期刊文献+
共找到31,483篇文章
< 1 2 250 >
每页显示 20 50 100
The diagnostic value of high-frequency ultrasonography in biliary atresia 被引量:13
1
作者 Li-Ping Jiang Yun-Chao Chen +5 位作者 Lu Ding Xiao-Ling Liu Kai-Yan Li Dao-Zhong Huang Ai-Yun Zhou Qing-Ping Zhang 《Hepatobiliary & Pancreatic Diseases International》 SCIE CAS 2013年第4期415-422,共8页
BACKGROUND: It is a globally challenging problem to differentially diagnose biliary atresia (BA) from other disease processes causing infantile cholestatic jaundice. The high frequency ultrasonography (HUS) yields muc... BACKGROUND: It is a globally challenging problem to differentially diagnose biliary atresia (BA) from other disease processes causing infantile cholestatic jaundice. The high frequency ultrasonography (HUS) yields much improved spatial resolution and therefore, might show better image in BA diagnostic examination. The present study was to evaluate the HUS on the diagnosis of BA in infants with jaundice. METHODS: Fifty-one infants with neonatal jaundice were scanned with ultrasonography. Images included gallbladder, bile duct, right hepatic artery (RHA), portal vein (PV) and triangular cord (TC) sign, magnetic resonance imaging and additionally laboratory tests and histopathology reports were assessed. RESULTS: Twenty-three BA and 28 non-BA cases were con firmed. The sensitivity, specificity, and accuracy of HUS were 91.3%, 92.9%, and 92.2%, respectively. All of these indices were significantly higher than those of conventional ultrasonography (P【0.01) and MR cholangiopancreatography (P【0.05). The HUS features, included a positive TC sign, an increased RHA diameter and RHA-diameter to portal-vein-diameter ratio (RHA/PV) and abnormal gallbladder, were important in the diagnosis of BA. CONCLUSION: HUS provided better imaging of BA and should be considered as a primary modality in the differential diagnosis of infantile jaundice. 展开更多
关键词 neonatal jaundice biliary atresia high-frequency ultrasonography
下载PDF
Early Detection of Lesions of Dorsal Artery of Foot in Patients with Type 2 Diabetes Mellitus by High-frequency Ultrasonography 被引量:163
2
作者 张艳容 李雯静 +3 位作者 严天慰 鲁成发 周翔 黄艳 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2009年第3期387-390,共4页
This study evaluated the value of high-frequency ultrasonograpy for early detection of dorsal artery of foot in patients with type 2 diabetes mellitus (MD). Eighty subjects including 40 patients with type 2 MD (T2D... This study evaluated the value of high-frequency ultrasonograpy for early detection of dorsal artery of foot in patients with type 2 diabetes mellitus (MD). Eighty subjects including 40 patients with type 2 MD (T2DM group) and 40 healthy volunteers (NC group) were recruited. The intima-media thickness (IMT), the inner diameter and the perfusion of dorsal artery of foot were measured by using high-frequency ultrasonograpy. Meanwhile, the parameters of vascular elasticity, including stiffness parameter (]3), pressure-strain elastic modulus (Ep), arterial compliance (AC), augment index (AI), and pulse wave conducting velocity (PWV]3) were detected by means of echo-tracking technique. The results showed that no significant difference was found in the IMT, systolic diameter (Ds), diastolic diameter (Dd) and peak systolic velocity (PSV) between T2DM and NC groups. Ep and PWVβ were increased, and AC was decreased in T2DM group as compared with those in NC group with the differences being significant (P〈0.05 for all). There was no significant difference in β and AI between T2DM and NC groups. It was concluded that high-frequency ultra- sonography in combination with echo-tracking technique is sensitive and non-invasive, and can be used for early detection of sclerosis of the lower extremity artery in patients with type 2 MD. 展开更多
关键词 high frequency ultrasonography dorsal artery of foot ELASTICITY type 2 diabetes mellitus
下载PDF
Value of high-frequency ultrasonography with virtual touch tissue quantification in diagnosis of breast pure mucinous carcinomas
3
作者 Jian Shi Guang Yang +1 位作者 Jialing Wu Wenlin Xu 《The Chinese-German Journal of Clinical Oncology》 CAS 2012年第8期445-448,共4页
Objective The aim of our study was to analyze the characters of breast pure mucinous carcinomas on highfrequency ultrasonography with virtual touch tissue quantification (VTQ).
关键词 BREAST pure mucinous carcinoma ultrasonography virtual touch tissue quantification
下载PDF
Kinematic deformation and intensity assessment of the 2021 Maduo M_(S)7.4 earthquake in Qinghai revealed by high-frequency GNSS
4
作者 Yu Li Yuebing Wang +2 位作者 Lijiang Zhao Hongbo Shi Pingping Wang 《Geodesy and Geodynamics》 EI CSCD 2024年第3期230-240,共11页
Rapid acquisition of the kinematic deformation field and seismic intensity distribution of large earthquakes is crucial for postseismic emergency rescue,disaster assessment,and future seismic risk research.The advance... Rapid acquisition of the kinematic deformation field and seismic intensity distribution of large earthquakes is crucial for postseismic emergency rescue,disaster assessment,and future seismic risk research.The advancement of GNSS observation and data processing makes it play an important role in this field,especially the high-frequency GNSS.We used the differential positioning method to calculate the 1 HZ GNSS data from 98 sites within 1000 km of the M_(S)7.4 Maduo earthquake epicenter.The kinematic deformation field and the distribution of the seismic intensity by using the peak ground velocity derived from displacement waveforms were obtained.The results show that:1)Horizontal coseismic response deformation levels ranging from 25 mm to 301 mm can be observed within a 1000 km radius from the epicenter.Coseismic response deformation on the east and west sides shows bilateral asymmetry,which markedly differs from the symmetry presented by surface rupture.2)The seismic intensity obtained through high-frequency GNSS and field investigations exhibits good consistency of the scope and orientation in the high seismic intensity area,although the former is generally slightly smaller than the latter.3)There may exist obstacles on the eastern side of the seismogenic fault.The Maduo earthquake induced a certain tectonic stress loading effect on the western Kunlun Pass-Jiangcuo fault(KPJF)and Maqin-Maqu segment,resulting in higher seismic risk in the future. 展开更多
关键词 Maduo earthquake high-frequency GNSS Kinematic deformation Seismic intensity
下载PDF
Dynamic Response of Foundations during Startup of High-Frequency Tunnel Equipment
5
作者 Dawei Ruan Mingwei Hu 《Computer Modeling in Engineering & Sciences》 SCIE EI 2024年第7期821-844,共24页
The specialized equipment utilized in long-line tunnel engineering is evolving towards large-scale,multifunctional,and complex orientations.The vibration caused by the high-frequency units during regular operation is ... The specialized equipment utilized in long-line tunnel engineering is evolving towards large-scale,multifunctional,and complex orientations.The vibration caused by the high-frequency units during regular operation is supported by the foundation of the units,and the magnitude of vibration and the operating frequency fluctuate in different engineering contexts,leading to variations in the dynamic response of the foundation.The high-frequency units yield significantly diverse outcomes under different startup conditions and times,resulting in failure to meet operational requirements,influencing the normal function of the tunnel,and causing harm to the foundation structure,personnel,and property in severe cases.This article formulates a finite element numerical computation model for solid elements using three-dimensional elastic body theory and integrates field measurements to substantiate and ascertain the crucial parameter configurations of the finite element model.By proposing a comprehensive startup timing function for high-frequency dynamic machines under different startup conditions,simulating the frequency andmagnitude variations during the startup process,and suggesting functions for changes in frequency and magnitude,a simulated startup schedule function for high-frequency machines is created through coupling.Taking into account the selection of the transient dynamic analysis step length,the dynamic response results for the lower dynamic foundation during its fundamental frequency crossing process are obtained.The validation checks if the structural magnitude surpasses the safety threshold during the critical phase of unit startup traversing the structural resonance region.The design recommendations for high-frequency units’dynamic foundations are provided,taking into account the startup process of the machine and ensuring the safe operation of the tunnel. 展开更多
关键词 Tunnel equipment high-frequency units startup conditions transient dynamics dynamic response foundation design
下载PDF
Review of the Analysis and Suppression for High-frequency Oscillations of the Grid-connected Wind Power Generation System
6
作者 Bo Pang Qi Si +4 位作者 Pan Jiang Kai Liao Xiaojuan Zhu Jianwei Yang Zhengyou He 《CES Transactions on Electrical Machines and Systems》 EI CSCD 2024年第2期127-142,共16页
High-frequency oscillation(HFO)of gridconnected wind power generation systems(WPGS)is one of the most critical issues in recent years that threaten the safe access of WPGS to the grid.Ensuring the WPGS can damp HFO is... High-frequency oscillation(HFO)of gridconnected wind power generation systems(WPGS)is one of the most critical issues in recent years that threaten the safe access of WPGS to the grid.Ensuring the WPGS can damp HFO is becoming more and more vital for the development of wind power.The HFO phenomenon of wind turbines under different scenarios usually has different mechanisms.Hence,engineers need to acquire the working mechanisms of the different HFO damping technologies and select the appropriate one to ensure the effective implementation of oscillation damping in practical engineering.This paper introduces the general assumptions of WPGS when analyzing HFO,systematically summarizes the reasons for the occurrence of HFO in different scenarios,deeply analyses the key points and difficulties of HFO damping under different scenarios,and then compares the technical performances of various types of HFO suppression methods to provide adequate references for engineers in the application of technology.Finally,this paper discusses possible future research difficulties in the problem of HFO,as well as the possible future trends in the demand for HFO damping. 展开更多
关键词 Damping method high-frequency oscillation STABILITY Wind power generation
下载PDF
Efficient activation of the Co/SBA-15catalyst by high-frequency AC-DBD plasma thermal effects for toluene removal
7
作者 李越 姜楠 +5 位作者 刘政妍 秦亮 彭邦发 王荣刚 孙玉荣 李杰 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第8期84-94,共11页
Dielectric barrier discharge(DBD)plasma excited by a high-frequency alternating-current(AC)power supply is widely employed for the degradation of volatile organic compounds(VOCs).However,the thermal effect generated d... Dielectric barrier discharge(DBD)plasma excited by a high-frequency alternating-current(AC)power supply is widely employed for the degradation of volatile organic compounds(VOCs).However,the thermal effect generated during the discharge process leads to energy waste and low energy utilization efficiency.In this work,an innovative DBD thermally-conducted catalysis(DBD-TCC)system,integrating high-frequency AC-DBD plasma and its generated thermal effects to activate the Co/SBA-15 catalyst,was employed for toluene removal.Specifically,Co/SBA-15 catalysts are closely positioned to the ground electrode of the plasma zone and can be heated and activated by the thermal effect when the voltage exceeds 10 k V.At12.4 k V,the temperature in the catalyst zone reached 261℃ in the DBD-TCC system,resulting in an increase in toluene degradation efficiency of 17%,CO_(2)selectivity of 21.2%,and energy efficiency of 27%,respectively,compared to the DBD system alone.In contrast,the DBD thermally-unconducted catalysis(DBD-TUC)system fails to enhance toluene degradation due to insufficient heat absorption and catalytic activation,highlighting the crucial role of AC-DBD generated heat in the activation of the catalyst.Furthermore,the degradation pathway and mechanism of toluene in the DBD-TCC system were hypothesized.This work is expected to provide an energy-efficient approach for high-frequency AC-DBD plasma removal of VOCs. 展开更多
关键词 high-frequency alternating-current power thermal effect dielectric barrier discharge toluene degradation Co/SBA-15 catalysts
下载PDF
Effects of unilateral superimposed high-frequency jet ventilation on porcine hemodynamics and gas exchange during one-lung flooding
8
作者 Thomas Lesser Frank Wolfram +1 位作者 Conny Braun Reiner Gottschall 《World Journal of Experimental Medicine》 2024年第1期88-99,共12页
BACKGROUND Superimposed high-frequency jet ventilation(SHFJV)is suitable for respiratory motion reduction and essential for effective lung tumor ablation.Fluid filling of the target lung wing one-lung flooding(OLF)is ... BACKGROUND Superimposed high-frequency jet ventilation(SHFJV)is suitable for respiratory motion reduction and essential for effective lung tumor ablation.Fluid filling of the target lung wing one-lung flooding(OLF)is necessary for therapeutic ultrasound applications.However,whether unilateral SHFJV allows adequate hemodynamics and gas exchange is unclear.AIM To compared SHFJV with pressure-controlled ventilation(PCV)during OLF by assessing hemodynamics and gas exchange in different animal positions.METHODS SHFJV or PCV was used alternatingly to ventilate the non-flooded lungs of the 12 anesthetized pigs during OLF.The animal positions were changed from left lateral position to supine position(SP)to right lateral position(RLP)every 30 min.In each position,ventilation was maintained for 15 min in both modalities.Hemodynamic variables and arterial blood gas levels were repeatedly measured.RESULTS Unilateral SHFJV led to lower carbon dioxide removal than PCV without abnormally elevated carbon dioxide levels.SHFJV slightly decreased oxygenation in SP and RLP compared with PCV;the lowest values of PaO_(2) and PaO_(2)/FiO_(2) ratio were found in SP[13.0;interquartile range(IQR):12.6-5.6 and 32.5(IQR:31.5-38.9)kPa].Conversely,during SHFJV,the shunt fraction was higher in all animal positions(highest in the RLP:0.30).CONCLUSION In porcine model,unilateral SHFJV may provide adequate ventilation in different animal positions during OLF.Lower oxygenation and CO_(2) removal rates compared to PCV did not lead to hypoxia or hypercapnia.SHFJV can be safely used for lung tumor ablation to minimize ventilation-induced lung motion. 展开更多
关键词 One-lung ventilation Unilateral superimposed high-frequency jet ventilation One-lung flooding
下载PDF
Therapeutic efficacy of methylprednisolone sodium succinate via diverse administration routes for mid-to high-frequency sudden sensorineural hearing loss
9
作者 Xiang-Da Meng Ting-Ting Li Li-Min Deng 《World Journal of Clinical Cases》 SCIE 2024年第18期3321-3331,共11页
BACKGROUND Sudden sensorineural hearing loss(SSNHL),characterized by a rapid and unexplained loss of hearing,particularly at moderate to high frequencies,presents a significant clinical challenge.The therapeutic use o... BACKGROUND Sudden sensorineural hearing loss(SSNHL),characterized by a rapid and unexplained loss of hearing,particularly at moderate to high frequencies,presents a significant clinical challenge.The therapeutic use of methylprednisolone sodium succinate(MPSS)via different administration routes,in combination with conventional medications,remains a topic of interest.AIM To compare the therapeutic efficacy of MPSS administered via different routes in combination with conventional drugs for the treatment of mid-to high-frequency SSNHL.METHODS The medical records of 109 patients with mid-to high-frequency SSNHL were analyzed.The patients were divided into three groups based on the route of administration:Group A[intratympanic(IT)injection of MPSS combined with mecobalamin and Ginkgo biloba leaf extract injection],Group B(intravenous injection of MPSS combined with mecobalamin and Ginkgo biloba leaf extract injection),and Group C(single IT injection of MPSS).The intervention effects were compared and analyzed.RESULTS The posttreatment auditory thresholds in Group A(21.23±3.34)were significantly lower than those in Groups B(28.52±3.36)and C(30.23±4.21;P<0.05).Group A also exhibited a significantly greater speech recognition rate(92.23±5.34)than Groups B and C.The disappearance time of tinnitus,time to hearing recovery,and disappearance time of vertigo in Group A were significantly shorter than those in Groups B and C(P<0.05).The total effective rate in Group A(97.56%)was significantly greater than that in Groups B and C(77.14%and 78.79%,χ^(2)=7.898,P=0.019).Moreover,the incidence of adverse reactions in Groups A and C was significantly lower than that in Group B(4.88%,3.03%vs 2.57%,χ^(2)=11.443,P=0.003),and the recurrence rate in Group A was significantly lower than that in Groups B and C(2.44%vs 20.00%vs 21.21%,χ^(2)=7.120,P=0.028).CONCLUSION IT injection of MPSS combined with conventional treatment demonstrates superior efficacy and safety compared to systemic administration via intravenous infusion and a single IT injection of MPSS.This approach effectively improves patients'hearing and reduces the risk of disease recurrence. 展开更多
关键词 Sudden loss of hearing at middle-and high-frequency of the descending type Methylprednisolone sodium succinate Intratympanic injection Intravenous injection
下载PDF
Radio-frequency measurements of energetic-electron-driven emissions using high-frequency magnetic probe on XuanLong-50 spherical torus
10
作者 王明远 伦秀春 +3 位作者 薄晓坤 刘兵 刘阿娣 石跃江 《Plasma Science and Technology》 SCIE EI CAS CSCD 2023年第4期33-38,共6页
A high-frequency magnetic probe is designed and developed on the XuanL ong-50(EXL-50)spherical torus to measure high-frequency magnetic field fluctuation.The magnetic loop,radio filters,radio-frequency limiter,and dat... A high-frequency magnetic probe is designed and developed on the XuanL ong-50(EXL-50)spherical torus to measure high-frequency magnetic field fluctuation.The magnetic loop,radio filters,radio-frequency limiter,and data acquisition system of the probe are comprehensively examined.The fluctuation data from the EXL-50 plasma are analyzed in the time–frequency domain using fast Fourier transforms.Moreover,distinct high-frequency instabilities are detected using this diagnostic system.In particular,significant frequency chirping is observed,which is consistent with the bumpon-tail drive instability predicted using the Berk–Breizman model. 展开更多
关键词 high-frequency magnetic probe high-frequency instabilities XuanLong-50
下载PDF
Endoscopic ultrasonography-related diagnostic accuracy and clinical significance on small rectal neuroendocrine neoplasms 被引量:1
11
作者 Jun Weng Yu-Fan Chen +5 位作者 Shu-Han Li Yan-Hua Lv Ruo-Bing Chen Guo-Liang Xu Shi-Yong Lin Kun-Hao Bai 《World Journal of Gastroenterology》 SCIE CAS 2024年第7期774-778,共5页
This research aimed to examine the diagnostic accuracy and clinical significance of endoscopic ultrasonography(EUS)in the context of small rectal neuroendocrine neoplasms(NENs).A total of 108 patients with rectal sube... This research aimed to examine the diagnostic accuracy and clinical significance of endoscopic ultrasonography(EUS)in the context of small rectal neuroendocrine neoplasms(NENs).A total of 108 patients with rectal subepithelial lesions(SELs)with a diameter of<20 mm were included in the analysis.The diagnosis and depth assessment of EUS was compared to the histology findings.The prevalence of NENs in rectal SELs was 78.7%(85/108).The sensitivity of EUS in detecting rectal NENs was 98.9%(84/85),while the specificity was 52.2%(12/23).Overall,the diagnostic accuracy of EUS in identifying rectal NENs was 88.9%(96/108).The overall accuracy rate for EUS in assessing the depth of invasion in rectal NENs was 92.9%(78/84).Therefore,EUS demonstrates reasonable diagnostic accuracy in detecting small rectal NENs,with good sensitivity but inferior specificity.EUS may also assist physicians in assessing the depth of invasion in small rectal NENs before endoscopic excision. 展开更多
关键词 Rectal neuroendocrine neoplasms Endoscopic ultrasonography DIAGNOSIS Depth of invasion
下载PDF
Tuning magneto-dielectric properties of Co_(2)Z ferrites via Gd doping for high-frequency applications
12
作者 武剑 卢冰 +6 位作者 张颖 陈一鑫 孙凯 陈大明 李强 刘颖力 李颉 《Chinese Physics B》 SCIE EI CAS CSCD 2023年第9期468-473,共6页
Magneto-dielectric properties of Co_(2)Z ferrite materials are tuned via Gd doping for applications in high-frequency antennas and filters in the present work.Ba_(3)Co_(2)Fe_(24-x)Gd_(x)O_(41)(x=0.00,0.05,0.10,0.15,an... Magneto-dielectric properties of Co_(2)Z ferrite materials are tuned via Gd doping for applications in high-frequency antennas and filters in the present work.Ba_(3)Co_(2)Fe_(24-x)Gd_(x)O_(41)(x=0.00,0.05,0.10,0.15,and 0.20)materials are successfully prepared by using solid-state method at 925℃for 4 h with 2.5-wt%Bi_(2)O_(3)sintering aids.The content of Gd^(3+)ion can affect micromorphology,grain size,bulk density,and magneto-dielectric properties of the ferrite.With Gd^(3+)ion content increasing,saturation magnetization(Ms)first increases and then decreases.The maximum value of Ms is 44.86 emu/g at x=0.15.Additionally,sites occupied by Gd^(3+)ions can change magnetic anisotropy constant of the ferrite.Magnetocrystalline anisotropy constant(K_1)is derived from initial magnetization curve,and found to be related to spin-orbit coupling and intersublattice interactions between metal ions.The real part of magnetic permeability(μ′)and real part of dielectric permittivity(ε′)are measured in a frequency range of 10 MHz-1 GHz.When x=0.15,material has excellent magneto-dielectric properties(μ′≈12.2 andε′≈17.61),low magnetic loss(tanδμ≈0.03 at 500 MHz),and dielectric loss(tanδε≈0.04 at 500 MHz).The results show that Gd-doped Co_(2)Z ferrite has broad application prospects in multilayer filters and high-frequency antennas. 展开更多
关键词 Co_(2)Z ferrite magneto-dielectric properties Gd doping high-frequency applications
下载PDF
Intraoperative cholangio-ultrasonography(IOCUS)during hepatectomy with resection of the biliary confluence:An effective alternative to intraoperative cholangiography
13
作者 Daniele Del Fabbro Fabio Procopio +5 位作者 Jacopo Galvanin Guido Costa Simone Famularo Angela Palmisano Matteo Donadon Guido Torzilli 《Hepatobiliary & Pancreatic Diseases International》 SCIE CAS CSCD 2024年第4期417-420,共4页
Intraoperative ultrasonography(IOUS)in hepatobiliary surgery is well known as an essential tool for radical and safe hepatectomies,allowing to perform parenchymal sparing surgery and,as consequence,to expand the surgi... Intraoperative ultrasonography(IOUS)in hepatobiliary surgery is well known as an essential tool for radical and safe hepatectomies,allowing to perform parenchymal sparing surgery and,as consequence,to expand the surgical indications for patients otherwise considered unresectable.Nevertheless,since many years,despite its effectiveness in the study of vascular anatomy of the liver,the gold standard for the assessment of biliary anatomy during surgery is intraoperative cholangiography(IOC),which is used for the validation of preoperative imaging as well as for guiding reconstruction in case of bile duct injury or resection. 展开更多
关键词 anatomy BILIARY ultrasonography
下载PDF
Relationship between neonatal respiratory distress syndrome pulmonary ultrasonography and respiratory distress score,oxygenation index,and chest radiography grading
14
作者 Hai Yang Li-Jun Gao +5 位作者 Jing Lei Qiang Li Liu Cui Xiao-Hua Li Wu-Xuan Yin Sen-Hua Tian 《World Journal of Clinical Cases》 SCIE 2024年第20期4154-4165,共12页
BACKGROUND Accurate condition assessment is critical for improving the prognosis of neonatal respiratory distress syndrome(RDS),but current assessment methods for RDS pose a cumulative risk of harm to neonates.Thus,a ... BACKGROUND Accurate condition assessment is critical for improving the prognosis of neonatal respiratory distress syndrome(RDS),but current assessment methods for RDS pose a cumulative risk of harm to neonates.Thus,a less harmful method for assessing the health of neonates with RDS is needed.AIM To analyze the relationships between pulmonary ultrasonography and respiratory distress scores,oxygenation index,and chest X-ray grade of neonatal RDS to identify predictors of neonatal RDS severity.METHODS This retrospective study analyzed the medical information of 73 neonates with RDS admitted to the neonatal intensive care unit of Liupanshui Maternal and Child Care Service Center between April and December 2022.The pulmonary ultrasonography score,respiratory distress score,oxygenation index,and chest Xray grade of each newborn before and after treatment were collected.Spearman correlation analysis was performed to determine the relationships among these values and neonatal RDS severity.RESULTS The pulmonary ultrasonography score,respiratory distress score,oxygenation index,and chest X-ray RDS grade of the neonates were significantly lower after treatment than before treatment(P<0.05).Spearman correlation analysis showed that before and after treatment,the pulmonary ultrasonography score of neonates with RDS was positively correlated with the respiratory distress score,oxygenation index,and chest X-ray grade(ρ=0.429–0.859,P<0.05).Receiver operating characteristic curve analysis indicated that pulmonary ultrasonography screening effectively predicted the severity of neonatal RDS(area under the curve=0.805–1.000,P<0.05).CONCLUSION The pulmonary ultrasonography score was significantly associated with the neonatal RDS score,oxygenation index,and chest X-ray grade.The pulmonary ultrasonography score was an effective predictor of neonatal RDS severity. 展开更多
关键词 Neonatal respiratory distress syndrome Pulmonary ultrasonography ultrasonography score Respiratory distress score Oxygenation index Chest X-ray grading
下载PDF
Beta-HCG Levels and Ovarian Ultrasonography Results among Non-Pregnant Women of Reproductive Age in Port Harcourt, Nigeria: A Cross-Sectional Study
15
作者 Celine C. Agonsi Francis Anacletus +2 位作者 Joel Aluko Chinemerem Eleke Joy C. Samuel 《Journal of Biosciences and Medicines》 2024年第5期233-241,共9页
Background: Certain ovarian cancers that were previously common in postmenopausal women are now increasingly observed in women of reproductive age. The research on using β-HCG as a diagnostic biomarker for ovarian ca... Background: Certain ovarian cancers that were previously common in postmenopausal women are now increasingly observed in women of reproductive age. The research on using β-HCG as a diagnostic biomarker for ovarian cancer in women of reproductive age is ongoing. Aim: This study assessed the level of serum β-HCG in non-pregnant women of reproductive age and determined its potential association with suspicious ovarian ultrasonography results. Methods: The study was conducted in Port Harcourt, Nigeria. This study adopted a cross-sectional design on a quota sample of 224 case notes of women aged 18 - 40 years obtained from eight diagnostic centres. A data extraction form was used for data collection. Data analysis employed descriptive statistics, Chi-square, Fisher’s exact test, and Odds Ratio at 95% confidence and 5% significance levels. Results: About 5.8% of the participants exhibited detectable levels of serum β-HCG above 5 IU/L (World Health Organization reference) at a mean concentration of 5.87 (±1.75) IU/L. About 4.0% of the participants had suspicious ovarian lesions identified through ultrasonography. Participants with elevated serum β-HCG levels above the WHO reference were 59 times more likely to have suspicious ovarian lesions (Odds ratio: 59.4, 95%CI: 12.3 - 287.8, p β-HCG level and age (p = 0.041) as well as parity (p Conclusion: Serum β-HCG levels above the WHO reference in non-pregnant women were associated with suspicious ovarian lesions. More rigorous primary research, systematic reviews, and meta-analyses are needed to confirm the findings of this study. 展开更多
关键词 Biomarkers Ovarian Cancer PREGNANCY ultrasonography
下载PDF
Double contrast-enhanced ultrasonography improves diagnostic accuracy of T staging compared with multi-detector computed tomography in gastric cancer patients
16
作者 Yan-Fen Xu Hui-Yun Ma +4 位作者 Gui-Ling Huang Yu-Ting Zhang Xue-Yan Wang Ming-Jie Wei Xiao-Qing Pei 《World Journal of Gastroenterology》 SCIE CAS 2024年第23期3005-3015,共11页
BACKGROUND Gastric cancer(GC)is the most common malignant tumor and ranks third for cancer-related deaths among the worldwide.The disease poses a serious public health problem in China,ranking fifth for incidence and ... BACKGROUND Gastric cancer(GC)is the most common malignant tumor and ranks third for cancer-related deaths among the worldwide.The disease poses a serious public health problem in China,ranking fifth for incidence and third for mortality.Knowledge of the invasive depth of the tumor is vital to treatment decisions.AIM To evaluate the diagnostic performance of double contrast-enhanced ultrasonography(DCEUS)for preoperative T staging in patients with GC by comparing with multi-detector computed tomography(MDCT).METHODS This single prospective study enrolled patients with GC confirmed by preoperative gastroscopy from July 2021 to March 2023.Patients underwent DCEUS,including ultrasonography(US)and intravenous contrast-enhanced ultrasonography(CEUS),and MDCT examinations for the assessment of preoperative T staging.Features of GC were identified on DCEUS and criteria developed to evaluate T staging according to the 8th edition of AJCC cancer staging manual.The diagnostic performance of DCEUS was evaluated by comparing it with that of MDCT and surgical-pathological findings were considered as the gold standard.RESULTS A total of 229 patients with GC(80 T1,33 T2,59 T3 and 57 T4)were included.Overall accuracies were 86.9%for DCEUS and 61.1%for MDCT(P<0.001).DCEUS was superior to MDCT for T1(92.5%vs 70.0%,P<0.001),T2(72.7%vs 51.5%,P=0.041),T3(86.4%vs 45.8%,P<0.001)and T4(87.7%vs 70.2%,P=0.022)staging of GC.CONCLUSION DCEUS improved the diagnostic accuracy of preoperative T staging in patients with GC compared with MDCT,and constitutes a promising imaging modality for preoperative evaluation of GC to aid individualized treatment decision-making. 展开更多
关键词 Double contrast-enhanced ultrasonography Multi-detector computed tomography Gastric cancer T staging
下载PDF
Perioperative and long-term results of ultrasonography-guided single-and multiple-tract percutaneous nephrolithotomy for staghorn calculi
17
作者 Rui-Xiang Cheng Ni Dai +2 位作者 Yan-Min Wang Pei Qi Fen Chen 《World Journal of Clinical Cases》 SCIE 2024年第7期1243-1250,共8页
BACKGROUND It is possible that this condition will lead to urosepsis and progressive deterioration of renal function in the absence of surgical intervention.Several recent clinical studies have shown that multi-tract ... BACKGROUND It is possible that this condition will lead to urosepsis and progressive deterioration of renal function in the absence of surgical intervention.Several recent clinical studies have shown that multi-tract percutaneous nephrolithotomy(MPCNL)has a similar stone free rate(SFR)as standard percutaneous nephrolithotomy(S-PCNL).As a result,M-PCNL was also recommended as a treatment option for staghorn calculi.AIM To examine the perioperative and long-term results of ultrasonography-guided single-and M-PCNL.METHODS This was a retrospective cohort study.Between March 2021 and January 2022,the urology department of our hospital selected patients for the treatment of staghorn calculi using percutaneous nephrolithotomy.The primary outcomes were com plication rate and SFR,and the characteristics of patients,operative parameters,laboratory measurements were also collected.RESULTS In total,345 patients were enrolled in the study(186 in the S-PCNL group and 159 in the M-PCNL group).The SFR in the M-PCNL group was significantly higher than that in the S-PCNL group(P=0.033).Moreover,the incidence rates of hydrothorax(P=0.03)and postoperative infection(P=0.012)were higher in the M-PCNL group than in the S-PCNL group.Logistic regression analysis demonstrated that post-operative white blood cell count(OR=2.57,95%CI:1.90-3.47,P<0.001)and stone size(OR=1.59,95%CI:1.27-2.00,P<0.001)were associated with a higher overall complication rate in the S-PCNL group.Body mass index(OR=1.22,95%CI:1.06-1.40,P=0.004)and stone size(OR=1.70,95%CI:1.35-2.15,P<0.001)were associated with increased overall complications in the M-PCNL group.CONCLUSION Multiple access tracts can facilitate higher SFR while slightly increasing the incidence of acceptable complications. 展开更多
关键词 Single-tract percutaneous nephrolithotomy Multiple-tract percutaneous nephrolithotomy Staghorn calculi ultrasonography
下载PDF
A study on characteristic indexesof railway ballast bed underhigh-frequency radar
18
作者 Shilei Wang Zhan Peng +2 位作者 Guixian Liu Weile Qiang Chi Zhang 《Railway Sciences》 2023年第1期33-47,共15页
Purpose–In this paper,a high-frequency radar test system was used to collect the data of clean ballast bed and fouled ballast bed of ballasted tracks,respectively,for a quantitative evaluation of the condition of rai... Purpose–In this paper,a high-frequency radar test system was used to collect the data of clean ballast bed and fouled ballast bed of ballasted tracks,respectively,for a quantitative evaluation of the condition of railway ballast bed.Design/methodology/approach–Based on original radar signals,the time–frequency characteristics of radar signals were analyzed,five ballast bed condition characteristic indexes were proposed,including the frequency domain integral area,scanning area,number of intersections with the time axis,number of timedomain inflection points and amplitude envelope obtained by Hilbert transform,and the effectiveness and sensitivity of the indexes were analyzed.Findings–The thickness of ballast bed tested at the sleep bottom by high-frequency radar is up to 55 cm,which meets the requirements of ballast bed detection.Compared with clean ballast bed,the values of the five indexes of fouled ballast bed are larger,and the five indexes could effectively show the condition of the ballast bed.The computational efficiency of amplitude envelope obtained by Hilbert transform is 140 s$km1,and the computational efficiency of other indexes is 5 s$km1.The amplitude envelopes obtained by Hilbert transform in the subgrade sections and tunnel sections are the most sensitive,followed by scanning area.The number of intersections with the time axis in the bridge sections was the most sensitive,followed by the scanning area.The scanning area can adapt to different substructures such as subgrade,bridges and tunnels,with high comprehensive sensitivity.Originality/value–The research can provide appropriate characteristic indexes from the high-frequency radar original signal to quantitatively evaluate ballast bed condition under different substructures. 展开更多
关键词 Ballasted track Ballast bed high-frequency radar TEST Time–frequency characteristics Characteristic indexes
下载PDF
Clinical value of oral contrast-enhanced ultrasonography in diagnosis of gastric tumors
19
作者 Chuan-Yu Wang Xiao-Jing Fan +6 位作者 Fei-Liang Wang Yue-Yue Ge Zhao Cai Wei Wang Xin-Ping Zhou Jun Du De-Wei Dai 《World Journal of Gastrointestinal Oncology》 SCIE 2024年第1期110-117,共8页
BACKGROUND The incidence of gastric cancer remains high,and it is the sixth most common cancer and the fourth leading cause of cancer deaths worldwide.Oral contrastenhanced ultrasonography is a simple,non-invasive,and... BACKGROUND The incidence of gastric cancer remains high,and it is the sixth most common cancer and the fourth leading cause of cancer deaths worldwide.Oral contrastenhanced ultrasonography is a simple,non-invasive,and painless method for the diagnosis of gastric tumors.AIM To explore the diagnostic value of oral contrast-enhanced ultrasonography for the detection of gastric tumors.METHODS The screening results based on oral contrast-enhanced ultrasonography and electronic gastroscopy were compared with those of the postoperative pathological examination.RESULTS Among 42 patients with gastric tumors enrolled in the study,the diagnostic accordance rate was 95.2%for oral contrast-enhanced ultrasonography(n=40)and 90.5%for electronic gastroscopy(n=38)compared with postoperative pathological examination.The Kappa value of consistency test with pathological findings was 0.812 for oral contrast-enhanced ultrasonography and 0.718 for electronic gastroscopy,and there was no significant difference between them(P=0.397).For the TNM staging of gastric tumors,the accuracy rate of oral contrast enhanced ultrasonography was 81.9%for the overall T staging and 50%,77.8%,100%,and 100%for T1,T2,T3,and T4 staging,respectively.The sensitivity and specificity were both 100%for stages T3 and T4.The diagnostic accuracy rate of oral contrast-enhanced ultrasonography was 93.8%,80%,100%,and 100%for stages N0,N1-N3,M0,and M1,respectively.CONCLUSION The accordance rate of qualitative diagnosis by oral contrast-enhanced ultrasonography is comparable to that of gastroscopy,and it could be used as the preferred method for the early screening of gastric tumors. 展开更多
关键词 Oral contrast-enhanced ultrasonography Gastric tumor Electronic gastroscopy Controlled study Pathological examination DIAGNOSIS
下载PDF
Dynamic ultrasonography for optimizing treatment position in superior mesenteric artery syndrome:Two case reports and review of literature
20
作者 Nobuaki Hasegawa Akihiko Oka +4 位作者 Muyiwa Awoniyi Yuri Yoshida Hiroshi Tobita Norihisa Ishimura Shunji Ishihara 《World Journal of Gastroenterology》 SCIE CAS 2024年第5期499-508,共10页
BACKGROUND Superior mesenteric artery(SMA)syndrome is a rare cause of duodenal obstruction by extrinsic compression between the SMA and the aorta(SMA-Ao).Although the left lateral recumbent position is considered effe... BACKGROUND Superior mesenteric artery(SMA)syndrome is a rare cause of duodenal obstruction by extrinsic compression between the SMA and the aorta(SMA-Ao).Although the left lateral recumbent position is considered effective in the treatment of SMA syndrome,individual variations in the optimal patient position have been noted.In this report,we present two elderly cases of SMA syndrome that exhibited rapid recovery due to ultrasonographic dynamic evaluation of the optimal position for each patient.CASE SUMMARY Case 1:A 90-year-old man with nausea and vomiting.Following diagnosis of SMA syndrome by computed tomography(CT),ultrasonography(US)revealed the SMA-Ao distance in the supine position(4 mm),which slightly improved in the lateral position(5.7–7.0 mm)without the passage of duodenal contents.However,in the sitting position,the SMA-Ao distance was increased to 15 mm accompanied by improved content passage.Additionally,US indicated enhanced passage upon abdominal massage on the right side.By day 2,the patient could eat comfortably with the optimal position and massage.Case 2:An 87-year-old woman with vomiting.After the diagnosis of SMA syndrome and aspiration pneumonia by CT,dynamic US confirmed the optimal position(SMA-Ao distance was improved to 7 mm in forward-bent position,whereas it remained at 5 mm in the supine position).By day 7 when her pneumonia recovered,she could eat with the optimal position.CONCLUSION The optimal position for SMA syndrome varies among individuals.Dynamic US appears to be a valuable tool in improving patient outcomes. 展开更多
关键词 Superior mesenteric artery syndrome Wilkie’s syndrome Cast syndrome Aorto-mesenteric compass syndrome ultrasonography Case report
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部