期刊文献+
共找到24,903篇文章
< 1 2 250 >
每页显示 20 50 100
Determination of Benzo[a]pyrene in Edible Oil by High Performance Liquid Chromatography-Fluorescence Detector (HPLC-FL)
1
作者 Guixia YANG Jie LIU +3 位作者 Xiujuan WANG Fenglan ZHANG Kun XIN Chunli KONG 《Agricultural Biotechnology》 2024年第2期8-9,19,共3页
In this study, an optimized high performance liquid chromatography-fluorescence detector (HPLC-FL) method for the determination of benzo[a]pyrene in edible oil was established. HPLC was performed with Thermo Fisher Sc... In this study, an optimized high performance liquid chromatography-fluorescence detector (HPLC-FL) method for the determination of benzo[a]pyrene in edible oil was established. HPLC was performed with Thermo Fisher Scientific C18 column (250 mm×4.6 mm, 5 μm) as the chromatographic column and acetonitrile and water as the mobile phase, and the excitation wavelength and emission wavelength of fluorescence detector were 286 and 430 nm, respectively. The response was high, and the linear range was 0.5-10.0 ng/ml. The lowest limit of detection was 0.11 ng/ml, and the average recovery was 92.5%. This method is suitable for quantitative analysis of benzo[a]pyrene content in edible oil. 展开更多
关键词 BENZO[A]PYRENE high performance liquid chromatography fluorescence detector
下载PDF
On-line enrichment and determination of polycyclic aromatic hydrocarbons in atmospheric particulates using high performance liquid chromatography with fluorescence as detector 被引量:1
2
作者 HASHI Yuki WANG Tian-ran +1 位作者 LI Yue-qi LIN Jin-ming 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2007年第10期1261-1265,共5页
Seven polycyclic aromatic hydrocarbons (PAHs) in atmospheric particulates were determinated by high performance liquid chromatography (HPLC) with fluorescence detector using direction injection and an on-line enri... Seven polycyclic aromatic hydrocarbons (PAHs) in atmospheric particulates were determinated by high performance liquid chromatography (HPLC) with fluorescence detector using direction injection and an on-line enrichment trap column. The method simplified the sample pretreatment, saved time and increased the efficiency. With the on-line trap column, PAHs were separated availably even underground injecting 1.0 ml sample with relatively high column efficiency. The recoveries of the seven PAHs were from 85% to 120% for spiked atmospheric particulate sample. The limit of detection was 15.3-39.6 ng/L (S/N=3.3). There were good linear correlations between the peak areas and concentrations of the seven kinds of PAHs in the range of 1-50 ng/ml with the correlation coefficients over 0.9970. Furthermore, it also indicated that the method is available to determine PAHs in atmospheric particulates well. 展开更多
关键词 on-line enrichment on-line trap column high performance liquid chromatography (HPLC) atmospheric particulate polycyclic aromatic hydrocarbons (PAHs)
下载PDF
Optimization of Ultrasonic Extraction and Clean-up Protocol for the Determination of Polycyclic Aromatic Hydrocarbons in Marine Sediments by High-performance Liquid Chroma-tography Coupled with Fluorescence Detection 被引量:1
3
作者 PENG Xuewei YAN Guofang +3 位作者 LI Xianguo GUO Xinyun ZHOU Xiao WANG Yan 《Journal of Ocean University of China》 SCIE CAS 2012年第3期331-338,共8页
The procedures of ultrasonic extraction and clean-up were optimized for the determination of polycyclic aromatic hydrocarbons (PAHs) in marine sediments. Samples were ultrasonically extracted, and the extracts were pu... The procedures of ultrasonic extraction and clean-up were optimized for the determination of polycyclic aromatic hydrocarbons (PAHs) in marine sediments. Samples were ultrasonically extracted, and the extracts were purified with a miniaturized silica gel chromatographic column and analyzed with high performance liquid chromatography (HPLC) with a fluorescence detector. Ultrasonication with methanol-dichloromethane (2:1, v/v) mixture gave higher extraction efficiency than that with dichloromethane. Among the three elution solvents used in clean-up step, dichloromethane-hexane (2:3, v/v) mixture was the most satisfactory. Under the optimized conditions, the recoveries in the range of 54.82% to 94.70% with RSDs of 3.02% to 23.22% for a spiked blank, and in the range of 61.20% to 127.08% with RSDs of 7.61% to 26.93% for a spiked matrix, were obtained for the 15 PAHs studied, while the recoveries for a NIST standard reference SRM 1941b were in the range of 50.79% to 83.78% with RSDs of 5.24% to 21.38%. The detection limits were between 0.75 ng L-1 and 10.99 ng L-1for different PAHs. A sample from the Jiaozhou Bay area was examined to test the established methods. 展开更多
关键词 ultrasonic extraction marine sediment polycyclic aromatic hydrocarbon high performance liquid chromatography
下载PDF
Molecular Weight Distribution of Dissolved Organic Matter in Lake Hongfeng Determined by High Performance Size Exclusion Chromatography (HPSEC) With On-Line UV-Vis Absorbance and Fluorescence Detection 被引量:3
4
作者 岳兰秀 吴丰昌 +3 位作者 刘丛强 黎文 王静 梅毅 《Chinese Journal Of Geochemistry》 EI CAS 2004年第3期275-283,共9页
The molecular weight distribution (MWD) of dissolved organic matter (DOM) in lake waters from Lake Hongfeng was examined using high performance size exclusion chromatography (HPSEC) with UV-vis absorbance and fluoresc... The molecular weight distribution (MWD) of dissolved organic matter (DOM) in lake waters from Lake Hongfeng was examined using high performance size exclusion chromatography (HPSEC) with UV-vis absorbance and fluorescence detection. The elution curves obtained by absorbance and fluorescence techniques expressed similar patterns, with the exception of diminishing of large fraction and the peaks behind several seconds in fluorescence chromatograms. According to its molecular weight (MW), DOM in water samples is divided into several fractions: large ({>3.5} kDa); medium-large ({3.5}-{2.0} kDa); medium ({2.0}-{1.0} kDa) and small ({<1.0} kDa). The average molecular weight was calculated using the elution curve detected by UV-vis absorbance and fluorescence detection techniques. The results showed that the weight-average molecular weight (Mw) and number-average molecular weight (Mn) calculated by UV-vis absorbance techniques range from 1750 to 2050 Dalton and from 1450 to 1850 Dalton, respectively. And the Mw and Mn obtained by fluorescence detection are lower by 50 to 400 Dalton. As a reference, the molecular weight of Fluka humic acid (FHA) is larger than that of water samples by about 200 Dalton. The average molecular weight of DOM for water samples collected in March and July was compared. The results revealed that the molecular weight is lower for water samples obtained in July than that obtained in March, indicating the ambient environment has an influence on the molecular weight, including photo-degradation and biological activity. 展开更多
关键词 液化有机物 分子量 平均数 吸收比 荧光性 聚合化合物 湖水生物化学
下载PDF
Bio-analytical method development and validation of Rasagiline by high performance liquid chromatography tandem mass spectrometry detection and its application to pharmacokinetic study 被引量:2
5
作者 Ravi Kumar Konda Babu Rao Chandu +1 位作者 B.R.Challa Chandrasekhar B.Kothapalli 《Journal of Pharmaceutical Analysis》 SCIE CAS 2012年第5期342-349,共8页
The most suitable bio-analytical method based on liquid liquid extraction has been developed and validated for quantification of Rasagiline in human plasma. Rasagiline-13C3 mesylate was used as an internal standard fo... The most suitable bio-analytical method based on liquid liquid extraction has been developed and validated for quantification of Rasagiline in human plasma. Rasagiline-13C3 mesylate was used as an internal standard for Rasagiline. Zorbax Eclipse Plus C18 (2.1 mm × 50 mm, 3.5 um) column provided chromatographic separation of analyte followed by detection with mass spectrometry. The method involved simple isocratic chromatographic condition and mass spectrometric detection in the positive ionization mode using an API-4000 system. The lotal run time was 3.0 min. The proposed method has been validated with the linear range of 5 12000 pg/mL for Rasagiline. The intra-run and inter-run precision values were within 1.3% 2.9% and 1.6% 2.2% respectively for Rasagiline. The overall recovery for Rasagiline and Rasagiline-13C3 mesylate analog was 96.9% and 96.7% respectively. This validated method was successfully applied to the bioequivalence and pharmacokinetic study of human volunteers under fasting condition. 展开更多
关键词 high performance liquid chromatography Mass spectrometry RASAGILINE liquid-liquid extraction
下载PDF
Rapid Determination of Dopamine and Its Metabolites During in vivo Cerebral Microdialysis by Routine High Performance Liquid Chromatography With Electrochemical Detection 被引量:1
6
作者 FU-CHUN JING HONG CHEN CHANG-LING LI 《Biomedical and Environmental Sciences》 SCIE CAS CSCD 2007年第4期317-320,共4页
To determine dopamine and its metabolites during in vivo cerebral microdialysis by routine high performance liquid chromatography with electrochemical detection. Methods Microdialysis probes were placed into the right... To determine dopamine and its metabolites during in vivo cerebral microdialysis by routine high performance liquid chromatography with electrochemical detection. Methods Microdialysis probes were placed into the right striatum of Wistar rat brains and perfused with Ringer's solution at a rate of 1.5 pL/min. A reverse phase HPLC with electrochemistry was used to assay DA, DOPAC, and HVA after cerebral microdialysates were collected every 20 minutes from awake and freely moving rats. In order to identify the reliability of this method, its selectivity, linear range, precision and accuracy were tested and the contents of DA, DOPAC, and HVA in rat microdialysates were determined. Results The standard curve was in good linear at the concentration ranging from 74 nmol/L to 1.5 pmol/L for DOPAC (r^2= 0.9996), from 66 nmol/L to 1.3 gmol/L for DA (r^2=l.0000) and from 69 nmol/L to 1.4 pmol/L for HVA (r^2=0.9992). The recovery of DOPAC (0.30, 0.77, 1.49 gmol/L), DA (0,26, 0.69, 1.32 gmol/L), and HVA (0.27, 0.71, 1.37 gmol/L) was 82.00±1.70%, 104.00±4.00%, 98.70±3.10%; 92.30± 1.50%, 105.30±2.30%, 108.00±2.00%; 80.00±7.80%, 107.69±8.00%, and 108.66±3.10%, respectively at each concentration. Their intra-day RSD was 3.3%, 3.4%, and 2.5%, and inter-day RSD was 4.2%, 2.3%, and 5.6%, respectively. The mean extracellular concentrations of DOPAC, DA, and HVA in rat brain microdialysates were 10.7, 2.4, and 9.2 gmol/L (n=6), respectively. Conclusion The findings of our study suggested that the simple, accurate and stable method can be applied to basic researches of diseases related to monoamines neurotransmitters by cerebral microdialysis in rats. 展开更多
关键词 Dopamine (DA) 3 4-dihydroxyphenylacetic acid (DOPAC) Homovanillic acid (HVA) Cerebral microdialysis high performance liquid chromatography Electrochemical detection
下载PDF
Research Advances in Detection Techniques of High Performance Liquid Chromatography-Refractive Index Detector 被引量:1
7
作者 Huo Fang Zhang Zhimei +3 位作者 Wang Jianjun Guo Shijin Zhou Chunfeng Fu Shijun 《Animal Husbandry and Feed Science》 CAS 2014年第2期87-90,共4页
As a highly sensitive and stable detector,refractive index detector is usually used for quantitative detection of substances such as polymer,sugar and organic acid. The research reviewed the application of HPLC-RID in... As a highly sensitive and stable detector,refractive index detector is usually used for quantitative detection of substances such as polymer,sugar and organic acid. The research reviewed the application of HPLC-RID in the fields of quantitative determination of medicine and food,in order to lay a foundation for wider use of RID. 展开更多
关键词 Refractive index detector high performance liquid chromatography Research progress
下载PDF
A High-Performance Liquid Chromatography Method for the Simultaneous Determination of Five Index Components in Danhong Injection
8
作者 Yun An Tian Tian +2 位作者 Qinglin Wang Xingchu Gong Chenchen Wang 《American Journal of Analytical Chemistry》 CAS 2023年第11期481-492,共12页
The purpose of this study was to establish a high-performance liquid chromatography (HPLC) method for the simultaneous determination of sodium danshensu, protocatechuic aldehyde, rosmarinic acid, salvianolic acid B, a... The purpose of this study was to establish a high-performance liquid chromatography (HPLC) method for the simultaneous determination of sodium danshensu, protocatechuic aldehyde, rosmarinic acid, salvianolic acid B, and 4-coumaric acid in Danhong injection. The chromatographic method employed was as follows: the column was a Welch Ultimate XB-C18 column (250 mm × 4.6 mm, 10 μm), the mobile phase was a gradient elution of 0.4% formic acid aqueous solution (A) and acetonitrile (B), the detection wavelengths were 280 nm for sodium danshensu, protocatechuic aldehyde, and salvianolic acid B and 326 nm for 4-coumaric acid and rosmarinic acid, the sample volume was 10 μL, the flow rate was 1.0 mL/min, and the column temperature was 35°C. This method can realize the separation and determination of sodium danshensu, protocatechuic aldehyde, rosmarinic acid, salvianolic acid B, and 4-coumaric acid within 50 minutes. The linear relationships of the five peak areas and their concentrations are good (R2> 0.9997). The precision RSD values are all less than 1.0%. The reproducibility RSD values are all less than 1.3%. The stability RSD values are all less than 2.2%. The recovery values ranged from 92.4% to 99.4%. This method is simple, accurate, and reproducible. It can be used for the determination of sodium danshensu, protocatechuic aldehyde, rosmarinic acid, salvianolic acid B, and 4-coumaric acid in Danhong injection. 展开更多
关键词 Danhong Injection high performance liquid chromatography Phenolic Acid FLAVONOIDS
下载PDF
Quantitative Analysis of Components in OC-CS Sprays by High Performance Liquid Chromatography with Double Wavelength UV Detection
9
作者 孙立权 陈振贺 +4 位作者 邱日祥 王莉晶 钱伟 耿利娜 罗爱芹 《Defence Technology(防务技术)》 SCIE EI CAS 2010年第3期216-219,共4页
The method of reversed-phase high performance liquid chromatography was established for the determination of effective components in OC-CS spray using double wavelength UV detection.The method was utilized under follo... The method of reversed-phase high performance liquid chromatography was established for the determination of effective components in OC-CS spray using double wavelength UV detection.The method was utilized under following conditions:a column of Kromasil C18(250 mm × 4.6 mm,5 μm),mobile phase consisting of methanol/water(80 /20) at a flow rate of 0.8 mL/min,column temperature of 25 ℃,and the UV detection at 227 nm and 300 nm.Three key components in OC-CS spray could be distinguished clearly,including o-chlorobenzalmalononitrile(CS),oleoresin capsicum(OC) and dihydrocapsaicin(DC).This method has the advantages of fast,simple and satisfactory linear relationship between UV absorption and concentration.It may be considered to turn into a standard method for detection of related components in the spray. 展开更多
关键词 analytical chemistry OC-CS sprays o-chlorobenzalmalononitrile oleoresin capsicum dihydrocapsaicin high performance liquid chromatography
下载PDF
High Performance Liquid Chromatography Separation and Simultaneous Fluorometric Detection of Trace Amount of Polyamines in Cell Culture Media
10
作者 王淳本 雷景迈 +1 位作者 柴锡禄 何善述 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 1995年第2期125-128,共4页
A highly sensitive and precise method for the determination of the polyamines (including putrescine, spermidine and spermine) in cell culture media is described. The samples were concentrated by C18 column and the pol... A highly sensitive and precise method for the determination of the polyamines (including putrescine, spermidine and spermine) in cell culture media is described. The samples were concentrated by C18 column and the polyamines were converted to fluorometric derivatives with DNS-Cl. The polyamine derivatives were then completely separated by HPLC and determined by simultaneous fluorometric detection. The CV of intragroup and intergroup were 2. 49 %-4. 26% and 4. 29 %-5. 16 %, respectively. The rate of recovery was 103%- 99%. There was trace amount of polyamines detected by this method in the media of F12, 8900, RPMI1640, DMEM and M199 even without incubation with cells. So this method can be used for detecting the changes of polyamines in a medium before and after incubation with cells. It is helpful for the researches on the regulation of cell proliferation by polyamines. 展开更多
关键词 medium PUTRESCINE SPERMIDINE SPERMINE high performance liquid chromatography fluorospectrophotometry
下载PDF
Determination of Quinolone Antibiotics in Water Using Solid Phase Extraction-High Performance Liquid Chromatography-Fluorescence Method
11
作者 WANG Qiao-jun YI Ru-han MO Ce-hui 《Animal Husbandry and Feed Science》 CAS 2011年第2期45-48,共4页
[Objective] To develop a solid phase extraction-high performance liquid chromatography-fluorescence method for determination of quin- olone antibiotics in water. [ Metbod] The standard curves of four quinolones (norf... [Objective] To develop a solid phase extraction-high performance liquid chromatography-fluorescence method for determination of quin- olone antibiotics in water. [ Metbod] The standard curves of four quinolones (norfloxacin, ciprofloxacin, Iomefloxacin and enrofloxacin) were pre- pared. The detection limit in water and recovery were determined. The water samples collected from different areas, river and tap water were trea- ted using solid-phese extraction method and analyzed by high performance liquid chromatography. Then the concentration of quinolones antibiotics was determined by fluorescence method. [ Result] The detection limit of quinolone antibiotics in water was 0.083 -0.248 μg/L, and their recovery was 63.7% -134.1%. The four quinolone antibiotics at different levels were detected in various water samples, and the total concentration of quin- olone antibiotics was 0.045 -3.969 μg/L. The total concentration of quinolone antibiotics was higher in the water samples collected from rivers in Shenzhen area than in the sewage samples. The four quinolone antibiotics could be detected in all tap water samples. [ CoaduLsion ] The solid phase extraction-high performance liquid chromatography-fluorescence method is feasible and effective to detect quinolones in water. In addition, this method needs low cost and can meet requirements of daily monitorina and analysis. 展开更多
关键词 Solid-phase extraction high performance liquid chromatography WATER Quinolone antibiotics
下载PDF
Trace Determination of Tamoxifen in Biological Fluids Using Hollow Fiber Liquid-Phase Microextraction Followed by High-Performance Liquid Chromatography-Ultraviolet Detection
12
作者 Amir Kashtiaray Hadi Farahani +2 位作者 Sharareh Farhadi Bertrand Rochat Hamid Reza Sobhi 《American Journal of Analytical Chemistry》 2011年第4期429-436,共8页
The applicability of hollow fiber liquid-phase microextraction (HF-LPME) combined with high-performance liquid chromatography-ultraviolet detection (HPLC-UV) was evaluated for the extraction and determination of tamox... The applicability of hollow fiber liquid-phase microextraction (HF-LPME) combined with high-performance liquid chromatography-ultraviolet detection (HPLC-UV) was evaluated for the extraction and determination of tamoxifen (TAM) in biological fluids including human urine and plasma. The drug was extracted from a 15 mL aqueous sample (source phase;SP) into an organic phase impregnated in the pores of the hollow fiber (membrane phase;MP) followed by the back-extraction into a second aqueous solution (receiving phase;RP) located in the lumen of the hollow fiber. The effects of several factors such as the nature of organic solvent, compositions of SP and RP solutions, extraction time, ionic strength and stirring rate on the extraction efficiency were examined and optimized. An enrichment factor of 360 along with substantial sample clean up was obtained under the optimized conditions. The calibration curve showed linearity in the range of 1 - 500 ng?mL–1 and the limit of detection was found to be 0.5 ng?mL–1 in aqueous medium. A reasonable relative recovery (≥89%) and satisfactory intra-assay (3.7% - 4.2%, n = 3) and inter-assay (7.5% - 7.8%, n = 3) precision illustrated good performance of the analytical procedure in spiked human urine and plasma samples. 展开更多
关键词 high-performance liquid chromatography-Ultraviolet detection HOLLOW Fiber liquid-PHASE MICROEXTRACTION Human URINE And Plasma Samples TAMOXIFEN
下载PDF
Determination of Organic Acids in Root Exudates by High Performance Liquid Chromatography: I. Development and Assessment of Chromatographic Conditions *1 被引量:4
13
作者 SHENJIANBO ZHANGFUSUO 《Pedosphere》 SCIE CAS CSCD 1998年第2期97-104,共8页
Methods for determining nine low molecular weight organic acids in root exudates were developed by using reversed phase high performance liquid chromatography with UV (ultraviolet) detection at 214 nm. The mobile ph... Methods for determining nine low molecular weight organic acids in root exudates were developed by using reversed phase high performance liquid chromatography with UV (ultraviolet) detection at 214 nm. The mobile phase was 18 mmol L -1 kH 2PO 4 adjusted to pH 2.25 with phosphoric acid and the flow rate was 0.3 mL min -1 . The analytical column was a reversed phase silica based C 18 column (Shim pack CLC ODS). The root exudates were collected through submerging the whole root system into aerated deionized water for 2 hours. The filtered exudate solutions were concentrated to dryness by rotary evaporation at 40 °C, dissolved in 10 mL mobile phase. The chromatographic conditions of organic acid determination were analyzed. The results showed that there was a high selectivity and sensitivity in the organic acid determination by reversed phase high performance liquid chromatography. Coefficients of variation for organic acid determination were lower than 10% except lactic acid. The recoveries were consistently between 80.1% to 108.3%. Detection limits were approximately 0.05 to 4.5 mg L -1 for organic acids except succinic acid with the detection limit of 7.0 mg L -1 . Phosphorus deficiency may contribute to the release of organic acids in soybean root exudates especially malic, lactic and citric acids. 展开更多
关键词 high performance liquid chromatography organic acids root exudates SOYBEAN
下载PDF
Determination of AF and AFG in Red Ginseng by High Performance Liquid Chromatography with Evaporative Light Scattering Detector (HPLC-ELSD) 被引量:2
14
作者 Chen Wei He Da Shao Ying 《Animal Husbandry and Feed Science》 CAS 2019年第5期131-134,共4页
[Objective]The paper was to establish a method for determining AF and AFG in red ginseng.[Method]A new simple,rapid and sensitive method for simultaneous determination of two amadori compounds,arginyl-fructose(AF)and ... [Objective]The paper was to establish a method for determining AF and AFG in red ginseng.[Method]A new simple,rapid and sensitive method for simultaneous determination of two amadori compounds,arginyl-fructose(AF)and arginyl-fructosyl-glucose(AFG),in extracts of three kinds of ginseng preparations was developed and validated using high performance liquid chromatography with evaporative light scattering detector(HPLC-ELSD).Two target analytes were efficiently separated by Prevail CTM18 column(4.6 mm×250 mm,5μm)at the flow rate of 0.8 mL/min within 15 min of single chromatographic run.[Result]Under optimized conditions,the detection limits were 0.015 and 0.02 mg/mL for AF and AFG,respectively.Calibration curves of peak area for two analytes were linear over three orders of magnitude with the correlation coefficients greater than 0.999.The average recoveries,precision,reproducibility and stability for two analytes(AF and AFG)were 99.5% and 100.9%,0.43% and 0.47%,0.46% and 0.43%,0.41% and 0.49%,respectively.[Conclusion]This method was successfully applied for quantifying AF and AFG in red ginseng and the method was efficient,sensitive and accurate. 展开更多
关键词 high performance liquid chromatography Evaporative light scattering detector Amadori compounds Red ginseng
下载PDF
Quantification of six bioactive compounds in Zhenqi Fuzheng preparation by high-performance liquid chromatography coupled with diode array detector and evaporative light scattering detector 被引量:4
15
作者 Yi-Kai Shi Fang Cui +3 位作者 Fang-Di Hu Ying-Yan Bi Yu-Feng Ma Shi-Lan Feng 《Journal of Pharmaceutical Analysis》 SCIE CAS 2011年第1期20-25,共6页
A simple and accurate high-performance liquid chromatography(HPLC)coupled with diode array detector(DAD)and evaporative light scattering detector(ELSD)was established for the determination of six bioactive compo... A simple and accurate high-performance liquid chromatography(HPLC)coupled with diode array detector(DAD)and evaporative light scattering detector(ELSD)was established for the determination of six bioactive compounds in Zhenqi Fuzheng preparation(ZFP).The monitoring wavelengths were 254,275 and 328 nm.Under the optimum conditions,good separation was achieved,and the assay was fully validated in respect of precision,repeatability and accuracy.The proposed method was successfully applied to quantify the six ingredients in 31 batches of ZFP samples and evaluate the variation by hierarchical cluster analysis(HCA),which demonstrated significant variations on the content of these compounds in the samples from different manufacturers with different preparation procedures.The developed HPLC method can be used as a valid analytical method to evaluate the intrinsic quality of this preparation. 展开更多
关键词 high-performance liquid chromatography(HPLC) diode array detector(DAD) evaporative light scattering detector(ELSD) Zhenqi Fuzheng preparation quantification hierarchical cluster analysis
下载PDF
High Performance Liquid Chromatography-Electrospray Ionization-Mass Spectrometric Analysis of Bilobalide and Ginkgolides in Ginkgo biloba L. Leaves 被引量:1
16
作者 卢定强 韦萍 +1 位作者 欧阳平凯 陈钧 《Journal of Chinese Pharmaceutical Sciences》 CAS 2002年第2期26-30,共5页
The ginkgo terpenoids including bilobalide and ginkgolides are the main pharmaceutical components in the leaves or extracts of Ginkgo biloba L. In this paper, the analysis of bilobalide and ginkgolides in leaves of Gi... The ginkgo terpenoids including bilobalide and ginkgolides are the main pharmaceutical components in the leaves or extracts of Ginkgo biloba L. In this paper, the analysis of bilobalide and ginkgolides in leaves of Ginkgo biloba L. by high performance liquid chromatography (HPLC)-electrospray ionization (ESI)-mass spectrometry (MS) was carried out. The separation was performed on Inertsil ODS3 column with methanol-water (36:64) as mobile phase, with 1 mL·min -1 of flow rate at 35℃. Then the mass spectrum analysis was conducted by ZMD micromass electrospray ionization (ESI)-mass spectrometer (MS). The HPLC total ion chromatogram and selected ion chromatogram (with 325, 407, 423, 439 of m/z) of the sample and ESI-/MS mass spectra of the peaks in the chromatograms were obtained. So bilobalide, ginkgolide A, B, C and J in Ginkgo biloba L. leaves were identified. The method is easy and rapid, with a good accuracy. 展开更多
关键词 high performance liquid chromatography Electrospray ionization Mass spectrometry Ginkgo terpene lactones
下载PDF
Determination of neomycin in water samples by high performance anion chromatography with pulsed amperometric detection
17
作者 Bin Guan Dong Xing Yuan 《Chinese Chemical Letters》 SCIE CAS CSCD 2007年第2期201-204,共4页
A simple, fast and reliable method, using high performance anion chromatography with pulsed amperometric detection, had been developed for the analysis of neomycin in water samples. The elution and separation were car... A simple, fast and reliable method, using high performance anion chromatography with pulsed amperometric detection, had been developed for the analysis of neomycin in water samples. The elution and separation were carried out with an isocratic mobile phase, containing 10 mmol/L NaOH. The influence of the concentration and pH of the mobile phase on the separation and detection was investigated. A quadruple-potential waveform used for the detection was optimized. The detection limit of neomycin was down to 0.027 μg/mL. The linearity of neomycin calibration curve ranged from 0.050 to 0.505 μg/mL with correlation coefficient of 0.9997. R.S.D. (n = 11) was 4.0%. 展开更多
关键词 NEOMYCIN high performance anion chromatography Pulsed amperometric detection
下载PDF
Analysis of Amino Acids in Houttuynia Cordata Thunb. by High Performance Liquid Chromatography-Diode Array Detector (HPLC-DAD)
18
作者 Xuan FENG Zhannan YANG +5 位作者 Zhu ZHENG Juan HU Xiaofang WEI Honghao HUO Cheng ZHAO Quling ZHANG 《Medicinal Plant》 CAS 2019年第2期28-34,共7页
[Objectives] The biologically active compounds of Houttuynia cordata Thunb. as a medicinal and edible plant are well documented. However, amino acid as an important indicator of the value of H. cordata is little repor... [Objectives] The biologically active compounds of Houttuynia cordata Thunb. as a medicinal and edible plant are well documented. However, amino acid as an important indicator of the value of H. cordata is little reported. [Methods] Amino acids of the H. cordata were analysed by pre-column derivatization with 2,4-dinitrochlorobenzne(CDNB) coupled to HPLC/DAD. The optimized conditions of the amino acids derivatized by CDNB were followed: 110 ℃ of hydrolysis temperature, 1∶12 of the equivalent proportion between amino acid and CDNB, 80 min of derivatization reaction time and 80 ℃ of derivatization reaction temperature. The method was used to determine the amino acids of H. cordata samples from 11 different geographical sites in Guizhou. [Results] The results suggested that the contents of 17 amino acids were quite variable at different H. cordata samples. [Conclusions] This study will provide a basis for the quality evaluation of H. cordata nutrition. 展开更多
关键词 Houttuynia cordata Thunb. AMINO acid high performance liquid chromatography MEDICINAL plant
下载PDF
Determination of trans-resveratrol in mouse liver by high performance liquid chromatography
19
作者 姚倩 侯世祥 +3 位作者 何希辉 张瑄 颜军 苟小军 《Journal of Chinese Pharmaceutical Sciences》 CAS 2008年第2期158-162,共5页
To develop a sensitive high performance liquid chromatography (HPLC) assay for the determination of trans-resveratrol in mouse liver. The whole liver of a mouse was removed from the body, homogenated, and extracted ... To develop a sensitive high performance liquid chromatography (HPLC) assay for the determination of trans-resveratrol in mouse liver. The whole liver of a mouse was removed from the body, homogenated, and extracted by ethyl acetate. The organic layer was isolated and evaporated to dryness, the residue was reconstituted in 0.2 mL mobile phase for centrifugation, and 50 uL of the supernatant was injected into the/-IPLC instrument. The sample was separated on a Shimadzu ODS column (150 mm × 4.6 mm, 5 um) at 35 ℃ and detected by ultraviolet (UV) detector at the wavelength of 305 nm. The mobile phase consisted of methanol and 0.1 mol/L acetic acid (4:6, v/v) with the flow-rote at 1 mL/min. The limit of detection was 3.0 ng/g in liver homogenate with a signal/noise ratio of 3:1. The linear range of the calibration curve was 5.0-120.0 ng/g. The mean recoveries at the concentrations of 6, 10 and 80 ng/g were 102%, 96.0% and 91.5%, respectively. The RSDs for inter- and intra-day assays were less than 5%. Compared with other reported methods, this method was faster and more sensitive. It was also proved to be of good linearity, selectivity, accuracy and precision, and can be efficiently applied to the pharmacoldnetic study of trans-resveratrol in mouse liver. 展开更多
关键词 high performance liquid chromatography TRANS-RESVERATROL Mouse liver
下载PDF
Novel method for the determination of five carbamate pesticides in water samples by dispersive liquid-liquid microextraction combined with high performance liquid chromatography 被引量:10
20
作者 Zhi Mei Liu Xiao Huan Zang Wei Hua Liu Chun Wang Zhi Wang 《Chinese Chemical Letters》 SCIE CAS CSCD 2009年第2期213-216,共4页
A novel method for the determination of five carbamate pesticides (metolcarb, carbofuran, carbaryl, isoprocard and diethofencard) in water samples was developed by dispersive liquid-liquid microextraction (DLLME) ... A novel method for the determination of five carbamate pesticides (metolcarb, carbofuran, carbaryl, isoprocard and diethofencard) in water samples was developed by dispersive liquid-liquid microextraction (DLLME) coupled with high performance liquid chromatography-diode array detector (HPLC-DAD). Some experimental parameters that influence the extraction efficiency were studied and optimized to obtain the best extraction results. Under the optimum conditions for the method, the calibration curve was linear in the concentration range from 5 to 1000 ng mL^-1 for all the five carbamate pesticides, with the correlation coefficients (r^2) varying from 0.9984 to 0.9994. Good enrichment factors were achieved ranging from 80 to 177- fold, depending on the compound. The limits of detection (LODs) (S/N = 3) were ranged from 0.1 to 0.5 ng mL^-1. The method has been successfully applied to the analysis of the pesticide residues in environmental water samples. 展开更多
关键词 Carbamate pesticides high performance liquid chromatography Diode array detection Dispersive liquid-liquid microextraction Water samples
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部