High pressure die casting(HPDC)AlSi10Mn Mg alloy castings are widely used in the automobile industry.Mg can optimize the mechanical properties of castings through heat treatment,while the release of thermal stress aro...High pressure die casting(HPDC)AlSi10Mn Mg alloy castings are widely used in the automobile industry.Mg can optimize the mechanical properties of castings through heat treatment,while the release of thermal stress arouses the deformation of large integrated die-castings.Herein,the development of non-heat treatment Al alloys is becoming the hot topic.In addition,HPDC contains externally solidified crystals(ESCs),which are detrimental to the mechanical properties of castings.To achieve high strength and toughness of non-heat treatment die-casting Al-Si alloy,we used AlSi9Mn alloy as matrix with the introduction of Zr,Ti,Nb,and Ce.Their influences on ESCs and mechanical properties were systematically investigated through three-dimensional reconstruction and thermodynamic simulation.Our results reveal that the addition of Ti increased ESCs'size and porosity,while the introduction of Nb refined ESCs and decreased porosity.Meanwhile,large-sized Al_3(Zr,Ti)phases formed and degraded the mechanical properties.Subsequent introduction of Ce resulted in the poisoning effect and reduced mechanical properties.展开更多
The high-pressure electro-pneumatic servo valve(HESV)is a core element of the high-pressure pneumatic servo system.The annular clearance and the rounded corner of the spool-sleeve can cause the leakage at null positio...The high-pressure electro-pneumatic servo valve(HESV)is a core element of the high-pressure pneumatic servo system.The annular clearance and the rounded corner of the spool-sleeve can cause the leakage at null position,thereby affecting high-precision control and stability of the servo system.This paper investigates the effects of the clearance structure on leakage behavior at null position of the HESV.A numerical approach was employed to evaluate the effects,and then a mathematical model was established to obtain the variation law of leakage flow rate at null position.The results indicate that the leakage flow rate at null position varies linearly with supply pressure and rounded corner radius,and is nonlinear as a quadratic concave function with annular clearance.The leakage flow rate of the annular clearance and the rounded corner varies with the valve opening in an invariable−nonlinear−linear trend.A test rig system of leakage behavior at null position of the HESV was built to confirm the validity of the numerical model,which agrees well with the conducted experimental study.展开更多
High-pressure solenoid valve with high flow rate and high speed is a key component in an underwater driving system.However,traditional single spool pilot operated valve cannot meet the demands of both high flow rate a...High-pressure solenoid valve with high flow rate and high speed is a key component in an underwater driving system.However,traditional single spool pilot operated valve cannot meet the demands of both high flow rate and high speed simultaneously.A new structure for a high pressure solenoid valve is needed to meet the demand of the underwater driving system.A novel parallel-spool pilot operated high-pressure solenoid valve is proposed to overcome the drawback of the current single spool design.Mathematical models of the opening process and flow rate of the valve are established.Opening response time of the valve is subdivided into 4 parts to analyze the properties of the opening response.Corresponding formulas to solve 4 parts of the response time are derived.Key factors that influence the opening response time are analyzed.According to the mathematical model of the valve,a simulation of the opening process is carried out by MATLAB.Parameters are chosen based on theoretical analysis to design the test prototype of the new type of valve.Opening response time of the designed valve is tested by verifying response of the current in the coil and displacement of the main valve spool.The experimental results are in agreement with the simulated results,therefore the validity of the theoretical analysis is verified.Experimental opening response time of the valve is 48.3 ms at working pressure of 10 MPa.The flow capacity test shows that the largest effective area is 126 mm2 and the largest air flow rate is 2320 L/s.According to the result of the load driving test,the valve can meet the demands of the driving system.The proposed valve with parallel spools provides a new method for the design of a high-pressure valve with fast response and large flow rate.展开更多
To improve energy density,the transportation,storage,and operations of hydrogen,methane,and compressed air vehicles currently require high-pressure compression.High-pressure solenoid valve becomes the vital element to...To improve energy density,the transportation,storage,and operations of hydrogen,methane,and compressed air vehicles currently require high-pressure compression.High-pressure solenoid valve becomes the vital element to above system.In order to reduce leakage and aerodynamic force influence,a new type high-pressure solenoid valve was proposed.The simulation model which included electromagnetic model,aerodynamic force model was established by means of the nonlinear mathematic models.Using the software MATLAB/Simulink for simulation,the dynamic response characteristics of high-pressure pneumatic solenoid valve were obtained under different pulse width modulation(PWM)input control signals.Results show that,first of all,the new type of high-pressure solenoid valve can meet the switch requirement.Secondly,the opening movement and closing movement of the spool lags the PWM rising signal,and the coil current fluctuates significantly during the movement of the spool.Lastly,on/off status of high-pressure valve cannot be represented by the duty cycle.This research can be referred in the design of the high-pressure solenoid valve..展开更多
The safety valve is an important component to ensure the safe operation of lithium-ion batteries(LIBs).However,the effect of safety valve type on the thermal runaway(TR)and gas venting behavior of LIBs,as well as the ...The safety valve is an important component to ensure the safe operation of lithium-ion batteries(LIBs).However,the effect of safety valve type on the thermal runaway(TR)and gas venting behavior of LIBs,as well as the TR hazard severity of LIBs,are not known.In this paper,the TR and gas venting behavior of three 100 A h lithium iron phosphate(LFP)batteries with different safety valves are investigated under overheating.Compared to previous studies,the main contribution of this work is in studying and evaluating the effect of gas venting behavior and TR hazard severity of LFP batteries with three safety valve types.Two significant results are obtained:(Ⅰ)the safety valve type dominates over gas venting pressure of battery during safety venting,the maximum gas venting pressure of LFP batteries with a round safety valve is 3320 Pa,which is one order of magnitude higher than other batteries with oval or cavity safety valve;(Ⅱ)the LFP battery with oval safety valve has the lowest TR hazard as shown by the TR hazard assessment model based on gray-fuzzy analytic hierarchy process.This study reveals the effect of safety valve type on TR and gas venting,providing a clear direction for the safety valve design.展开更多
Purpose–The type 120 emergency valve is an essential braking component of railway freight trains,butcorresponding diaphragms consisting of natural rubber(NR)and chloroprene rubber(CR)exhibit insufficientaging resista...Purpose–The type 120 emergency valve is an essential braking component of railway freight trains,butcorresponding diaphragms consisting of natural rubber(NR)and chloroprene rubber(CR)exhibit insufficientaging resistance and low-temperature resistance,respectively.In order to develop type 120 emergency valverubber diaphragms with long-life and high-performance,low-temperatureresistant CR and NR were processed.Design/methodology/approach–The physical properties of the low-temperature-resistant CR and NRwere tested by low-temperature stretching,dynamic mechanical analysis,differential scanning calorimetryand thermogravimetric analysis.Single-valve and single-vehicle tests of type 120 emergency valves werecarried out for emergency diaphragms consisting of NR and CR.Findings–The low-temperature-resistant CR and NR exhibited excellent physical properties.The elasticityand low-temperature resistance of NR were superior to those of CR,whereas the mechanical properties of thetwo rubbers were similar in the temperature range of 0℃–150℃.The NR and CR emergency diaphragms metthe requirements of the single-valve test.In the low-temperature single-vehicle test,only the low-temperaturesensitivity test of the NR emergency diaphragm met the requirements.Originality/value–The innovation of this study is that it provides valuable data and experience for futuredevelopment of type 120 valve rubber diaphragms.展开更多
In this editorial,we comprehensively summarized the preoperative risk factors of early permanent pacemaker implantation after transcatheter aortic valve replacement(TAVR)among patients with severe aortic stenosis from...In this editorial,we comprehensively summarized the preoperative risk factors of early permanent pacemaker implantation after transcatheter aortic valve replacement(TAVR)among patients with severe aortic stenosis from several renowned clinical studies and focused on the primary prevention of managing the modifiable factors,e.g.,paroxysmal atrial fibrillation before the TAVR.展开更多
Background:Calcific aortic valve stenosis(CAVS)is one of the most challenging heart diseases in clinical with rapidly increasing prevalence.However,study of the mecha-nism and treatment of CAVS is hampered by the lack...Background:Calcific aortic valve stenosis(CAVS)is one of the most challenging heart diseases in clinical with rapidly increasing prevalence.However,study of the mecha-nism and treatment of CAVS is hampered by the lack of suitable,robust and efficient models that develop hemodynamically significant stenosis and typical calcium deposi-tion.Here,we aim to establish a mouse model to mimic the development and features of CAVS.Methods:The model was established via aortic valve wire injury(AVWI)combined with vitamin D subcutaneous injected in wild type C57/BL6 mice.Serial transthoracic echocardiography was applied to evaluate aortic jet peak velocity and mean gradi-ent.Histopathological specimens were collected and examined in respect of valve thickening,calcium deposition,collagen accumulation,osteogenic differentiation and inflammation.Results:Serial transthoracic echocardiography revealed that aortic jet peak velocity and mean gradient increased from 7 days post model establishment in a time depend-ent manner and tended to be stable at 28 days.Compared with the sham group,sim-ple AVWI or the vitamin D group,the hybrid model group showed typical pathological features of CAVS,including hemodynamic alterations,increased aortic valve thicken-ing,calcium deposition,collagen accumulation at 28 days.In addition,osteogenic dif-ferentiation,fibrosis and inflammation,which play critical roles in the development of CAVS,were observed in the hybrid model.Conclusions:We established a novel mouse model of CAVS that could be induced efficiently,robustly and economically,and without genetic intervention.It provides a fast track to explore the underlying mechanisms of CAVS and to identify more effec-tive pharmacological targets.展开更多
Heart valve diseases affect more than one hundred million people around the world,which are a serious cause of illness and mortality.[1]Among the valve diseases,mitral valve insufficiency ranks second in the list of v...Heart valve diseases affect more than one hundred million people around the world,which are a serious cause of illness and mortality.[1]Among the valve diseases,mitral valve insufficiency ranks second in the list of valve diseases requiring surgical repair in Europe.[2]Prosthetic valve replacement is the standard treatment in cases where repair is not sufficient for valve diseases.[3]Mechanical and bioprosthetic valves can be preferred for replacement,mechanical valves are more durable and require lifelong use of anticoagulants.The disadvantage of bioprosthetic valves is early degeneration,and infective reoperation is required due to the formation of endocarditis.[4-5]The risk of thromboembolism,lifetime anticoagulant use and complications related to anticoagulation remain disadvantages of valve surgery.[3]The most important complication requiring urgent intervention is valve dysfunction due to thrombosis.It usually occurs due to inappropriate use of the anticoagulants.[6]Surgical treatment is used for severe obstructions,such as thrombi larger than 10 mm.Thrombolytic therapy can be applied in small thrombi and in cases where surgical intervention is risky.展开更多
To improve the comprehensive mechanical properties of Al-Si-Cu alloy,it was treated by a high-pressure torsion process,and the effect of the deformation degree on the microstructure and properties of the Al-Si-Cu allo...To improve the comprehensive mechanical properties of Al-Si-Cu alloy,it was treated by a high-pressure torsion process,and the effect of the deformation degree on the microstructure and properties of the Al-Si-Cu alloy was studied.The results show that the reinforcements(β-Si andθ-CuAl_(2)phases)of the Al-Si-Cu alloy are dispersed in theα-Al matrix phase with finer phase size after the treatment.The processed samples exhibit grain sizes in the submicron or even nanometer range,which effectively improves the mechanical properties of the material.The hardness and strength of the deformed alloy are both significantly raised to 268 HV and 390.04 MPa by 10 turns HPT process,and the fracture morphology shows that the material gradually transits from brittle to plastic before and after deformation.The elements interdiffusion at the interface between the phases has also been effectively enhanced.In addition,it is found that the severe plastic deformation at room temperature induces a ternary eutectic reaction,resulting in the formation of ternary Al+Si+CuAl_(2)eutectic.展开更多
Aortic valve calcification disease (CAVD) is the most prevalent degenerative valve disease in humans, leading to significant morbidity and mortality. Despite its common occurrence, our understanding of the underlying ...Aortic valve calcification disease (CAVD) is the most prevalent degenerative valve disease in humans, leading to significant morbidity and mortality. Despite its common occurrence, our understanding of the underlying mechanisms remains incomplete, and available treatment options are limited and risky. A more comprehensive understanding of the biology of CAVD is essential to identify new therapeutic strategies. Animal models have played a crucial role in advancing our knowledge of CAVD and exploring potential treatments. However, these models have inherent limitations as they cannot fully replicate the complex physiological mechanisms of human CAVD. In this review, we examine various CAVD models ranging from pigs to mice, highlighting the unique characteristics of each model to enhance our understanding of CAVD. While these models offer valuable insights, they also have limitations and shortcomings. We propose that the guide wire model shows promise for future CAVD research, and streamlining the methodology could enhance our understanding and expand the research scope in this field.展开更多
Repairs of corroded high-pressure pipelines are essential for fluids transportation under high pressure.One of the methods used in their repairs is the use of layered composites.The composite used must have the necess...Repairs of corroded high-pressure pipelines are essential for fluids transportation under high pressure.One of the methods used in their repairs is the use of layered composites.The composite used must have the necessary strength.Therefore,the experiments and analytical solutions presented in this paper are performed according to the relevant standards and codes,including ASME PCC-2,ASME B31.8S,ASME B31.4,ISO 24817 and ASME B31.G.In addition,the experimental tests are replicated numerically using the finite element method.Setting the strain gauges at different distances from the defect location,can reduce the nonlinear effects,deformation,and fluctuations due to the high pressure.The direct relationship between the depth of an axial defect and the stress concentration is observed at the inner side edges of the defect.Composite reparation reduces the non-linearities related to the sharp variation of the geometry and a more reliable numerical simulation could be performed.展开更多
Objective The standardization of warfarin anticoagulant therapy is the key to lifelong treatment for patients after heart valve replacement.The present study explored the possible risk factors for anxiety and depressi...Objective The standardization of warfarin anticoagulant therapy is the key to lifelong treatment for patients after heart valve replacement.The present study explored the possible risk factors for anxiety and depression during the coronavirus disease 2019(COVID-19)pandemic and analyzed the influence of psychological state on medication safety.Methods Eligible patients received a web-based questionnaire survey via the Wenjuanxing platform during outpatient visits.Depression was evaluated by the Self-Rating Depression Scale(SDS).Anxiety was evaluated by the Self-Rating Anxiety Scale(SAS).Medication adherence was evaluated by the Morisky scale.Results A total of 309 patients(aged 52.2±11.4 years)were included in the present study.The SDS score of all included patients was 36.9±9.4 points,of which 11(3.6%)patients were diagnosed as having depression.The SAS score of all included patients was 43.1±9.3 points,of which 71(23%)patients were diagnosed as having anxiety.Seven patients(2.3%)had both anxiety and depression.Logistic regression analysis revealed that only monthly income was an independent influencing factor for depression.Regarding anxiety,patients who underwent repeated operations had a 2.264-fold greater risk,and patients who received combination medication had a 2.140-fold greater risk.More bleeding events and coagulation disorders could be observed in patients with anxiety,depression or both.When anxiety occurred,patients showed worse medication adherence.However,depression had no significant effect on medication adherence.Conclusion During the COVID-19 pandemic,the detection rate of mental illnesses such as anxiety and depression was high,which seriously affected the medication safety of warfarin.Analysis of its influencing factors will provide a reference for further standardized regulation of warfarin anticoagulant therapy after valve replacement.展开更多
Since the advent of transcatheter aortic valve replacement(TAVR)in 2002,it has now become the default interventional strategy for symptomatic patients presenting with severe aortic stenosis,particularly in intermediat...Since the advent of transcatheter aortic valve replacement(TAVR)in 2002,it has now become the default interventional strategy for symptomatic patients presenting with severe aortic stenosis,particularly in intermediate to highsurgical risk patients.In 2019,the United States Food and Drug Administration approved TAVR in low-risk patients based on two randomized trials.However,these breakthrough trials excluded patients with certain unfavorable anatomies and odd profiles.While currently there is no randomized study of TAVR in young patients,it may be preferred by the young population given the benefits of early discharge,shorter hospital stay,and expedite recovery.Nonetheless,it is important to ruminate various factors including lifetime expectancy,risk of pacemaker implantation,and the need for future valve or coronary interventions in young cohorts before considering TAVR in these patients.Furthermore,the data on long-term durability(>10 years)of TAVR is still unknown given most of the procedures were initially performed in the high or prohibitive surgical risk population.Thus,this editorial aims to highlight the importance of considering an individualized approach in young patients with consideration of various factors including lifetime expectancy while choosing TAVR against surgical aortic valve replacement.展开更多
The liquid-cooled battery energy sto rage system(LCBESS) has gained significant attention due to its superior thermal management capacity.However,liquid-cooled battery pack(LCBP) usually has a high sealing level above...The liquid-cooled battery energy sto rage system(LCBESS) has gained significant attention due to its superior thermal management capacity.However,liquid-cooled battery pack(LCBP) usually has a high sealing level above IP65,which can trap flammable and explosive gases from battery thermal runaway and cause explosions.This poses serious safety risks and challenges for LCBESS.In this study,we tested overcharged battery inside a commercial LCBP and found that the conventionally mechanical pressure relief valve(PRV) on the LCBP had a delayed response and low-pressure relief efficiency.A realistic 20-foot model of an energy storage cabin was constructed using the Flacs finite element simulation software.Comparative studies were conducted to evaluate the pressure relief efficiency and the influence on neighboring battery packs in case of internal explosions,considering different sizes and installation positions of the PRV.Here,a newly developed electric-controlled PRV integrated with battery fault detection is introduced,capable of starting within 50 ms of the battery safety valve opening.Furthermore,the PRV was integrated with the battery management system and changed the battery charging and discharging strategy after the PRV was opened.Experimental tests confirmed the efficacy of this method in preventing explosions.This paper addresses the safety concerns associated with LCBPs and proposes an effective solution for explosion relief.展开更多
This study explores the implementation of computed tomography(CT)reconstruction and simulation techniques for patient-specific valves,aiming to dissect the mechanical attributes of calcified valves within transcathete...This study explores the implementation of computed tomography(CT)reconstruction and simulation techniques for patient-specific valves,aiming to dissect the mechanical attributes of calcified valves within transcatheter heart valve replacement(TAVR)procedures.In order to facilitate this exploration,it derives pertinent formulas for 3D multi-material isogeometric hyperelastic analysis based on Hounsfield unit(HU)values,thereby unlocking foundational capabilities for isogeometric analysis in calcified aortic valves.A series of uniaxial and biaxial tensile tests is executed to obtain an accurate constitutive model for calcified active valves.To mitigate discretization errors,methodologies for reconstructing volumetric parametric models,integrating both geometric and material attributes,are introduced.Applying these analytical formulas,constitutive models,and precise analytical models to isogeometric analyses of calcified valves,the research ascertains their close alignment with experimental results through the close fit in displacement-stress curves,compellingly validating the accuracy and reliability of the method.This study presents a step-by-step approach to analyzing themechanical characteristics of patient-specific valves obtained fromCT images,holding significant clinical implications and assisting in the selection of treatment strategies and surgical intervention approaches in TAVR procedures.展开更多
Background: Tuberculous endocarditis is a rare but serious complication of heart valve replacement surgery. We report the case of a 24-year-old patient, who presented with tuberculous endocarditis after mechanical mit...Background: Tuberculous endocarditis is a rare but serious complication of heart valve replacement surgery. We report the case of a 24-year-old patient, who presented with tuberculous endocarditis after mechanical mitral valve replacement, with a favorable clinical course following anti-tuberculosis treatment. Case Presentation: We report a 24-year-old male patient, admitted to the cardiac surgery department of the Fann Hospital (Dakar, Senegal), for the management of severe mixed (rheumatic and endocarditic) mitral insufficiency with associated tricuspid insufficiency. He had a history of recurrent angina and polyarthralgia in childhood, was hospitalized several times for refractory global cardiac decompensation, and for a suspected infective endocarditis a month before his admission. On admission, the clinical examination revealed signs suggestive of mitral and tricuspid insufficiency. Transthoracic echocardiography revealed severe post-endocarditic mitral insufficiency with A3 amputation, highly mobile 15 mm vegetations on the free edge of the large valve, moderate tricuspid insufficiency, and severe pulmonary artery hypertension. Mechanical mitral valve replacement and tricuspid valve annuloplasty using autologous pericardial strip were performed via median sternotomy. After ten days, the patient presented with global cardiac decompensation associated with a clinico-biological infectious syndrome, and tans-oesophageal echography revealed an abscess at the sinotubular junction, communicating with the aorta. A thoraco-abdomino-pelvic CT scan was done, which revealed a bilateral alveolar-interstitial syndrome with mediastinal lymphadenopathy. Anti-tuberculosis treatment with RHZE was initiated for 06 months. The clinical course was favorable. Conclusion: Tuberculous endocarditis in prostheses is a serious complication of heart valve replacement surgery, which may evolve favorably under medical treatment.展开更多
In situ regeneration is a promising strategy for constructing tissue engineering heart valves(TEHVs).Currently,the decellularized heart valve(DHV)is extensively employed as a TEHV scaffold.Nevertheless,DHV exhibits li...In situ regeneration is a promising strategy for constructing tissue engineering heart valves(TEHVs).Currently,the decellularized heart valve(DHV)is extensively employed as a TEHV scaffold.Nevertheless,DHV exhibits limited blood compatibility and notable difficulties in endothelialization,resulting in thrombosis and graft failure.The red blood cell membrane(RBCM)exhibits excellent biocompatibility and prolonged circulation stability and is extensively applied in the camouflage of nanoparticles for drug delivery;however,there is no report on its application for large-scale modification of decellularized extracellular matrix(ECM).For the first time,we utilized a layer-by-layer assembling strategy to immobilize RBCM on the surface of DHV and construct an innovative TEHV scaffold.Our findings demonstrated that the scaffold significantly improved the hemocompatibility of DHV by effectively preventing plasma protein adsorption,activated platelet adhesion,and erythrocyte aggregation,and induced macrophage polarization toward the M2 phenotype in vitro.Moreover,RBCM modification significantly enhanced the mechanical properties and enzymatic stability of DHV.The rat models of subcutaneous embedding and abdominal aorta implantation showed that the scaffold regulated the polarization of macrophages into the anti-inflammatory and pro-modeling M2 phenotype and promoted endothelialization and ECM remodeling in the early stage without thrombosis and calcification.The novel TEHV exhibits excellent performance and can overcome the limitations of commonly used clinical prostheses.展开更多
Altwijri and Alsirhy reported a case of uveitis-glaucoma-hyphema syndrome after an Ahmed glaucoma valve implantation surgery in an advanced primary open-angle glaucoma patient,being the first ever recorded of its kind...Altwijri and Alsirhy reported a case of uveitis-glaucoma-hyphema syndrome after an Ahmed glaucoma valve implantation surgery in an advanced primary open-angle glaucoma patient,being the first ever recorded of its kind.The author describes the position of the tube as the origin of the anterior chamber inflam-mation and hyphema,which resolved shortly after shortening and relocating it.This publication emphasizes the importance of precise implant positioning and close-up patient follow-up after glaucoma filtration surgery as an important standard for healthcare providers.展开更多
BACKGROUND Transcatheter aortic valve replacement(TAVR)is a revolutionary procedure for severe aortic stenosis.The coexistence of chronic kidney disease(CKD)and TAVR introduces a challenge that significantly impacts p...BACKGROUND Transcatheter aortic valve replacement(TAVR)is a revolutionary procedure for severe aortic stenosis.The coexistence of chronic kidney disease(CKD)and TAVR introduces a challenge that significantly impacts patient outcomes.AIM To define readmission rates,predictors,and causes after TAVR procedure in CKD stage 1-4 patients.METHODS We used the national readmission database 2018 and 2020 to look into readmission rates,causes and predictors after TAVR procedure in patients with CKD stage 1-4.RESULTS Out of 24758 who underwent TAVR and had CKD,7892(32.4%)patients were readmitted within 90 days,and had higher adjusted odds of being females(adjusted odds ratio:1.17,95%CI:1.02-1.31,P=0.02)with longer length of hospital stay>6 days,and more comorbidities including but not limited to diabetes mellitus,anemia,and congestive heart failure(CHF).CONCLUSION Most common causes of readmission included CHF(18.0%),sepsis,and complete atrioventricular block.Controlling readmission predictors with very close followup is warranted to prevent such high rate of readmission.展开更多
基金financially supported by the National Natural Science Foundation of China(Nos.52175284 and 52474396)the National Key Research and Development Program of China(No.2022YFB3404201)。
文摘High pressure die casting(HPDC)AlSi10Mn Mg alloy castings are widely used in the automobile industry.Mg can optimize the mechanical properties of castings through heat treatment,while the release of thermal stress arouses the deformation of large integrated die-castings.Herein,the development of non-heat treatment Al alloys is becoming the hot topic.In addition,HPDC contains externally solidified crystals(ESCs),which are detrimental to the mechanical properties of castings.To achieve high strength and toughness of non-heat treatment die-casting Al-Si alloy,we used AlSi9Mn alloy as matrix with the introduction of Zr,Ti,Nb,and Ce.Their influences on ESCs and mechanical properties were systematically investigated through three-dimensional reconstruction and thermodynamic simulation.Our results reveal that the addition of Ti increased ESCs'size and porosity,while the introduction of Nb refined ESCs and decreased porosity.Meanwhile,large-sized Al_3(Zr,Ti)phases formed and degraded the mechanical properties.Subsequent introduction of Ce resulted in the poisoning effect and reduced mechanical properties.
基金Project(51705164)supported by the National Natural Science Foundation of China。
文摘The high-pressure electro-pneumatic servo valve(HESV)is a core element of the high-pressure pneumatic servo system.The annular clearance and the rounded corner of the spool-sleeve can cause the leakage at null position,thereby affecting high-precision control and stability of the servo system.This paper investigates the effects of the clearance structure on leakage behavior at null position of the HESV.A numerical approach was employed to evaluate the effects,and then a mathematical model was established to obtain the variation law of leakage flow rate at null position.The results indicate that the leakage flow rate at null position varies linearly with supply pressure and rounded corner radius,and is nonlinear as a quadratic concave function with annular clearance.The leakage flow rate of the annular clearance and the rounded corner varies with the valve opening in an invariable−nonlinear−linear trend.A test rig system of leakage behavior at null position of the HESV was built to confirm the validity of the numerical model,which agrees well with the conducted experimental study.
文摘High-pressure solenoid valve with high flow rate and high speed is a key component in an underwater driving system.However,traditional single spool pilot operated valve cannot meet the demands of both high flow rate and high speed simultaneously.A new structure for a high pressure solenoid valve is needed to meet the demand of the underwater driving system.A novel parallel-spool pilot operated high-pressure solenoid valve is proposed to overcome the drawback of the current single spool design.Mathematical models of the opening process and flow rate of the valve are established.Opening response time of the valve is subdivided into 4 parts to analyze the properties of the opening response.Corresponding formulas to solve 4 parts of the response time are derived.Key factors that influence the opening response time are analyzed.According to the mathematical model of the valve,a simulation of the opening process is carried out by MATLAB.Parameters are chosen based on theoretical analysis to design the test prototype of the new type of valve.Opening response time of the designed valve is tested by verifying response of the current in the coil and displacement of the main valve spool.The experimental results are in agreement with the simulated results,therefore the validity of the theoretical analysis is verified.Experimental opening response time of the valve is 48.3 ms at working pressure of 10 MPa.The flow capacity test shows that the largest effective area is 126 mm2 and the largest air flow rate is 2320 L/s.According to the result of the load driving test,the valve can meet the demands of the driving system.The proposed valve with parallel spools provides a new method for the design of a high-pressure valve with fast response and large flow rate.
基金The research work presented in this paper is financially supported by a grant(NJZZ18139)from the scientific research project of Universities in Inner Mongoliaa grant(2018BS05003)from the Natural Science Foundation of Inner Mongoliaa grant(2017QDL-B07)from Inner Mongolia University of Science and Technology Innovation Fund Project.
文摘To improve energy density,the transportation,storage,and operations of hydrogen,methane,and compressed air vehicles currently require high-pressure compression.High-pressure solenoid valve becomes the vital element to above system.In order to reduce leakage and aerodynamic force influence,a new type high-pressure solenoid valve was proposed.The simulation model which included electromagnetic model,aerodynamic force model was established by means of the nonlinear mathematic models.Using the software MATLAB/Simulink for simulation,the dynamic response characteristics of high-pressure pneumatic solenoid valve were obtained under different pulse width modulation(PWM)input control signals.Results show that,first of all,the new type of high-pressure solenoid valve can meet the switch requirement.Secondly,the opening movement and closing movement of the spool lags the PWM rising signal,and the coil current fluctuates significantly during the movement of the spool.Lastly,on/off status of high-pressure valve cannot be represented by the duty cycle.This research can be referred in the design of the high-pressure solenoid valve..
基金supported by the National Key R&D Program of China(No.2021YFB2402001)the Postgraduate Innovation and Entrepreneurship Practice Project of Anhui Province(No.2022cxcysj013)+2 种基金the China Postdoctoral Science Foundation(No.2022T150615)the Fundamental Research Funds for the Central Universities(No.WK5290000002)supported by Youth Innovation Promotion Association CAS(No.Y201768)。
文摘The safety valve is an important component to ensure the safe operation of lithium-ion batteries(LIBs).However,the effect of safety valve type on the thermal runaway(TR)and gas venting behavior of LIBs,as well as the TR hazard severity of LIBs,are not known.In this paper,the TR and gas venting behavior of three 100 A h lithium iron phosphate(LFP)batteries with different safety valves are investigated under overheating.Compared to previous studies,the main contribution of this work is in studying and evaluating the effect of gas venting behavior and TR hazard severity of LFP batteries with three safety valve types.Two significant results are obtained:(Ⅰ)the safety valve type dominates over gas venting pressure of battery during safety venting,the maximum gas venting pressure of LFP batteries with a round safety valve is 3320 Pa,which is one order of magnitude higher than other batteries with oval or cavity safety valve;(Ⅱ)the LFP battery with oval safety valve has the lowest TR hazard as shown by the TR hazard assessment model based on gray-fuzzy analytic hierarchy process.This study reveals the effect of safety valve type on TR and gas venting,providing a clear direction for the safety valve design.
基金funded by the Science and Technology Research and Development Plan of the China State Railway Group Company Limited(No.N2023J053).
文摘Purpose–The type 120 emergency valve is an essential braking component of railway freight trains,butcorresponding diaphragms consisting of natural rubber(NR)and chloroprene rubber(CR)exhibit insufficientaging resistance and low-temperature resistance,respectively.In order to develop type 120 emergency valverubber diaphragms with long-life and high-performance,low-temperatureresistant CR and NR were processed.Design/methodology/approach–The physical properties of the low-temperature-resistant CR and NRwere tested by low-temperature stretching,dynamic mechanical analysis,differential scanning calorimetryand thermogravimetric analysis.Single-valve and single-vehicle tests of type 120 emergency valves werecarried out for emergency diaphragms consisting of NR and CR.Findings–The low-temperature-resistant CR and NR exhibited excellent physical properties.The elasticityand low-temperature resistance of NR were superior to those of CR,whereas the mechanical properties of thetwo rubbers were similar in the temperature range of 0℃–150℃.The NR and CR emergency diaphragms metthe requirements of the single-valve test.In the low-temperature single-vehicle test,only the low-temperaturesensitivity test of the NR emergency diaphragm met the requirements.Originality/value–The innovation of this study is that it provides valuable data and experience for futuredevelopment of type 120 valve rubber diaphragms.
文摘In this editorial,we comprehensively summarized the preoperative risk factors of early permanent pacemaker implantation after transcatheter aortic valve replacement(TAVR)among patients with severe aortic stenosis from several renowned clinical studies and focused on the primary prevention of managing the modifiable factors,e.g.,paroxysmal atrial fibrillation before the TAVR.
基金National Natural Science Foundation of China,Grant/Award Number:81770252,82030014,82271606 and U22A20267Binjiang Institute of Zhejiang University,Grant/Award Number:ZY202205SMKY001Key Program of Major Science and Technology Projects in Zhejiang Province,Grant/Award Number:2021C03097 and 2022C03063。
文摘Background:Calcific aortic valve stenosis(CAVS)is one of the most challenging heart diseases in clinical with rapidly increasing prevalence.However,study of the mecha-nism and treatment of CAVS is hampered by the lack of suitable,robust and efficient models that develop hemodynamically significant stenosis and typical calcium deposi-tion.Here,we aim to establish a mouse model to mimic the development and features of CAVS.Methods:The model was established via aortic valve wire injury(AVWI)combined with vitamin D subcutaneous injected in wild type C57/BL6 mice.Serial transthoracic echocardiography was applied to evaluate aortic jet peak velocity and mean gradi-ent.Histopathological specimens were collected and examined in respect of valve thickening,calcium deposition,collagen accumulation,osteogenic differentiation and inflammation.Results:Serial transthoracic echocardiography revealed that aortic jet peak velocity and mean gradient increased from 7 days post model establishment in a time depend-ent manner and tended to be stable at 28 days.Compared with the sham group,sim-ple AVWI or the vitamin D group,the hybrid model group showed typical pathological features of CAVS,including hemodynamic alterations,increased aortic valve thicken-ing,calcium deposition,collagen accumulation at 28 days.In addition,osteogenic dif-ferentiation,fibrosis and inflammation,which play critical roles in the development of CAVS,were observed in the hybrid model.Conclusions:We established a novel mouse model of CAVS that could be induced efficiently,robustly and economically,and without genetic intervention.It provides a fast track to explore the underlying mechanisms of CAVS and to identify more effec-tive pharmacological targets.
文摘Heart valve diseases affect more than one hundred million people around the world,which are a serious cause of illness and mortality.[1]Among the valve diseases,mitral valve insufficiency ranks second in the list of valve diseases requiring surgical repair in Europe.[2]Prosthetic valve replacement is the standard treatment in cases where repair is not sufficient for valve diseases.[3]Mechanical and bioprosthetic valves can be preferred for replacement,mechanical valves are more durable and require lifelong use of anticoagulants.The disadvantage of bioprosthetic valves is early degeneration,and infective reoperation is required due to the formation of endocarditis.[4-5]The risk of thromboembolism,lifetime anticoagulant use and complications related to anticoagulation remain disadvantages of valve surgery.[3]The most important complication requiring urgent intervention is valve dysfunction due to thrombosis.It usually occurs due to inappropriate use of the anticoagulants.[6]Surgical treatment is used for severe obstructions,such as thrombi larger than 10 mm.Thrombolytic therapy can be applied in small thrombi and in cases where surgical intervention is risky.
基金Funded by the National Natural Science Foundation of China(No.51905215)Postgraduate Research&Practice Innovation Program of Jiangsu Province(No.SJCX23_1233)+1 种基金Major Scientific and Technological Innovation Project of Shandong Province of China(No.2019JZZY020111)the National College Students Innovation and Entrepreneurship Training Program of China(No.CX2022415)。
文摘To improve the comprehensive mechanical properties of Al-Si-Cu alloy,it was treated by a high-pressure torsion process,and the effect of the deformation degree on the microstructure and properties of the Al-Si-Cu alloy was studied.The results show that the reinforcements(β-Si andθ-CuAl_(2)phases)of the Al-Si-Cu alloy are dispersed in theα-Al matrix phase with finer phase size after the treatment.The processed samples exhibit grain sizes in the submicron or even nanometer range,which effectively improves the mechanical properties of the material.The hardness and strength of the deformed alloy are both significantly raised to 268 HV and 390.04 MPa by 10 turns HPT process,and the fracture morphology shows that the material gradually transits from brittle to plastic before and after deformation.The elements interdiffusion at the interface between the phases has also been effectively enhanced.In addition,it is found that the severe plastic deformation at room temperature induces a ternary eutectic reaction,resulting in the formation of ternary Al+Si+CuAl_(2)eutectic.
文摘Aortic valve calcification disease (CAVD) is the most prevalent degenerative valve disease in humans, leading to significant morbidity and mortality. Despite its common occurrence, our understanding of the underlying mechanisms remains incomplete, and available treatment options are limited and risky. A more comprehensive understanding of the biology of CAVD is essential to identify new therapeutic strategies. Animal models have played a crucial role in advancing our knowledge of CAVD and exploring potential treatments. However, these models have inherent limitations as they cannot fully replicate the complex physiological mechanisms of human CAVD. In this review, we examine various CAVD models ranging from pigs to mice, highlighting the unique characteristics of each model to enhance our understanding of CAVD. While these models offer valuable insights, they also have limitations and shortcomings. We propose that the guide wire model shows promise for future CAVD research, and streamlining the methodology could enhance our understanding and expand the research scope in this field.
文摘Repairs of corroded high-pressure pipelines are essential for fluids transportation under high pressure.One of the methods used in their repairs is the use of layered composites.The composite used must have the necessary strength.Therefore,the experiments and analytical solutions presented in this paper are performed according to the relevant standards and codes,including ASME PCC-2,ASME B31.8S,ASME B31.4,ISO 24817 and ASME B31.G.In addition,the experimental tests are replicated numerically using the finite element method.Setting the strain gauges at different distances from the defect location,can reduce the nonlinear effects,deformation,and fluctuations due to the high pressure.The direct relationship between the depth of an axial defect and the stress concentration is observed at the inner side edges of the defect.Composite reparation reduces the non-linearities related to the sharp variation of the geometry and a more reliable numerical simulation could be performed.
文摘Objective The standardization of warfarin anticoagulant therapy is the key to lifelong treatment for patients after heart valve replacement.The present study explored the possible risk factors for anxiety and depression during the coronavirus disease 2019(COVID-19)pandemic and analyzed the influence of psychological state on medication safety.Methods Eligible patients received a web-based questionnaire survey via the Wenjuanxing platform during outpatient visits.Depression was evaluated by the Self-Rating Depression Scale(SDS).Anxiety was evaluated by the Self-Rating Anxiety Scale(SAS).Medication adherence was evaluated by the Morisky scale.Results A total of 309 patients(aged 52.2±11.4 years)were included in the present study.The SDS score of all included patients was 36.9±9.4 points,of which 11(3.6%)patients were diagnosed as having depression.The SAS score of all included patients was 43.1±9.3 points,of which 71(23%)patients were diagnosed as having anxiety.Seven patients(2.3%)had both anxiety and depression.Logistic regression analysis revealed that only monthly income was an independent influencing factor for depression.Regarding anxiety,patients who underwent repeated operations had a 2.264-fold greater risk,and patients who received combination medication had a 2.140-fold greater risk.More bleeding events and coagulation disorders could be observed in patients with anxiety,depression or both.When anxiety occurred,patients showed worse medication adherence.However,depression had no significant effect on medication adherence.Conclusion During the COVID-19 pandemic,the detection rate of mental illnesses such as anxiety and depression was high,which seriously affected the medication safety of warfarin.Analysis of its influencing factors will provide a reference for further standardized regulation of warfarin anticoagulant therapy after valve replacement.
文摘Since the advent of transcatheter aortic valve replacement(TAVR)in 2002,it has now become the default interventional strategy for symptomatic patients presenting with severe aortic stenosis,particularly in intermediate to highsurgical risk patients.In 2019,the United States Food and Drug Administration approved TAVR in low-risk patients based on two randomized trials.However,these breakthrough trials excluded patients with certain unfavorable anatomies and odd profiles.While currently there is no randomized study of TAVR in young patients,it may be preferred by the young population given the benefits of early discharge,shorter hospital stay,and expedite recovery.Nonetheless,it is important to ruminate various factors including lifetime expectancy,risk of pacemaker implantation,and the need for future valve or coronary interventions in young cohorts before considering TAVR in these patients.Furthermore,the data on long-term durability(>10 years)of TAVR is still unknown given most of the procedures were initially performed in the high or prohibitive surgical risk population.Thus,this editorial aims to highlight the importance of considering an individualized approach in young patients with consideration of various factors including lifetime expectancy while choosing TAVR against surgical aortic valve replacement.
基金sponsored by the Science and Technology Program of State Grid Corporation of China(4000-202355090A-1-1ZN)。
文摘The liquid-cooled battery energy sto rage system(LCBESS) has gained significant attention due to its superior thermal management capacity.However,liquid-cooled battery pack(LCBP) usually has a high sealing level above IP65,which can trap flammable and explosive gases from battery thermal runaway and cause explosions.This poses serious safety risks and challenges for LCBESS.In this study,we tested overcharged battery inside a commercial LCBP and found that the conventionally mechanical pressure relief valve(PRV) on the LCBP had a delayed response and low-pressure relief efficiency.A realistic 20-foot model of an energy storage cabin was constructed using the Flacs finite element simulation software.Comparative studies were conducted to evaluate the pressure relief efficiency and the influence on neighboring battery packs in case of internal explosions,considering different sizes and installation positions of the PRV.Here,a newly developed electric-controlled PRV integrated with battery fault detection is introduced,capable of starting within 50 ms of the battery safety valve opening.Furthermore,the PRV was integrated with the battery management system and changed the battery charging and discharging strategy after the PRV was opened.Experimental tests confirmed the efficacy of this method in preventing explosions.This paper addresses the safety concerns associated with LCBPs and proposes an effective solution for explosion relief.
基金supported by the Natural Science Foundation of China(Project Nos.52075340 and 61972011)the Shanghai Special Research Project on Aging Population and Maternal and Child Health(Project No.2020YJZX0106).
文摘This study explores the implementation of computed tomography(CT)reconstruction and simulation techniques for patient-specific valves,aiming to dissect the mechanical attributes of calcified valves within transcatheter heart valve replacement(TAVR)procedures.In order to facilitate this exploration,it derives pertinent formulas for 3D multi-material isogeometric hyperelastic analysis based on Hounsfield unit(HU)values,thereby unlocking foundational capabilities for isogeometric analysis in calcified aortic valves.A series of uniaxial and biaxial tensile tests is executed to obtain an accurate constitutive model for calcified active valves.To mitigate discretization errors,methodologies for reconstructing volumetric parametric models,integrating both geometric and material attributes,are introduced.Applying these analytical formulas,constitutive models,and precise analytical models to isogeometric analyses of calcified valves,the research ascertains their close alignment with experimental results through the close fit in displacement-stress curves,compellingly validating the accuracy and reliability of the method.This study presents a step-by-step approach to analyzing themechanical characteristics of patient-specific valves obtained fromCT images,holding significant clinical implications and assisting in the selection of treatment strategies and surgical intervention approaches in TAVR procedures.
文摘Background: Tuberculous endocarditis is a rare but serious complication of heart valve replacement surgery. We report the case of a 24-year-old patient, who presented with tuberculous endocarditis after mechanical mitral valve replacement, with a favorable clinical course following anti-tuberculosis treatment. Case Presentation: We report a 24-year-old male patient, admitted to the cardiac surgery department of the Fann Hospital (Dakar, Senegal), for the management of severe mixed (rheumatic and endocarditic) mitral insufficiency with associated tricuspid insufficiency. He had a history of recurrent angina and polyarthralgia in childhood, was hospitalized several times for refractory global cardiac decompensation, and for a suspected infective endocarditis a month before his admission. On admission, the clinical examination revealed signs suggestive of mitral and tricuspid insufficiency. Transthoracic echocardiography revealed severe post-endocarditic mitral insufficiency with A3 amputation, highly mobile 15 mm vegetations on the free edge of the large valve, moderate tricuspid insufficiency, and severe pulmonary artery hypertension. Mechanical mitral valve replacement and tricuspid valve annuloplasty using autologous pericardial strip were performed via median sternotomy. After ten days, the patient presented with global cardiac decompensation associated with a clinico-biological infectious syndrome, and tans-oesophageal echography revealed an abscess at the sinotubular junction, communicating with the aorta. A thoraco-abdomino-pelvic CT scan was done, which revealed a bilateral alveolar-interstitial syndrome with mediastinal lymphadenopathy. Anti-tuberculosis treatment with RHZE was initiated for 06 months. The clinical course was favorable. Conclusion: Tuberculous endocarditis in prostheses is a serious complication of heart valve replacement surgery, which may evolve favorably under medical treatment.
基金supported by the National Key Research and Development Program of China(2021YFA1101900 and 2023YFB3810100)the National Natural Science Foundation of China(82270381 and 81930052)the Major Science and Technology Special Plan Project of Yunnan Province(202302AA310045).
文摘In situ regeneration is a promising strategy for constructing tissue engineering heart valves(TEHVs).Currently,the decellularized heart valve(DHV)is extensively employed as a TEHV scaffold.Nevertheless,DHV exhibits limited blood compatibility and notable difficulties in endothelialization,resulting in thrombosis and graft failure.The red blood cell membrane(RBCM)exhibits excellent biocompatibility and prolonged circulation stability and is extensively applied in the camouflage of nanoparticles for drug delivery;however,there is no report on its application for large-scale modification of decellularized extracellular matrix(ECM).For the first time,we utilized a layer-by-layer assembling strategy to immobilize RBCM on the surface of DHV and construct an innovative TEHV scaffold.Our findings demonstrated that the scaffold significantly improved the hemocompatibility of DHV by effectively preventing plasma protein adsorption,activated platelet adhesion,and erythrocyte aggregation,and induced macrophage polarization toward the M2 phenotype in vitro.Moreover,RBCM modification significantly enhanced the mechanical properties and enzymatic stability of DHV.The rat models of subcutaneous embedding and abdominal aorta implantation showed that the scaffold regulated the polarization of macrophages into the anti-inflammatory and pro-modeling M2 phenotype and promoted endothelialization and ECM remodeling in the early stage without thrombosis and calcification.The novel TEHV exhibits excellent performance and can overcome the limitations of commonly used clinical prostheses.
文摘Altwijri and Alsirhy reported a case of uveitis-glaucoma-hyphema syndrome after an Ahmed glaucoma valve implantation surgery in an advanced primary open-angle glaucoma patient,being the first ever recorded of its kind.The author describes the position of the tube as the origin of the anterior chamber inflam-mation and hyphema,which resolved shortly after shortening and relocating it.This publication emphasizes the importance of precise implant positioning and close-up patient follow-up after glaucoma filtration surgery as an important standard for healthcare providers.
文摘BACKGROUND Transcatheter aortic valve replacement(TAVR)is a revolutionary procedure for severe aortic stenosis.The coexistence of chronic kidney disease(CKD)and TAVR introduces a challenge that significantly impacts patient outcomes.AIM To define readmission rates,predictors,and causes after TAVR procedure in CKD stage 1-4 patients.METHODS We used the national readmission database 2018 and 2020 to look into readmission rates,causes and predictors after TAVR procedure in patients with CKD stage 1-4.RESULTS Out of 24758 who underwent TAVR and had CKD,7892(32.4%)patients were readmitted within 90 days,and had higher adjusted odds of being females(adjusted odds ratio:1.17,95%CI:1.02-1.31,P=0.02)with longer length of hospital stay>6 days,and more comorbidities including but not limited to diabetes mellitus,anemia,and congestive heart failure(CHF).CONCLUSION Most common causes of readmission included CHF(18.0%),sepsis,and complete atrioventricular block.Controlling readmission predictors with very close followup is warranted to prevent such high rate of readmission.