代物理研究所320 kV高压平台,...研制了一台体积和重量都较大、设计性能较高的全永磁电子回旋共振(Electron cyclotron resonance, ECR)离子源LAPECR2(Lanzhou all permanent magnetic ECR ion source No.2)。该离子源将用于中国科学院近代物理研究所320 kV高压平台,为其提供强流高电荷态离子束流。LAPECR2的研制采用全新的全永磁磁体结构设计,通过采用高性能的NdFeB永磁材料、优化的磁结构设计以及精确的计算,实测源体的磁场参数能达到高性能ECR离子源的设计要求。离子源采用较高频率的14.5 GHz微波馈入加热等离子体,波导直接馈入离子源以增强馈入微波的稳定性与效率。此外,还大量采用了一些有利于提高离子源高电荷态离子产额的关键技术,如铝内衬等离子体弧腔、负偏压盘、铝制等离子体电极、三电极引出系统、辅助掺气等。展开更多
为满足兰州重离子加速器的实验要求,先后在中国科学院近代物理研究所14.5GHz(LECR2)及10GHz+14.5GHz(LECR3)高电荷态ECR离子源上使用MIVOC(Metallic ion fromvolatile compounds)方法进行了高电荷态金属离子产生的实验研究。主要研究了...为满足兰州重离子加速器的实验要求,先后在中国科学院近代物理研究所14.5GHz(LECR2)及10GHz+14.5GHz(LECR3)高电荷态ECR离子源上使用MIVOC(Metallic ion fromvolatile compounds)方法进行了高电荷态金属离子产生的实验研究。主要研究了铁和镍的各种高电荷态离子的产生,具有代表性的是210eμA的Fe11+、175eμA的Fe12+、142eμA的Fe13+、25eμA的Fe16+、64eμA的Ni10+、57eμA的Ni13+、31eμA的Ni15+和15eμA的Ni16+。本文将分别给出两种金属离子产生的多电荷态束流谱图,并对实验装置的安排、实验现象及结果进行讨论与总结。展开更多
A Superconducting ECR ion source with Advanced design in Lanzhou (SECRAL) was successfully built to produce intense beams of highly charged ions for Heavy Ion Research Facility in Lanzhou (HIRFL).The ion source has be...A Superconducting ECR ion source with Advanced design in Lanzhou (SECRAL) was successfully built to produce intense beams of highly charged ions for Heavy Ion Research Facility in Lanzhou (HIRFL).The ion source has been optimized to be operated at 28GHz for its maximum performance.The superconducting magnet confinement configuration of the ion source consists of three axial solenoid coils and six sextupole coils with a cold iron structure as field booster and clamping.For 28GHz operation,the magnet assembly can produce peak mirror fields on axis 3.6T at injection,2.2T at extraction and a radial sextupole field of 2.0T at plasma chamber wall.A unique feature of SECRAL is that the three axial solenoid coils are located inside of the sextupole bore in order to reduce the interaction forces between the sextupole coils and the solenoid coils. During the ongoing commissioning phase at 18GHz with a stainless steel chamber,tests with various gases and some metals have been conducted with microwave power less than 3.2kW and it turned out the performance is very promising.Some record ion beam intensities have been produced,for instance,810eμA of O^(7+),505eμA of Xe^(20+),306eμA of Xe^(27+),21eμA of Xe^(34+),2.4eμA of Xe^(38+) and so on.To reach better results for highly charged ion beams,further modifications such as an aluminium chamber with better cooling,higher microwave power and a movable extraction system will be done,and also emittance measurements are being prepared.展开更多
基金Equipment Upgrading Fund and '9.5' Fund for Fundamental Research from the Chinese Academy of Sciences
文摘A new 14.5 GHz Electron Cyclotron Resonance (ECR) ion source has been constructed over the last two years. The source was designed and tested by making use of the latest results from ECR ion source development, such as high mirror magnetic field, large plasma volume, and biased probe. 140uA of O^7+, 185uA of Ar^11+ and 50uA of Xe^26+ could be produced with a RF power of 800 W. The intense beams of highly charged metallic ions are produced by means of the method of a metal evaporation oven and volatile compound through axial access. The test results are 130uA of Ca^11+, 70uA of Ca^12+ and 65uA of Fe^lo+. The ion source has been put into operation for the cyclotron at the institute of Modern Physics (IMP).
基金Project supported by the National Basic Research Program of China(Grant No.2010CB832902)the National Natural Science Foundation of China(Grant Nos.11275241,11205225,11105192,and 11275238)
文摘Fe K-shell ionization cross sections induced by 2.4-6.0 MeV Xe^20+ are measured and compared with different binary- encounter-approximation (BEA) models. The results indicate that the BEA model corrected both by the Coulomb repulsion and by the effective nuclear charge (Zeff) agrees well with the experimental data. Comparison of Fe K-shell X-ray emission induced by 5 MeV xenon ions with different initial charge states (20+, 22+, 26+, 30+) verifies the applicability of the effective nuclear charge (Zeff) correction for the BEA model. It is found that Zeff correction is reasonable to describe direct ionization induced by xenon ions with no initial M-shell vacancies. However, when the M shell is opened, the Zeff corrected BEA model is unable to explain the inner-shell ionization, and the electron transfer by molecular-orbital promotion should be considered.
基金Project supported by the National Basic Research Program of China(Grant No.2014CB845502)the National Natural Science Foundation of China(Grant No.91126004)
文摘This paper describes a long-term operation of the 2.45-GHz microwave proton source at Peking University. The DC proton beam of 50–55 mA with energy of 35 keV has been run for 306 hours continuously. Total beam availability,defined as 35-keV beam-on time divided by elapsed time, is higher than 99%. Water cooling machine failures cause all the downtime, and no plasma generator failure or high voltage breakdown is observed. The longest uninterrupted run time is122 hours.
文摘Charge breeding technique is used for RIB (radioactive ion beam) production in order of optimizing the re-acceleration of the radioactive isotopes produced by a primary beam in a thick target. Charge breeding is achieved by means of a device capable of increasing the ion charge state from 1+ to a desired value n+. In some experiments, a continuous RIB of a given energy may be required. To reach this goal, a charge breeding device based on a hollow gun EBIS (electron beam ion source) has been proposed by the author recently. That EBIS, in principle, can be capable to realize a CW (continuous wave) operation. A sufficiently high focusing magnetic field could reduce to zero the hole radius in the EBIS electron beam. However, a smaller efficiency in the ion charge state increase should be expected. A code developed for studying the ion selective containment in a EBIS has been modified and used to simulate the ion charge state breeding. The effects of the hollow electron beam on the breeding rate have been studied.
文摘研制了一台体积和重量都较大、设计性能较高的全永磁电子回旋共振(Electron cyclotron resonance, ECR)离子源LAPECR2(Lanzhou all permanent magnetic ECR ion source No.2)。该离子源将用于中国科学院近代物理研究所320 kV高压平台,为其提供强流高电荷态离子束流。LAPECR2的研制采用全新的全永磁磁体结构设计,通过采用高性能的NdFeB永磁材料、优化的磁结构设计以及精确的计算,实测源体的磁场参数能达到高性能ECR离子源的设计要求。离子源采用较高频率的14.5 GHz微波馈入加热等离子体,波导直接馈入离子源以增强馈入微波的稳定性与效率。此外,还大量采用了一些有利于提高离子源高电荷态离子产额的关键技术,如铝内衬等离子体弧腔、负偏压盘、铝制等离子体电极、三电极引出系统、辅助掺气等。
文摘为满足兰州重离子加速器的实验要求,先后在中国科学院近代物理研究所14.5GHz(LECR2)及10GHz+14.5GHz(LECR3)高电荷态ECR离子源上使用MIVOC(Metallic ion fromvolatile compounds)方法进行了高电荷态金属离子产生的实验研究。主要研究了铁和镍的各种高电荷态离子的产生,具有代表性的是210eμA的Fe11+、175eμA的Fe12+、142eμA的Fe13+、25eμA的Fe16+、64eμA的Ni10+、57eμA的Ni13+、31eμA的Ni15+和15eμA的Ni16+。本文将分别给出两种金属离子产生的多电荷态束流谱图,并对实验装置的安排、实验现象及结果进行讨论与总结。
基金Supported by CAS Knowledge Innovation Program (KJCX1-09)Natural Science Foundation of China for Distinguished Young Scientists (10225523)
文摘A Superconducting ECR ion source with Advanced design in Lanzhou (SECRAL) was successfully built to produce intense beams of highly charged ions for Heavy Ion Research Facility in Lanzhou (HIRFL).The ion source has been optimized to be operated at 28GHz for its maximum performance.The superconducting magnet confinement configuration of the ion source consists of three axial solenoid coils and six sextupole coils with a cold iron structure as field booster and clamping.For 28GHz operation,the magnet assembly can produce peak mirror fields on axis 3.6T at injection,2.2T at extraction and a radial sextupole field of 2.0T at plasma chamber wall.A unique feature of SECRAL is that the three axial solenoid coils are located inside of the sextupole bore in order to reduce the interaction forces between the sextupole coils and the solenoid coils. During the ongoing commissioning phase at 18GHz with a stainless steel chamber,tests with various gases and some metals have been conducted with microwave power less than 3.2kW and it turned out the performance is very promising.Some record ion beam intensities have been produced,for instance,810eμA of O^(7+),505eμA of Xe^(20+),306eμA of Xe^(27+),21eμA of Xe^(34+),2.4eμA of Xe^(38+) and so on.To reach better results for highly charged ion beams,further modifications such as an aluminium chamber with better cooling,higher microwave power and a movable extraction system will be done,and also emittance measurements are being prepared.