期刊文献+
共找到6,294篇文章
< 1 2 250 >
每页显示 20 50 100
APPLICATION OF HIGH-RESOLUTION MAGNETIC METHOD AND GRADIENT METHOD TO LOCATE ABANDONED BRINE-WELLS IN HUTCHINSON, KANSAS, U.S.A.
1
作者 CHEN Chao XIA Jianghai +2 位作者 XIA Sihao David Laflen Stephen L. Williams 《工程地球物理学报》 2004年第1期17-25,共9页
After successfully locating one abandoned brine well by an electromagnetic method during testing in 2001 and five abandoned brine wells by a high resolution magnetic method during 2002, a high resolution magnetic meth... After successfully locating one abandoned brine well by an electromagnetic method during testing in 2001 and five abandoned brine wells by a high resolution magnetic method during 2002, a high resolution magnetic method was again proposed to search for wells in 2003 when a second sensor was employed to acquire data for calculating the pseudo vertical gradient of magnetic fields. Total area surveyed in 2003 was 1,024,000 ft 2, which was divided into grids with an average size of 10,000 ft 2 and distributed across eight different sites. Magnetic anomalies and their vertical gradients from known brine wells were first recorded as signatures to identify anomalies caused by possible buried brine wells. Of fifty one verified anomalies, thirty one anomalies were due to wells buried at depths from 0 to 8.5 ft: twenty one 6 to 9 inch abandoned brine wells, seven 1.5 to 3 inch probable water wells, one 16 inch dewatering well for a construction site at a depth of 3 ft, and two 4 inch wells on the ground surface. Approximate monopole shaped anomalies were observed from all these wells after data corrections. However, the range of amplitudes of magnetic anomalies from 7,000 to 28,000 nT from these abandoned brine wells was measured. This range of anomalies is mainly due to the thickness and depth of buried wells. Anomaly amplitudes from 1.5 to 3 inch wells are 4,000 to 8,000 nT and linearly correlate with the buried depth. One 3 inch well that caused an anomaly of 13,000 nT could be the inner pipe of a brine well. Gradient anomalies are roughly in a range of 100 to 200 nT/inch for 1.5 to 3 inch wells and 200 to 300 nT/inch for brine wells.As indicated by the potential field theory, gradient data possess higher horizontal resolution than the magnetic field itself. Gradient data provide valuable assistance in determining horizontal locations of anomaly sources for excavation. In practice, however, improvement in the horizontal resolution is limited by survey line spacing. If only one sensor is used in a survey, there is rapid decrease in the horizontal resolution when sensor height increases from 14 to 44 inches. This indicates that it is critical to keep the sensor as close to the ground as possible when hunting buried wells that are close to each other. It also suggests that the downward continuation is useful to increase the horizontal resolution in well hunting. 展开更多
关键词 High resolution magnetic method magnetic gradient method Brine Well
下载PDF
Investigating the relationship between intracranial atherosclerotic plaque remodelling and diabetes using high-resolution vessel wall imaging
2
作者 Yong-Qian Mo Hai-Yu Luo +5 位作者 Han-Wen Zhang Yu-Feng Liu Kan Deng Xiao-Lei Liu Biao Huang Fan Lin 《World Journal of Diabetes》 SCIE 2024年第1期72-80,共9页
BACKGROUND Intracranial atherosclerosis,a leading cause of stroke,involves arterial plaque formation.This study explores the link between plaque remodelling patterns and diabetes using high-resolution vessel wall imag... BACKGROUND Intracranial atherosclerosis,a leading cause of stroke,involves arterial plaque formation.This study explores the link between plaque remodelling patterns and diabetes using high-resolution vessel wall imaging(HR-VWI).AIM To investigate the factors of intracranial atherosclerotic remodelling patterns and the relationship between intracranial atherosclerotic remodelling and diabetes mellitus using HR-VWI.METHODS Ninety-four patients diagnosed with middle cerebral artery or basilar artery INTRODUCTION Intracranial atherosclerotic disease is one of the main causes of ischaemic stroke in the world,accounting for approx-imately 10%of transient ischaemic attacks and 30%-50%of ischaemic strokes[1].It is the most common factor among Asian people[2].The adaptive changes in the structure and function of blood vessels that can adapt to changes in the internal and external environment are called vascular remodelling,which is a common and important pathological mechanism in atherosclerotic diseases,and the remodelling mode of atherosclerotic plaques is closely related to the occurrence of stroke.Positive remodelling(PR)is an outwards compensatory remodelling where the arterial wall grows outwards in an attempt to maintain a constant lumen diameter.For a long time,it was believed that the degree of stenosis can accurately reflect the risk of ischaemic stroke[3-5].Previous studies have revealed that lesions without significant luminal stenosis can also lead to acute events[6,7],as summarized in a recent meta-analysis study in which approximately 50%of acute/subacute ischaemic events were due to this type of lesion[6].Research[8,9]has pointed out that the PR of plaques is more dangerous and more likely to cause acute ischaemic stroke.Previous studies[10-13]have found that there are specific vascular remodelling phenomena in the coronary and carotid arteries of diabetic patients.However,due to the deep location and small lumen of intracranial arteries and limitations of imaging techniques,the relationship between intracranial arterial remodelling and diabetes is still unclear.In recent years,with the development of magnetic resonance technology and the emergence of high-resolution(HR)vascular wall imaging,a clear and multidimensional display of the intracranial vascular wall has been achieved.Therefore,in this study,HR wall imaging(HR-VWI)was used to display the remodelling characteristics of bilateral middle cerebral arteries and basilar arteries and to explore the factors of intracranial vascular remodelling and its relationship with diabetes. 展开更多
关键词 high-resolution vessel wall imaging Intracranial atherosclerosis Vascular remodelling magnetic resonance imaging
下载PDF
Impact of a Magnetic Dipole on Heat Transfer in Non-Conducting Magnetic Fluid Flow over a Stretching Cylinder
3
作者 Anupam Bhandari 《Fluid Dynamics & Materials Processing》 EI 2024年第3期475-486,共12页
The thermal behavior of an electrically non-conducting magnetic liquid flowing over a stretching cylinder under the influence of a magnetic dipole is considered.The governing nonlinear differential equations are solve... The thermal behavior of an electrically non-conducting magnetic liquid flowing over a stretching cylinder under the influence of a magnetic dipole is considered.The governing nonlinear differential equations are solved numerically using a finite element approach,which is properly validated through comparison with earlier results available in the literature.The results for the velocity and temperature fields are provided for different values of the Reynolds number,ferromagnetic response number,Prandtl number,and viscous dissipation parameter.The influence of some physical parameters on skin friction and heat transfer on the walls of the cylinder is also investigated.The applicability of this research to heat control in electronic devices is discussed to a certain extent. 展开更多
关键词 FERROFLUID stretching cylinder finite element method heat transfer magnetic dipole
下载PDF
Semi-analytical investigation of heat transfer in a porous convective radiative moving longitudinal fin exposed to magnetic field in the presence of a shape-dependent trihybrid nanofluid
4
作者 C.G.PAVITHRA B.J.GIREESHA M.L.KEERTHI 《Applied Mathematics and Mechanics(English Edition)》 SCIE EI CSCD 2024年第1期197-216,共20页
The thermal examination of a non-integer-ordered mobile fin with a magnetism in the presence of a trihybrid nanofluid(Fe_3O_4-Au-Zn-blood) is carried out. Three types of nanoparticles, each having a different shape, a... The thermal examination of a non-integer-ordered mobile fin with a magnetism in the presence of a trihybrid nanofluid(Fe_3O_4-Au-Zn-blood) is carried out. Three types of nanoparticles, each having a different shape, are considered. These shapes include spherical(Fe_3O_4), cylindrical(Au), and platelet(Zn) configurations. The combination approach is utilized to evaluate the physical and thermal characteristics of the trihybrid and hybrid nanofluids, excluding the thermal conductivity and dynamic viscosity. These two properties are inferred by means of the interpolation method based on the volume fraction of nanoparticles. The governing equation is transformed into a dimensionless form, and the Adomian decomposition Sumudu transform method(ADSTM) is adopted to solve the conundrum of a moving fin immersed in a trihybrid nanofluid. The obtained results agree well with those numerical simulation results, indicating that this research is reliable. The influence of diverse factors on the thermal overview for varying noninteger values of γ is analyzed and presented in graphical representations. Furthermore, the fluctuations in the heat transfer concerning the pertinent parameters are studied. The results show that the heat flux in the presence of the combination of spherical, cylindrical, and platelet nanoparticles is higher than that in the presence of the combination of only spherical and cylindrical nanoparticles. The temperature at the fin tip increases by 0.705 759% when the value of the Peclet number increases by 400%, while decreases by 11.825 13% when the value of the Hartman number increases by 400%. 展开更多
关键词 convection radiation moving longitudinal fin Adomian decomposition Sumudu transform method(ADSTM) trihybrid nanofluid magnetic field
下载PDF
Measurement of remanent magnetic moment using a torsion pendulum with single frequency modulation method
5
作者 乔敏娜 刘鲁华 +4 位作者 蔡柏松 张雅婷 王晴岚 徐家豪 刘祺 《Chinese Physics B》 SCIE EI CAS CSCD 2023年第5期83-87,共5页
In Tian Qin spaceborne gravitational-wave detectors, the stringent requirements on the magnetic cleanliness of the test masses demand the high resolution ground-based characterization measurement of their magnetic pro... In Tian Qin spaceborne gravitational-wave detectors, the stringent requirements on the magnetic cleanliness of the test masses demand the high resolution ground-based characterization measurement of their magnetic properties. Here we present a single frequency modulation method based on a torsion pendulum to measure the remanent magnetic moment mr of 1.1 kg dummy copper test mass, and the measurement result is(6.45 ± 0.04(stat) ± 0.07(syst)) × 10^(-8)A · m^(2). The measurement precision of the mr is about 0.9 n A · m^(2), well below the present measurement requirement of Tian Qin. The method is particularly useful for measuring extremely low magnetic properties of the materials for use in the construction of space-borne gravitational wave detection and other precision scientific apparatus. 展开更多
关键词 remanent magnetic moment torsion pendulum single frequency modulation method
下载PDF
Design of Rotor Magnetic Barrier Structure of Built-in Permanent Magnet Motor Based on Taguchi Method
6
作者 Shengnan Wu Xianwen Pang +1 位作者 Wenming Tong Yingcong Yao 《CES Transactions on Electrical Machines and Systems》 CSCD 2023年第2期193-201,共9页
In this paper,a 20kW vehicle built-in permanent magnet synchronous motor is taken as an example,and a magnetic barrier structure is added to the rotor of the motor to solve the uneven saturation problem of the rotor s... In this paper,a 20kW vehicle built-in permanent magnet synchronous motor is taken as an example,and a magnetic barrier structure is added to the rotor of the motor to solve the uneven saturation problem of the rotor side magnetic bridge.This structure improves the air-gap flux density waveform of the motor by influencing the internal magnetic flux path of the motor rotor,thus improving the sine of the no-load back EMF waveform of the motor and reducing the torque ripple of the motor.At the same time,Taguchi method is used to optimize the structural parameters of the added magnetic barrier.In order to facilitate the analysis of its uneven saturation phenomenon and improve the optimization effect,a simple equivalent magnetic network(EMN)model considering the uneven saturation of rotor magnetic bridge is established in this paper,and the initial values of optimization factors are selected based on this model.Finally,the no-load back EMF waveform distortion rate,torque ripple and output torque of the optimized motor are compared and analyzed,and the influence of magnetic barrier structure parameters on the electromagnetic performance of the motor is also analyzed.The results show that the optimized motor can not change the output torque of the motor as much as possible on the basis of reducing the waveform distortion rate of no-load back EMF and torque ripple. 展开更多
关键词 Built-in permanent magnet synchronous motor magnetic barrier Taguchi method Equivalent magnetic network model Finite element analysis
下载PDF
Multi-objective optimization of gradient coil for benchtop magnetic resonance imaging system with high-resolution 被引量:1
7
作者 王龙庆 王为民 《Chinese Physics B》 SCIE EI CAS CSCD 2014年第2期589-596,共8页
Significant high magnetic gradient field strength is essential to obtaining high-resolution images in a benchtop mag- netic resonance imaging (BT-MRI) system with permanent magnet. Extending minimum wire spacing and... Significant high magnetic gradient field strength is essential to obtaining high-resolution images in a benchtop mag- netic resonance imaging (BT-MRI) system with permanent magnet. Extending minimum wire spacing and maximum wire width of gradient coils is one of the key solutions to minimize the maximum current density so as to reduce the local heating and generate higher magnetic field gradient strength. However, maximum current density is hard to optimize together with field linearity, stored magnetic energy, and power dissipation by the traditional target field method. In this paper, a new multi-objective method is proposed to optimize the maximum current density, field linearity, stored magnetic energy, and power dissipation in MRI gradient coils. The simulation and experimental results show that the minimum wire spacings are improved by 159% and 62% for the transverse and longitudinal gradient coil respectively. The maximum wire width increases from 0.5 mm to 1.5 mm. Maximum gradient field strengths of 157 mT/m and 405 mT/m for transverse and lon- gitudinal coil are achieved, respectively. The experimental results in BT-MRI instrument demonstrate that the MRI images with in-plane resolution of 50 ~tm can be obtained by using the designed coils. 展开更多
关键词 magnetic resonance imaging gradient coil target field method wire spacing
下载PDF
Effect of magnetic nanoparticles on magnetic field homogeneity 被引量:1
8
作者 郭斯琳 易文通 李壮壮 《Chinese Physics B》 SCIE EI CAS CSCD 2023年第5期188-192,共5页
The mechanism of magnetic nanoparticles(MNPs)affecting magnetic field uniformity is studied in this work.The spatial distribution of MNPs in liquid is simulated based on Monte Carlo method.The induced field of the sin... The mechanism of magnetic nanoparticles(MNPs)affecting magnetic field uniformity is studied in this work.The spatial distribution of MNPs in liquid is simulated based on Monte Carlo method.The induced field of the single MNP is combined with the magnetic field distribution of magnetofluid.In the simulation,magnetic field uniformity is described by a statistical distribution.As the chemical shift(CS)and full width at half maximum(FWHM)of magnetic resonance(MR)spectrum can reflect the uniformity of magnetic field,the simulation is verified by spectrum experiment.Simulation and measurement results prove that the CS and FWHM of the MR spectrum are basically positively correlated with the concentration of MNPs and negatively correlated with the temperature.The research results can explain how MNPs play a role in MR by affecting the uniform magnetic field,which is of great significance in improving the temperature measurement accuracy of magnetic nanothermometers and the spatial resolution of magnetic particle imaging. 展开更多
关键词 magnetic nanoparticle field distribution Monte Carlo method
下载PDF
Abnormal variation of magnetic properties with Ce content in(PrNdCe)_2Fe_(14)B sintered magnets prepared by dual alloy method 被引量:4
9
作者 张雪峰 兰剑亭 +4 位作者 李柱柏 刘艳丽 张乐乐 李永峰 赵倩 《Chinese Physics B》 SCIE EI CAS CSCD 2016年第5期352-356,共5页
Resource-saving(PrNdCe)_2Fe_(14)B sintered magnets with nominal composition(PrNd)_(15-x)Ce_xFe_(77)B_8(x=0–10)were prepared using a dual alloy method by mixing(PrNd)_5Ce_(10)Fe_(77)B_8 with(PrNd)_... Resource-saving(PrNdCe)_2Fe_(14)B sintered magnets with nominal composition(PrNd)_(15-x)Ce_xFe_(77)B_8(x=0–10)were prepared using a dual alloy method by mixing(PrNd)_5Ce_(10)Fe_(77)B_8 with(PrNd)_(15)Fe_(77)B_8 powders. For Ce atomic percent of 1% and 2%, coercivity decreases dramatically. With further increase of Ce atomic percent, the coercivity increases, peaks at 6.38 kOe in(PrNd)_(11)Ce_4Fe_(77)B_8, and then declines gradually. The abnormal dependence of coercivity is likely related to the inhomogeneity of rare earth chemical composition in the intergranular phase, where Pr Nd concentration is strongly dependent on the additive amount of(PrNd)_5Ce_(10)Fe_(77)B_8 powders. In addition, for Ce atomic percent of 8%,7%, and 6% the coercivity is higher than that of magnets prepared by the conventional method, which shows the advantage of the dual alloy method in preparing high abundant rare earth magnets. 展开更多
关键词 permanent magnets Ce element dual alloy method COERCIVITY
下载PDF
Investigation on mechanism of magnetization reversal for nanocrystalline Pr-Fe-B permanent magnets by micromagnetic finite element methods 被引量:4
10
作者 郑波 赵素芬 《Journal of Rare Earths》 SCIE EI CAS CSCD 2009年第1期145-149,共5页
Magnetization configurations were calculated under various magnetic fields for nanocrystalline Pr-Fe-B permanent magnets by micromagnetic finite element method.According to the configurations during demagnetization pr... Magnetization configurations were calculated under various magnetic fields for nanocrystalline Pr-Fe-B permanent magnets by micromagnetic finite element method.According to the configurations during demagnetization process, the mechanism of magnetization reversal was analyzed.For the Pr2Fe14B with 10 nm grains or its composite with 10vol.% α-Fe, the coercivity was determined by nucleation of reversed domain that took place at grain boundaries.However, for Pr2Fe14B with 30 nm grains, coercivity was controlled by pinning of the nucle-ated domain.For Pr2Fe14B/α-Fe with 30vol.% α-Fe, the demagnetization behavior was characterized by continuous reversal of α-Fe moment. 展开更多
关键词 nanocrystalline permanent magnets COERCIVITY MICROmagneticS finite element method rare earths
下载PDF
NuBot:A Magnetic Adhesion Robot with Passive Suspension to Inspect the Steel Lining
11
作者 Hao Xu Youcheng Han +2 位作者 Mingda He Yinghui Li Weizhong Guo 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2023年第3期161-178,共18页
The steel lining of huge facilities is a significant structure,which experiences extreme environments and needs to be inspected periodically after manufacture.However,due to the complexity(crisscross welds,curved surf... The steel lining of huge facilities is a significant structure,which experiences extreme environments and needs to be inspected periodically after manufacture.However,due to the complexity(crisscross welds,curved surface,etc.)of their inside environments,high demands for stable adhesion and curvature adaptability are put forward.This paper presents a novel wheeled magnetic adhesion robot with passive suspension applied in nuclear power containment called NuBot,and mainly focuses on the following aspects:(1)proposing the wheeled locomotion suspension to adapt the robot to the uneven surface;(2)implementing the parameter optimization of NuBot.A comprehensive optimization model is established,and global optimal dimensions are properly chosen from performance atlases;(3)determining the normalization factor and actual dimensional parameters by constraints of the steel lining environment;(4)structure design of the overall robot and the magnetic wheels are completed.Experiments show that the robot can achieve precise locomotion on both strong and weak magnetic walls with various inclination angles,and can stably cross the 5 mm weld seam.Besides,its maximum payload capacity reaches 3.6 kg.Results show that the NuBot designed by the proposed systematic method has good comprehensive capabilities of surface-adaptability,adhesion stability,and payload.Besides,the robot can be applied in more ferromagnetic environments and the design method offers guidance for similar wheeled robots with passive suspension. 展开更多
关键词 Wheeled robot Passive suspension magnetic adhesion Steel lining Design method
下载PDF
SIMUUTION OF ELECTROMAGNETIC TUBE BULGING BASED ON LOOSE COUPLING METHOD 被引量:6
12
作者 LI Zhong LI Chunfeng 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2006年第4期566-569,共4页
A loose coupling method is used to solve the electromagnetic tube bulging. ANSYS/ EMAG is used to model the time varying electromagnetic field with the discharge current used as excitation, in order to obtain the radi... A loose coupling method is used to solve the electromagnetic tube bulging. ANSYS/ EMAG is used to model the time varying electromagnetic field with the discharge current used as excitation, in order to obtain the radial and axial magnetic pressure acting on the tube, the magnetic pressure is then used as boundary conditions to model the high velocity deformation of tube with DYNAFORM, The radial magnetic pressure on the tube decreases from the center to the tube end, axial magnetic pressure is greater near the location equal to the coil height and slight in the other region. The radial displacement of deformed workpicces is distributed uniformly near the tube center and decreases from the center to the end; Deformation from the location equal to coil height to the tube end is little. This distribution is consistent with the distribution of radial pressure; Effect of the axial magnetic pressure on deformation can be ignored, The calculated results show well agreements with the experimental results. 展开更多
关键词 Loose coupling method Electromagnetic tube bulging Excitation magnetic pressure
下载PDF
Numerical and experimental studies on the effectiveness of time-varying electromagnetic fields in reducing electron density
13
作者 郭韶帅 谢楷 +2 位作者 徐晗 付麦霞 牛营营 《Plasma Science and Technology》 SCIE EI CAS CSCD 2023年第6期30-40,共11页
When an aircraft or a hypersonic vehicle re-enters the atmosphere,the plasma sheath generated can severely attenuate electromagnetic wave signals,causing the problem of communication blackout.A new method based on tim... When an aircraft or a hypersonic vehicle re-enters the atmosphere,the plasma sheath generated can severely attenuate electromagnetic wave signals,causing the problem of communication blackout.A new method based on time-varying E×B fields is proposed to improve on the existing static E×B fields and mitigate the radio blackout problem.The use of the existing method is limited by the invalid electron density reduction resulting from current density j=0 A m^(-2)in plasma beyond the Debye radius.The most remarkable feature is the introduction of a time-varying electric field to increase the current density in the plasma to overcome the Debye shielding effect on static electric field.Meanwhile,a magnetic field with the same frequency and phase as the electric field is applied to ensure that the electromagnetic force is always acting on the plasma in one direction.In order to investigate the effect of time-varying E×B fields on the plasma electron density distribution,two directions of voltage application are considered in numerical simulation.The simulation results indicate that different voltage application methods generate electromagnetic forces in different directions in the plasma,resulting in repulsion and vortex effects in the plasma.A comparison of the vortex effect and repulsion effect reveals that the vortex effect is better at reducing the electron density.The local plasma electron density can be reduced by more than 80%through the vortex effect,and the dimensions of the area of reduced electron density reach approximately 6 cm×4 cm,meeting the requirements of electromagnetic wave propagation.Besides,the vortex effect of reducing the electron density in RAM-C(radio attenuation measurements for the study of communication blackout)reentry at an altitude of 40 km is analyzed.On the basis of the simulation results,an experiment based on a rectangular-window discharge device is proposed to demonstrate the effectiveness of the vortex effect.Experimental results show that time-varying E×B fields can reduce the electron density in plasma of 3 cm thickness by 80%at B=0.07 T and U_(0)=1000 V.The investigations confirm the effectiveness of the proposed method in terms of reducing the required strength of the magnetic field and overcoming the Debye shielding effect.Additionally,the method is expected to provide a new way to apply a magnetic window in engineering applications. 展开更多
关键词 BLACKOUT magnetic window method time-varying E×B fields
下载PDF
An Improved Preisach Distribution Function Identification Method Considering the Reversible Magnetization
14
作者 Long Chen Lvsheng Cui +1 位作者 Tong Ben Libing Jing 《CES Transactions on Electrical Machines and Systems》 CSCD 2023年第4期351-357,共7页
This paper presents an identification method of the scalar Preisach model to consider the effect of reversible magnetization in the process of distribution function identification.By reconsidering the identification p... This paper presents an identification method of the scalar Preisach model to consider the effect of reversible magnetization in the process of distribution function identification.By reconsidering the identification process by stripping the influence of reversible components from the measurement data,the Preisach distribution function is identified by the pure irreversible components.In this way,the simulation accuracy of both limiting hysteresis loops and the inner internal symmetrical small hysteresis loop is ensured.Furthermore,through a discrete Preisach plane with a hybrid discretization method,the irreversible magnetic flux density components are computed more efficiently through the improved Preisach model.Finally,the proposed method results are compared with the traditional method and the traditional method considering reversible magnetization and validated by the laboratory test for the B30P105 electrical steel by Epstein frame. 展开更多
关键词 magnetic material Preisach distribution function Reversible magnetization Hybrid discretization method
下载PDF
Effect of Zn^(2+) Content on the Microstructure and Magnetic Properties of Nanocrystalline Ni_(1-x)Zn_xFe_2O_4 Ferrite by a Spraying-coprecipitation Method 被引量:1
15
作者 刘银 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2010年第3期429-431,共3页
Nanocrystalline Ni1-xZnxFe2O4 ferrites with 0≤x≤1 were successfully prepared by a spraying-coprecipitation method.The microstructure was investigated by using XRD and TEM.Magnetic properties were measured with vibra... Nanocrystalline Ni1-xZnxFe2O4 ferrites with 0≤x≤1 were successfully prepared by a spraying-coprecipitation method.The microstructure was investigated by using XRD and TEM.Magnetic properties were measured with vibrating sample magnetometer(VSM) at room temperature.The results show that the grain size of nanocrystalline Ni1-xZnxFe2O4 ferrite calcined at 600 ℃ for 1.5 h is about 30 nm.Lattice parameter and specific saturation magnetization Ms of nanocrystalline Ni1-xZnxFe2O4 ferrite increase with the Zn^2+ ions content at room temperature,and maximum Ms is 66.8 A·m^2·kg^-1 as the Zn^2+ ions content is around 0.5,and coercivity Hc of the nanocrystalline Ni1-xZnxFe2O4 ferrite decreases with Zn^2+ ions content. 展开更多
关键词 nanocrystalline material Ni-Zn ferrite spraying-coprecipitation method magnetic properties MICROSTRUCTURE
下载PDF
Nonreciprocal wide-angle bidirectional absorber based on one-dimensional magnetized gyromagnetic photonic crystals
16
作者 刘又铭 史源坤 +2 位作者 万宝飞 张丹 章海锋 《Chinese Physics B》 SCIE EI CAS CSCD 2023年第4期319-328,共10页
We propose magnetized gyromagnetic photonic crystals(MGPCs)composed of indium antimonide(InSb)and yttrium iron garnet ferrite(YIGF)layers,which possess the properties of nonreciprocal wide-angle bidirectional absorpti... We propose magnetized gyromagnetic photonic crystals(MGPCs)composed of indium antimonide(InSb)and yttrium iron garnet ferrite(YIGF)layers,which possess the properties of nonreciprocal wide-angle bidirectional absorption.Periodical defects in the MGPCs work as filters.Absorption bands(ABs)for the positive and negative propagations arise from the optical Tamm state and resonance in cavities respectively,and they prove to share no overlaps in the studied frequency range.Givenω=2.0138 THz,for the positive propagation,the ABs in the high-frequency range are localized in the interval between 0.66ωand 0.88ω.In the angular range,the ABs for the TE and TM waves reach 60°and 51°,separately.For the negative propagation,the ABs in the low-frequency range are localized in the interval between 0.13ωand 0.3ω.The AB s extend to 60°for the TE waves and 80.4°for the TM waves.There also exists a narrow frequency band in a lower frequency range.The relevant factors,which include the external temperature,the magnetic fields applied to the YIGF,the refractive index of the impedance matching layer,and the defect thickness,are adjusted to investigate the effects on the ABs.All the numerical simulations are based on the transfer matrix method.This work provides an approach to designs of isolators and so on. 展开更多
关键词 nonreciprocal absorption magnetized gyromagnetic photonic crystals transfer matrix method optical Tamm state
下载PDF
Preparation and Magnetic Properties of Mn-Zn Ferrites by the Co-precipitation Method 被引量:1
17
作者 李雪 张俊喜 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2009年第6期875-878,共4页
Mn-Zn ferrites (Mn1-xZnxFe2O4) with different compositions were prepared by the coprecipitation method, and the influences of such synthesis conditions as pH value, composition and volume ratio (R) of the mixed so... Mn-Zn ferrites (Mn1-xZnxFe2O4) with different compositions were prepared by the coprecipitation method, and the influences of such synthesis conditions as pH value, composition and volume ratio (R) of the mixed solution and NH4HCO3 solution on their microstructures and magnetic properties were discussed. The samples were characterized by X-ray diffraction (XRD) and magnetization measurement instrument. Lattice parameters and average crystalline size of the synthesized materials were calculated from the corresponding XRD patterns with the related software Jade.5. For samples of different pH values, only one phase was found when pH values were 7.0, 8.0 and 9.0. The sample with pH value of 7.0 exhibited the highest saturation magnetic induction, the lowest coercive force, and crystallized best. For samples of different R values with pH value of 7.0, only one phase was observed in all samples, and the sample with R value of 2.3 exhibited the highest saturation magnetic induction and the lowest coercive force. The composition has mainly afected the magnetic properties, and the saturation magnetic induction increases with the increase of the content of Zn (x), but decreases when x is beyond 0.6. The trend of coercive force is on the contrary. However, no magnetism is exhibited when the x value is up to 0.8. 展开更多
关键词 co-precipitation method MICROSTRUCTURE magnetic property Mn-Zn ferrite
下载PDF
The structural and magnetic properties of barium ferrite powders prepared by the sol-gel method 被引量:1
18
作者 李颉 张怀武 +2 位作者 李元勋 刘颖力 马岩冰 《Chinese Physics B》 SCIE EI CAS CSCD 2012年第1期467-470,共4页
In this paper, M-type hexagonal barium ferrite powders are synthesized using the sol-gel method. A dried precursor heated in air is analyzed in the temperature range from 50 to 1200 ℃ using thermo-gravimetric analysi... In this paper, M-type hexagonal barium ferrite powders are synthesized using the sol-gel method. A dried precursor heated in air is analyzed in the temperature range from 50 to 1200 ℃ using thermo-gravimetric analysis and differential scanning calorimetry. The effects of the additives and the cacinating temperature on the magnetic properties are investigated, and the results show that single-phase barium ferrite powders can be formed. After heat-treating at 950 ℃ for 4h with 3 wt% additive, the coercivity and saturation magnetization are found to be 440 Oe and 57.9 emu/g, respectively. 展开更多
关键词 barium ferrite sol-gel method POWDER magnetic property
下载PDF
Chaotic Motion Analysis for a Coupled Magnetic-Flow-Mechanical Model of the Rectangular Conductive Thin Plate
19
作者 Xinzong Wang Xiaofang Kang Qingguan Lei 《Computer Modeling in Engineering & Sciences》 SCIE EI 2023年第11期1749-1771,共23页
The chaotic motion behavior of the rectangular conductive thin plate that is simply supported on four sides by airflow andmechanical external excitation in a magnetic field is studied.According to Kirchhoff’s thin pl... The chaotic motion behavior of the rectangular conductive thin plate that is simply supported on four sides by airflow andmechanical external excitation in a magnetic field is studied.According to Kirchhoff’s thin plate theory,considering geometric nonlinearity and using the principle of virtualwork,the nonlinearmotion partial differential equation of the rectangular conductive thin plate is deduced.Using the separate variable method and Galerkin’s method,the system motion partial differential equation is converted into the general equation of the Duffing equation;the Hamilton system is introduced,and the Melnikov function is used to analyze the Hamilton system,and obtain the critical surface for the existence of chaos.The bifurcation diagram,phase portrait,time history response and Poincarémap of the vibration system are obtained by numerical simulation,and the correctness is demonstrated.The results showthatwhen the ratio of external excitation amplitude to damping coefficient is higher than the critical surface,the system will enter chaotic state.The chaotic motion of the rectangular conductive thin plate is affected by different magnetic field distributions and airflow. 展开更多
关键词 Rectangular conductive thin plate CHAOTIC AIRFLOW magnetic field Melnikov function Galerkin’s method
下载PDF
Forward and inverse problem for cardiac magnetic field and electric potential using two boundary element methods 被引量:1
20
作者 唐发宽 王倩 +3 位作者 华宁 唐雪正 陆宏 马平 《Chinese Physics B》 SCIE EI CAS CSCD 2010年第12期144-153,共10页
This paper discusses the forward and inverse problem for cardiac magnetic fields and electric potentials. A torso-heart model established by boundary element method (BEM) is used for studying the distributions of ca... This paper discusses the forward and inverse problem for cardiac magnetic fields and electric potentials. A torso-heart model established by boundary element method (BEM) is used for studying the distributions of cardiac magnetic fields and electric potentials. Because node-to-node and triangle-to-triangle BEM can lead to discrepant field distributions, their properties and influences are compared. Then based on constructed torso-heart model and supposed current source functional model-current dipole array, the magnetic and electric imaging by optimal constrained linear inverse method are applied at the same time. Through figure and reconstructing parameter comparison, though the magnetic current dipole array imaging possesses better reconstructing effect, however node-to-node BEM and triangleto-triangle BEM make little difference to magnetic and electric imaging. 展开更多
关键词 cardiac magnetic imaging cardiac electric imaging boundary element method torsoheart model
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部