期刊文献+
共找到379篇文章
< 1 2 19 >
每页显示 20 50 100
A study of pulsed high voltage driven hollow-cathode electron beam sources through synchronous optical trigger
1
作者 霍卫杰 贺伟国 +2 位作者 韩罗峰 朱康武 王锋 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第5期82-90,共9页
In this study,a pulsed,high voltage driven hollow-cathode electron beam sources through an optical trigger is designed with characteristics of simple structure,low cost,and easy triggering.To validate the new design,t... In this study,a pulsed,high voltage driven hollow-cathode electron beam sources through an optical trigger is designed with characteristics of simple structure,low cost,and easy triggering.To validate the new design,the characteristics of hollow-cathode discharge and electron beam characterization under pulsed high voltage drive are studied experimentally and discussed by discharge characteristics and analyses of waveform details,respectively.The validation experiments indicate that the pulsed high voltage supply significantly improves the frequency and stability of the discharge,which provides a new solution for the realization of a high-frequency,high-energy electron beam source.The peak current amplitude in the high-energy electron beam increases from 6.2 A to 79.6 A,which indicates the pulsed power mode significantly improves the electron beam performance.Besides,increasing the capacitance significantly affects the highcurrent,lower-energy electron beam more than the high-energy electron beam. 展开更多
关键词 hollow-cathode nanosecond pulsed electron beam sources optical trigger pulsed high voltage supply beam current distribution
下载PDF
Compounded Surface Modification of ZK60 Mg Alloy by High Current Pulsed Electron Beam+Micro-plasma Oxidation 被引量:3
2
作者 高波 郝仪 +3 位作者 涂赣峰 石为喜 于福晓 李世伟 《Plasma Science and Technology》 SCIE EI CAS CSCD 2010年第1期67-70,共4页
In this study, compounded surface modification technology-high current pulsed electron beam (HCPEB) + micro-plasma oxidation (MPO) was applied to treat ZK60 Mg alloys. The characteristics of the microstructure of... In this study, compounded surface modification technology-high current pulsed electron beam (HCPEB) + micro-plasma oxidation (MPO) was applied to treat ZK60 Mg alloys. The characteristics of the microstructure of ZK60 Mg alloy after single MPO and HCPEB+MPO compounded treatment were investigated by SEM. The results showed that the density of the ceramic layer of HCPEB+MPO-treated ZK60 Mg alloy was improved and defects were reduced compared to that under MPO treatment alone. Surface modified layer of ZK60 Mg alloys treated by HCPEB+MPO was divided into three zones, namely the top loose ceramic zone, middle compact zone and inside HCPEB-induced melted zone. Corrosion resistance of ZK60 Mg alloy before and after the compounded surface modification was measured in a solution of 3.5% NaCl by potentiodynamic polarization curves. It was found that the corrosion current density of ZK60 Mg alloys could be reduced by about three orders of magnitude, from 311μA/cm^2 of the original sample to 0.2μA/cm^2 of the HCPEB+MPO-treated sample. This indicates the great application potential of the HCPEB+MPO compounded surface modification technology in improving the corrosion resistance of ZK60 Mg alloys in the future. 展开更多
关键词 ZK60 Mg alloy high current pulsed electron beam micro-plasma oxidation compounded surface modification corrosion resistance
下载PDF
Improvement of Wear Resistance of Magnesium Alloy AZ91HP by High Current Pulsed Electron Beam Treatment 被引量:2
3
作者 GAOBo HAOSheng-zhi +3 位作者 ZOUJian-xin JIANGLi-min ZHOUJI-yang DONGChuang 《材料热处理学报》 EI CAS CSCD 北大核心 2004年第05B期1029-1031,共3页
Surface modification of magnesium alloy AZ91HP (9wt%Al, 0.5wt%Zn, 0.5wt%Mn, Mg remaining percentage) by high current pulsed electron beam (HCPEB) treatment was studied in this paper. The secondary phase MgnAln is near... Surface modification of magnesium alloy AZ91HP (9wt%Al, 0.5wt%Zn, 0.5wt%Mn, Mg remaining percentage) by high current pulsed electron beam (HCPEB) treatment was studied in this paper. The secondary phase MgnAln is nearly completely dissolved and as a result, a super-saturated solid solution forms on the re-melted surface. The microhardness is increased both in and far beyond the heat-affected zone (HAZ), reaching about 250um. Measurements on sliding wear have shown that the wear resistance of the treated samples was improved by a factor of about 2.4 as compared to the as-received sample. It is also found that the sliding wear resistance can be further improved by surface alloying with TiN. 展开更多
关键词 镁合金 HCPEB 磨损性能 AZ91HP 表面改性 高电流脉冲电子束
下载PDF
Improvement of wear resistance of AZ31 and AZ91HP by high current pulsed electron beam treatment 被引量:1
4
作者 高波 郝胜智 +1 位作者 董闯 涂赣峰 《中国有色金属学会会刊:英文版》 EI CSCD 2005年第5期978-984,共7页
The surface modification of magnesium alloys (AZ31 and AZ91HP) was studied by a high current pulsed electron beam(HCPEB). The results show that the cross-sectional microhardness of treated samples increases not only i... The surface modification of magnesium alloys (AZ31 and AZ91HP) was studied by a high current pulsed electron beam(HCPEB). The results show that the cross-sectional microhardness of treated samples increases not only in the heat affected zone(HAZ), but also beyond HAZ, reaching over 250μm. This is due to the action of quasi-static thermal stress and the shock thermal stress wave with materials, which result in its fast deformation on the surface layer and so increases microhardness. For the AZ91HP alloy, a nearly complete dissolution of the intermetallic phase Mg_ 17Al_ 12 is observed, and a super-saturated solid solution forms on the re-melted surface, which is due to the solute trapping effect during the fast solidification process. Measurements on sliding wear show that wear resistance is improved by approximately 5.6 and 2.4 times for the AZ31 and AZ91HP respectively, as compared with as-received samples. 展开更多
关键词 铝合金 磨损阻力 脉冲处理 电子波 强度 密度 金属相
下载PDF
Characterizing modified surface layer of 316L stainless steel treated by high current pulsed electron beam
5
作者 GROSDIDIER Thierry 《Rare Metals》 SCIE EI CAS CSCD 2007年第S1期61-66,共6页
High current pulsed electron beam(HCPEB) is now developing as a useful tool for surface modification of materials.When concentrated electron flux transferring its energy into the surface layer of target material withi... High current pulsed electron beam(HCPEB) is now developing as a useful tool for surface modification of materials.When concentrated electron flux transferring its energy into the surface layer of target material within a short pulse time,coupled thermal and stress processes would lead to the formation of metastalbe microstructure with improved properties.In the present work,HCPEB treatment of 316L stainless steel(SS) was carried out and the microstructural changes in modified surface layer were characterized with optical microscopy,X-ray diffractometry and electron backscatter diffractometry(EBSD) techniques.The corrosion resistance of modified surface was measured in a 5wt.% salt solution.The evolution regularity of surface craters and grain refinement effect,as well as the preferred orientation of(111) crystal plane occurring in the HCPEB treatment under different working parameters were discussed along with their influence on corrosion resistance. 展开更多
关键词 high current pulsed electron beam surface modification 316L stainless steel MICROSTRUCTURE CORROSION
下载PDF
HIGH-CURRENT PULSED ELECTRON BEAM: RAPID SURFACE ALLOYING AND WEAR RESISTANCE IMPROVEMENT
6
作者 J.Xu H.W.Liu +5 位作者 Z.R.Zhou C.Dong A.M.Wu S.Z.Hao A.M.Zhang T.Xu 《Acta Metallurgica Sinica(English Letters)》 SCIE EI CAS CSCD 2003年第4期276-282,共7页
The present paper reports the rapid surface alloying induced by the bombardment of high-current pulsed electron beam. Two kinds of substrate materials were examined to show this effect. The first sample was a pure Al ... The present paper reports the rapid surface alloying induced by the bombardment of high-current pulsed electron beam. Two kinds of substrate materials were examined to show this effect. The first sample was a pure Al metal pre-coated with fine carbon powders prior to the bombardment, and the second alloy is the D2-Crl2MolVl mould steel pre-coated with Cr, Ti, and TiN powders. The surface elements diffuse about several micrometers into the substrate materials only after several bombardments. Tribological behaviors of these samples were characterized and significant improvement in wear resistance was found. Finally, a TEM analysis reveals the presence of stress waves generated by coupled thermal and stress fields, which was considered as the main cause of the enhanced properties. 展开更多
关键词 high-current pulsed electron beam surface alloying TRIBOLOGY fretting wear
下载PDF
Numerical simulation of thermal-mechanical process of Al-Si-Pb alloy treated by high current pulsed electron beam
7
作者 吕晓霞 李荣广 安健 《中国有色金属学会会刊:英文版》 CSCD 2006年第A03期1433-1436,共4页
The modified microstructure of Al-Si-Pb alloys irradiated by high current electron beam (HCPEB) reveals three distinct regions: a molten zone, an overlapped zone of heat-affected and quasistatic thermal stress-affecte... The modified microstructure of Al-Si-Pb alloys irradiated by high current electron beam (HCPEB) reveals three distinct regions: a molten zone, an overlapped zone of heat-affected and quasistatic thermal stress-affected zone, and a transition zone followed by the substrate. The hardness and wear properties of the alloys were significantly improved. To better understand these changes in microstructure and properties, the physical model for the simulation of temperature and quasistatic stress fields was established. Based on experimental investigation and physical models, the temperature field and stress field were simulated for Al-Si-Pb alloy. The starting melting position, largest crater depth, melting layer thickness, and quasistatic stress distribution were obtained. These results reveal the mechanism of crater formation on the surface and improvement of hardness and wear resistance. 展开更多
关键词 热量行为 机械性能 合金 电子束 有色金属
下载PDF
Microstructure and properties of Nb/Ta multilayer films irradiated by a high current pulse electron beam
8
作者 马欣新 郭光伟 +2 位作者 唐光泽 孙明仁 王黎钦 《Chinese Physics B》 SCIE EI CAS CSCD 2013年第5期407-411,共5页
Nb/Ta multilayer films deposited on Ti6A14V substrate with Nb and Ta monolayer thicknesses of 30 nm, 120 nm, and 240 nm were irradiated by a high current pulse electron beam (HCPEB) to prepare Nb-Ta alloyed layers. ... Nb/Ta multilayer films deposited on Ti6A14V substrate with Nb and Ta monolayer thicknesses of 30 nm, 120 nm, and 240 nm were irradiated by a high current pulse electron beam (HCPEB) to prepare Nb-Ta alloyed layers. The mi- crostructure and the composition of the outmost surface of melted alloyed layers were investigated using a transmission electron microscope (TEM) equipped with an X-ray energy dispersive spectrometer (EDS) attachment. The Ta content of the alloyed surface layer prepared from the monolayer of thickness 30 nm, 120 nm, and 240 nm was- 27.7 at.%, 6.37 at.%, and 0 at.%, respectively. It was found that the Ta content in the alloyed layer plays a dominant role in the microstructure of the films. The hardness and the wear rate of the alloyed layers decrease with the increasing content of Ta in the surface laver. 展开更多
关键词 Nb-Ta alloyed layer multilayer film high current pulse electron beam wear resistance
下载PDF
Microstructure and property modifications in surface layers of a Mg-4Sm-2Al-0.5Mn alloy induced by pulsed electron beam treatments 被引量:4
9
作者 Yingrui Liu Kemin Zhang +3 位作者 Jianxin Zou Ping Yan Xu Zhang Luxia Song 《Journal of Magnesium and Alloys》 SCIE EI CAS CSCD 2021年第1期216-224,共9页
In this work,surface modification of a Mg-4Sm-2Al-0.5Mn alloy with high current pulse electron beam(HCPEB)under different number of pulses were investigated.The evolution in microstructure,composition and phase compon... In this work,surface modification of a Mg-4Sm-2Al-0.5Mn alloy with high current pulse electron beam(HCPEB)under different number of pulses were investigated.The evolution in microstructure,composition and phase components and properties in the surface layer before and after HCPEB treatment were characterized.It was found that the Al 11 Sm 3 and Al 2 Sm phases in the surface layer were gradually dissolved during HCPEB treatment,leading to the formation of a chemical homogeneous melted layers.Besides,deformation bands were formed in the treated layer due to the thermal stress generated during treatment.After 15 pulses treatment,the surface hardness increases to the maximum value of about 62.2 HV,about 61.2%higher than that of the untreated state.Electrochemical results show that the 15 pulses treated sample presents the best corrosion resistance in the 3.5wt%NaCl water solution by showing the highest corrosion potential(E_(corr))of-1.339V SEC and the lowest corrosion current density(I_(corr))of 1.48×10^(-6)A·cm^(-2).The results prove that the surface properties of the Mg-4Sm-2Al-0.5Mn alloy can be significantly improved by the HCPEB treatments under proper conditions. 展开更多
关键词 high current pulsed electron beam(HCPEB) Surface modification Mg rare earth alloy MICROSTRUCTURES CORROSION-RESISTANCE
下载PDF
Ultra Fast Shutter Driven by Pulsed High Current 被引量:2
10
作者 曾江涛 孙凤举 +3 位作者 邱爱慈 尹佳辉 郭建明 陈玉兰 《Plasma Science and Technology》 SCIE EI CAS CSCD 2005年第2期2781-2784,共4页
Radiation simulation utilizing plasma radiation sources (PRS) generates a large number of undesirable debris, which may damage the expensive diagnosing detectors. An ultra fast shutter (UFS) driven by pulsed high curr... Radiation simulation utilizing plasma radiation sources (PRS) generates a large number of undesirable debris, which may damage the expensive diagnosing detectors. An ultra fast shutter (UFS) driven by pulsed high current can erect a physical barrier to the slowly moving debris after allowing the passage of X-ray photons. The UFS consists of a pair of thin metal foils twisting the parallel axes in a Nylon cassette, compressed with an outer magnetic field, generated from a fast capacitor bank, discharging into a single turn loop. A typical capacitor bank is of 7.5μF charging voltages varying from 30 kV to 45 kV, with corresponding currents of approximately 90 kA to140 kA and discharging current periods of approximately 13.1μs. A shutter closing time as fast as 38 microseconds has been obtained with an aluminium foil thickness of 100 micrometers and a cross-sectional area of 15 mm by 20 mm. The design, construction and the expressions of the valve-closing time of the UFS are presented along with the measured results of valve-closing velocities. 展开更多
关键词 plasma radiation source (PRS) ultra fast shutter pulsed high current
下载PDF
Development of a high current short pulse electron gun
11
作者 宗阳 张子民 +7 位作者 袁平 申晓康 赵全堂 王燕茹 李中平 曹树春 刘铭 景漪 《Nuclear Science and Techniques》 SCIE CAS CSCD 2014年第3期43-46,共4页
Dielectric wall accelerator(DWA), towards high gradient acceleration field(30 MeV/m–100 MeV/m), is under development at Institute of Modern Physics. A prototype was designed and constructed to prove the principle. Th... Dielectric wall accelerator(DWA), towards high gradient acceleration field(30 MeV/m–100 MeV/m), is under development at Institute of Modern Physics. A prototype was designed and constructed to prove the principle. This needs a short pulse high current electron source to match the acceleration field generated by the Blumlein-type pulse forming lines(PFLs). In this paper, we report the design and test of a new type short pulse high current electron gun based on principle of vacuum arc discharge. Electron beams of 100 mA with pulse width of 10 ns were obtained. 展开更多
关键词 电子枪 短脉冲 高电流 近代物理研究所 脉冲形成线 加速度场 放电原理 真空电弧
下载PDF
High temperature cyclic oxidation behavior of Y_2O_3-ZrO_2 thermal barrier coatings irradiated by high-intensity pulsed ion beam
12
作者 王一奇 雷明凯 +1 位作者 AFSAR A M SONG J I 《Journal of Central South University》 SCIE EI CAS 2009年第1期13-17,共5页
The high-temperature oxidation resistance behavior of 7% (mass fraction) Y2O3-ZrO2 thermal barrier coatings (TBCs) irradiated by high-intensity pulsed ion beam (HIPIB) was investigated under the cyclic oxidation condi... The high-temperature oxidation resistance behavior of 7% (mass fraction) Y2O3-ZrO2 thermal barrier coatings (TBCs) irradiated by high-intensity pulsed ion beam (HIPIB) was investigated under the cyclic oxidation condition of 1 050 ℃ and 1 h. The columnar grains in the TBCs disappear after the HIPIB irradiation at ion current densities of 100?200 A/cm2 and the irradiated surface becomes smooth and densified after remelting and ablation due to the HIPIB irradiation. The thermally grown oxide (TGO) layer thickness of the irradiated TBCs is smaller than that of the original TBCs. After 15 cycles, the mass gains of the original TBCs and those irradiated by ion current densities of 100 and 200 A/cm2 due to the oxidation are found to be 0.8?0.9, 0.6?0.7, and 0.3?0.4 mg/cm2, respectively. The inward diffusion of oxygen through the irradiated TBCs is significantly impeded by the densified top layer formed due to irradiation, which is the main reason for the improved overall oxidation resistance of the irradiated TBCs. 展开更多
关键词 涂层 化学性质 抗氧化性能 高强度脉冲离子束 电流密度
下载PDF
Development of data acquisition and over-current protection systems for a suppressor-grid current with a neutral-beam ion source
13
作者 刘伟 胡纯栋 +5 位作者 刘胜 宋士花 汪金新 王艳 赵远哲 梁立振 《Plasma Science and Technology》 SCIE EI CAS CSCD 2017年第12期154-158,共5页
Neutral beam injection is one of the effective auxiliary heating methods in magnetic-confinementfusion experiments. In order to acquire the suppressor-grid current signal and avoid the grid being damaged by overheatin... Neutral beam injection is one of the effective auxiliary heating methods in magnetic-confinementfusion experiments. In order to acquire the suppressor-grid current signal and avoid the grid being damaged by overheating, a data acquisition and over-current protection system based on the PXI(PCI e Xtensions for Instrumentation) platform has been developed. The system consists of a current sensor, data acquisition module and over-current protection module. In the data acquisition module,the acquired data of one shot will be transferred in isolation and saved in a data-storage server in a txt file. It can also be recalled using NBWave for future analysis. The over-current protection module contains two modes: remote and local. This gives it the function of setting a threshold voltage remotely and locally, and the forbidden time of over-current protection also can be set by a host PC in remote mode. Experimental results demonstrate that the data acquisition and overcurrent protection system has the advantages of setting forbidden time and isolation transmission. 展开更多
关键词 neutral beam injection high-current ion source suppression grid current data acquisition and protection system
下载PDF
A Pulsed Electromagnet for Laser Wakefield Electron Acceleration Experiments
14
作者 Septimiu Balascuta 《Journal of Electromagnetic Analysis and Applications》 2016年第3期33-41,共9页
Laser Wakefield plasma acceleration of electrons to energies above 10 GeV, may be possible in the new high power Laser beam facilities. The design of an Electron Spectrometer with an electro-magnet with adjustable mag... Laser Wakefield plasma acceleration of electrons to energies above 10 GeV, may be possible in the new high power Laser beam facilities. The design of an Electron Spectrometer with an electro-magnet with adjustable magnetic field is proposed for the characterization of electron energy spectrum with a precision better than 10% for the entire energy range from 0.5 GeV to 38 GeV. The expected precision in the measurement of the electron energy is calculated as a function of the magnetic field, of the electron energy and of the magnet length. To outline the advantages offered by a pulsed electromagnet with high magnetic fields, the mass and the electric power lost in the coils of a 4 m long electromagnet with continuous current and Iron yoke are calculated. 展开更多
关键词 electron Spectrometer ELECTROMAGNET electron beam Magnetic Field pulsed Electric current DC Electric current
下载PDF
Equilibrium electron beam parameters of the High Energy Photon Source
15
作者 Haisheng Xu Cai Meng +28 位作者 Yuemei Peng Saike Tian Na Wang Xiaohao Cui Chongchong Du Zhe Duan Yuanyuan Guo Ping He Xiyang Huang Daheng Ji Hongfei Ji Yi Jiao Jingyi Li Nan Li Xiaoyu Li Xiaohan Lu Pengfei Liang Weimin Pan Huamin Qu Bin Wang Jiuqing Wang Yuanyuan Wei Jinyu Wan Gang Xu Fang Yan Chenghui Yu Sen Yue Xiang Zhang Yaliang Zhao 《Radiation Detection Technology and Methods》 CSCD 2023年第2期279-287,共9页
Purpose The physics design of the High Energy Photon Source(HEPS)was finished after many times of iteration.Hereby,the typical equilibrium electron beam parameters corresponding to the proposed two baseline operation ... Purpose The physics design of the High Energy Photon Source(HEPS)was finished after many times of iteration.Hereby,the typical equilibrium electron beam parameters corresponding to the proposed two baseline operation modes in the baseline design of HEPS are presented.Methods To compute the equilibrium parameters of the electron beam,the lattice parameters,RF parameters,and the parameters of the insertion devices(IDs)were determined first.Furthermore,it is more precise to use the full-current electron beam parameters in the estimations of the performance of the synchrotron light.Therefore,not only the single-particle dynamics but also the current-dependent collective effects need to be considered in the computations of the full-current,equilibrium parameters of the electron beam.Both analytic computations and multi-particle tracking simulations were carried out.Results The full-current,equilibrium parameters of the electron beams in the HEPS storage ring are presented in this paper.Moreover,the main beam parameters in the injector(the booster and the LINAC),corresponding to the two baseline operation modes of the storage ring,are also presented.Conclusion The typical electron beam parameters corresponding to the two baseline operation modes are given in detail in this paper. 展开更多
关键词 high Energy Photon source electron beam parameters
原文传递
一种小尺寸轫致辐射转换靶设计
16
作者 荆晓兵 石金水 《强激光与粒子束》 CAS CSCD 北大核心 2024年第3期112-116,共5页
以减小直线感应加速器X射线光源横向尺寸为目标,开展轫致辐射转换靶的设计。对聚焦打靶过程中电子束运动轨迹进行分析,指出同一个电子束轨迹分布,既可以描述为电子束在某纵向位置处具有一定的横向展宽,也可以描述为电子束保持较小横向... 以减小直线感应加速器X射线光源横向尺寸为目标,开展轫致辐射转换靶的设计。对聚焦打靶过程中电子束运动轨迹进行分析,指出同一个电子束轨迹分布,既可以描述为电子束在某纵向位置处具有一定的横向展宽,也可以描述为电子束保持较小横向尺寸时的轴向分布展宽,由此提出在束腰附近放置多个小靶片实现聚焦电子束有效阻挡的小尺寸多层靶概念设计。采用EGS4程序对X射线产额进行计算,发现靶厚度在一定范围内改变时X射线产额变化较小,基于这一规律完成了小尺寸多层靶的结构设计。进一步考察了一个设计应用实例,当聚焦电子束最小包络直径3 mm、会聚角100 mrad时,对比大尺寸靶,采用小尺寸多层靶可以获得等效直径减小约50%、产额减小约10%的X射线光源。该设计方法有望在相同的电子束品质和聚焦条件下,获得横向尺寸小于电子束最小束包络直径的X射线光源,具有一定的应用价值。 展开更多
关键词 直线感应电子加速器 X射线光源 强流电子束 聚焦 轫致辐射转换靶
下载PDF
高能束表面改性技术在航空领域的应用
17
作者 陈军 李伟 郝胜智 《航空制造技术》 CSCD 北大核心 2024年第4期32-43,共12页
高能束表面改性适用于各种金属和合金,能够显著提升材料表面硬度、耐磨、耐蚀等性能指标,是航空部件实现性能提升的有效手段之一。本文总结了6种高能束表面改性技术的基本原理、设备构成和改性应用,其中激光相变硬化通过马氏体相变强化... 高能束表面改性适用于各种金属和合金,能够显著提升材料表面硬度、耐磨、耐蚀等性能指标,是航空部件实现性能提升的有效手段之一。本文总结了6种高能束表面改性技术的基本原理、设备构成和改性应用,其中激光相变硬化通过马氏体相变强化金属材料表面;激光熔覆通过选择不同粉末实现表面修复和表面性能提升,重点在于控制裂纹缺陷;激光冲击强化可有效解决航空发动机部件高周疲劳断裂问题;强流脉冲电子束和强流脉冲离子束一方面需要提高设备的性能和运行稳定性,另一方面要针对航空部件应用开展深入研究;而离子束辅助沉积则可以通过制备固体润滑涂层实现对微动磨损的有效防护。最后,提出对高能束表面改性机理深入研究、发展专业化智能化装备和实现多种束源复合与集成的发展方向。 展开更多
关键词 表面改性 激光相变硬化 激光熔覆 激光冲击强化 强流脉冲电子束 强流脉冲离子束 离子束辅助沉积
下载PDF
Enhanced Surface Properties Induced by High Current Pulsed Electron Beam (HCPEB) Treatment 被引量:4
18
作者 Hao Shengzhi1,2,Wang Huihui1,2,Li Mincai1,3,Xu Yang1,3,Dong Chuang1,3 1Key Laboratory of Materials Modification by Laser,Ion and Electron Beams,Ministry of Education,Dalian University of Technology,Dalian 116024,China2School of Physics and Optoelectronics Engineering,Dalian University of Technology,Dalian 116024,China3School of Material Science and Engineering,Dalian University of Technology,Dalian 116024,China 《稀有金属材料与工程》 SCIE EI CAS CSCD 北大核心 2011年第S4期178-180,共3页
High current pulsed electron beam (HCPEB) has been developed as a useful tool for surface treatment of materials.In the present work,the fundamental principle of HCPEB source was described along with the device config... High current pulsed electron beam (HCPEB) has been developed as a useful tool for surface treatment of materials.In the present work,the fundamental principle of HCPEB source was described along with the device configuration and working parameters.Through the different kinds of HCPEB surface treatment experiments conducted,the enhanced surface properties induced by HPCEB treatment were illustrated and explained with their microstructure characterization results. 展开更多
关键词 high current pulsed electron beam surface TREATMENT microstructure PROPERTY
原文传递
Deformation mechanism and microstructures on polycrystalline aluminum induced by high-current pulsed electron beam 被引量:7
19
作者 CAI Jie JI Le +4 位作者 YANG ShengZhi WANG XiaoTong LI Yan HOU XiuLi GUAN QingFeng 《Chinese Science Bulletin》 SCIE EI CAS 2013年第20期2507-2511,共5页
In this paper, we present an experimental investigation of deformation twinning in polycrystalline aluminum exposed to high-current pulsed electron beam (HCPEB) irradiation. The residual tensile stress with about 10 2... In this paper, we present an experimental investigation of deformation twinning in polycrystalline aluminum exposed to high-current pulsed electron beam (HCPEB) irradiation. The residual tensile stress with about 10 2 MPa was introduced in the irradiated surface layer. The feature characteristic irradiated with various numbers of pulses was investigated. The formation of a large number of twin bands on the surface irradiated with multiple pulses was determined. The experimental observations indicated that the deformation twinning was indeed triggered during HCPEB irradiation. It is suggested that high value of stress and strain rate induced by rapid heating and cooling due to HCPEB irradiation may cause the shifting of whole atomic planes simultaneously. Additionally, some slipping systems may be suppressed due to the geometric confinement by thinned size of surface layer, which can promote the initiation of deformation twinning. 展开更多
关键词 强流脉冲电子束 变形机制 多晶铝 微观结构 高电流 电子束照射 实验观察 残余拉应力
原文传递
Corrosion Resistance of AZ91 Mg Alloy Modified by High-Current Pulsed Electron Beam 被引量:3
20
作者 Peng-Peng Wu Kun-Kun Deng +1 位作者 Kai-Bo Nie Zhong-Zhong Zhang 《Acta Metallurgica Sinica(English Letters)》 SCIE EI CAS CSCD 2019年第2期218-226,共9页
The high-current pulsed electron beam(HCPEB) treatment with current density 6 J/cm^2 was applied on AZ91 Mg alloy to improve its corrosion resistance. Results showed that the net-like Mg_(17)Al_(12) disappeared on the... The high-current pulsed electron beam(HCPEB) treatment with current density 6 J/cm^2 was applied on AZ91 Mg alloy to improve its corrosion resistance. Results showed that the net-like Mg_(17)Al_(12) disappeared on the surface of AZ91 Mg alloy after irradiation by HCPEB, which was instead of supersaturated Al element on the surface. Nevertheless, the application of HCPEB also led to the formation of crater-like and groove-like structures as well as micro-cracks on the surface of AZ91 Mg alloy. After HCPEB treatment by 3, 5 and 10 pulses, the AZ91 Mg alloy exhibited better corrosion resistance.However, the increasing amount of micro-cracks reduced the anti-corrosive properties of AZ91 Mg alloy as the pulse increased to 20 and 30. 展开更多
关键词 high-current pulsed electron beam(HCPEB) Corrosion resistance Electrochemical IMPEDANCE spectroscopy(EIS) AZ91 Mg alloy Microstructure
原文传递
上一页 1 2 19 下一页 到第
使用帮助 返回顶部