Orthogonal Time Frequency and Space(OTFS) modulation is expected to provide high-speed and ultra-reliable communications for emerging mobile applications, including low-orbit satellite communications. Using the Dopple...Orthogonal Time Frequency and Space(OTFS) modulation is expected to provide high-speed and ultra-reliable communications for emerging mobile applications, including low-orbit satellite communications. Using the Doppler frequency for positioning is a promising research direction on communication and navigation integration. To tackle the high Doppler frequency and low signal-to-noise ratio(SNR) in satellite communication, this paper proposes a Red and Blue Frequency Shift Discriminator(RBFSD) based on the pseudo-noise(PN) sequence.The paper derives that the cross-correlation function on the Doppler domain exhibits the characteristic of a Sinc function. Therefore, it applies modulation onto the Delay-Doppler domain using PN sequence and adjusts Doppler frequency estimation by red-shifting or blue-shifting. Simulation results show that the performance of Doppler frequency estimation is close to the Cramér-Rao Lower Bound when the SNR is greater than -15dB. The proposed algorithm is about 1/D times less complex than the existing PN pilot sequence algorithm, where D is the resolution of the fractional Doppler.展开更多
High-precision time transfer plays an important role in the areas of fundamental research and applications. Accompanying w ith the remarkable improvements in the ability of generating and measuring high-accuracy time-...High-precision time transfer plays an important role in the areas of fundamental research and applications. Accompanying w ith the remarkable improvements in the ability of generating and measuring high-accuracy time-frequency signal,seeking for new time-transfer techniques betw een distant clocks w ith much further improved accuracy attracts attentions w orld-w idely. The time-transfer technique based on optical pulses has the highest precision presently,and the further improvement in the accuracy is heavily dependent on the time-domain properties of the pulse as w ell as the sensitivity of the applied measurement on the exchanged pulse. The application of optical frequency comb in time transfer for a precision up to femtosecond level are currently the focus of much interest,and has recently achieved many breakthroughs. Further investigations show that,utilizing quantum techniques,i.e. quantum measurement technique and quantum optical pulse source,can lead to a new limit on the measured timing information. Furthermore,it can be immune from atmospheric parameters,such as pressure,temperature,humidity and so on.Such quantum improvements on time-transfer have a bright prospect in the future applications requiring extremely high-accuracy timing and ranging. The potential achievements w ill form a technical basis for the future realization of sub-femtosecond time transfer system.展开更多
The neutron flux monitor(NFM)system is an important diagnostic subsystem introduced by large nuclear fusion devices such as international thermonuclear experimental reactor(ITER),Japan torus-60,tokamak fusion test rea...The neutron flux monitor(NFM)system is an important diagnostic subsystem introduced by large nuclear fusion devices such as international thermonuclear experimental reactor(ITER),Japan torus-60,tokamak fusion test reactor,and HL-2 A.Neutron fluxes can provide real-time parameters for nuclear fusion,including neutron source intensity and fusion power.Corresponding to different nuclear reaction periods,neutron fluxes span over seven decades,thereby requiring electronic devices to operate in counting and Campbelling modes simultaneously.Therefore,it is crucial to design a real-time NFM system to encompass such a wide dynamic range.In this study,a high-precision NFM system with a wide measurement range of neutron flux is implemented using realtime multipoint linear calibration.It can automatically switch between counting and Campbelling modes with variations in the neutron flux.We established a testing platform to verify the feasibility of the NFM system,which can output the simulated neutron signal using an arbitrary waveform generator.Meanwhile,the accurate calibration interval of the Campbelling mode is defined well.Based on the above-mentioned design,the system satisfies the requirements,offering a dynamic range of 10~8 cps,temporal resolution of 1 ms,and maximal relative error of 4%measured at the signal-to-noise ratio of 15.8 dB.Additionally,the NFM system is verified in a field experiment involving HL-2 A,and the measured neutron flux is consistent with the results.展开更多
Based on the evaluation of advantages and disadvantages of high-precision digital time interval measuring algorithms, and combined with the principle of the typical time-difference ultrasonic flow measurement, the req...Based on the evaluation of advantages and disadvantages of high-precision digital time interval measuring algorithms, and combined with the principle of the typical time-difference ultrasonic flow measurement, the requirements for the measurement of echo time of flight put forward by the ultrasonic flow measurement are analyzed. A new high-precision time interval measurement algorithm is presented, which combines the pulse counting method with the phase delay interpolation. The pulse counting method is used to ensure a large dynamic measuring range, and a double-edge triggering counter is designed to improve the accuracy and reduce the counting quantization error. The phase delay interpolation is used to reduce the quantization error of pulse counting for further improving the time measurement resolution. Test data show that the systexn for the measurement of the ultrasonic echo time of flight based on this algorithm and implemented on an Field Programmable Gate Army(FleA) needs a relatively short time for measurement, and has a measurement error of less than 105 ps.展开更多
In order to improve the reliability of the spacecraft micro cold gas propulsion system and realize the precise control of the spacecraft attitude and orbit, a micro-thrust, high-precision cold gas thruster is carried ...In order to improve the reliability of the spacecraft micro cold gas propulsion system and realize the precise control of the spacecraft attitude and orbit, a micro-thrust, high-precision cold gas thruster is carried out, at the same time due to the design requirements of the spacecraft, this micro-thrust should be continuous working more than 60 minutes, the traditional solenoid valve used for the thrusts can’t complete the mission, so a long-life micro latching valve is developed as the control valve for this micro thruster, because the micro latching valve can keep its position when it cuts off the outage. Firstly, the authors introduced the design scheme and idea of the thruster. Secondly, the performance of the latching valve and the flow characteristics of the nozzle were simulated. Finally, from the experimental results and compared with the numerical study, it shows that the long-life micro cold gas thruster developed in this paper meets the mission requirements.展开更多
This study identified castor oil and phosphate ester as effective retarders through setting time,tensile,and flexural tests,and determined their optimal dosages.The mechanism by which phosphate ester affects the setti...This study identified castor oil and phosphate ester as effective retarders through setting time,tensile,and flexural tests,and determined their optimal dosages.The mechanism by which phosphate ester affects the setting time of polyurethane was further investigated using molecular dynamics simulations.Fourier transform infrared spectroscopy was also employed to systematically study the physical and chemical interactions between phosphate esters and polyurethane materials.The results demonstrate that a 1%concentration of phosphate ester provides the most effective retarding effect with minimal impact on the strength of polyurethane.When phosphate ester is added to the B component of the two-component polyurethane system,its interaction energy with component A decreases,as do the diffusion coefficient and aggregation degree of component B on the surface of component A.This reduction in interaction slows the setting time.Additionally,the addition of phosphate ester to polyurethane leads to the disappearance or weakening of functional groups,indicating competitive interactions within the phosphate ester components that inhibit the reaction rate.展开更多
To improve the estimation accuracy,a novel time delay estimation(TDE)method based on the closed-form offset compensation is proposed.Firstly,we use the generalized cross-correlation with phase transform(GCC-PHAT)metho...To improve the estimation accuracy,a novel time delay estimation(TDE)method based on the closed-form offset compensation is proposed.Firstly,we use the generalized cross-correlation with phase transform(GCC-PHAT)method to obtain the initial TDE.Secondly,a signal model using normalized cross spectrum is established,and the noise subspace is extracted by eigenvalue decomposition(EVD)of covariance matrix.Using the orthogonal relation between the steering vector and the noise subspace,the first-order Taylor expansion is carried out on the steering vector reconstructed by the initial TDE.Finally,the offsets are compensated via simple least squares(LS).Compared to other state-of-the-art methods,the proposed method significantly reduces the computational complexity and achieves better estimation performance.Experiments on both simulation and real-world data verify the efficiency of the proposed approach.展开更多
BACKGROUND Meniscal tears are one of the most common knee injuries.After the diagnosis of a meniscal tear has been made,there are several factors physicians use to guide clinical decision-making.The influence of time ...BACKGROUND Meniscal tears are one of the most common knee injuries.After the diagnosis of a meniscal tear has been made,there are several factors physicians use to guide clinical decision-making.The influence of time between injury and isolated meniscus repair on patient outcomes is not well described.Assessing this relationship is important as it may influence clinical decision-making and can add to the preoperative patient education process.We hypothesized that increasing the time from injury to meniscus surgery would worsen postoperative outcomes.AIM To investigate the current literature for data on the relationship between time between meniscus injury and repair on patient outcomes.METHODS PubMed,Academic Search Complete,MEDLINE,CINAHL,and SPORTDiscus were searched for studies published between January 1,1995 and July 13,2023 on isolated meniscus repair.Exclusion criteria included concomitant ligament surgery,incomplete outcomes or time to surgery data,and meniscectomies.Patient demographics,time to injury,and postoperative outcomes from each study were abstracted and analyzed.RESULTS Five studies met all inclusion and exclusion criteria.There were 204(121 male,83 female)patients included.Three of five(60%)studies determined that time between injury and surgery was not statistically significant for postoperative Lysholm scores(P=0.62),Tegner scores(P=0.46),failure rate(P=0.45,P=0.86),and International Knee Documentation Committee scores(P=0.65).Two of five(40%)studies found a statistically significant increase in Lysholm scores with shorter time to surgery(P=0.03)and a statistically significant association between progression of medial meniscus extrusion ratio(P=0.01)and increasing time to surgery.CONCLUSION Our results do not support the hypothesis that increased time from injury to isolated meniscus surgery worsens postoperative outcomes.Decision-making primarily based on injury interval is thus not recommended.展开更多
Several promising plasma biomarker proteins,such as amyloid-β(Aβ),tau,neurofilament light chain,and glial fibrillary acidic protein,are widely used for the diagnosis of neurodegenerative diseases.However,little is k...Several promising plasma biomarker proteins,such as amyloid-β(Aβ),tau,neurofilament light chain,and glial fibrillary acidic protein,are widely used for the diagnosis of neurodegenerative diseases.However,little is known about the long-term stability of these biomarker proteins in plasma samples stored at-80°C.We aimed to explore how storage time would affect the diagnostic accuracy of these biomarkers using a large cohort.Plasma samples from 229 cognitively unimpaired individuals,encompassing healthy controls and those experiencing subjective cognitive decline,as well as 99 patients with cognitive impairment,comprising those with mild cognitive impairment and dementia,were acquired from the Sino Longitudinal Study on Cognitive Decline project.These samples were stored at-80°C for up to 6 years before being used in this study.Our results showed that plasma levels of Aβ42,Aβ40,neurofilament light chain,and glial fibrillary acidic protein were not significantly correlated with sample storage time.However,the level of total tau showed a negative correlation with sample storage time.Notably,in individuals without cognitive impairment,plasma levels of total protein and tau phosphorylated protein threonine 181(p-tau181)also showed a negative correlation with sample storage time.This was not observed in individuals with cognitive impairment.Consequently,we speculate that the diagnostic accuracy of plasma p-tau181 and the p-tau181 to total tau ratio may be influenced by sample storage time.Therefore,caution is advised when using these plasma biomarkers for the identification of neurodegenerative diseases,such as Alzheimer's disease.Furthermore,in cohort studies,it is important to consider the impact of storage time on the overall results.展开更多
Working toward an efficient duration and timeline for the preconstruction phase should be one of the main objectives for project owners.Failing to plan for and coordinate preconstruction decisions in order to control ...Working toward an efficient duration and timeline for the preconstruction phase should be one of the main objectives for project owners.Failing to plan for and coordinate preconstruction decisions in order to control preconstruction duration and manage time variances can lead to financial insecurities,incomplete contract documents,permitting issues,and unrealistic schedules and resource allocation during this phase.To minimize time variances and ensure a productive decision-making process,project owners should be familiar with critical elements in a project that cause variances in the preconstruction phase timeline.In this study,the impacts of eleven critical preconstruction elements on time variances were analyzed.These eleven preconstruction elements are considered critical in how they impact time variances during the preconstruction phase.They were determined to be critical based either on significantly impacting time variance during the preconstruction phase or believed to be critical from findings from previous studies,however,the findings from this study showed no significant impact on the time variances.In most previous studies focusing on the elements impacting project schedules,data were collected by surveying construction professionals.In this study,objective and quantitative data related to project preconstruction elements were used as opposed to self-reported data.Using the results of this study,project owners and stakeholders will be able to evaluate the critical preconstruction elements impacting the timing of their projects and prioritize decisions related to the critical elements early on during the preconstruction phase.展开更多
The grain size of TiAl alloy castings prepared by traditional casting process is coarse,thus showing poor mechanical properties.In this study,a new type of high performance Ti-46Al alloy tube prepared by vacuum centri...The grain size of TiAl alloy castings prepared by traditional casting process is coarse,thus showing poor mechanical properties.In this study,a new type of high performance Ti-46Al alloy tube prepared by vacuum centrifugal casting technology was introduced.This research comprehensively examined the influence of pouring time on the microstructure and mechanical performance of the castings,employing both experimental approaches and ProCast simulation methodologies.The findings indicate that prolonging the pouring time facilitates a microstructural evolution from coarse columnar grains to refined equiaxed grains.Under the condition of pouring temperature of 1,600℃,rotation speed of 800 r·min^(-1) and pouring time of 6 s,the tensile strength of Ti-46Al alloy at room temperature reaches 650 MPa,and the tensile strength at 800℃ reaches 705 MPa,which is significantly higher than that of traditional as-cast Ti-Al alloy.展开更多
To address the problem of multi-missile cooperative interception against maneuvering targets at a prespecified impact time and desired Line-of-Sight(LOS)angles in ThreeDimensional(3D)space,this paper proposes a 3D lea...To address the problem of multi-missile cooperative interception against maneuvering targets at a prespecified impact time and desired Line-of-Sight(LOS)angles in ThreeDimensional(3D)space,this paper proposes a 3D leader-following cooperative interception guidance law.First,in the LOS direction of the leader,an impact time-controlled guidance law is derived based on the fixed-time stability theory,which enables the leader to complete the interception task at a prespecified impact time.Next,in the LOS direction of the followers,by introducing a time consensus tracking error function,a fixed-time consensus tracking guidance law is investigated to guarantee the consensus tracking convergence of the time-to-go.Then,in the direction normal to the LOS,by combining the designed global integral sliding mode surface and the second-order Sliding Mode Control(SMC)theory,an innovative 3D LOS-angle-constrained interception guidance law is developed,which eliminates the reaching phase in the traditional sliding mode guidance laws and effectively saves energy consumption.Moreover,it effectively suppresses the chattering phenomenon while avoiding the singularity issue,and compensates for unknown interference caused by target maneuvering online,making it convenient for practical engineering applications.Finally,theoretical proof analysis and multiple sets of numerical simulation results verify the effectiveness,superiority,and robustness of the investigated guidance law.展开更多
To realize high-precision automatic measurement of two-dimensional geometric features on parts, a cooperative measurement system based on machine vision is constructed. Its hardware structure, functional composition a...To realize high-precision automatic measurement of two-dimensional geometric features on parts, a cooperative measurement system based on machine vision is constructed. Its hardware structure, functional composition and working principle are introduced. The mapping relationship between the feature image coordinates and the measuring space coordinates is established. The method of measuring path planning of small field of view (FOV) images is proposed. With the cooperation of the panoramic image of the object to be measured, the small FOV images with high object plane resolution are acquired automatically. Then, the auxiliary measuring characteristics are constructed and the parameters of the features to be measured are automatically extracted. Experimental results show that the absolute value of relative error is less than 0. 03% when applying the cooperative measurement system to gauge the hole distance of 100 mm nominal size. When the object plane resolving power of the small FOV images is 16 times that of the large FOV image, the measurement accuracy of small FOV images is improved by 14 times compared with the large FOV image. It is suitable for high-precision automatic measurement of two-dimensional complex geometric features distributed on large scale parts.展开更多
Multi-sensor coordinate unification in dimensional metrology is used in order to get holistic, more accurate and reliable information about a workpiece based on several or multiple measurement values from ...Multi-sensor coordinate unification in dimensional metrology is used in order to get holistic, more accurate and reliable information about a workpiece based on several or multiple measurement values from one or more sensors. Because of the problem that standard ball is deficient as a standard artifact in the coordinate unification of high-precision composite measurement in two dimensions (2D) , a new method is proposed in this paper which uses angle gauge blocks as standard artifacts to achieve coordinate unification between the image sensor and the tactile probe. By comparing the standard ball with the angle gauge block as a standard artifact, theoretical analysis and experimental results are given to prove that it is more precise and more convenient to use angle gauge blocks as standard artifacts to achieve coordinate unification of high-precision composite measurement in two dimensions.展开更多
The Tibetan Plateau(TP)is the youngest orogenic belt resulting from a continental collision on the Earth.It is a natural laboratory for studying continental dynamics,such as continental convergence,plate subduction,an...The Tibetan Plateau(TP)is the youngest orogenic belt resulting from a continental collision on the Earth.It is a natural laboratory for studying continental dynamics,such as continental convergence,plate subduction,and plateau uplift.Investigating the deep structure of the TP has always been a popular issue in geological research.The Moho is the boundary between the crust and the mantle and therefore plays a crucial role in the Earth’s structure.Parameters such as depth and lateral variation,as well as the fine structure of the crust-mantle interface,reveal the lithospheric dynamics in the TP.Two methods are generally employed to study the Moho surface:seismic detection and gravity inversion.Seismic detection has the characteristic of high precision,but it is limited to a few cross-sectional lines and is quite costly.It is not suitable for and cannot be carried out over a large area of the TP.The Moho depth over a large area can be obtained through gravity inversion,but this method is affected by the nature of gravity data,and the accuracy of the inversion method is lower than that of seismic detection.In this work,a high-precision gravity field model was selected.The Parker-Oldenburg interface inversion method was used,within the constraints of seismic observations,and the Bott iteration method was introduced to enhance the inversion efficiency.The Moho depth in the TP was obtained with high precision,consistent with the seismic detection results.The research results showed that the shape of the Moho in the TP is complex and the variation range is large,reaching 60−80 km.In contrast with the adjacent area,a clear zone of sharp variation appears at the edge of the plateau.In the interior of the TP,the buried depth of the Moho is characterized by two depressions and two uplifts.To the south of the Yarlung Zangbo River,the Moho inclines to the north,and to the north,the Moho depresses downward,which was interpreted as the Indian plate subducting to the north below Tibet.The Moho depression on the north side of the Qiangtang block,reaching 72 km deep,may be a result of the southward subduction of the lithosphere.The Moho uplift of the Qiangtang block has the same strike as the Bangong−Nujiang suture zone,which may indicate that the area is compensated by a low-density and low-velocity mantle.展开更多
A reliable multiphase flow simulator is an important tool to improve wellbore integrity and production decision-making.To develop a multiphase flow model with high adaptability and high accuracy,we first build a multi...A reliable multiphase flow simulator is an important tool to improve wellbore integrity and production decision-making.To develop a multiphase flow model with high adaptability and high accuracy,we first build a multiphase flow database with 3561 groups of data and developed a drift closure relationship with stable continuity and high adaptability.Second,a high-order numerical scheme with strong fault capture ability is constructed by effectively combining MUSCL technology,van Albada slope limiter and AUSMV numerical scheme.Finally,the energy equation is coupled into the AUSMV numerical scheme of the drift flow model in the form of finite difference.A transient non-isothermal wellbore multiphase flow model with wide applicability is formed by integrating the three technologies,and the effects of various factors on the calculation accuracy are studied.The accuracy of the simulator is verified by comparing the measurement results with the blowout experiment of a full-scale experimental well.展开更多
文摘Orthogonal Time Frequency and Space(OTFS) modulation is expected to provide high-speed and ultra-reliable communications for emerging mobile applications, including low-orbit satellite communications. Using the Doppler frequency for positioning is a promising research direction on communication and navigation integration. To tackle the high Doppler frequency and low signal-to-noise ratio(SNR) in satellite communication, this paper proposes a Red and Blue Frequency Shift Discriminator(RBFSD) based on the pseudo-noise(PN) sequence.The paper derives that the cross-correlation function on the Doppler domain exhibits the characteristic of a Sinc function. Therefore, it applies modulation onto the Delay-Doppler domain using PN sequence and adjusts Doppler frequency estimation by red-shifting or blue-shifting. Simulation results show that the performance of Doppler frequency estimation is close to the Cramér-Rao Lower Bound when the SNR is greater than -15dB. The proposed algorithm is about 1/D times less complex than the existing PN pilot sequence algorithm, where D is the resolution of the fractional Doppler.
文摘High-precision time transfer plays an important role in the areas of fundamental research and applications. Accompanying w ith the remarkable improvements in the ability of generating and measuring high-accuracy time-frequency signal,seeking for new time-transfer techniques betw een distant clocks w ith much further improved accuracy attracts attentions w orld-w idely. The time-transfer technique based on optical pulses has the highest precision presently,and the further improvement in the accuracy is heavily dependent on the time-domain properties of the pulse as w ell as the sensitivity of the applied measurement on the exchanged pulse. The application of optical frequency comb in time transfer for a precision up to femtosecond level are currently the focus of much interest,and has recently achieved many breakthroughs. Further investigations show that,utilizing quantum techniques,i.e. quantum measurement technique and quantum optical pulse source,can lead to a new limit on the measured timing information. Furthermore,it can be immune from atmospheric parameters,such as pressure,temperature,humidity and so on.Such quantum improvements on time-transfer have a bright prospect in the future applications requiring extremely high-accuracy timing and ranging. The potential achievements w ill form a technical basis for the future realization of sub-femtosecond time transfer system.
基金supported by the National Natural Science Foundation of China(Nos.11475131,11975307,and 11575184)the National Magnetic Confinement Fusion Energy Development Research(No.2013GB104003)。
文摘The neutron flux monitor(NFM)system is an important diagnostic subsystem introduced by large nuclear fusion devices such as international thermonuclear experimental reactor(ITER),Japan torus-60,tokamak fusion test reactor,and HL-2 A.Neutron fluxes can provide real-time parameters for nuclear fusion,including neutron source intensity and fusion power.Corresponding to different nuclear reaction periods,neutron fluxes span over seven decades,thereby requiring electronic devices to operate in counting and Campbelling modes simultaneously.Therefore,it is crucial to design a real-time NFM system to encompass such a wide dynamic range.In this study,a high-precision NFM system with a wide measurement range of neutron flux is implemented using realtime multipoint linear calibration.It can automatically switch between counting and Campbelling modes with variations in the neutron flux.We established a testing platform to verify the feasibility of the NFM system,which can output the simulated neutron signal using an arbitrary waveform generator.Meanwhile,the accurate calibration interval of the Campbelling mode is defined well.Based on the above-mentioned design,the system satisfies the requirements,offering a dynamic range of 10~8 cps,temporal resolution of 1 ms,and maximal relative error of 4%measured at the signal-to-noise ratio of 15.8 dB.Additionally,the NFM system is verified in a field experiment involving HL-2 A,and the measured neutron flux is consistent with the results.
基金supported by the National 863 Program(No.2008AA042207)
文摘Based on the evaluation of advantages and disadvantages of high-precision digital time interval measuring algorithms, and combined with the principle of the typical time-difference ultrasonic flow measurement, the requirements for the measurement of echo time of flight put forward by the ultrasonic flow measurement are analyzed. A new high-precision time interval measurement algorithm is presented, which combines the pulse counting method with the phase delay interpolation. The pulse counting method is used to ensure a large dynamic measuring range, and a double-edge triggering counter is designed to improve the accuracy and reduce the counting quantization error. The phase delay interpolation is used to reduce the quantization error of pulse counting for further improving the time measurement resolution. Test data show that the systexn for the measurement of the ultrasonic echo time of flight based on this algorithm and implemented on an Field Programmable Gate Army(FleA) needs a relatively short time for measurement, and has a measurement error of less than 105 ps.
文摘In order to improve the reliability of the spacecraft micro cold gas propulsion system and realize the precise control of the spacecraft attitude and orbit, a micro-thrust, high-precision cold gas thruster is carried out, at the same time due to the design requirements of the spacecraft, this micro-thrust should be continuous working more than 60 minutes, the traditional solenoid valve used for the thrusts can’t complete the mission, so a long-life micro latching valve is developed as the control valve for this micro thruster, because the micro latching valve can keep its position when it cuts off the outage. Firstly, the authors introduced the design scheme and idea of the thruster. Secondly, the performance of the latching valve and the flow characteristics of the nozzle were simulated. Finally, from the experimental results and compared with the numerical study, it shows that the long-life micro cold gas thruster developed in this paper meets the mission requirements.
基金Funded by the National Natural Science Foundation of China(No.52370128)the Fundamental Research Funds for the Central Universities(No.2572022AW54)。
文摘This study identified castor oil and phosphate ester as effective retarders through setting time,tensile,and flexural tests,and determined their optimal dosages.The mechanism by which phosphate ester affects the setting time of polyurethane was further investigated using molecular dynamics simulations.Fourier transform infrared spectroscopy was also employed to systematically study the physical and chemical interactions between phosphate esters and polyurethane materials.The results demonstrate that a 1%concentration of phosphate ester provides the most effective retarding effect with minimal impact on the strength of polyurethane.When phosphate ester is added to the B component of the two-component polyurethane system,its interaction energy with component A decreases,as do the diffusion coefficient and aggregation degree of component B on the surface of component A.This reduction in interaction slows the setting time.Additionally,the addition of phosphate ester to polyurethane leads to the disappearance or weakening of functional groups,indicating competitive interactions within the phosphate ester components that inhibit the reaction rate.
基金supported in part by National Key R&D Program of China under Grants 2020YFB1807602 and 2020YFB1807600National Science Foundation of China(61971217,61971218,61631020,61601167)+1 种基金the Fund of Sonar Technology Key Laboratory(Range estimation and location technology of passive target viamultiple array combination),Jiangsu Planned Projects for Postdoctoral Research Funds(2020Z013)China Postdoctoral Science Foundation(2020M681585).
文摘To improve the estimation accuracy,a novel time delay estimation(TDE)method based on the closed-form offset compensation is proposed.Firstly,we use the generalized cross-correlation with phase transform(GCC-PHAT)method to obtain the initial TDE.Secondly,a signal model using normalized cross spectrum is established,and the noise subspace is extracted by eigenvalue decomposition(EVD)of covariance matrix.Using the orthogonal relation between the steering vector and the noise subspace,the first-order Taylor expansion is carried out on the steering vector reconstructed by the initial TDE.Finally,the offsets are compensated via simple least squares(LS).Compared to other state-of-the-art methods,the proposed method significantly reduces the computational complexity and achieves better estimation performance.Experiments on both simulation and real-world data verify the efficiency of the proposed approach.
文摘BACKGROUND Meniscal tears are one of the most common knee injuries.After the diagnosis of a meniscal tear has been made,there are several factors physicians use to guide clinical decision-making.The influence of time between injury and isolated meniscus repair on patient outcomes is not well described.Assessing this relationship is important as it may influence clinical decision-making and can add to the preoperative patient education process.We hypothesized that increasing the time from injury to meniscus surgery would worsen postoperative outcomes.AIM To investigate the current literature for data on the relationship between time between meniscus injury and repair on patient outcomes.METHODS PubMed,Academic Search Complete,MEDLINE,CINAHL,and SPORTDiscus were searched for studies published between January 1,1995 and July 13,2023 on isolated meniscus repair.Exclusion criteria included concomitant ligament surgery,incomplete outcomes or time to surgery data,and meniscectomies.Patient demographics,time to injury,and postoperative outcomes from each study were abstracted and analyzed.RESULTS Five studies met all inclusion and exclusion criteria.There were 204(121 male,83 female)patients included.Three of five(60%)studies determined that time between injury and surgery was not statistically significant for postoperative Lysholm scores(P=0.62),Tegner scores(P=0.46),failure rate(P=0.45,P=0.86),and International Knee Documentation Committee scores(P=0.65).Two of five(40%)studies found a statistically significant increase in Lysholm scores with shorter time to surgery(P=0.03)and a statistically significant association between progression of medial meniscus extrusion ratio(P=0.01)and increasing time to surgery.CONCLUSION Our results do not support the hypothesis that increased time from injury to isolated meniscus surgery worsens postoperative outcomes.Decision-making primarily based on injury interval is thus not recommended.
基金supported by the National Key Research&Development Program of China,Nos.2021YFC2501205(to YC),2022YFC24069004(to JL)the STI2030-Major Project,Nos.2021ZD0201101(to YC),2022ZD0211800(to YH)+2 种基金the National Natural Science Foundation of China(Major International Joint Research Project),No.82020108013(to YH)the Sino-German Center for Research Promotion,No.M-0759(to YH)a grant from Beijing Municipal Science&Technology Commission(Beijing Brain Initiative),No.Z201100005520018(to JL)。
文摘Several promising plasma biomarker proteins,such as amyloid-β(Aβ),tau,neurofilament light chain,and glial fibrillary acidic protein,are widely used for the diagnosis of neurodegenerative diseases.However,little is known about the long-term stability of these biomarker proteins in plasma samples stored at-80°C.We aimed to explore how storage time would affect the diagnostic accuracy of these biomarkers using a large cohort.Plasma samples from 229 cognitively unimpaired individuals,encompassing healthy controls and those experiencing subjective cognitive decline,as well as 99 patients with cognitive impairment,comprising those with mild cognitive impairment and dementia,were acquired from the Sino Longitudinal Study on Cognitive Decline project.These samples were stored at-80°C for up to 6 years before being used in this study.Our results showed that plasma levels of Aβ42,Aβ40,neurofilament light chain,and glial fibrillary acidic protein were not significantly correlated with sample storage time.However,the level of total tau showed a negative correlation with sample storage time.Notably,in individuals without cognitive impairment,plasma levels of total protein and tau phosphorylated protein threonine 181(p-tau181)also showed a negative correlation with sample storage time.This was not observed in individuals with cognitive impairment.Consequently,we speculate that the diagnostic accuracy of plasma p-tau181 and the p-tau181 to total tau ratio may be influenced by sample storage time.Therefore,caution is advised when using these plasma biomarkers for the identification of neurodegenerative diseases,such as Alzheimer's disease.Furthermore,in cohort studies,it is important to consider the impact of storage time on the overall results.
文摘Working toward an efficient duration and timeline for the preconstruction phase should be one of the main objectives for project owners.Failing to plan for and coordinate preconstruction decisions in order to control preconstruction duration and manage time variances can lead to financial insecurities,incomplete contract documents,permitting issues,and unrealistic schedules and resource allocation during this phase.To minimize time variances and ensure a productive decision-making process,project owners should be familiar with critical elements in a project that cause variances in the preconstruction phase timeline.In this study,the impacts of eleven critical preconstruction elements on time variances were analyzed.These eleven preconstruction elements are considered critical in how they impact time variances during the preconstruction phase.They were determined to be critical based either on significantly impacting time variance during the preconstruction phase or believed to be critical from findings from previous studies,however,the findings from this study showed no significant impact on the time variances.In most previous studies focusing on the elements impacting project schedules,data were collected by surveying construction professionals.In this study,objective and quantitative data related to project preconstruction elements were used as opposed to self-reported data.Using the results of this study,project owners and stakeholders will be able to evaluate the critical preconstruction elements impacting the timing of their projects and prioritize decisions related to the critical elements early on during the preconstruction phase.
基金financially supported by the Natural Science Foundation of China(52071065)the Fundamental Research Funds for the Central Universities(N2007007)the National Key R&D Program of China(2016YFB-0301201)。
文摘The grain size of TiAl alloy castings prepared by traditional casting process is coarse,thus showing poor mechanical properties.In this study,a new type of high performance Ti-46Al alloy tube prepared by vacuum centrifugal casting technology was introduced.This research comprehensively examined the influence of pouring time on the microstructure and mechanical performance of the castings,employing both experimental approaches and ProCast simulation methodologies.The findings indicate that prolonging the pouring time facilitates a microstructural evolution from coarse columnar grains to refined equiaxed grains.Under the condition of pouring temperature of 1,600℃,rotation speed of 800 r·min^(-1) and pouring time of 6 s,the tensile strength of Ti-46Al alloy at room temperature reaches 650 MPa,and the tensile strength at 800℃ reaches 705 MPa,which is significantly higher than that of traditional as-cast Ti-Al alloy.
文摘To address the problem of multi-missile cooperative interception against maneuvering targets at a prespecified impact time and desired Line-of-Sight(LOS)angles in ThreeDimensional(3D)space,this paper proposes a 3D leader-following cooperative interception guidance law.First,in the LOS direction of the leader,an impact time-controlled guidance law is derived based on the fixed-time stability theory,which enables the leader to complete the interception task at a prespecified impact time.Next,in the LOS direction of the followers,by introducing a time consensus tracking error function,a fixed-time consensus tracking guidance law is investigated to guarantee the consensus tracking convergence of the time-to-go.Then,in the direction normal to the LOS,by combining the designed global integral sliding mode surface and the second-order Sliding Mode Control(SMC)theory,an innovative 3D LOS-angle-constrained interception guidance law is developed,which eliminates the reaching phase in the traditional sliding mode guidance laws and effectively saves energy consumption.Moreover,it effectively suppresses the chattering phenomenon while avoiding the singularity issue,and compensates for unknown interference caused by target maneuvering online,making it convenient for practical engineering applications.Finally,theoretical proof analysis and multiple sets of numerical simulation results verify the effectiveness,superiority,and robustness of the investigated guidance law.
基金The National Natural Science Foundation of China(No.51175267)the Natural Science Foundation of Jiangsu Province(No.BK2010481)+2 种基金the Ph.D.Programs Foundation of Ministry of Education of China(No.20113219120004)China Postdoctoral Science Foundation(No.20100481148)the Postdoctoral Science Foundation of Jiangsu Province(No.1001004B)
文摘To realize high-precision automatic measurement of two-dimensional geometric features on parts, a cooperative measurement system based on machine vision is constructed. Its hardware structure, functional composition and working principle are introduced. The mapping relationship between the feature image coordinates and the measuring space coordinates is established. The method of measuring path planning of small field of view (FOV) images is proposed. With the cooperation of the panoramic image of the object to be measured, the small FOV images with high object plane resolution are acquired automatically. Then, the auxiliary measuring characteristics are constructed and the parameters of the features to be measured are automatically extracted. Experimental results show that the absolute value of relative error is less than 0. 03% when applying the cooperative measurement system to gauge the hole distance of 100 mm nominal size. When the object plane resolving power of the small FOV images is 16 times that of the large FOV image, the measurement accuracy of small FOV images is improved by 14 times compared with the large FOV image. It is suitable for high-precision automatic measurement of two-dimensional complex geometric features distributed on large scale parts.
基金National Key Scientific Instrument and Equipment Development Project(No.2013YQ170539)
文摘Multi-sensor coordinate unification in dimensional metrology is used in order to get holistic, more accurate and reliable information about a workpiece based on several or multiple measurement values from one or more sensors. Because of the problem that standard ball is deficient as a standard artifact in the coordinate unification of high-precision composite measurement in two dimensions (2D) , a new method is proposed in this paper which uses angle gauge blocks as standard artifacts to achieve coordinate unification between the image sensor and the tactile probe. By comparing the standard ball with the angle gauge block as a standard artifact, theoretical analysis and experimental results are given to prove that it is more precise and more convenient to use angle gauge blocks as standard artifacts to achieve coordinate unification of high-precision composite measurement in two dimensions.
基金the National Natural Science Foundation of China(Grant No.42192535)the Open Fund of Wuhan,Gravitation and Solid Earth Tides,National Observation and Research Station(No.WHYWZ202204)+1 种基金the Strategic Pioneer Science and Technology Special Project of the Chinese Academy of Sciences(Grant No.XDB18010304)the National Natural Science Foundation of China(Grant No.41874096).
文摘The Tibetan Plateau(TP)is the youngest orogenic belt resulting from a continental collision on the Earth.It is a natural laboratory for studying continental dynamics,such as continental convergence,plate subduction,and plateau uplift.Investigating the deep structure of the TP has always been a popular issue in geological research.The Moho is the boundary between the crust and the mantle and therefore plays a crucial role in the Earth’s structure.Parameters such as depth and lateral variation,as well as the fine structure of the crust-mantle interface,reveal the lithospheric dynamics in the TP.Two methods are generally employed to study the Moho surface:seismic detection and gravity inversion.Seismic detection has the characteristic of high precision,but it is limited to a few cross-sectional lines and is quite costly.It is not suitable for and cannot be carried out over a large area of the TP.The Moho depth over a large area can be obtained through gravity inversion,but this method is affected by the nature of gravity data,and the accuracy of the inversion method is lower than that of seismic detection.In this work,a high-precision gravity field model was selected.The Parker-Oldenburg interface inversion method was used,within the constraints of seismic observations,and the Bott iteration method was introduced to enhance the inversion efficiency.The Moho depth in the TP was obtained with high precision,consistent with the seismic detection results.The research results showed that the shape of the Moho in the TP is complex and the variation range is large,reaching 60−80 km.In contrast with the adjacent area,a clear zone of sharp variation appears at the edge of the plateau.In the interior of the TP,the buried depth of the Moho is characterized by two depressions and two uplifts.To the south of the Yarlung Zangbo River,the Moho inclines to the north,and to the north,the Moho depresses downward,which was interpreted as the Indian plate subducting to the north below Tibet.The Moho depression on the north side of the Qiangtang block,reaching 72 km deep,may be a result of the southward subduction of the lithosphere.The Moho uplift of the Qiangtang block has the same strike as the Bangong−Nujiang suture zone,which may indicate that the area is compensated by a low-density and low-velocity mantle.
基金The work was supported by the National Natural Science Foundation of China(No.51874045)National Natural Science Foundation-Youth Foundation(52104056)+2 种基金Department of Natural Resources of Guangdong Province(GDNRC[2021]56)Postdoctoral innovative talents support program in China(BX2021374)Scientific Research Program of Hubei Provincial Department of Education(T2021004).
文摘A reliable multiphase flow simulator is an important tool to improve wellbore integrity and production decision-making.To develop a multiphase flow model with high adaptability and high accuracy,we first build a multiphase flow database with 3561 groups of data and developed a drift closure relationship with stable continuity and high adaptability.Second,a high-order numerical scheme with strong fault capture ability is constructed by effectively combining MUSCL technology,van Albada slope limiter and AUSMV numerical scheme.Finally,the energy equation is coupled into the AUSMV numerical scheme of the drift flow model in the form of finite difference.A transient non-isothermal wellbore multiphase flow model with wide applicability is formed by integrating the three technologies,and the effects of various factors on the calculation accuracy are studied.The accuracy of the simulator is verified by comparing the measurement results with the blowout experiment of a full-scale experimental well.