To thoroughly study the extinguishing effect of a high-pressure water mist fire extinguishing system when a transformer fire occurs,a 3D experimental model of a transformer is established in this work by employing Fir...To thoroughly study the extinguishing effect of a high-pressure water mist fire extinguishing system when a transformer fire occurs,a 3D experimental model of a transformer is established in this work by employing Fire Dynamics Simulator(FDS)software.More specifically,by setting different parameters,the process of the highpressure water mist fire extinguishing system with the presence of both diverse ambient temperatures and water mist sprinkler laying conditions is simulated.In addition,the fire extinguishing effect of the employed high-pressure water mist system with the implementation of different strategies is systematically analyzed.The extracted results show that a fire source farther away fromthe centerline leads to a lower local temperature distribution.In addition,as the ambient temperature increases,the temperature above the fire source decreases,while the temperature and the concentrationof theupperflue gas layer bothdecrease.Interestingly,after thehigh-pressurewatermist sprinkler begins to operate,both the temperature distribution above the fire source and the concentration of the flue gas decrease,which indicates that the high-pressure water mist system plays the role of cooling and dust removal.By comparing various sprinkler laying methods,it is found that the lower sprinkler height has a better effect on the temperature above the fire source,the temperature of the upper flue gas layer,and the concentration of the flue gas.Moreover,when the sprinkler is spread over thewhole transformer,the cooling effect on both the temperature above the fire source and the temperature of the upper flue gas layer is good,whereas the change in the concentration of the flue gas above the fire source is not obvious compared to the case where the sprinkler is not fully spread.展开更多
In order to study the extinguishing performance of high-pressure-water-mist-based systems on the fires originating from power transformers the PyroSim software is used.Different particle velocities and flow rates are ...In order to study the extinguishing performance of high-pressure-water-mist-based systems on the fires originating from power transformers the PyroSim software is used.Different particle velocities and flow rates are considered.The evolution laws of temperature around transformer,flue gas concentration and upper layer temperature of flue gas are analyzed under different boundary conditions.It is shown that the higher the particle velocity is,the lower the smoke concentration is,the better the cooling effect on the upper layer temperature of flue gas layer is,the larger the flow rate is and the better the cooling effect is.展开更多
BACKGROUND This case of gestational gingival tumor is huge and extremely rare in clinical practice.As the growth location of this gingival tumor is in the upper anterior tooth area,it seriously affects the pregnant wo...BACKGROUND This case of gestational gingival tumor is huge and extremely rare in clinical practice.As the growth location of this gingival tumor is in the upper anterior tooth area,it seriously affects the pregnant woman's speech and food,causing great pain to the patient.The use of Nd:YGA water mist laser to remove the gingival tumor resulted in minimal intraoperative bleeding,minimal adverse reactions,and good postoperative healing,which is worthy of clinical promotion and application.CASE SUMMARY The patient,a pregnant woman,reported a large lump in her mouth on the first day of postpartum treatment.Based on medical history and clinical examination,the diagnosis was diagnosed as gestational gingival tumor.Postoperative pathological biopsy also confirmed this diagnosis.The use of Nd:YAG water mist laser to remove the tumor resulted in minimal intraoperative bleeding,clear surgical field of view,short surgical time,and good postoperative healing.CONCLUSION In comparison to traditional surgery,Nd:YAG water mist laser surgery is minimally invasive,minimizes cell damage,reduces bleeding,ensures a clear field of vision,and virtually eliminates postoperative edema,carbonization,and the risk of cross infection.It has unique advantages in oral soft tissue surgery for pregnant patients.Therefore,the clinical application of Nd:YAG water mist laser for the treatment of gestational gingival tumors is an ideal choice.展开更多
This paper puts forward using high-pressure water jet technology to control rock burst in roadway, and analyzes the theory of controlling rock burst in roadway by the weak structure zone model. The weak structure zone...This paper puts forward using high-pressure water jet technology to control rock burst in roadway, and analyzes the theory of controlling rock burst in roadway by the weak structure zone model. The weak structure zone is formed by using high-pressure water jet to cut the coal wall in a continuous and rotational way. In order to study the influence law of weak structure zone in surrounding rock, this paper numerically analyzed the influence law of weak structure zone, and the disturbance law of coal wall and floor under dynamic and static combined load. The results show that when the distance between high-pressure water jet drillings is 3 m and the diameter of drilling is 300 mm, continuous stress superposition zone can be formed. The weak structure zone can transfer and reduce the concentrated static load in surrounding rock, and then form distressed zone. The longer the high-pressure water jet drilling is, the larger the distressed zone is. The stress change and displacement change of non-distressed zone in coal wall and floor are significantly greater than that of distressed zone under dynamic and static combined load. And it shows that the distressed zone can effectively control rock burst in roadway under dynamic and static combined load. High-pressure water jet technology was applied in the haulage gate of 250203 working face in Yanbei Coal Mine, and had gained good effect. The study conclusions provide theoretical foundation and a new guidance for controlling rock burst in roadway.展开更多
China’s first high-pressure hydraulically coupled rock-breaking tunnel boring machine(TBM) was designed to overcome the rock breaking problems of TBM in super-hard rock geology, where high-pressure water jet system i...China’s first high-pressure hydraulically coupled rock-breaking tunnel boring machine(TBM) was designed to overcome the rock breaking problems of TBM in super-hard rock geology, where high-pressure water jet system is configured, including high-flow pump sets, high-pressure rotary joint and high-pressure water jet injection device. In order to investigate the rock breaking performance of high-pressure water-jet-assisted TBM, in situ excavation tests were carried out at the Wan’anxi Water Diversion Project in Longyan, Fujian Province, China, under different water jet pressure and rotational speed. The rock-breaking performance of TBM was analyzed including penetration, cutterhead load, advance rate and field penetration index. The test results show that the adoption of high-pressure water-jet-assisted rock breaking technology can improve the boreability of rock mass, where the TBM penetration increases by 64% under the water jet pressure of 270 MPa. In addition, with the increase of the water jet pressure, the TBM penetration increases and the field penetration index decreases. The auxiliary rock-breaking effect of high-pressure water jet decreases with the increase of cutterhead rotational speed. In the case of the in situ tunneling test parameters of this study, the advance rate is the maximum when the pressure of the high-pressure water jet is 270 MPa and the cutterhead rotational speed is 6 r/min. The technical superiority of high-pressure water-jet-assisted rock breaking technology is highlighted and it provides guidance for the excavation parameter selection of high-pressure hydraulically coupled rock-breaking TBM.展开更多
On March 16–17, 2008, a sea fog occurred in Dianbai in the west of Guangdong Province and was accompanied by a high-pressure synoptic system. Using comprehensive observation datasets, this study analyzes the evolutio...On March 16–17, 2008, a sea fog occurred in Dianbai in the west of Guangdong Province and was accompanied by a high-pressure synoptic system. Using comprehensive observation datasets, this study analyzes the evolution of liquid water content during this sea fog and investigates the relationships between liquid water content and the average diameters and count densities of fog droplets, air temperature, wind speed and turbulence exchanges. The main results are presented as follows. (1) The sea fog showed a quasi-periodic oscillation characteristic, i.e., it developed, disappeared and then developed again. (2) During the sea fog, the number of fog droplets changed significantly while the changes in average diameter of the fog droplets were relatively small. The development and disappearance of the sea fog correlated significantly with the fog droplet numbers. (3) The air-cooling mechanism played a significant role in sea fog formation and development. However, the influences of this mechanism were not evident during fog persistence. (4) During sea fog formation, weak turbulence exchanges were helpful for fog formation. During sea fog development and persistence, liquid water content increased when turbulence exchanges weakened, and vice versa. The changes in turbulence exchanges were closely related to the quasi-periodic oscillations observed in sea fog presence.展开更多
Mine gas extraction in China is difficult due to the characteristics such as micro-porosity,low-permeability and high adsorption of coal seams.The pulsed mechanismof a high-pressure pulsed water jet was studied throug...Mine gas extraction in China is difficult due to the characteristics such as micro-porosity,low-permeability and high adsorption of coal seams.The pulsed mechanismof a high-pressure pulsed water jet was studied through theoretical analysis,experimentand field measurement.The results show that high-pressure pulsed water jet has threedynamic properties.What's more,the three dynamic effects can be found in low-permeabilitycoal seams.A new pulsed water jet with 200-1 000 Hz oscillation frequency andpeak pressure 2.5 times than average pressure was introduced.During bubble collapsing,sound vibration and instantaneous high pressures over 100 MPa enhanced the cuttingability of the high-pressure jet.Through high-pressure pulsed water jet drilling and slotting,the exposure area of coal bodies was greatly enlarged and pressure of the coal seamsrapidly decreased.Therefore,the permeability of coal seams was improved and gas absorptionrate also decreased.Application results show that gas adsorption rate decreasedby 30%-40%and the penetrability coefficient increased 100 times.This proves that high-pressurepulsed water is more efficient than other conventional methods.展开更多
Water injection for oil displacement is one of the most effective ways to develop fractured-vuggy carbonate reservoirs.With the increase in the number of rounds of water injection,the development effect gradually fail...Water injection for oil displacement is one of the most effective ways to develop fractured-vuggy carbonate reservoirs.With the increase in the number of rounds of water injection,the development effect gradually fails.The emergence of high-pressure capacity expansion and water injection technology allows increased production from old wells.Although high-pressure capacity expansion and water injection technology has been implemented in practice for nearly 10 years in fractured-vuggy reservoirs,its mechanism remains unclear,and the water injection curve is not apparent.In the past,evaluating its effect could only be done by measuring the injection-production volume.In this study,we analyze the mechanism of high-pressure capacity expansion and water injection.We propose a fluid exchange index for high-pressure capacity expansion and water injection and establish a discrete model suitable for high-pressure capacity expansion and water injection curves in fractured-vuggy reservoirs.We propose the following mechanisms:replenishing energy,increasing energy,replacing energy,and releasing energy.The above mechanisms can be identified by the high-pressure capacity expansion and water injection curve of the well HA6X in the Halahatang Oilfield in the Tarim Basin.By solving the basic model,the relative errors of Reservoirs I and II are found to be 1.9%and 1.5%,respectively,and the application of field examples demonstrates that our proposed high-pressure capacity expansion and water injection indicator curve is reasonable and reliable.This research can provide theoretical support for high-pressure capacity expansion and water injection technology in fracture-vuggy carbonate reservoirs.展开更多
The effects of a fine water mist environment in a semi-confined blast chamber on the chemical and thermodynamic processes following detonation of a 20 g PE4 explosive charge have been investigated.The effects were qua...The effects of a fine water mist environment in a semi-confined blast chamber on the chemical and thermodynamic processes following detonation of a 20 g PE4 explosive charge have been investigated.The effects were quantified by the analysis of pressure profiles recorded where several parameters including arrival time of the shock at the sensors, peak overpressures, specific impulse of the positive phase, period of the negative phase and the specific impulse of the multiple reflections were quantified.The effect of the fine water mist on the arrival time, peak pressures and the specific impulse of the positive phase agrees with previous findings in literature. In this paper, the focus is on the implications of the fine water mist on the negative phase and the impulse of multiple pressure reflections. The period of the negative phase was found to have increased by 40% and with higher negative peak pressure in the mist condition compared to the atmospheric condition. The activities of the multiple pressure reflections were found to have decreased considerably, both in number and in amplitude leading to lower impulses(by about 60%) for the water mist conditions.展开更多
To enhance the explosion suppression effects of water mist, various potassium halide additives were tested in a confined vessel filled with a 10% mixture of methane/air. Air and CO2(0.7 MPa) were used as driver gases....To enhance the explosion suppression effects of water mist, various potassium halide additives were tested in a confined vessel filled with a 10% mixture of methane/air. Air and CO2(0.7 MPa) were used as driver gases. The results revealed that halide additives exhibit considerable suppression effects on explosion overpressure. A30% KI mist decreased the explosion overpressure by 27.46% compared with the suppression by pure water mist under the same conditions. When CO2 is used as the driver gas, it will dissolve in water under high pressure.The synergistic effect of a CO2 solution with an effective additive afforded significant suppression. Under the same conditions, the overpressures suppressed by a mist of 30% KI + 0.7 MPa CO2 solution decreased by 33.53% compared with those suppressed by pure water mist driven by air. The synergistic suppression effect is much better than that of a 0.7 MPa CO2 solution mist or 30% KI mist alone. The multicomponent additives can be considered when suppressing methane/air explosions with pressure-formed water mist.展开更多
The natural gas pipeline from Platform QKI8-1 in the southwest of Bohai Bay to the onshore processing facility is a subsea wet gas pipeline exposed to high pressure and low temperature for a long distance. Blockages i...The natural gas pipeline from Platform QKI8-1 in the southwest of Bohai Bay to the onshore processing facility is a subsea wet gas pipeline exposed to high pressure and low temperature for a long distance. Blockages in the pipeline occur occasionally. To maintain the natural gas flow in the pipeline, we proposed a method for analyzing blockages and ascribed them to the hydrate formation and agglomeration. A new high-pressure flow loop was developed to investigate hydrate plug formation and hydrate particle size, using a mixture of diesel oil, water, and natural gas as experimental fluids. The influences of pressure and initial flow rate were also studied. Experimental results indicated that when the flow rate was below 850 kg/h, gas hydrates would form and then plug the pipeline, even at a low water content (10%) of a water/oil emulsion. Furthermore, some practical suggestions were made for daily management of the subsea pipeline.展开更多
Combined effects of obstacles and fine water mist on a methane-air explosion of a semi-closed pipe were investigated experimentally.In this study,the diameter of the water mist,the location,and the number of obstacles...Combined effects of obstacles and fine water mist on a methane-air explosion of a semi-closed pipe were investigated experimentally.In this study,the diameter of the water mist,the location,and the number of obstacles was considered.The results demonstrated that 5 μm water mist present a significant suppression affected while 45 μm shows a slight promotion effected on a gas explosion of the condition without obstacles.In the presence of an obstacle,however,the inhibitory effect of 5 μm water veils of mist dropped significantly during flame propagation,and the effect of 45 μm water veils of mist changed from the enhancement of inhibition,and its inhibitory effect was significant.The inhibitory effect of 45 μm water veils of mist on gas explosion weakened firstly and then enhanced with the increasing distance between obstacle location from the ignition location as well as in several obstacles.展开更多
The main objective of the present study was introduced water mist suppressiontechnology to prevent and control gas burning which occurred during drilling at Wu20160working-face in No.10 coal mine of Pingdingshan Ltd.....The main objective of the present study was introduced water mist suppressiontechnology to prevent and control gas burning which occurred during drilling at Wu20160working-face in No.10 coal mine of Pingdingshan Ltd..Based on the self-developed ex-periment platform,a series of fire suppression tests to evaluate the performance of a watermist system were conducted.The detailed measurements of the spray characteristics,i.e.,the Sauter Mean Diameter(SMD),the velocity and spray angle which are the main pa-rameters considered in the Study,were obtained by using LS-2000 Sizer.The amount ofwater consumed and the water flux density distribution over the cross section downstreamthe nozzle exit were measured by cup collector method.The operating pressure of thewater mist nozzle is set to 0.5 MPa,the droplet SMD of 104 pm,the water flux density dis-tribution from 0.71 to 8.47 L/(m^2.min),the average velocity of 2.14 m/s.The experimentalresults show that the averaged time required for extinguishment is 3.14 s,and the corre-sponding amount of water used during fire test is about 0.11 kg.The gas fire suppressionsystem reduces the temperature in combustion chamber of the experimental apparatusbelow the ignition point of the gas,which can effectively avoid the occurrence of the gasfire in coal mine.展开更多
In order to apply ultra-fine water mist technology on spontaneous coal combustion in the goaf of a coal mine, we built a small scale compartment with ultra-fine water mist for restraining coal combustion in a confined...In order to apply ultra-fine water mist technology on spontaneous coal combustion in the goaf of a coal mine, we built a small scale compartment with ultra-fine water mist for restraining coal combustion in a confined space and then investigated the restraining efficiency and related factors. The study obtained the following results: a descending rate of heat release, an increase in 02, the production of CO2 decreased gradually, while the production of CO increased dramatically and quickly and then decreased; ultimately it tended to become stable after the discharge of an ultra-fine water mist. The technology showed that the ultra-fine water mist can effectively reduce the heat release rate of coal and the rate to generate components. We found that the restraining effect relied on the mist flux, the discharge time and other factors. A sufficient amount of mist has a better effect compared to an insufficient amount of mist. To combat coal combustion, the greater the discharge time, the better coal flames are extinguished.展开更多
Water mist technology provides efficient firefighting performance while there is still room for improvement. So varieties of additives have been studied in recent years both at home and abroad. The self-made additives...Water mist technology provides efficient firefighting performance while there is still room for improvement. So varieties of additives have been studied in recent years both at home and abroad. The self-made additives are used to compare the firefighting performance of diesel and heptane fire in open space. By adjusting the concentration of substance in the additives and conducting the experiment under the pressure of 0.3 MPa,0.5 MPa and 0.7 MPa,extinguish time and temperature are measured in the experiment. Through the experiments using different fuels,it can be found when the fuel is heptane that has a lower ignition point and a higher evaporation rate, the water mist additive can still significantly improve the firefighting performance. According to the data based on different concentrations of fluorinated surfactants,we find that fluorinated surfactants are the main substance to improve the performances by changing physical property of water mist. Optimal proportion of the additives for firefighting performance is found by experiment results.展开更多
Electric discharge in and in contact with water can accompany ultraviolet(UV)radiation and electron impact, which can generate a large number of active species such as hydroxyl radicals(OH), oxygen radical(O), o...Electric discharge in and in contact with water can accompany ultraviolet(UV)radiation and electron impact, which can generate a large number of active species such as hydroxyl radicals(OH), oxygen radical(O), ozone(O_3) and hydrogen peroxide(H_2O_2). In this paper, a nonthermal plasma processing system was established by means of dielectric barrier discharge(DBD)arrays in water mist spray. The relationship between droplet size and water content was examined,and the effects of the concentrations of oxides in both treated water and gas were investigated under different water content and discharge time. The relative intensity of UV spectra from DBD in water mist was a function of water content. The concentrations of both O_3 and nitrogen dioxide(NO_2) in DBD room decreased with increasing water content. Moreover, the concentrations of H_2O_2, O_3 and nitrogen oxides(NOx) in treated water decreased with increasing water content,and all the ones enhanced after discharge. The experimental results were further analyzed by chemical reaction equations and commented by physical principles as much as possible. At last,the water containing phenol was tested in this system for the concentration from 100 mg/L to9.8 mg/L in a period of 35 min.展开更多
Okinawa in the subtropical islands enclosed in the ocean has a problem that corrosion of structures progresses quickly because of high temperature, high humidity and adhesion of sea-water mists flying from sea. Author...Okinawa in the subtropical islands enclosed in the ocean has a problem that corrosion of structures progresses quickly because of high temperature, high humidity and adhesion of sea-water mists flying from sea. Author is interested in corrosion of bridge made of weatherability steel. Therefore, it needs to investigate the flow structure around bridge beams and behavior of sea-water mist (droplet). In this paper, flow visualization and PIV are attempted to understand the flow structures around bridge beams and, furthermore, numerical approach of motion of droplets is attempted to understand the collision of sea-water mists on the bridge wall.展开更多
Interaction between water mist and fire smoke is studied by experiments in an ISO 9705 room, The variation of 02, CO and CO2 concentration is disclosed, and the mathematical models of smoke component con- centration w...Interaction between water mist and fire smoke is studied by experiments in an ISO 9705 room, The variation of 02, CO and CO2 concentration is disclosed, and the mathematical models of smoke component con- centration with water mist pressure and ventilation speed are established according to the experimental results. It is found in the experiment that the smoke component concentration will break when ventilation speed exceeds 1.5 kg/s. This paper provides necessary theory for water mist technology using in smoke restraining.展开更多
The study adopted a 20-foot long container to simulate the situation inside a turbine cabin. Water mist sprays were installed internally and used to perform fire extinguishing tests. Under these different scenarios, s...The study adopted a 20-foot long container to simulate the situation inside a turbine cabin. Water mist sprays were installed internally and used to perform fire extinguishing tests. Under these different scenarios, several operating factors were adjusted with the results of each adjustment subsequently measured. The operating factors studied included: operating pressures, foam concentrations, cabin opening issues, and obstacles. Each of the factors was compared with the others so as to find out which combinations would be most suitable for a water mist spray system installed inside a wind turbine cabin. The presence of obstructions hinders the direct impact of the mist spray on the fire source and in average an additional 2 to 3 minutes is required to put out the fire. This study found that the effect of the foam-water ratio is linear. Regardless of the scenario, the optimum mixture ratio is 3%. The line graph shows that the most unsuitable aqueous film-forming mixture ratio is 6%. This experiment found that the main fire extinguishing mechanism of water mist spray is the cooling of a large area via water droplets. This system is very effective in bringing down the temperature. The addition of foam in water mist spray, however, impaired the effectiveness of the cooling effect although the fire control mechanism via emulsification markedly reduced the time required to put out the fire. The increase in foam magnification will considerably enhance the fire extinguishing efficiency.展开更多
The cooling of a(pebble bed)spent fuel in a high-temperature gas-cooled reactor(HTGR)is adversely affected by an increase in the temperature of the used gas(air).To investigate this problem,a configuration consisting ...The cooling of a(pebble bed)spent fuel in a high-temperature gas-cooled reactor(HTGR)is adversely affected by an increase in the temperature of the used gas(air).To investigate this problem,a configuration consisting of three copper spheres arranged in tandem subjected to a forced mistflow inside a cylindrical channel is considered.The heat transfer coefficients and related variations as a function of Reynolds number are investigated accord-ingly.The experimental results show that when compared to those with only airflow,the heat transfer coefficient of the spherical elements with mistflow(j=112 kg/m2 hr,Re=55000)increases by 180%,75%,and 20%,respec-tively for thefirst,second,and third spherical element(the corresponding heat transfer enhancement ratio being 2.3,1.4,and 1.1).Additional numerical simulations reveal that the presence of stagnant zones with intense vortex formation around each spherical element contributes significantly to determine the heat transfer behavior.展开更多
基金supported by Science and Technology Projects Funded by State Grid Corporation of China (5200202024105A0000).
文摘To thoroughly study the extinguishing effect of a high-pressure water mist fire extinguishing system when a transformer fire occurs,a 3D experimental model of a transformer is established in this work by employing Fire Dynamics Simulator(FDS)software.More specifically,by setting different parameters,the process of the highpressure water mist fire extinguishing system with the presence of both diverse ambient temperatures and water mist sprinkler laying conditions is simulated.In addition,the fire extinguishing effect of the employed high-pressure water mist system with the implementation of different strategies is systematically analyzed.The extracted results show that a fire source farther away fromthe centerline leads to a lower local temperature distribution.In addition,as the ambient temperature increases,the temperature above the fire source decreases,while the temperature and the concentrationof theupperflue gas layer bothdecrease.Interestingly,after thehigh-pressurewatermist sprinkler begins to operate,both the temperature distribution above the fire source and the concentration of the flue gas decrease,which indicates that the high-pressure water mist system plays the role of cooling and dust removal.By comparing various sprinkler laying methods,it is found that the lower sprinkler height has a better effect on the temperature above the fire source,the temperature of the upper flue gas layer,and the concentration of the flue gas.Moreover,when the sprinkler is spread over thewhole transformer,the cooling effect on both the temperature above the fire source and the temperature of the upper flue gas layer is good,whereas the change in the concentration of the flue gas above the fire source is not obvious compared to the case where the sprinkler is not fully spread.
基金This work was supported by Science and Technology Project Funded by State Grid Henan Electric Power Company(521702200004)Henan Province Key R&D and Promotion Special(Technology Research)Project(212102210016)Opening Fund of State Key Laboratory of Fire Science(SKLFS)under Grant No.HZ2021-KF11.
文摘In order to study the extinguishing performance of high-pressure-water-mist-based systems on the fires originating from power transformers the PyroSim software is used.Different particle velocities and flow rates are considered.The evolution laws of temperature around transformer,flue gas concentration and upper layer temperature of flue gas are analyzed under different boundary conditions.It is shown that the higher the particle velocity is,the lower the smoke concentration is,the better the cooling effect on the upper layer temperature of flue gas layer is,the larger the flow rate is and the better the cooling effect is.
文摘BACKGROUND This case of gestational gingival tumor is huge and extremely rare in clinical practice.As the growth location of this gingival tumor is in the upper anterior tooth area,it seriously affects the pregnant woman's speech and food,causing great pain to the patient.The use of Nd:YGA water mist laser to remove the gingival tumor resulted in minimal intraoperative bleeding,minimal adverse reactions,and good postoperative healing,which is worthy of clinical promotion and application.CASE SUMMARY The patient,a pregnant woman,reported a large lump in her mouth on the first day of postpartum treatment.Based on medical history and clinical examination,the diagnosis was diagnosed as gestational gingival tumor.Postoperative pathological biopsy also confirmed this diagnosis.The use of Nd:YAG water mist laser to remove the tumor resulted in minimal intraoperative bleeding,clear surgical field of view,short surgical time,and good postoperative healing.CONCLUSION In comparison to traditional surgery,Nd:YAG water mist laser surgery is minimally invasive,minimizes cell damage,reduces bleeding,ensures a clear field of vision,and virtually eliminates postoperative edema,carbonization,and the risk of cross infection.It has unique advantages in oral soft tissue surgery for pregnant patients.Therefore,the clinical application of Nd:YAG water mist laser for the treatment of gestational gingival tumors is an ideal choice.
基金supported by the National Natural Science Foundation of China (Nos. 51574243, 51404269)the Fundamental Research Funds for the Central Universities of China (No. 2014XT01)+1 种基金Guizhou Science and Technology Foundation of China (No. 20152072)the Priority Academic Program Development of Jiangsu Higher Education Institutions, China (No. SZBF2011-6B35)
文摘This paper puts forward using high-pressure water jet technology to control rock burst in roadway, and analyzes the theory of controlling rock burst in roadway by the weak structure zone model. The weak structure zone is formed by using high-pressure water jet to cut the coal wall in a continuous and rotational way. In order to study the influence law of weak structure zone in surrounding rock, this paper numerically analyzed the influence law of weak structure zone, and the disturbance law of coal wall and floor under dynamic and static combined load. The results show that when the distance between high-pressure water jet drillings is 3 m and the diameter of drilling is 300 mm, continuous stress superposition zone can be formed. The weak structure zone can transfer and reduce the concentrated static load in surrounding rock, and then form distressed zone. The longer the high-pressure water jet drilling is, the larger the distressed zone is. The stress change and displacement change of non-distressed zone in coal wall and floor are significantly greater than that of distressed zone under dynamic and static combined load. And it shows that the distressed zone can effectively control rock burst in roadway under dynamic and static combined load. High-pressure water jet technology was applied in the haulage gate of 250203 working face in Yanbei Coal Mine, and had gained good effect. The study conclusions provide theoretical foundation and a new guidance for controlling rock burst in roadway.
基金Project(2020YFF0426370) supported by the National Key Research and Development Program of ChinaProject(SF-202010) supported by the Water Conservancy Technology Demonstration,China。
文摘China’s first high-pressure hydraulically coupled rock-breaking tunnel boring machine(TBM) was designed to overcome the rock breaking problems of TBM in super-hard rock geology, where high-pressure water jet system is configured, including high-flow pump sets, high-pressure rotary joint and high-pressure water jet injection device. In order to investigate the rock breaking performance of high-pressure water-jet-assisted TBM, in situ excavation tests were carried out at the Wan’anxi Water Diversion Project in Longyan, Fujian Province, China, under different water jet pressure and rotational speed. The rock-breaking performance of TBM was analyzed including penetration, cutterhead load, advance rate and field penetration index. The test results show that the adoption of high-pressure water-jet-assisted rock breaking technology can improve the boreability of rock mass, where the TBM penetration increases by 64% under the water jet pressure of 270 MPa. In addition, with the increase of the water jet pressure, the TBM penetration increases and the field penetration index decreases. The auxiliary rock-breaking effect of high-pressure water jet decreases with the increase of cutterhead rotational speed. In the case of the in situ tunneling test parameters of this study, the advance rate is the maximum when the pressure of the high-pressure water jet is 270 MPa and the cutterhead rotational speed is 6 r/min. The technical superiority of high-pressure water-jet-assisted rock breaking technology is highlighted and it provides guidance for the excavation parameter selection of high-pressure hydraulically coupled rock-breaking TBM.
基金Natural Science Foundation of China (40675013)Foundation project of Nanjing University of Information Science & TechnologyProject on natural science for universities and colleges in Jiangsu province
文摘On March 16–17, 2008, a sea fog occurred in Dianbai in the west of Guangdong Province and was accompanied by a high-pressure synoptic system. Using comprehensive observation datasets, this study analyzes the evolution of liquid water content during this sea fog and investigates the relationships between liquid water content and the average diameters and count densities of fog droplets, air temperature, wind speed and turbulence exchanges. The main results are presented as follows. (1) The sea fog showed a quasi-periodic oscillation characteristic, i.e., it developed, disappeared and then developed again. (2) During the sea fog, the number of fog droplets changed significantly while the changes in average diameter of the fog droplets were relatively small. The development and disappearance of the sea fog correlated significantly with the fog droplet numbers. (3) The air-cooling mechanism played a significant role in sea fog formation and development. However, the influences of this mechanism were not evident during fog persistence. (4) During sea fog formation, weak turbulence exchanges were helpful for fog formation. During sea fog development and persistence, liquid water content increased when turbulence exchanges weakened, and vice versa. The changes in turbulence exchanges were closely related to the quasi-periodic oscillations observed in sea fog presence.
基金Supported by the National Natural Science Foundation of China(50604019)the Innovation Team Foundation of China(50621403)
文摘Mine gas extraction in China is difficult due to the characteristics such as micro-porosity,low-permeability and high adsorption of coal seams.The pulsed mechanismof a high-pressure pulsed water jet was studied through theoretical analysis,experimentand field measurement.The results show that high-pressure pulsed water jet has threedynamic properties.What's more,the three dynamic effects can be found in low-permeabilitycoal seams.A new pulsed water jet with 200-1 000 Hz oscillation frequency andpeak pressure 2.5 times than average pressure was introduced.During bubble collapsing,sound vibration and instantaneous high pressures over 100 MPa enhanced the cuttingability of the high-pressure jet.Through high-pressure pulsed water jet drilling and slotting,the exposure area of coal bodies was greatly enlarged and pressure of the coal seamsrapidly decreased.Therefore,the permeability of coal seams was improved and gas absorptionrate also decreased.Application results show that gas adsorption rate decreasedby 30%-40%and the penetrability coefficient increased 100 times.This proves that high-pressurepulsed water is more efficient than other conventional methods.
基金supported by the China Postdoctoral Science Foundation(No.M2019650965)Major R&D Plan of Sichuan Province(No.2020YFQ0034)the National Natural Science Fund Projects(Grant No.51804253).
文摘Water injection for oil displacement is one of the most effective ways to develop fractured-vuggy carbonate reservoirs.With the increase in the number of rounds of water injection,the development effect gradually fails.The emergence of high-pressure capacity expansion and water injection technology allows increased production from old wells.Although high-pressure capacity expansion and water injection technology has been implemented in practice for nearly 10 years in fractured-vuggy reservoirs,its mechanism remains unclear,and the water injection curve is not apparent.In the past,evaluating its effect could only be done by measuring the injection-production volume.In this study,we analyze the mechanism of high-pressure capacity expansion and water injection.We propose a fluid exchange index for high-pressure capacity expansion and water injection and establish a discrete model suitable for high-pressure capacity expansion and water injection curves in fractured-vuggy reservoirs.We propose the following mechanisms:replenishing energy,increasing energy,replacing energy,and releasing energy.The above mechanisms can be identified by the high-pressure capacity expansion and water injection curve of the well HA6X in the Halahatang Oilfield in the Tarim Basin.By solving the basic model,the relative errors of Reservoirs I and II are found to be 1.9%and 1.5%,respectively,and the application of field examples demonstrates that our proposed high-pressure capacity expansion and water injection indicator curve is reasonable and reliable.This research can provide theoretical support for high-pressure capacity expansion and water injection technology in fracture-vuggy carbonate reservoirs.
文摘The effects of a fine water mist environment in a semi-confined blast chamber on the chemical and thermodynamic processes following detonation of a 20 g PE4 explosive charge have been investigated.The effects were quantified by the analysis of pressure profiles recorded where several parameters including arrival time of the shock at the sensors, peak overpressures, specific impulse of the positive phase, period of the negative phase and the specific impulse of the multiple reflections were quantified.The effect of the fine water mist on the arrival time, peak pressures and the specific impulse of the positive phase agrees with previous findings in literature. In this paper, the focus is on the implications of the fine water mist on the negative phase and the impulse of multiple pressure reflections. The period of the negative phase was found to have increased by 40% and with higher negative peak pressure in the mist condition compared to the atmospheric condition. The activities of the multiple pressure reflections were found to have decreased considerably, both in number and in amplitude leading to lower impulses(by about 60%) for the water mist conditions.
基金Supported by the Key Technologies R&D Program of Tianjin(15ZCZDSF00550)the“Strengthen Police Force by Science and Technology” Special Foundation on Basic Research of Ministry of Public Security(2015GABJC28)the Key Technical Research Plan of Ministry of Public Security(2017JSYJA13).
文摘To enhance the explosion suppression effects of water mist, various potassium halide additives were tested in a confined vessel filled with a 10% mixture of methane/air. Air and CO2(0.7 MPa) were used as driver gases. The results revealed that halide additives exhibit considerable suppression effects on explosion overpressure. A30% KI mist decreased the explosion overpressure by 27.46% compared with the suppression by pure water mist under the same conditions. When CO2 is used as the driver gas, it will dissolve in water under high pressure.The synergistic effect of a CO2 solution with an effective additive afforded significant suppression. Under the same conditions, the overpressures suppressed by a mist of 30% KI + 0.7 MPa CO2 solution decreased by 33.53% compared with those suppressed by pure water mist driven by air. The synergistic suppression effect is much better than that of a 0.7 MPa CO2 solution mist or 30% KI mist alone. The multicomponent additives can be considered when suppressing methane/air explosions with pressure-formed water mist.
基金support from Subtopics of National Science and Technology Major Project(2011ZX05026-004-03)the National Natural Science Foundation of China (51104167)
文摘The natural gas pipeline from Platform QKI8-1 in the southwest of Bohai Bay to the onshore processing facility is a subsea wet gas pipeline exposed to high pressure and low temperature for a long distance. Blockages in the pipeline occur occasionally. To maintain the natural gas flow in the pipeline, we proposed a method for analyzing blockages and ascribed them to the hydrate formation and agglomeration. A new high-pressure flow loop was developed to investigate hydrate plug formation and hydrate particle size, using a mixture of diesel oil, water, and natural gas as experimental fluids. The influences of pressure and initial flow rate were also studied. Experimental results indicated that when the flow rate was below 850 kg/h, gas hydrates would form and then plug the pipeline, even at a low water content (10%) of a water/oil emulsion. Furthermore, some practical suggestions were made for daily management of the subsea pipeline.
基金financial supports of the National Key Research and Development Program of China(2018YFC0808103)the National Natural Science Foundation of China (51774115, 51604095)。
文摘Combined effects of obstacles and fine water mist on a methane-air explosion of a semi-closed pipe were investigated experimentally.In this study,the diameter of the water mist,the location,and the number of obstacles was considered.The results demonstrated that 5 μm water mist present a significant suppression affected while 45 μm shows a slight promotion effected on a gas explosion of the condition without obstacles.In the presence of an obstacle,however,the inhibitory effect of 5 μm water veils of mist dropped significantly during flame propagation,and the effect of 45 μm water veils of mist changed from the enhancement of inhibition,and its inhibitory effect was significant.The inhibitory effect of 45 μm water veils of mist on gas explosion weakened firstly and then enhanced with the increasing distance between obstacle location from the ignition location as well as in several obstacles.
基金Supported by the Natural Science Foundation of China(50274061,50476033)The Outstanding Talents Innovative Foundation of Henan Province of China(421000800)the Natural Science Foundation of HPU(646102)
文摘The main objective of the present study was introduced water mist suppressiontechnology to prevent and control gas burning which occurred during drilling at Wu20160working-face in No.10 coal mine of Pingdingshan Ltd..Based on the self-developed ex-periment platform,a series of fire suppression tests to evaluate the performance of a watermist system were conducted.The detailed measurements of the spray characteristics,i.e.,the Sauter Mean Diameter(SMD),the velocity and spray angle which are the main pa-rameters considered in the Study,were obtained by using LS-2000 Sizer.The amount ofwater consumed and the water flux density distribution over the cross section downstreamthe nozzle exit were measured by cup collector method.The operating pressure of thewater mist nozzle is set to 0.5 MPa,the droplet SMD of 104 pm,the water flux density dis-tribution from 0.71 to 8.47 L/(m^2.min),the average velocity of 2.14 m/s.The experimentalresults show that the averaged time required for extinguishment is 3.14 s,and the corre-sponding amount of water used during fire test is about 0.11 kg.The gas fire suppressionsystem reduces the temperature in combustion chamber of the experimental apparatusbelow the ignition point of the gas,which can effectively avoid the occurrence of the gasfire in coal mine.
基金Project 50274061 supported by the National Natural Science Foundation of Chinaprovided by the NSFC (50274061)+3 种基金the Program for Changjiang Scholars and Innovative Research Team in University (IRT0618)the Henan Province Basic and Lead-ing-edge Technology Research Program (082300 463205 and 072300420180)the Program for New Century Excellent Talents in University of Henan Province (2005HANCET-05) the Henan Poly-technic University Innovation Funds of Graduate Student Scientific Dissertation (M-20) is gratefully acknowledged
文摘In order to apply ultra-fine water mist technology on spontaneous coal combustion in the goaf of a coal mine, we built a small scale compartment with ultra-fine water mist for restraining coal combustion in a confined space and then investigated the restraining efficiency and related factors. The study obtained the following results: a descending rate of heat release, an increase in 02, the production of CO2 decreased gradually, while the production of CO increased dramatically and quickly and then decreased; ultimately it tended to become stable after the discharge of an ultra-fine water mist. The technology showed that the ultra-fine water mist can effectively reduce the heat release rate of coal and the rate to generate components. We found that the restraining effect relied on the mist flux, the discharge time and other factors. A sufficient amount of mist has a better effect compared to an insufficient amount of mist. To combat coal combustion, the greater the discharge time, the better coal flames are extinguished.
基金Opening Fund of State Key Laboratory of Fire Science,University of Science and Technology of China(No.HZ2011-KF04)
文摘Water mist technology provides efficient firefighting performance while there is still room for improvement. So varieties of additives have been studied in recent years both at home and abroad. The self-made additives are used to compare the firefighting performance of diesel and heptane fire in open space. By adjusting the concentration of substance in the additives and conducting the experiment under the pressure of 0.3 MPa,0.5 MPa and 0.7 MPa,extinguish time and temperature are measured in the experiment. Through the experiments using different fuels,it can be found when the fuel is heptane that has a lower ignition point and a higher evaporation rate, the water mist additive can still significantly improve the firefighting performance. According to the data based on different concentrations of fluorinated surfactants,we find that fluorinated surfactants are the main substance to improve the performances by changing physical property of water mist. Optimal proportion of the additives for firefighting performance is found by experiment results.
基金supported by National Natural Science Foundation of China(Nos.11274092,51107033,11404092,11274091)the Nantong Science and Technology Project,China(No.BK2014024)+1 种基金the Open Project of Jiangsu Province Key Laboratory of Environmental Engineering,China(No.KF2014001)the Fundamental Research Funds for the Central Universities,China(No.2014B11414)
文摘Electric discharge in and in contact with water can accompany ultraviolet(UV)radiation and electron impact, which can generate a large number of active species such as hydroxyl radicals(OH), oxygen radical(O), ozone(O_3) and hydrogen peroxide(H_2O_2). In this paper, a nonthermal plasma processing system was established by means of dielectric barrier discharge(DBD)arrays in water mist spray. The relationship between droplet size and water content was examined,and the effects of the concentrations of oxides in both treated water and gas were investigated under different water content and discharge time. The relative intensity of UV spectra from DBD in water mist was a function of water content. The concentrations of both O_3 and nitrogen dioxide(NO_2) in DBD room decreased with increasing water content. Moreover, the concentrations of H_2O_2, O_3 and nitrogen oxides(NOx) in treated water decreased with increasing water content,and all the ones enhanced after discharge. The experimental results were further analyzed by chemical reaction equations and commented by physical principles as much as possible. At last,the water containing phenol was tested in this system for the concentration from 100 mg/L to9.8 mg/L in a period of 35 min.
文摘Okinawa in the subtropical islands enclosed in the ocean has a problem that corrosion of structures progresses quickly because of high temperature, high humidity and adhesion of sea-water mists flying from sea. Author is interested in corrosion of bridge made of weatherability steel. Therefore, it needs to investigate the flow structure around bridge beams and behavior of sea-water mist (droplet). In this paper, flow visualization and PIV are attempted to understand the flow structures around bridge beams and, furthermore, numerical approach of motion of droplets is attempted to understand the collision of sea-water mists on the bridge wall.
基金National Natural Science Foundation Youth Science Foundation (No.50904041)China Postdoctoral Science Foundation (No.20070410067)
文摘Interaction between water mist and fire smoke is studied by experiments in an ISO 9705 room, The variation of 02, CO and CO2 concentration is disclosed, and the mathematical models of smoke component con- centration with water mist pressure and ventilation speed are established according to the experimental results. It is found in the experiment that the smoke component concentration will break when ventilation speed exceeds 1.5 kg/s. This paper provides necessary theory for water mist technology using in smoke restraining.
文摘The study adopted a 20-foot long container to simulate the situation inside a turbine cabin. Water mist sprays were installed internally and used to perform fire extinguishing tests. Under these different scenarios, several operating factors were adjusted with the results of each adjustment subsequently measured. The operating factors studied included: operating pressures, foam concentrations, cabin opening issues, and obstacles. Each of the factors was compared with the others so as to find out which combinations would be most suitable for a water mist spray system installed inside a wind turbine cabin. The presence of obstructions hinders the direct impact of the mist spray on the fire source and in average an additional 2 to 3 minutes is required to put out the fire. This study found that the effect of the foam-water ratio is linear. Regardless of the scenario, the optimum mixture ratio is 3%. The line graph shows that the most unsuitable aqueous film-forming mixture ratio is 6%. This experiment found that the main fire extinguishing mechanism of water mist spray is the cooling of a large area via water droplets. This system is very effective in bringing down the temperature. The addition of foam in water mist spray, however, impaired the effectiveness of the cooling effect although the fire control mechanism via emulsification markedly reduced the time required to put out the fire. The increase in foam magnification will considerably enhance the fire extinguishing efficiency.
文摘The cooling of a(pebble bed)spent fuel in a high-temperature gas-cooled reactor(HTGR)is adversely affected by an increase in the temperature of the used gas(air).To investigate this problem,a configuration consisting of three copper spheres arranged in tandem subjected to a forced mistflow inside a cylindrical channel is considered.The heat transfer coefficients and related variations as a function of Reynolds number are investigated accord-ingly.The experimental results show that when compared to those with only airflow,the heat transfer coefficient of the spherical elements with mistflow(j=112 kg/m2 hr,Re=55000)increases by 180%,75%,and 20%,respec-tively for thefirst,second,and third spherical element(the corresponding heat transfer enhancement ratio being 2.3,1.4,and 1.1).Additional numerical simulations reveal that the presence of stagnant zones with intense vortex formation around each spherical element contributes significantly to determine the heat transfer behavior.