Traditionally, basis weight control valve is driven by a constant frequency pulse signal. Therefore, it is difficult for the valve to match the control precision of basis weight. Dynamic simulation research using Matl...Traditionally, basis weight control valve is driven by a constant frequency pulse signal. Therefore, it is difficult for the valve to match the control precision of basis weight. Dynamic simulation research using Matlab/Simulink indicates that there is much more overshoot and fluctuating during the valve-positioning process. In order to improve the valve-positioning precision, the control method of trapezoidal velocity curve was studied. The simulation result showed that the positioning steady-state error was less than 0.0056%, whereas the peak error was less than 0.016% by using trapezoidal velocity curve at 10 positioning steps. A valve-positioning precision experimental device for the stepper motor of basis weight control valve was developed. The experiment results showed that the error ratio of 1/10000 positioning steps was 4% by using trapezoidal velocity curve. Furthermore, the error ratio of 10/10000 positioning steps was 0.5%. It proved that the valve-positioning precision of trapezoidal velocity curve was much higher than that of the constant frequency pulse signal control strategy. The new control method of trapezoidal velocity curve can satisfy the precision requirement of 10000 steps.展开更多
The BeiDou-3 navigation satellite system(BDS-3)provides a full-domain high-precision positioning service for the power system to ensure safe and stable operation.However,BDS-3 power system positioning faces certain ch...The BeiDou-3 navigation satellite system(BDS-3)provides a full-domain high-precision positioning service for the power system to ensure safe and stable operation.However,BDS-3 power system positioning faces certain challenges,such as complex electromagnetic interference and incomplete error elimination.Herein,a back propagation neural network-improved least mean square(BP-LMS)adaptive filtering method is proposed for the BDS-3 full-domain and high-precision power system positioning,which utilizes the loss function to update the weight of the BP hidden layer,computes the pseudo compensation range,and eliminates the impact of electromagnetic interference to enhance the accuracy of power system positioning.Simulation results confirm the superior performance of BP-LMS in positioning accuracy and error elimination.Compared with LMS and normalized least mean square(NLMS),the filtering error of the proposed BP-LMS adaptive filtering method is decreased by 57.14%and 51.38%,respectively.展开更多
As an essential component of future comprehensive Positioning,Navigation,and Timing(PNT)system,indoor positioning technology has extensive application demands,making it a focal point of attention in both academia and ...As an essential component of future comprehensive Positioning,Navigation,and Timing(PNT)system,indoor positioning technology has extensive application demands,making it a focal point of attention in both academia and industry.This article comprehensively reviews the research status of indoor positioning technology in China,with a focus on highlighting representative achievements and application validations from major research institutions in recent years.It addresses the challenges and issues faced in promotion and application of large-scale,high-precision indoor positioning.Furthermore,a universal and seamless indoor-outdoor positioning system architecture is proposed,along with a technical roadmap and key technologies to achieve this architecture.Finally,an analysis and outlook on future technological trends are presented.展开更多
This article focuses on the performance analysis of both real-time and post-mission kinematic precise point positioning(PPP)in challenging marine environments.For this purpose,a real dynamic experiment lasting 6 h was...This article focuses on the performance analysis of both real-time and post-mission kinematic precise point positioning(PPP)in challenging marine environments.For this purpose,a real dynamic experiment lasting 6 h was carried out on a lake dam in?orum City of Turkey.While the kinematic test was continuing,the real-time PPP coordinates were obtained for each measurement epoch with a commercial real-time PPP(RT-PPP)service,namely the Trimble Center Point RTX.Then the post-mission PPP(PM-PPP)coordinates were calculated by using Multi-GNSS data and the Multi-GNSS Experiment(MGEX)precise products.The kinematic RT-PPP and PM-PPP results showed that the PPP coordinates were consistent with the relative solution at centimetre and decimetre level in horizontal and height components,respectively.This study implies that PPP technique is a powerful tool for highly accurate positioning in both real-time and post-mission modes,even for dynamic applications in harsh environments.展开更多
This study explored beliefs and actual practices of young women on utilization of Prevention of Mother to Child Transmission (PMTCT) of HIV services in Balaka district of Southern Malawi. The study design wascross sec...This study explored beliefs and actual practices of young women on utilization of Prevention of Mother to Child Transmission (PMTCT) of HIV services in Balaka district of Southern Malawi. The study design wascross sectional which utilized qualitative data collection and analysis methods. In-depth interviews were conducted on 12 young mothers of 15 to 24 years old. The respondents were drawn from 6 health centres in the district during their visits to either the under-five clinic, HIV and AIDS support groups or HIV follow up clinics. Data were analyzed using thematic analysis approach. Overall the respondents had positive beliefs on utilization of PMTCT services. They believed that adherence to PMTCT guidelines such as condom use, taking of Nevirapine (NVP) and exclusive breastfeeding protected the baby from contracting the virus. Nevertheless, all respondents believed that HIV testing was mandatory and that early weaning caused malnutrition and death of babies. Actual practice was very low. Very few young mothers breastfed exclusively, weaned their babies abruptly and took NVP as recommended. Not all positive beliefs translated into positive behavior. Lack of male support, inability of the midwives to provide comprehensive care to HIV infected mothers and their infants, and fear of stigma and discrimination were other factors that hindered utilization of PMTCT services. Culture was also a major barrier because traditionally babies are expected to be breastfed and supplements are fed to babies too. Therefore, there is a need to mobilize communities on PMTCT of HIV. Education programmes in HIV should emphasize behavior change interventions and should focus on both men and women and significant others. There is also need to intensify monitoring and evaluation of health workers’ activities to ensure that beliefs translate into positive behavior.展开更多
Considering the need of target positioning,a remote positioning system is designed based on global positioning system(GPS)and general packet radio service(GPRS);The data collection terminal is based on microcontroller...Considering the need of target positioning,a remote positioning system is designed based on global positioning system(GPS)and general packet radio service(GPRS);The data collection terminal is based on microcontroller unit(MCU)PIC24FV301.It uses GPRS network to create wireless link and transmits GPS source information which is collected by LEA-5H board to monitor center on the Internet.The monitor center obtains the target information through processing and analysis of the calculated data.Actual operation results indicate that the designed system has excellent performance and achieves the goal of the remote location.展开更多
BACKGROUND: To determine whether the prehospital use of continuous positive airway pressure(CPAP) therapy is associated with a reduced rate of endotracheal intubation in patients with an acute respiratory disorder bro...BACKGROUND: To determine whether the prehospital use of continuous positive airway pressure(CPAP) therapy is associated with a reduced rate of endotracheal intubation in patients with an acute respiratory disorder brought to the emergency department(ED).METHODS: We reviewed medical records of patients with acute respiratory distress who had been treated with CPAP in the Mobile Intensive Care Unit(MICU) from January 2010 to December 2011. These records were compared with those of patients who received standardized care without CPAP in the MICU from January 2004 to December 2004. Categorical variables were summarized as frequencies and compared between groups using Fisher's exact test or the Chi-square test. Continuous variables were summarized as medians(interquartile range), and comparison between the groups was made using Wilcoxon's rank-sum test. The relationship between CPAP and intubation rate was determined using multivariable logistic regression analysis of propensity scores. The results were presented as odds ratio(OR), 95% confidence interval(CI), and P value for test effect. The adequacy of the model was calibrated using Hosmer and Lemeshow's goodness-of-fit test. P<0.05 was considered statistically significant.RESULTS: The records of 785 patients were reviewed. Of the 215 patients treated with CPAP in the MICU, 13% were intubated after admission. In contrast, of the 570 patients who did not receive CPAP, 28% were intubated after ED admission. Unadjusted logistic regression analysis showed that patients who had been treated with CPAP were less likely to be intubated than those without CPAP treatment(OR=0.37, 95% CI, 0.24–0.57, P<0.0001). With propensity scores adjusted, multivariate logistic regression analysis showed that CPAP treatment was associated with a 62% reduction of intubation(OR=0.384, 95%CI, 0.25–0.60, P≤0.0001).CONCLUSIONS: In patients with acute respiratory disorder, there was a relationship between CPAP therapy and the decreased intubation rate. CPAP therapy was feasible in prehospital management of patients with respiratory distress.展开更多
The multi-antenna synchronized global navi- gation satellite system receiver is a high precision, low cost, and widely used emerging receiver. Using this type of receiver, the satellite and receiver clock errors can b...The multi-antenna synchronized global navi- gation satellite system receiver is a high precision, low cost, and widely used emerging receiver. Using this type of receiver, the satellite and receiver clock errors can be eliminated simultaneously by forming between antenna single-differences, which is equivalent to the conventional double-difference model. However, current multi-antenna synchronized global navigation satellite system receiver products have not fully realized their potential to achieve better accuracy, efficiency, and broader applications. This paper introduces the conceptual design and derivable products of multi-antenna synchronized global navigation satellite system receivers involving the aspects of attitude determination, multipath effect mitigation, phase center variation correction, and ground-based carrier phase wind- up calibration. Through case studies, the advantages of multi-antenna synchronized global navigation satellite system receivers in high-precision positioning applications are demonstrated.展开更多
To satisfy different positioning accuracy demand in the movement of the service robot, a hierarchical localization method based on vision was proposed considering the positioning cost and computational efficiency. The...To satisfy different positioning accuracy demand in the movement of the service robot, a hierarchical localization method based on vision was proposed considering the positioning cost and computational efficiency. The hierarchical positioning method could be divided into two parts: the localization method based on global vision and the localization method based on binocular vision. The global vision-based localization method was applied to calculate the initial coordinates of the robot and realize real-time rough positioning with the dead-reckoning method in the first stage. In the last stage, the binocular vision-based localization method was adopted to obtain higher positioning accuracy to make sure that the service robot can successfully grab the object. Experiments indicate that the proposed algorithm can accurately evaluate the positioning performance, obtain up to ±2 cm positioning accuracy, and absolutely meet the positioning requirements of the indoor service robot.展开更多
With the development of social media,the TV public service advertisements play an important role in environmental pro⁃tection.The essay will analyze PSA about environmental protection from the perspective of Attitude ...With the development of social media,the TV public service advertisements play an important role in environmental pro⁃tection.The essay will analyze PSA about environmental protection from the perspective of Attitude in Appraisal System,trying to find out how ads work by using different kinds of sub-systems in attitude.And the essay will also focus on the proportion of positive and negative meanings,researching the myth of PSA.展开更多
基金supported by the International S&T Cooperation Program of China(GrantNo.2010DFB43660)National Natural Science Foundation of China(Grant No.51375286)Scientific Research Program Funded by Shaanxi Provincial Education Department(Program No.16JF005)
文摘Traditionally, basis weight control valve is driven by a constant frequency pulse signal. Therefore, it is difficult for the valve to match the control precision of basis weight. Dynamic simulation research using Matlab/Simulink indicates that there is much more overshoot and fluctuating during the valve-positioning process. In order to improve the valve-positioning precision, the control method of trapezoidal velocity curve was studied. The simulation result showed that the positioning steady-state error was less than 0.0056%, whereas the peak error was less than 0.016% by using trapezoidal velocity curve at 10 positioning steps. A valve-positioning precision experimental device for the stepper motor of basis weight control valve was developed. The experiment results showed that the error ratio of 1/10000 positioning steps was 4% by using trapezoidal velocity curve. Furthermore, the error ratio of 10/10000 positioning steps was 0.5%. It proved that the valve-positioning precision of trapezoidal velocity curve was much higher than that of the constant frequency pulse signal control strategy. The new control method of trapezoidal velocity curve can satisfy the precision requirement of 10000 steps.
基金supported by the Science and Technology Project of the China Southern Power Grid Company Limited under Grant Number(GDKJXM20202001).
文摘The BeiDou-3 navigation satellite system(BDS-3)provides a full-domain high-precision positioning service for the power system to ensure safe and stable operation.However,BDS-3 power system positioning faces certain challenges,such as complex electromagnetic interference and incomplete error elimination.Herein,a back propagation neural network-improved least mean square(BP-LMS)adaptive filtering method is proposed for the BDS-3 full-domain and high-precision power system positioning,which utilizes the loss function to update the weight of the BP hidden layer,computes the pseudo compensation range,and eliminates the impact of electromagnetic interference to enhance the accuracy of power system positioning.Simulation results confirm the superior performance of BP-LMS in positioning accuracy and error elimination.Compared with LMS and normalized least mean square(NLMS),the filtering error of the proposed BP-LMS adaptive filtering method is decreased by 57.14%and 51.38%,respectively.
基金National Key Research and Development Plan Project:High-precision Positioning Navigation and Control Technology for Large Underground Spaces(No.2021YFB3900800)。
文摘As an essential component of future comprehensive Positioning,Navigation,and Timing(PNT)system,indoor positioning technology has extensive application demands,making it a focal point of attention in both academia and industry.This article comprehensively reviews the research status of indoor positioning technology in China,with a focus on highlighting representative achievements and application validations from major research institutions in recent years.It addresses the challenges and issues faced in promotion and application of large-scale,high-precision indoor positioning.Furthermore,a universal and seamless indoor-outdoor positioning system architecture is proposed,along with a technical roadmap and key technologies to achieve this architecture.Finally,an analysis and outlook on future technological trends are presented.
文摘This article focuses on the performance analysis of both real-time and post-mission kinematic precise point positioning(PPP)in challenging marine environments.For this purpose,a real dynamic experiment lasting 6 h was carried out on a lake dam in?orum City of Turkey.While the kinematic test was continuing,the real-time PPP coordinates were obtained for each measurement epoch with a commercial real-time PPP(RT-PPP)service,namely the Trimble Center Point RTX.Then the post-mission PPP(PM-PPP)coordinates were calculated by using Multi-GNSS data and the Multi-GNSS Experiment(MGEX)precise products.The kinematic RT-PPP and PM-PPP results showed that the PPP coordinates were consistent with the relative solution at centimetre and decimetre level in horizontal and height components,respectively.This study implies that PPP technique is a powerful tool for highly accurate positioning in both real-time and post-mission modes,even for dynamic applications in harsh environments.
文摘This study explored beliefs and actual practices of young women on utilization of Prevention of Mother to Child Transmission (PMTCT) of HIV services in Balaka district of Southern Malawi. The study design wascross sectional which utilized qualitative data collection and analysis methods. In-depth interviews were conducted on 12 young mothers of 15 to 24 years old. The respondents were drawn from 6 health centres in the district during their visits to either the under-five clinic, HIV and AIDS support groups or HIV follow up clinics. Data were analyzed using thematic analysis approach. Overall the respondents had positive beliefs on utilization of PMTCT services. They believed that adherence to PMTCT guidelines such as condom use, taking of Nevirapine (NVP) and exclusive breastfeeding protected the baby from contracting the virus. Nevertheless, all respondents believed that HIV testing was mandatory and that early weaning caused malnutrition and death of babies. Actual practice was very low. Very few young mothers breastfed exclusively, weaned their babies abruptly and took NVP as recommended. Not all positive beliefs translated into positive behavior. Lack of male support, inability of the midwives to provide comprehensive care to HIV infected mothers and their infants, and fear of stigma and discrimination were other factors that hindered utilization of PMTCT services. Culture was also a major barrier because traditionally babies are expected to be breastfed and supplements are fed to babies too. Therefore, there is a need to mobilize communities on PMTCT of HIV. Education programmes in HIV should emphasize behavior change interventions and should focus on both men and women and significant others. There is also need to intensify monitoring and evaluation of health workers’ activities to ensure that beliefs translate into positive behavior.
文摘Considering the need of target positioning,a remote positioning system is designed based on global positioning system(GPS)and general packet radio service(GPRS);The data collection terminal is based on microcontroller unit(MCU)PIC24FV301.It uses GPRS network to create wireless link and transmits GPS source information which is collected by LEA-5H board to monitor center on the Internet.The monitor center obtains the target information through processing and analysis of the calculated data.Actual operation results indicate that the designed system has excellent performance and achieves the goal of the remote location.
文摘BACKGROUND: To determine whether the prehospital use of continuous positive airway pressure(CPAP) therapy is associated with a reduced rate of endotracheal intubation in patients with an acute respiratory disorder brought to the emergency department(ED).METHODS: We reviewed medical records of patients with acute respiratory distress who had been treated with CPAP in the Mobile Intensive Care Unit(MICU) from January 2010 to December 2011. These records were compared with those of patients who received standardized care without CPAP in the MICU from January 2004 to December 2004. Categorical variables were summarized as frequencies and compared between groups using Fisher's exact test or the Chi-square test. Continuous variables were summarized as medians(interquartile range), and comparison between the groups was made using Wilcoxon's rank-sum test. The relationship between CPAP and intubation rate was determined using multivariable logistic regression analysis of propensity scores. The results were presented as odds ratio(OR), 95% confidence interval(CI), and P value for test effect. The adequacy of the model was calibrated using Hosmer and Lemeshow's goodness-of-fit test. P<0.05 was considered statistically significant.RESULTS: The records of 785 patients were reviewed. Of the 215 patients treated with CPAP in the MICU, 13% were intubated after admission. In contrast, of the 570 patients who did not receive CPAP, 28% were intubated after ED admission. Unadjusted logistic regression analysis showed that patients who had been treated with CPAP were less likely to be intubated than those without CPAP treatment(OR=0.37, 95% CI, 0.24–0.57, P<0.0001). With propensity scores adjusted, multivariate logistic regression analysis showed that CPAP treatment was associated with a 62% reduction of intubation(OR=0.384, 95%CI, 0.25–0.60, P≤0.0001).CONCLUSIONS: In patients with acute respiratory disorder, there was a relationship between CPAP therapy and the decreased intubation rate. CPAP therapy was feasible in prehospital management of patients with respiratory distress.
基金Acknowledgements This work is sponsored by the National Natural Science Foundation of China (Grant Nos. 61372086, 11373017, 41201380, 41171327, and 41201379), Foundation of Science and Technology Commission of Shanghai (Nos. 13511500300 and 15511101602), Open Research Funding of the Key Laboratory of Embedded System and Service Computing (No. 48505280) and Open Research Funding Program of KLGIS (No. KLGIS2014A02).
文摘The multi-antenna synchronized global navi- gation satellite system receiver is a high precision, low cost, and widely used emerging receiver. Using this type of receiver, the satellite and receiver clock errors can be eliminated simultaneously by forming between antenna single-differences, which is equivalent to the conventional double-difference model. However, current multi-antenna synchronized global navigation satellite system receiver products have not fully realized their potential to achieve better accuracy, efficiency, and broader applications. This paper introduces the conceptual design and derivable products of multi-antenna synchronized global navigation satellite system receivers involving the aspects of attitude determination, multipath effect mitigation, phase center variation correction, and ground-based carrier phase wind- up calibration. Through case studies, the advantages of multi-antenna synchronized global navigation satellite system receivers in high-precision positioning applications are demonstrated.
基金National Natural Science Foundations of China ( No. 61105101,No. 61075086,No. 60875058 )Hi-Tech Research and Development Programs of China ( No. 2007AA041601,No. 2007AA041602,No. 2007AA041603 )+1 种基金State Key Laboratory of Robotics and System ( HIT) ,China ( No. SKLRS-2010-ZD-06)New Centrury Excellent Talents in University,China
文摘To satisfy different positioning accuracy demand in the movement of the service robot, a hierarchical localization method based on vision was proposed considering the positioning cost and computational efficiency. The hierarchical positioning method could be divided into two parts: the localization method based on global vision and the localization method based on binocular vision. The global vision-based localization method was applied to calculate the initial coordinates of the robot and realize real-time rough positioning with the dead-reckoning method in the first stage. In the last stage, the binocular vision-based localization method was adopted to obtain higher positioning accuracy to make sure that the service robot can successfully grab the object. Experiments indicate that the proposed algorithm can accurately evaluate the positioning performance, obtain up to ±2 cm positioning accuracy, and absolutely meet the positioning requirements of the indoor service robot.
文摘With the development of social media,the TV public service advertisements play an important role in environmental pro⁃tection.The essay will analyze PSA about environmental protection from the perspective of Attitude in Appraisal System,trying to find out how ads work by using different kinds of sub-systems in attitude.And the essay will also focus on the proportion of positive and negative meanings,researching the myth of PSA.