BACKGROUND Undifferentiated pleomorphic sarcomas,also known as spindle cell sarcomas,are a relatively uncommon subtype of soft tissue sarcomas in clinical practice.CASE SUMMARY We present a case report of a 69-year-ol...BACKGROUND Undifferentiated pleomorphic sarcomas,also known as spindle cell sarcomas,are a relatively uncommon subtype of soft tissue sarcomas in clinical practice.CASE SUMMARY We present a case report of a 69-year-old female patient who was diagnosed with undifferentiated spindle cell soft tissue sarcoma on her left thigh.Surgical excision was initially performed,but the patient experienced a local recurrence following multiple surgeries and radioactive particle implantations.High-intensity focused ultrasound(HIFU)was subsequently administered,resulting in complete ablation of the sarcoma without any significant complications other than bone damage at the treated site.However,approximately four months later,the patient experienced a broken lesion at the original location.After further diagnostic workup,the patient underwent additional surgery and is currently stable with a good quality of life.CONCLUSION HIFU has shown positive outcomes in achieving local control of limb spindle cell sarcoma,making it an effective non-invasive treatment option.展开更多
High-intensity earthquakes can cause severe damage to bridges,buildings,and ground surfaces,as well as disrupt human activities.Such earthquakes can create long-distance,high-intensity surface movements that negativel...High-intensity earthquakes can cause severe damage to bridges,buildings,and ground surfaces,as well as disrupt human activities.Such earthquakes can create long-distance,high-intensity surface movements that negatively impact bridge structures.This article delves into the seismic reduction and isolation design strategies for bridges in high-intensity earthquake areas.It analyzes various seismic reduction and isolation technologies and provides case studies to help relevant units understand the design strategies of these technologies.The results of this article can be used as a guideline to effectively enhance the seismic performance of bridges in high-intensity earthquake areas.展开更多
In order to clarify the danger of water breakout in the bottom plate of extra-thick coal seam mining, 2202 working face of a mine in the west is taken as the research object, and it is proposed to use the on-site moni...In order to clarify the danger of water breakout in the bottom plate of extra-thick coal seam mining, 2202 working face of a mine in the west is taken as the research object, and it is proposed to use the on-site monitoring means combining borehole peeping and microseismic monitoring, combined with the theoretical analysis to analyze the danger of water breakout in the bottom plate. The results show that: 1) the theoretically calculated maximum damage depth of the bottom plate is 27.5 m, and its layer is located above the Austrian ash aquifer, which has the danger of water breakout;2) the drill hole peeping at the bottom plate of the working face shows that the depth of the bottom plate fissure development reaches 26 m, and the integrity of the water barrier layer has been damaged, so there is the risk of water breakout;3) for the microseismic monitoring of the anomalous area, the bottom plate of the return air downstream channel occurs in the field with a one-week lag, which shows that microseismic monitoring events may reflect the water breakout of the underground. This shows that the microseismic monitoring events can reflect the changes of the underground flow field, which can provide a reference basis for the early warning of water breakout. The research results can provide reference for the prediction of sudden water hazard.展开更多
Background: High-intensity focused ultrasound (HIFU) has been introduced to improve skin laxity in recent years. However, very few studies have evaluated the safety and effectiveness of HIFU in Chinese populations. Me...Background: High-intensity focused ultrasound (HIFU) has been introduced to improve skin laxity in recent years. However, very few studies have evaluated the safety and effectiveness of HIFU in Chinese populations. Methods: In the study, 30 Chinese participants underwent HIFU (Bolida, Inc., Changsha, China) rejuvenation between February 1, 2022, and September 30, 2022. There were three different focal depths used depending on the area where shots were captured (4.5 mm, 4 MHz;3 mm, 7 MHz;1.5 mm, 7 MHz). After 3 months and 6 months of treatment, efficacy and safety were assessed by quantitative analysis. Results: Patients were satisfied with the clinical effects of HIFU rejuvenation after one session. In terms of effectiveness, HIFU was most successful in areas around the jawline, cheek, and perioral. In four cases, erythema was observed, in two cases, swollen gums were seen, but all of these effects were transient and mild. Conclusion: Bolida system can be safe and effective for facial tightening, additionally, they are most effective for jawline, cheek, and perioral improvements. In clinical practice, the Bolida system can be recommended as a reliable treatment option. .展开更多
Microstructural evolution and mechanical properties of in situ TiB2/A1 composites fabricated with exothermic reaction process under high-intensity ultra- sound produced by the magnetostrictive transducer were investig...Microstructural evolution and mechanical properties of in situ TiB2/A1 composites fabricated with exothermic reaction process under high-intensity ultra- sound produced by the magnetostrictive transducer were investigated. In this method, the microstructure and grain refining performance of the TiB2/A1 composites were characterized by optical morphology (OM), scanning electron microscopy (SEM), energy-dispersive spec- trometer (EDS), and X-ray diffraction (XRD) analysis. Microstructural observations show a decreasing trend in the grain size of the composites due to the ultrasound and the content of TiB2 particles in the composites. Compared with the process without ultrasound, the morphology and ag- glomeration of TiB2 particles are improved by high-in- tensity ultrasound. Meanwhile, it is proposed that the formation of TiBz particles occurs via the transformation from TiA13, and at the optimal amount of the reactants, the conversion efficiency of TiA13 into TiB2 almost reaches up to 100 %. Finally, the effects of high-intensity ultrasound and TiB2 particles on the mechanical properties of the TiB2/A1 composites were also discussed.展开更多
AIM:To investigate whether tumor debris created by high-intensity focused ultrasound(HIFU)could trigger antitumor immunity in a mouse hepatocellular carcinoma model. METHODS:Twenty C57BL/6J mice bearing H22 hepatocell...AIM:To investigate whether tumor debris created by high-intensity focused ultrasound(HIFU)could trigger antitumor immunity in a mouse hepatocellular carcinoma model. METHODS:Twenty C57BL/6J mice bearing H22 hepatocellular carcinoma were used to generate antitumor vaccines.Ten mice underwent HIFU ablation,and the remaining 10 mice received a sham-HIFU procedure with no ultrasound irradiation.Sixty normal mice were randomly divided into HIFU vaccine,tumor vaccine and control groups.These mice were immunized with HIFU-generated vaccine,tumor-generated vaccine,and saline,respectively.In addition,20 mice bearing H22 tumors were successfully treated with HIFU ablation. The protective immunity of the vaccinated mice was investigated before and after a subsequent H22 tumor challenge.Using the 3-(4,5-dimethylthiazol-2-yl)-2,5- diphenyltetrazolium bromide assay,the cytotoxicity of splenic lymphocytes co-cultured with H22 cells wasdetermined in vitro before the tumor challenge,and tumor volume and survival were measured in vivo after the challenge in each group.The mechanism was also explored by loading the vaccines with bone marrowderived dendritic cells(DCs). RESULTS:Compared to the control,HIFU therapy, tumor-generated and HIFU-generated vaccines significantly increased cytolytic activity against H22 cells in the splenocytes of the vaccinated mice(P<0.001). The tumor volume was significantly smaller in the HIFU vaccine group than in the tumor vaccine group(P <0.05)and control group(P<0.01).However,there was no tumor growth after H22 rechallenge in the HIFU therapy group.Forty-eight-day survival rate was 100%in mice in the HIFU therapy group,30%in both the HIFU vaccine and tumor vaccine groups,and 20% in the control group,indicating that the HIFU-treated mice displayed significantly longer survival than the vaccinated mice in the remaining three groups(P< 0.001).After bone marrow-derived DCs were incubated with HIFU-generated and tumor-generated vaccines, the number of mature DCs expressing MHC-Ⅱ + ,CD80 + and CD86 + molecules was significantly increased,and interleukin-12 and interferon-γlevels were significantly higher in the supernatants when compared with immature DCs incubated with mouse serum(P<0.001). However,no differences of the number of mature DCs and cytokine levels were observed between the HIFU- generated and tumor-generated vaccines(P>0.05). CONCLUSION:Tumor debris remaining after HIFU can improve tumor immunogenicity.This debris releases tumor antigens as an effective vaccine to develop host antitumor immune response after HIFU ablation.展开更多
AIM:To evaluate the safety and clinical application of high-intensity focused ultrasound(HIFU)therapy for unresectable pancreatic cancer(PC).METHODS:Thirty PC patients(16 cases in stage III and 14 cases in stage IV)wi...AIM:To evaluate the safety and clinical application of high-intensity focused ultrasound(HIFU)therapy for unresectable pancreatic cancer(PC).METHODS:Thirty PC patients(16 cases in stage III and 14 cases in stage IV)with visualized pancreatic tumors were admitted for HIFU therapy as an optional local therapy in addition to systemic chemotherapy or chemoradiotherapy.Informed consent was obtained.This study began at the end of 2008 and was approved by the ethics committee of our hospital[Institutional Review Board(IRB):890].The HIFU device used was the FEP-BY02(Yuande Bio-Medical Engineering,Beijing,China).RESULTS:The mean tumor size after HIFU therapy changed to 30.9±1.7 mm from 31.7±1.7 mm at pre-therapy.There were no significant changes in tumor size,mean number of treatment sessions(2.7±0.1 mm),or mean total treatment time(2.4±0.1 h).The rate of symptom relief effect was 66.7%.The effectiveness of primary lesion treatment was as follows:complete response,0;partial response,4;stable disease,22;progressive disease,4.Treatment after HIFU therapy included 2 operations,24 chemotherapy treatments,and 4 best supportive care treatments.Adverse events occurred in 10%of cases,namely pseudocyst formation in 2 cases and mild pancreatitis development in 1.However,no severe adverse events occurred in this study.CONCLUSION:We suggest that HIFU therapy is safe and has the potential to be a new method of combination therapy for PC.展开更多
BACKGROUND: High-intensity focused ultrasound (HIFU) is a non-invasive method of solid tissue ablation therapy. However, only a few studies have reported the effect of HIFU for unresectable pancreatic cancer. This stu...BACKGROUND: High-intensity focused ultrasound (HIFU) is a non-invasive method of solid tissue ablation therapy. However, only a few studies have reported the effect of HIFU for unresectable pancreatic cancer. This study aimed to evaluate the clinical benefits, survival time and complications associated with the use of HIFU ablation in patients with unresectable pancreatic cancer. METHODS: Twenty-five patients with unresectable pancreatic cancer were enrolled in our study. All patients received HIFU therapy for tumors at least once. The therapeutic effects of HIFU was evaluated in terms of Karnofsky performance status (KPS) scores, pain relief, serum CA19-9, and imaging by B-US and CT before and after the therapy. We also recorded median overall survival time and complications caused by the treatment. RESULTS: In the 25 patients, KPS scores were above 60, and increased KPS was observed in 23 patients after treatment. Pain relief occurred in 23 patients. Serum CA19-9 levels were significantly reduced one month after HIFU treatment and became negative in 5 patients. B-US revealed enhanced tumor echogenicity in 13 patients and decreased tumor blood supply in 9. Tumor necrosis was confirmed by CT in 8 patients one month after HIFU treatment. The median overall survival time was 10 months, and the 1-year survival rate was 42%. No severe complications were observed after HIFU treatment. CONCLUSION: HIFU can effectively relieve pain, increase KPS, decrease tumor growth and prolong the survival time of patients with unresectable pancreatic cancer.展开更多
A simulation code,GOAT,is developed to simulate single-bunch intensity-dependent effects and their interplay in the proton ring of the Electron-Ion Collider in China(EicC)project.GOAT is a scalable and portable macrop...A simulation code,GOAT,is developed to simulate single-bunch intensity-dependent effects and their interplay in the proton ring of the Electron-Ion Collider in China(EicC)project.GOAT is a scalable and portable macroparticle tracking code written in Python and coded by object-oriented programming technology.It allows for transverse and longitudinal tracking,including impedance,space charge effect,electron cloud effect,and beam-beam interaction.In this paper,physical models and numerical approaches for the four types of high-intensity effects,together with the benchmark results obtained through other simulation codes or theories,are presented and discussed.In addition,a numerical application of the cross-talk simulation between the beam-beam interaction and transverse impedance is shown,and a dipole instability is observed below the respective instability threshold.Different mitigation measures implemented in the code are used to suppress the instability.The flexibility,completeness,and advancement demonstrate that GOAT is a powerful tool for beam dynamics studies in the EicC project or other high-intensity accelerators.展开更多
AIM:To analyze whether high-intensity focused ultrasound(HIFU) ablation is an effective bridging therapy for patients with hepatocellular carcinoma(HCC).METHODS:From January 2007 to December 2010,49 consecutive HCC pa...AIM:To analyze whether high-intensity focused ultrasound(HIFU) ablation is an effective bridging therapy for patients with hepatocellular carcinoma(HCC).METHODS:From January 2007 to December 2010,49 consecutive HCC patients were listed for liver transplantation(UCSF criteria).The median waiting time for transplantation was 9.5 mo.Twenty-nine patients received transarterial chemoembolization(TACE) as a bringing therapy and 16 patients received no treatment before transplantation.Five patients received HIFU ablation as a bridging therapy.Another five patients with the same tumor staging(within the UCSF criteria) who received HIFU ablation but not on the transplant list were included for comparison.Patients were comparable in terms of Child-Pugh and model for end-stage liver disease scores,tumor size and number,and cause of cirrhosis.RESULTS:The HIFU group and TACE group showed no difference in terms of tumor size and tumor number.One patient in the HIFU group and no patient in the TACE group had gross ascites.The median hospital stay was 1 d(range,1-21 d) in the TACE group and two days(range,1-9 d) in the HIFU group(P < 0.000).No HIFU-related complication occurred.In the HIFU group,nine patients(90%) had complete response and one patient(10%) had partial response to the treatment.In the TACE group,only one patient(3%) had response to the treatment while 14 patients(48%) had stable disease and 14 patients(48%) had progressive disease(P = 0.00).Seven patients in the TACE group and no patient in the HIFU group dropped out from the transplant waiting list(P = 0.559).CONCLUSION:HIFU ablation is safe and effective in the treatment of HCC for patients with advanced cirrhosis.It may reduce the drop-out rate of liver transplant candidate.展开更多
The purpose of this study was to evaluate the outcome of patients with unresectable hepatocellular carcinoma(HCC) treated by sequential therapy of transcatheter arterial chemoembolization(TACE),three-dimensional c...The purpose of this study was to evaluate the outcome of patients with unresectable hepatocellular carcinoma(HCC) treated by sequential therapy of transcatheter arterial chemoembolization(TACE),three-dimensional conformal radiotherapy(3-DCRT) and high-intensity focused ultrasound(HIFU).From October,2005 to September,2010,120 patients with unresectable HCC received the sequential treatments of several courses of TACE followed in 2-4 weeks by 3-DCRT and then a single session of HIFU with a curative intent.The median tumor irradiation dose was 40 Gy.Tumor response,toxicity and overall survival rate were analyzed.Clinicopathologic factors affecting the primary technique effectiveness and overall survival rates were investigated by univariate analysis or multivariate analysis.All 120 HCC patients were followed up by the last follow-up time.Among these patients,hepatic toxicities due to treatment were notable in 9 cases.Gastrointestinal bleeding after the overall treatment occurred in 2 cases,leukopenia of grade III was detected in 1 case,radiation-induced liver disease(RILD) was observed in 2 patients,and first-and second-degree skin burn around the HIFU treatment zone were observed in 2 patients and 1 patient,respectively.Among 120 patients,23,83 and 14 cases achieved partial response,stable disease and progressive disease,respectively.The overall survival rates at 1 year,3 years and 5 years were 70%,35% and 15%,respectively,with a median survival time of 26 months.Both Child-Pugh liver function grading and radiation dose were determined to be independent predictors for overall survival revealed by the multivariate analysis.It is concluded that the sequential therapy of TACE,3-DCRT and HIFU is a promising therapeutic regimen for unresectable HCC.展开更多
OBJECTIVE To observe the efficacy of high-intensity focused ultrasound (HIFU) in the treatment of late-stage pancreatic cancer. METHODS Sixteen patients with advanced pancreatic cancer received HIFU therapy.Evaluation...OBJECTIVE To observe the efficacy of high-intensity focused ultrasound (HIFU) in the treatment of late-stage pancreatic cancer. METHODS Sixteen patients with advanced pancreatic cancer received HIFU therapy.Evaluation of efficacy was made on the basis of changes in clinical symptoms and variations in the tumor echo and size. RESULTS Clinical symptoms such as pain were significantly alleviated,echo of the tumor was enhanced with B-US and the quality of life such as eating,sleeping and mental status was markedly improved;no serious complications were observed. CONCLUSION The use of HIFU in the treatment of advanced pancreatic cancer is feasible and safe.It is effective in killing the carcinoma cells and alleviating pain.This technique may offer non-invasive therapy for the treatment of patients with late-stage pancreatic cancer.展开更多
The aim of this study was to investigate the feasibility and safety of high-intensity focused ultrasound (HIFU) combined with (+) low-dose external beam radiotherapy (LRT) as supplemental therapy for advanced p...The aim of this study was to investigate the feasibility and safety of high-intensity focused ultrasound (HIFU) combined with (+) low-dose external beam radiotherapy (LRT) as supplemental therapy for advanced prostate cancer (PCa) following hormonal therapy (HT). Our definition of HIFU+LRT refers to treating primary tumour lesions with HIFU in place of reduced field boost irradiation to the prostate, while retaining four-field box irradiation to the pelvis in conventional-dose external beam radiotherapy (CRT). We performed a prospective, controlled and non-randomized study on 120 patients with advanced PCa after HT who received HIFU, CRT, HIFU+LRT and HT alone, respectively. CT/MR imaging showed the primary tumours and pelvic lymph node metastases visibly shrank or even disappeared after HIFU +LRT treatment. There were significant differences among four groups with regard to overall survival (OS) and disease-specific survival (DSS) curves (P=0.018 and 0.015). Further comparison between each pair of groups suggested that the long-term DSS of the H IFU + LRT group was higher than those of the other three groups, but there was no significant difference between the HIFU+LRT group and the CRT group. Multivariable Cox's proportional hazard model showed that both HIFU+LRT and CRT were independently associated with DSS (P=0.001 and 0.035) and had protective effects with regard to the risk of death. Compared with CRT, HIFU +LRT significantly decreased incidences of radiation-related late gastrointestinal (GI) and genitourinary (GU) toxicity grade ≥ II. In conclusion, long-term survival of patients with advanced PCa benefited from strengthening local control of primary tumour and reRional lymph node metastases after HT. As an alternative to CRT, HIFU+LRT showed Rood efficacy and better safety.展开更多
The scarcity of liver grafts in Asia leads to a significant dropout of patients from liver transplant waiting lists, particularly patients with hepatocellular carcinoma and a low model for end-stage liver disease scor...The scarcity of liver grafts in Asia leads to a significant dropout of patients from liver transplant waiting lists, particularly patients with hepatocellular carcinoma and a low model for end-stage liver disease score. In order to reduce dropping out, different bridging therapies are employed. We report the use of high-intensity focused ultrasound ablation as a bridging therapy for a patient with hepatocellular carcinoma of stage two and an extremely low platelet count (20×10 9 /L). The ablation was successful. Blood tests showed that his liver function was similar before and after the treatment. No adhesion was encountered in the liver transplantation performed six months later.展开更多
To investigate the safety, feasibility and effectiveness of transrectal high-intensity focused ultrasound (HIFU) in the ablation of canine prostate, 20 dogs were divided randomly into 5 groups. Sixteen canine prosta...To investigate the safety, feasibility and effectiveness of transrectal high-intensity focused ultrasound (HIFU) in the ablation of canine prostate, 20 dogs were divided randomly into 5 groups. Sixteen canine prostates were treated with the third-generation transrectal HIFU device (Sonablate-500^TM). Transrectal ultrasound images of the prostate and prostatic urethra were observed preoperatively and postoperatively. Serial study was performed 30 min, 30 days, 60 days and 180 days after the therapy. The rectum, periprostatic tissues, and prostate were excised en bloc and the tissues were fixed for gross and histological analysis. Our results showed that the average maximal diameter of prostatic urethra was 0.59-0.11 cm before the operation and 2.57±0.98 cm 60 days after the operation. The volume of prostate was 6.5±3.12 cm^3 before the treatment while the volume was 4.13±0.23 cm^3 60 days after the treatment and the differences were statistically significant (P〈0.05). Histologically, there was a clear demarcation between the necrotic area of the treated tissues and the unaffected surrounding tissues. All the necrotic tissues in the targeted zone broke off and the prostatic urethra became cavitary 60 days later. The more frequent complications were urinary retention and frequency and hematuria. No rectal injury occurred during the treatment. It is concluded that the third-generation transrectal HIFU is capable of destroying prostatic tissue, substantially increasing the width of the prostatic urethra without causing injury to the adjacent tissues. The risk of postoperative complications associated with HIFU was low. HIFU may become a safe, effective and minimally invasive alternative for the treatment of prostatic diseases.展开更多
Recently, the phase compensation technique has allowed the ultrasound to propagate through the skull and focus into the brain. However, the temperature evolution during treatment is hard to control to achieve effectiv...Recently, the phase compensation technique has allowed the ultrasound to propagate through the skull and focus into the brain. However, the temperature evolution during treatment is hard to control to achieve effective treatment and avoid over-high temperature. Proposed in this paper is a method to modulate the temperature distribution in the focal region. It superimposes two signals which focus on two preset different targets with a certain distance. Then the temperature distribution is modulated by changing triggering time delay and amplitudes of the two signals. The simulation model is established based on an 82-element transducer and computed tomography (CT) data of a volunteer's head. A finite- difference time-domain (FDTD) method is used to calculate the temperature distributions. The results show that when the distances between the two targets respectively are 7.5-12.5 mm on the acoustic axis and 2.0-3.0 mm in the direction perpendicular to the acoustic axis, a focal region with a uniform temperature distribution (64-65 ℃) can be created. Moreover, the volume of the focal region formed by one irradiation can be adjusted (26.8-266.7 mm3) along with the uniform temperature distribution. This method may ensure the safety and efficacy of HIFU brain tumor therapy.展开更多
Objective The objective of this study was to explore the short-term effects and postoperative complications of ultrasound-guided percutaneous ethanol-lipiodol injection(PEI)combined with high-intensity focused ultraso...Objective The objective of this study was to explore the short-term effects and postoperative complications of ultrasound-guided percutaneous ethanol-lipiodol injection(PEI)combined with high-intensity focused ultrasound(HIFU)for the treatment of small hepatocellular carcinoma in a special or high-risk location.Methods Forty patients with small liver cancer in a special or high-risk location were randomly divided into two groups:20 patients were treated with PEI combined with HIFU(P+H group),and 20 patients were treated with HIFU alone(H group).There were no significant differences in average age,liver function,tumor location,tumor number,or tumor size between the two groups(P>0.05).Results Significant differences were observed in ablation parameters between the two groups(P<0.05).Under the same power,ablation rates of the P+H group were significantly higher than those in the H group,and postoperative complications in the P+H group were significantly lower than those in the H group(P<0.05).Conclusion The combination of PEI and HIFU has better clinical value than HIFU alone for small-cell liver cancer in special or high-risk locations.展开更多
Hyperthermia effects (39-44 ℃) induced by pulsed high-intensity focused ultrasound (HIFU) have been regarded as a promising therapeutic tool for boosting immune responses or enhancing drug delivery into a solid t...Hyperthermia effects (39-44 ℃) induced by pulsed high-intensity focused ultrasound (HIFU) have been regarded as a promising therapeutic tool for boosting immune responses or enhancing drug delivery into a solid tumor. However, previous studies also reported that the cell death occurs when cells are maintained at 43 ℃ for more than 20 minutes. The aim of this study is to investigate thermal responses inside in vivo rabbit auricular veins exposed to pulsed HIFU (1.17 MHz, 5300 W/cm2, with relatively low-duty ratios (0.2%-4.3%). The results show that: (1) with constant pulse repetition frequency (PRF) (e.g., 1 Hz), the thermal responses inside the vessel will increase with the increasing duty ratio; (2) a temperature elevation to 43 ℃ can be identified at the duty ratio of 4.3%; (3) with constant duty ratios, the change of PRF will not significantly affect the temperature measurement in the vessel; (4) as the duty ratios lower than 4.3%, the presence of microbubbles will not significantly enhance the thermal responses in the vessel, but will facilitate HIFU-induced inertial cavitation events.展开更多
BACKGROUND High-intensity focused ultrasound(HIFU) ablation is a minimally invasive approach in gynecology that is used to manage uterine fibroids.Although this procedure is safe and effective,adverse outcomes are bec...BACKGROUND High-intensity focused ultrasound(HIFU) ablation is a minimally invasive approach in gynecology that is used to manage uterine fibroids.Although this procedure is safe and effective,adverse outcomes are becoming a major problem.CASE SUMMARY We present a case of ventral hernia that occurred as a rare and delayed complication of HIFU ablation for uterine fibroids treatment.The patient came to the hospital with abdominal bloating that occurred 6 mo after ultrasound-guided HIFU ablation for managing uterine fibroids.The ventral hernia,which occurred due to atrophied muscle layers following the procedure,was confirmed by imaging studies and intraoperative findings.She required a hernia repair with mesh and hysterectomy for definitive treatment of uterine fibroid.CONCLUSION High-intensity ultrasound ablation should be performed only on appropriate candidates.Patients should be educated about potential complications of the procedure and the possibility of subsequent treatment.Post-procedural long-term follow-up for detecting delayed adverse effects is important.展开更多
To evaluate the safety and efficacy of transrectal high-intensity focused ultrasound (HIFU) in the treatment of benign prostatic hyperplasia (BPH), serial studies were conducted in 150 BPH patients before and 30 m...To evaluate the safety and efficacy of transrectal high-intensity focused ultrasound (HIFU) in the treatment of benign prostatic hyperplasia (BPH), serial studies were conducted in 150 BPH patients before and 30 min, 1, 2, 6 and 12 month(s) after Sonablate-500TM HIFU treatment. A silicon-coated indwelling 16F latex catheter was placed during the determination of the therapy zone. Preoperative and postoperative evaluations were made by using the international prostate symptom score (IPSS), quality of life (QOL), uroflowmetric findings and transrectal ultrasound, and incidence of complications. The cystourethrography was done in 23 patients within 1 year postoperatively. The results showed that after HIFU treatment, IPSS and QOL scores were significantly decreased at 1, 2, 6 and 12 month(s) (P〈0.01). Maximum urine flow rate (6.0 to 17.2 mL/s, P〈0.01), PVR (75.0 to 30.3, P〈0.01) and prostatic volume (65.0 to 38.1 mL, P〈0.05) were significantly improved 12 months after the operation. Recurrent urinary retention (17=2) and urethrorectal fistula (n=1) occurred at the 15th postoperative day. The duration of the HIFU prostate ablation was 25-90 min. The mean time for an indwelling catheter was 3-19 days. These data demonstrate that treatment of BPH with Sonab- late-500TM HIFU is safe and effective.展开更多
文摘BACKGROUND Undifferentiated pleomorphic sarcomas,also known as spindle cell sarcomas,are a relatively uncommon subtype of soft tissue sarcomas in clinical practice.CASE SUMMARY We present a case report of a 69-year-old female patient who was diagnosed with undifferentiated spindle cell soft tissue sarcoma on her left thigh.Surgical excision was initially performed,but the patient experienced a local recurrence following multiple surgeries and radioactive particle implantations.High-intensity focused ultrasound(HIFU)was subsequently administered,resulting in complete ablation of the sarcoma without any significant complications other than bone damage at the treated site.However,approximately four months later,the patient experienced a broken lesion at the original location.After further diagnostic workup,the patient underwent additional surgery and is currently stable with a good quality of life.CONCLUSION HIFU has shown positive outcomes in achieving local control of limb spindle cell sarcoma,making it an effective non-invasive treatment option.
文摘High-intensity earthquakes can cause severe damage to bridges,buildings,and ground surfaces,as well as disrupt human activities.Such earthquakes can create long-distance,high-intensity surface movements that negatively impact bridge structures.This article delves into the seismic reduction and isolation design strategies for bridges in high-intensity earthquake areas.It analyzes various seismic reduction and isolation technologies and provides case studies to help relevant units understand the design strategies of these technologies.The results of this article can be used as a guideline to effectively enhance the seismic performance of bridges in high-intensity earthquake areas.
文摘In order to clarify the danger of water breakout in the bottom plate of extra-thick coal seam mining, 2202 working face of a mine in the west is taken as the research object, and it is proposed to use the on-site monitoring means combining borehole peeping and microseismic monitoring, combined with the theoretical analysis to analyze the danger of water breakout in the bottom plate. The results show that: 1) the theoretically calculated maximum damage depth of the bottom plate is 27.5 m, and its layer is located above the Austrian ash aquifer, which has the danger of water breakout;2) the drill hole peeping at the bottom plate of the working face shows that the depth of the bottom plate fissure development reaches 26 m, and the integrity of the water barrier layer has been damaged, so there is the risk of water breakout;3) for the microseismic monitoring of the anomalous area, the bottom plate of the return air downstream channel occurs in the field with a one-week lag, which shows that microseismic monitoring events may reflect the water breakout of the underground. This shows that the microseismic monitoring events can reflect the changes of the underground flow field, which can provide a reference basis for the early warning of water breakout. The research results can provide reference for the prediction of sudden water hazard.
文摘Background: High-intensity focused ultrasound (HIFU) has been introduced to improve skin laxity in recent years. However, very few studies have evaluated the safety and effectiveness of HIFU in Chinese populations. Methods: In the study, 30 Chinese participants underwent HIFU (Bolida, Inc., Changsha, China) rejuvenation between February 1, 2022, and September 30, 2022. There were three different focal depths used depending on the area where shots were captured (4.5 mm, 4 MHz;3 mm, 7 MHz;1.5 mm, 7 MHz). After 3 months and 6 months of treatment, efficacy and safety were assessed by quantitative analysis. Results: Patients were satisfied with the clinical effects of HIFU rejuvenation after one session. In terms of effectiveness, HIFU was most successful in areas around the jawline, cheek, and perioral. In four cases, erythema was observed, in two cases, swollen gums were seen, but all of these effects were transient and mild. Conclusion: Bolida system can be safe and effective for facial tightening, additionally, they are most effective for jawline, cheek, and perioral improvements. In clinical practice, the Bolida system can be recommended as a reliable treatment option. .
基金financially supported by the National High Technology Research and Development Program of China(No.2013AA031104)
文摘Microstructural evolution and mechanical properties of in situ TiB2/A1 composites fabricated with exothermic reaction process under high-intensity ultra- sound produced by the magnetostrictive transducer were investigated. In this method, the microstructure and grain refining performance of the TiB2/A1 composites were characterized by optical morphology (OM), scanning electron microscopy (SEM), energy-dispersive spec- trometer (EDS), and X-ray diffraction (XRD) analysis. Microstructural observations show a decreasing trend in the grain size of the composites due to the ultrasound and the content of TiB2 particles in the composites. Compared with the process without ultrasound, the morphology and ag- glomeration of TiB2 particles are improved by high-in- tensity ultrasound. Meanwhile, it is proposed that the formation of TiBz particles occurs via the transformation from TiA13, and at the optimal amount of the reactants, the conversion efficiency of TiA13 into TiB2 almost reaches up to 100 %. Finally, the effects of high-intensity ultrasound and TiB2 particles on the mechanical properties of the TiB2/A1 composites were also discussed.
基金Supported by The Foundation of Ministry of Education of China,No.IRT0454
文摘AIM:To investigate whether tumor debris created by high-intensity focused ultrasound(HIFU)could trigger antitumor immunity in a mouse hepatocellular carcinoma model. METHODS:Twenty C57BL/6J mice bearing H22 hepatocellular carcinoma were used to generate antitumor vaccines.Ten mice underwent HIFU ablation,and the remaining 10 mice received a sham-HIFU procedure with no ultrasound irradiation.Sixty normal mice were randomly divided into HIFU vaccine,tumor vaccine and control groups.These mice were immunized with HIFU-generated vaccine,tumor-generated vaccine,and saline,respectively.In addition,20 mice bearing H22 tumors were successfully treated with HIFU ablation. The protective immunity of the vaccinated mice was investigated before and after a subsequent H22 tumor challenge.Using the 3-(4,5-dimethylthiazol-2-yl)-2,5- diphenyltetrazolium bromide assay,the cytotoxicity of splenic lymphocytes co-cultured with H22 cells wasdetermined in vitro before the tumor challenge,and tumor volume and survival were measured in vivo after the challenge in each group.The mechanism was also explored by loading the vaccines with bone marrowderived dendritic cells(DCs). RESULTS:Compared to the control,HIFU therapy, tumor-generated and HIFU-generated vaccines significantly increased cytolytic activity against H22 cells in the splenocytes of the vaccinated mice(P<0.001). The tumor volume was significantly smaller in the HIFU vaccine group than in the tumor vaccine group(P <0.05)and control group(P<0.01).However,there was no tumor growth after H22 rechallenge in the HIFU therapy group.Forty-eight-day survival rate was 100%in mice in the HIFU therapy group,30%in both the HIFU vaccine and tumor vaccine groups,and 20% in the control group,indicating that the HIFU-treated mice displayed significantly longer survival than the vaccinated mice in the remaining three groups(P< 0.001).After bone marrow-derived DCs were incubated with HIFU-generated and tumor-generated vaccines, the number of mature DCs expressing MHC-Ⅱ + ,CD80 + and CD86 + molecules was significantly increased,and interleukin-12 and interferon-γlevels were significantly higher in the supernatants when compared with immature DCs incubated with mouse serum(P<0.001). However,no differences of the number of mature DCs and cytokine levels were observed between the HIFU- generated and tumor-generated vaccines(P>0.05). CONCLUSION:Tumor debris remaining after HIFU can improve tumor immunogenicity.This debris releases tumor antigens as an effective vaccine to develop host antitumor immune response after HIFU ablation.
基金Supported by The cancer research project group of Tokyo Medical University
文摘AIM:To evaluate the safety and clinical application of high-intensity focused ultrasound(HIFU)therapy for unresectable pancreatic cancer(PC).METHODS:Thirty PC patients(16 cases in stage III and 14 cases in stage IV)with visualized pancreatic tumors were admitted for HIFU therapy as an optional local therapy in addition to systemic chemotherapy or chemoradiotherapy.Informed consent was obtained.This study began at the end of 2008 and was approved by the ethics committee of our hospital[Institutional Review Board(IRB):890].The HIFU device used was the FEP-BY02(Yuande Bio-Medical Engineering,Beijing,China).RESULTS:The mean tumor size after HIFU therapy changed to 30.9±1.7 mm from 31.7±1.7 mm at pre-therapy.There were no significant changes in tumor size,mean number of treatment sessions(2.7±0.1 mm),or mean total treatment time(2.4±0.1 h).The rate of symptom relief effect was 66.7%.The effectiveness of primary lesion treatment was as follows:complete response,0;partial response,4;stable disease,22;progressive disease,4.Treatment after HIFU therapy included 2 operations,24 chemotherapy treatments,and 4 best supportive care treatments.Adverse events occurred in 10%of cases,namely pseudocyst formation in 2 cases and mild pancreatitis development in 1.However,no severe adverse events occurred in this study.CONCLUSION:We suggest that HIFU therapy is safe and has the potential to be a new method of combination therapy for PC.
基金supported by grants from the Ministry of Health Research Foundation(WKJ2006-1-007)the Hunan Provincial National Science Foundation (11JJ5060)
文摘BACKGROUND: High-intensity focused ultrasound (HIFU) is a non-invasive method of solid tissue ablation therapy. However, only a few studies have reported the effect of HIFU for unresectable pancreatic cancer. This study aimed to evaluate the clinical benefits, survival time and complications associated with the use of HIFU ablation in patients with unresectable pancreatic cancer. METHODS: Twenty-five patients with unresectable pancreatic cancer were enrolled in our study. All patients received HIFU therapy for tumors at least once. The therapeutic effects of HIFU was evaluated in terms of Karnofsky performance status (KPS) scores, pain relief, serum CA19-9, and imaging by B-US and CT before and after the therapy. We also recorded median overall survival time and complications caused by the treatment. RESULTS: In the 25 patients, KPS scores were above 60, and increased KPS was observed in 23 patients after treatment. Pain relief occurred in 23 patients. Serum CA19-9 levels were significantly reduced one month after HIFU treatment and became negative in 5 patients. B-US revealed enhanced tumor echogenicity in 13 patients and decreased tumor blood supply in 9. Tumor necrosis was confirmed by CT in 8 patients one month after HIFU treatment. The median overall survival time was 10 months, and the 1-year survival rate was 42%. No severe complications were observed after HIFU treatment. CONCLUSION: HIFU can effectively relieve pain, increase KPS, decrease tumor growth and prolong the survival time of patients with unresectable pancreatic cancer.
基金supported by the National Science Fund for Distinguished Young Scholars (No.11825505)the National Key R&D Program of China (No.2019YFA0405400)。
文摘A simulation code,GOAT,is developed to simulate single-bunch intensity-dependent effects and their interplay in the proton ring of the Electron-Ion Collider in China(EicC)project.GOAT is a scalable and portable macroparticle tracking code written in Python and coded by object-oriented programming technology.It allows for transverse and longitudinal tracking,including impedance,space charge effect,electron cloud effect,and beam-beam interaction.In this paper,physical models and numerical approaches for the four types of high-intensity effects,together with the benchmark results obtained through other simulation codes or theories,are presented and discussed.In addition,a numerical application of the cross-talk simulation between the beam-beam interaction and transverse impedance is shown,and a dipole instability is observed below the respective instability threshold.Different mitigation measures implemented in the code are used to suppress the instability.The flexibility,completeness,and advancement demonstrate that GOAT is a powerful tool for beam dynamics studies in the EicC project or other high-intensity accelerators.
文摘AIM:To analyze whether high-intensity focused ultrasound(HIFU) ablation is an effective bridging therapy for patients with hepatocellular carcinoma(HCC).METHODS:From January 2007 to December 2010,49 consecutive HCC patients were listed for liver transplantation(UCSF criteria).The median waiting time for transplantation was 9.5 mo.Twenty-nine patients received transarterial chemoembolization(TACE) as a bringing therapy and 16 patients received no treatment before transplantation.Five patients received HIFU ablation as a bridging therapy.Another five patients with the same tumor staging(within the UCSF criteria) who received HIFU ablation but not on the transplant list were included for comparison.Patients were comparable in terms of Child-Pugh and model for end-stage liver disease scores,tumor size and number,and cause of cirrhosis.RESULTS:The HIFU group and TACE group showed no difference in terms of tumor size and tumor number.One patient in the HIFU group and no patient in the TACE group had gross ascites.The median hospital stay was 1 d(range,1-21 d) in the TACE group and two days(range,1-9 d) in the HIFU group(P < 0.000).No HIFU-related complication occurred.In the HIFU group,nine patients(90%) had complete response and one patient(10%) had partial response to the treatment.In the TACE group,only one patient(3%) had response to the treatment while 14 patients(48%) had stable disease and 14 patients(48%) had progressive disease(P = 0.00).Seven patients in the TACE group and no patient in the HIFU group dropped out from the transplant waiting list(P = 0.559).CONCLUSION:HIFU ablation is safe and effective in the treatment of HCC for patients with advanced cirrhosis.It may reduce the drop-out rate of liver transplant candidate.
文摘The purpose of this study was to evaluate the outcome of patients with unresectable hepatocellular carcinoma(HCC) treated by sequential therapy of transcatheter arterial chemoembolization(TACE),three-dimensional conformal radiotherapy(3-DCRT) and high-intensity focused ultrasound(HIFU).From October,2005 to September,2010,120 patients with unresectable HCC received the sequential treatments of several courses of TACE followed in 2-4 weeks by 3-DCRT and then a single session of HIFU with a curative intent.The median tumor irradiation dose was 40 Gy.Tumor response,toxicity and overall survival rate were analyzed.Clinicopathologic factors affecting the primary technique effectiveness and overall survival rates were investigated by univariate analysis or multivariate analysis.All 120 HCC patients were followed up by the last follow-up time.Among these patients,hepatic toxicities due to treatment were notable in 9 cases.Gastrointestinal bleeding after the overall treatment occurred in 2 cases,leukopenia of grade III was detected in 1 case,radiation-induced liver disease(RILD) was observed in 2 patients,and first-and second-degree skin burn around the HIFU treatment zone were observed in 2 patients and 1 patient,respectively.Among 120 patients,23,83 and 14 cases achieved partial response,stable disease and progressive disease,respectively.The overall survival rates at 1 year,3 years and 5 years were 70%,35% and 15%,respectively,with a median survival time of 26 months.Both Child-Pugh liver function grading and radiation dose were determined to be independent predictors for overall survival revealed by the multivariate analysis.It is concluded that the sequential therapy of TACE,3-DCRT and HIFU is a promising therapeutic regimen for unresectable HCC.
基金a grant from Medical Scientific Research Foundation of Guangdong Province,China (No.A2007481)
文摘OBJECTIVE To observe the efficacy of high-intensity focused ultrasound (HIFU) in the treatment of late-stage pancreatic cancer. METHODS Sixteen patients with advanced pancreatic cancer received HIFU therapy.Evaluation of efficacy was made on the basis of changes in clinical symptoms and variations in the tumor echo and size. RESULTS Clinical symptoms such as pain were significantly alleviated,echo of the tumor was enhanced with B-US and the quality of life such as eating,sleeping and mental status was markedly improved;no serious complications were observed. CONCLUSION The use of HIFU in the treatment of advanced pancreatic cancer is feasible and safe.It is effective in killing the carcinoma cells and alleviating pain.This technique may offer non-invasive therapy for the treatment of patients with late-stage pancreatic cancer.
文摘The aim of this study was to investigate the feasibility and safety of high-intensity focused ultrasound (HIFU) combined with (+) low-dose external beam radiotherapy (LRT) as supplemental therapy for advanced prostate cancer (PCa) following hormonal therapy (HT). Our definition of HIFU+LRT refers to treating primary tumour lesions with HIFU in place of reduced field boost irradiation to the prostate, while retaining four-field box irradiation to the pelvis in conventional-dose external beam radiotherapy (CRT). We performed a prospective, controlled and non-randomized study on 120 patients with advanced PCa after HT who received HIFU, CRT, HIFU+LRT and HT alone, respectively. CT/MR imaging showed the primary tumours and pelvic lymph node metastases visibly shrank or even disappeared after HIFU +LRT treatment. There were significant differences among four groups with regard to overall survival (OS) and disease-specific survival (DSS) curves (P=0.018 and 0.015). Further comparison between each pair of groups suggested that the long-term DSS of the H IFU + LRT group was higher than those of the other three groups, but there was no significant difference between the HIFU+LRT group and the CRT group. Multivariable Cox's proportional hazard model showed that both HIFU+LRT and CRT were independently associated with DSS (P=0.001 and 0.035) and had protective effects with regard to the risk of death. Compared with CRT, HIFU +LRT significantly decreased incidences of radiation-related late gastrointestinal (GI) and genitourinary (GU) toxicity grade ≥ II. In conclusion, long-term survival of patients with advanced PCa benefited from strengthening local control of primary tumour and reRional lymph node metastases after HT. As an alternative to CRT, HIFU+LRT showed Rood efficacy and better safety.
文摘The scarcity of liver grafts in Asia leads to a significant dropout of patients from liver transplant waiting lists, particularly patients with hepatocellular carcinoma and a low model for end-stage liver disease score. In order to reduce dropping out, different bridging therapies are employed. We report the use of high-intensity focused ultrasound ablation as a bridging therapy for a patient with hepatocellular carcinoma of stage two and an extremely low platelet count (20×10 9 /L). The ablation was successful. Blood tests showed that his liver function was similar before and after the treatment. No adhesion was encountered in the liver transplantation performed six months later.
基金This project was supported by grants from the foundation of Medical Research of Guangdong Province (No. A2004478)the Program of Science and Technology of Guangdong Province (No. 2004B30301013)
文摘To investigate the safety, feasibility and effectiveness of transrectal high-intensity focused ultrasound (HIFU) in the ablation of canine prostate, 20 dogs were divided randomly into 5 groups. Sixteen canine prostates were treated with the third-generation transrectal HIFU device (Sonablate-500^TM). Transrectal ultrasound images of the prostate and prostatic urethra were observed preoperatively and postoperatively. Serial study was performed 30 min, 30 days, 60 days and 180 days after the therapy. The rectum, periprostatic tissues, and prostate were excised en bloc and the tissues were fixed for gross and histological analysis. Our results showed that the average maximal diameter of prostatic urethra was 0.59-0.11 cm before the operation and 2.57±0.98 cm 60 days after the operation. The volume of prostate was 6.5±3.12 cm^3 before the treatment while the volume was 4.13±0.23 cm^3 60 days after the treatment and the differences were statistically significant (P〈0.05). Histologically, there was a clear demarcation between the necrotic area of the treated tissues and the unaffected surrounding tissues. All the necrotic tissues in the targeted zone broke off and the prostatic urethra became cavitary 60 days later. The more frequent complications were urinary retention and frequency and hematuria. No rectal injury occurred during the treatment. It is concluded that the third-generation transrectal HIFU is capable of destroying prostatic tissue, substantially increasing the width of the prostatic urethra without causing injury to the adjacent tissues. The risk of postoperative complications associated with HIFU was low. HIFU may become a safe, effective and minimally invasive alternative for the treatment of prostatic diseases.
基金Project supported by the National Natural Science Foundation of China(Grant No.81272495)the Natural Science Foundation of Tianjin,China(Grant No.16JC2DJC32200)
文摘Recently, the phase compensation technique has allowed the ultrasound to propagate through the skull and focus into the brain. However, the temperature evolution during treatment is hard to control to achieve effective treatment and avoid over-high temperature. Proposed in this paper is a method to modulate the temperature distribution in the focal region. It superimposes two signals which focus on two preset different targets with a certain distance. Then the temperature distribution is modulated by changing triggering time delay and amplitudes of the two signals. The simulation model is established based on an 82-element transducer and computed tomography (CT) data of a volunteer's head. A finite- difference time-domain (FDTD) method is used to calculate the temperature distributions. The results show that when the distances between the two targets respectively are 7.5-12.5 mm on the acoustic axis and 2.0-3.0 mm in the direction perpendicular to the acoustic axis, a focal region with a uniform temperature distribution (64-65 ℃) can be created. Moreover, the volume of the focal region formed by one irradiation can be adjusted (26.8-266.7 mm3) along with the uniform temperature distribution. This method may ensure the safety and efficacy of HIFU brain tumor therapy.
基金Supported by the research grant from Dalian Health and Family Planning Commission of China(No.1611020).
文摘Objective The objective of this study was to explore the short-term effects and postoperative complications of ultrasound-guided percutaneous ethanol-lipiodol injection(PEI)combined with high-intensity focused ultrasound(HIFU)for the treatment of small hepatocellular carcinoma in a special or high-risk location.Methods Forty patients with small liver cancer in a special or high-risk location were randomly divided into two groups:20 patients were treated with PEI combined with HIFU(P+H group),and 20 patients were treated with HIFU alone(H group).There were no significant differences in average age,liver function,tumor location,tumor number,or tumor size between the two groups(P>0.05).Results Significant differences were observed in ablation parameters between the two groups(P<0.05).Under the same power,ablation rates of the P+H group were significantly higher than those in the H group,and postoperative complications in the P+H group were significantly lower than those in the H group(P<0.05).Conclusion The combination of PEI and HIFU has better clinical value than HIFU alone for small-cell liver cancer in special or high-risk locations.
基金Project supported by the National Basic Research Program of China (Grant No. 2011CB707900)the National Natural Science Foundation of China (Grant Nos. 11074123, 10974095, 10904068, and 10204014)+2 种基金the Fundamental Research Funds for the Central Universities of China (Grant Nos. 111602040 and 1095020409)the Natural Science Foundation of Jiangsu Province of China (Grant No. BK2011812)the Priority Academic Program Development of Jiangsu Higher Educaton Institutions of China
文摘Hyperthermia effects (39-44 ℃) induced by pulsed high-intensity focused ultrasound (HIFU) have been regarded as a promising therapeutic tool for boosting immune responses or enhancing drug delivery into a solid tumor. However, previous studies also reported that the cell death occurs when cells are maintained at 43 ℃ for more than 20 minutes. The aim of this study is to investigate thermal responses inside in vivo rabbit auricular veins exposed to pulsed HIFU (1.17 MHz, 5300 W/cm2, with relatively low-duty ratios (0.2%-4.3%). The results show that: (1) with constant pulse repetition frequency (PRF) (e.g., 1 Hz), the thermal responses inside the vessel will increase with the increasing duty ratio; (2) a temperature elevation to 43 ℃ can be identified at the duty ratio of 4.3%; (3) with constant duty ratios, the change of PRF will not significantly affect the temperature measurement in the vessel; (4) as the duty ratios lower than 4.3%, the presence of microbubbles will not significantly enhance the thermal responses in the vessel, but will facilitate HIFU-induced inertial cavitation events.
文摘BACKGROUND High-intensity focused ultrasound(HIFU) ablation is a minimally invasive approach in gynecology that is used to manage uterine fibroids.Although this procedure is safe and effective,adverse outcomes are becoming a major problem.CASE SUMMARY We present a case of ventral hernia that occurred as a rare and delayed complication of HIFU ablation for uterine fibroids treatment.The patient came to the hospital with abdominal bloating that occurred 6 mo after ultrasound-guided HIFU ablation for managing uterine fibroids.The ventral hernia,which occurred due to atrophied muscle layers following the procedure,was confirmed by imaging studies and intraoperative findings.She required a hernia repair with mesh and hysterectomy for definitive treatment of uterine fibroid.CONCLUSION High-intensity ultrasound ablation should be performed only on appropriate candidates.Patients should be educated about potential complications of the procedure and the possibility of subsequent treatment.Post-procedural long-term follow-up for detecting delayed adverse effects is important.
基金the foundation of Medical Research of Guangdong Province (No. A2004478) the Program of Science and Technology of Guangdong Province (No. 2004B30301013).
文摘To evaluate the safety and efficacy of transrectal high-intensity focused ultrasound (HIFU) in the treatment of benign prostatic hyperplasia (BPH), serial studies were conducted in 150 BPH patients before and 30 min, 1, 2, 6 and 12 month(s) after Sonablate-500TM HIFU treatment. A silicon-coated indwelling 16F latex catheter was placed during the determination of the therapy zone. Preoperative and postoperative evaluations were made by using the international prostate symptom score (IPSS), quality of life (QOL), uroflowmetric findings and transrectal ultrasound, and incidence of complications. The cystourethrography was done in 23 patients within 1 year postoperatively. The results showed that after HIFU treatment, IPSS and QOL scores were significantly decreased at 1, 2, 6 and 12 month(s) (P〈0.01). Maximum urine flow rate (6.0 to 17.2 mL/s, P〈0.01), PVR (75.0 to 30.3, P〈0.01) and prostatic volume (65.0 to 38.1 mL, P〈0.05) were significantly improved 12 months after the operation. Recurrent urinary retention (17=2) and urethrorectal fistula (n=1) occurred at the 15th postoperative day. The duration of the HIFU prostate ablation was 25-90 min. The mean time for an indwelling catheter was 3-19 days. These data demonstrate that treatment of BPH with Sonab- late-500TM HIFU is safe and effective.