期刊文献+
共找到69,823篇文章
< 1 2 250 >
每页显示 20 50 100
Verification and Validation of High-Resolution Inviscid and Viscous Conical Nozzle Flows
1
作者 Luciano K.Araki Rafael B.de R.Borges +1 位作者 Nicholas Dicati P.da Silva Chi-Wang Shu 《Communications on Applied Mathematics and Computation》 EI 2024年第1期533-549,共17页
Capturing elaborated flow structures and phenomena is required for well-solved numerical flows.The finite difference methods allow simple discretization of mesh and model equations.However,they need simpler meshes,e.g... Capturing elaborated flow structures and phenomena is required for well-solved numerical flows.The finite difference methods allow simple discretization of mesh and model equations.However,they need simpler meshes,e.g.,rectangular.The inverse Lax-Wendroff(ILW)procedure can handle complex geometries for rectangular meshes.High-resolution and high-order methods can capture elaborated flow structures and phenomena.They also have strong mathematical and physical backgrounds,such as positivity-preserving,jump conditions,and wave propagation concepts.We perceive an effort toward direct numerical simulation,for instance,regarding weighted essentially non-oscillatory(WENO)schemes.Thus,we propose to solve a challenging engineering application without turbulence models.We aim to verify and validate recent high-resolution and high-order methods.To check the solver accuracy,we solved vortex and Couette flows.Then,we solved inviscid and viscous nozzle flows for a conical profile.We employed the finite difference method,positivity-preserving Lax-Friedrichs splitting,high-resolution viscous terms discretization,fifth-order multi-resolution WENO,ILW,and third-order strong stability preserving Runge-Kutta.We showed the solver is high-order and captured elaborated flow structures and phenomena.One can see oblique shocks in both nozzle flows.In the viscous flow,we also captured a free-shock separation,recirculation,entrainment region,Mach disk,and the diamond-shaped pattern of nozzle flows. 展开更多
关键词 high-resolution COMPRESSIBLE NAVIER-STOKES Free-shock separation Nozzle flow
下载PDF
Accurate Source-Receiver Positioning Method for a High-Resolution Deep-Towed Multichannel Seismic Exploration System
2
作者 LI Jing LIU Kai +5 位作者 WEI Zhengrong ZHANG Liancheng LIU Yangting PEI Yanliang LIU Chenguang LIU Baohua 《Journal of Ocean University of China》 CAS CSCD 2024年第2期415-426,共12页
The near-seabed multichannel seismic exploration systems have yielded remarkable successes in marine geological disaster assessment,marine gas hydrate investigation,and deep-sea mineral exploration owing to their high... The near-seabed multichannel seismic exploration systems have yielded remarkable successes in marine geological disaster assessment,marine gas hydrate investigation,and deep-sea mineral exploration owing to their high vertical and horizontal resolution.However,the quality of deep-towed seismic imaging hinges on accurate source-receiver positioning information.In light of existing technical problems,we propose a novel array geometry inversion method tailored for high-resolution deep-towed multichannel seismic exploration systems.This method is independent of the attitude and depth sensors along a deep-towed seismic streamer,accounting for variations in seawater velocity and seabed slope angle.Our approach decomposes the towed line array into multiline segments and characterizes its geometric shape using the line segment distance and pitch angle.Introducing optimization parameters for seawater velocity and seabed slope angle,we establish an objective function based on the model,yielding results that align with objective reality.Employing the particle swarm optimization algorithm enables synchronous acquisition of optimized inversion results for array geometry and seawater velocity.Experimental validation using theoretical models and practical data verifies that our approach effectively enhances source and receiver positioning inversion accuracy.The algorithm exhibits robust stability and reliability,addressing uncertainties in seismic traveltime picking and complex seabed topography conditions. 展开更多
关键词 high-resolution deep-towed multichannel seismic exploration source-receiver positioning array geometry inversion seawater heterogeneity seabed slope angle
下载PDF
Investigating the relationship between intracranial atherosclerotic plaque remodelling and diabetes using high-resolution vessel wall imaging
3
作者 Yong-Qian Mo Hai-Yu Luo +5 位作者 Han-Wen Zhang Yu-Feng Liu Kan Deng Xiao-Lei Liu Biao Huang Fan Lin 《World Journal of Diabetes》 SCIE 2024年第1期72-80,共9页
BACKGROUND Intracranial atherosclerosis,a leading cause of stroke,involves arterial plaque formation.This study explores the link between plaque remodelling patterns and diabetes using high-resolution vessel wall imag... BACKGROUND Intracranial atherosclerosis,a leading cause of stroke,involves arterial plaque formation.This study explores the link between plaque remodelling patterns and diabetes using high-resolution vessel wall imaging(HR-VWI).AIM To investigate the factors of intracranial atherosclerotic remodelling patterns and the relationship between intracranial atherosclerotic remodelling and diabetes mellitus using HR-VWI.METHODS Ninety-four patients diagnosed with middle cerebral artery or basilar artery INTRODUCTION Intracranial atherosclerotic disease is one of the main causes of ischaemic stroke in the world,accounting for approx-imately 10%of transient ischaemic attacks and 30%-50%of ischaemic strokes[1].It is the most common factor among Asian people[2].The adaptive changes in the structure and function of blood vessels that can adapt to changes in the internal and external environment are called vascular remodelling,which is a common and important pathological mechanism in atherosclerotic diseases,and the remodelling mode of atherosclerotic plaques is closely related to the occurrence of stroke.Positive remodelling(PR)is an outwards compensatory remodelling where the arterial wall grows outwards in an attempt to maintain a constant lumen diameter.For a long time,it was believed that the degree of stenosis can accurately reflect the risk of ischaemic stroke[3-5].Previous studies have revealed that lesions without significant luminal stenosis can also lead to acute events[6,7],as summarized in a recent meta-analysis study in which approximately 50%of acute/subacute ischaemic events were due to this type of lesion[6].Research[8,9]has pointed out that the PR of plaques is more dangerous and more likely to cause acute ischaemic stroke.Previous studies[10-13]have found that there are specific vascular remodelling phenomena in the coronary and carotid arteries of diabetic patients.However,due to the deep location and small lumen of intracranial arteries and limitations of imaging techniques,the relationship between intracranial arterial remodelling and diabetes is still unclear.In recent years,with the development of magnetic resonance technology and the emergence of high-resolution(HR)vascular wall imaging,a clear and multidimensional display of the intracranial vascular wall has been achieved.Therefore,in this study,HR wall imaging(HR-VWI)was used to display the remodelling characteristics of bilateral middle cerebral arteries and basilar arteries and to explore the factors of intracranial vascular remodelling and its relationship with diabetes. 展开更多
关键词 high-resolution vessel wall imaging Intracranial atherosclerosis Vascular remodelling Magnetic resonance imaging
下载PDF
In vivo pilot study into superficial microcirculatory characteristics of colorectal adenomas using novel high-resolution magnifying endoscopy with blue laser imaging
4
作者 Hai-Bin Dong Tao Chen +2 位作者 Xiao-Fei Zhang Yu-Tang Ren Bo Jiang 《World Journal of Gastrointestinal Endoscopy》 2024年第4期206-213,共8页
BACKGROUND No studies have yet been conducted on changes in microcirculatory hemody-namics of colorectal adenomas in vivo under endoscopy.The microcirculation of the colorectal adenoma could be observed in vivo by a n... BACKGROUND No studies have yet been conducted on changes in microcirculatory hemody-namics of colorectal adenomas in vivo under endoscopy.The microcirculation of the colorectal adenoma could be observed in vivo by a novel high-resolution magnification endoscopy with blue laser imaging(BLI),thus providing a new insight into the microcirculation of early colon tumors.AIM To observe the superficial microcirculation of colorectal adenomas using the novel magnifying colonoscope with BLI and quantitatively analyzed the changes in hemodynamic parameters.METHODS From October 2019 to January 2020,11 patients were screened for colon adenomas with the novel high-resolution magnification endoscope with BLI.Video images were recorded and processed with Adobe Premiere,Adobe Photoshop and Image-pro Plus software.Four microcirculation parameters:Microcirculation vessel density(MVD),mean vessel width(MVW)with width standard deviation(WSD),and blood flow velocity(BFV),were calculated for adenomas and the surrounding normal mucosa.RESULTS A total of 16 adenomas were identified.Compared with the normal surrounding mucosa,the superficial vessel density in the adenomas was decreased(MVD:0.95±0.18 vs 1.17±0.28μm/μm2,P<0.05).MVW(5.11±1.19 vs 4.16±0.76μm,P<0.05)and WSD(11.94±3.44 vs 9.04±3.74,P<0.05)were both increased.BFV slowed in the adenomas(709.74±213.28 vs 1256.51±383.31μm/s,P<0.05).CONCLUSION The novel high-resolution magnification endoscope with BLI can be used for in vivo study of adenoma superficial microcirculation.Superficial vessel density was decreased,more irregular,with slower blood flow. 展开更多
关键词 ADENOMA MICROCIRCULATION high-resolution magnification endoscopy Blue laser imaging
下载PDF
Use of high-resolution X-ray computed tomography and 3D image analysis to quantify mineral dissemination and pore space in oxide copper ore particles 被引量:8
5
作者 Bao-hua Yang Ai-xiang Wu +2 位作者 Guillermo A.Narsilio Xiu-xiu Miao Shu-yue Wu 《International Journal of Minerals,Metallurgy and Materials》 SCIE EI CAS CSCD 2017年第9期965-973,共9页
Mineral dissemination and pore space distribution in ore particles are important features that influence heap leaching performance. To quantify the mineral dissemination and pore space distribution of an ore particle,... Mineral dissemination and pore space distribution in ore particles are important features that influence heap leaching performance. To quantify the mineral dissemination and pore space distribution of an ore particle, a cylindrical copper oxide ore sample (I center dot 4.6 mm x 5.6 mm) was scanned using high-resolution X-ray computed tomography (HRXCT), a nondestructive imaging technology, at a spatial resolution of 4.85 mu m. Combined with three-dimensional (3D) image analysis techniques, the main mineral phases and pore space were segmented and the volume fraction of each phase was calculated. In addition, the mass fraction of each mineral phase was estimated and the result was validated with that obtained using traditional techniques. Furthermore, the pore phase features, including the pore size distribution, pore surface area, pore fractal dimension, pore centerline, and the pore connectivity, were investigated quantitatively. The pore space analysis results indicate that the pore size distribution closely fits a log-normal distribution and that the pore space morphology is complicated, with a large surface area and low connectivity. This study demonstrates that the combination of HRXCT and 3D image analysis is an effective tool for acquiring 3D mineralogical and pore structural data. 展开更多
关键词 high-resolution X-ray computed tomography 3D image analysis ore particles mineral dissemination pore space
下载PDF
Few-Shot Object Detection Based on the Transformer and High-Resolution Network 被引量:1
6
作者 Dengyong Zhang Huaijian Pu +2 位作者 Feng Li Xiangling Ding Victor S.Sheng 《Computers, Materials & Continua》 SCIE EI 2023年第2期3439-3454,共16页
Now object detection based on deep learning tries different strategies.It uses fewer data training networks to achieve the effect of large dataset training.However,the existing methods usually do not achieve the balan... Now object detection based on deep learning tries different strategies.It uses fewer data training networks to achieve the effect of large dataset training.However,the existing methods usually do not achieve the balance between network parameters and training data.It makes the information provided by a small amount of picture data insufficient to optimize model parameters,resulting in unsatisfactory detection results.To improve the accuracy of few shot object detection,this paper proposes a network based on the transformer and high-resolution feature extraction(THR).High-resolution feature extractionmaintains the resolution representation of the image.Channels and spatial attention are used to make the network focus on features that are more useful to the object.In addition,the recently popular transformer is used to fuse the features of the existing object.This compensates for the previous network failure by making full use of existing object features.Experiments on the Pascal VOC and MS-COCO datasets prove that the THR network has achieved better results than previous mainstream few shot object detection. 展开更多
关键词 Object detection few shot object detection TRANSFORMER high-resolution
下载PDF
Evaluation of Tianji and ECMWF high-resolution precipitation forecasts for extreme rainfall event in Henan in July 2021 被引量:1
7
作者 Wen-tao Li Jia-peng Zhang +1 位作者 Ruo-chen Sun Qingyun Duan 《Water Science and Engineering》 EI CAS CSCD 2023年第2期122-131,共10页
The extreme rainfall event of July 17 to 22, 2021 in Henan Province, China, led to severe urban waterlogging and flood disasters. This study investigated the performance of high-resolution weather forecasts in predict... The extreme rainfall event of July 17 to 22, 2021 in Henan Province, China, led to severe urban waterlogging and flood disasters. This study investigated the performance of high-resolution weather forecasts in predicting this extreme event and the feasibility of weather forecast-based hydrological forecasts. To achieve this goal, high-resolution precipitation forecasts from the Tianji weather system and the forecast system of the European Centre for Medium-Range Weather Forecasts (ECMWF) were evaluated with the spatial verification metrics of structure, amplitude, and location. The results showed that Tianji weather forecasts accurately predicted the amplitude of 12-h accumulated precipitation with a lead time of 12 h. The location and structure of the rainfall areas in Tianji forecasts were closer to the observations than ECMWF forecasts. Tianji hourly precipitation forecasts were also more accurate than ECMWF hourly forecasts, especially at lead times shorter than 8 h. The precipitation forecasts were used as the inputs to a hydrological model to evaluate their hydrological applications. The results showed that the runoff forecasts driven by Tianji weather forecasts could effectively predict the extreme flood event. The runoff forecasts driven by Tianji forecasts were more accurate than those driven by ECMWF forecasts in terms of amplitude and location. This study demonstrates that high-resolution weather forecasts and corresponding hydrological forecasts can provide valuable information in advance for disaster warnings and leave time for people to act on the event. The results encourage further hydrological applications of high-resolution weather forecasts, such as Tianji weather forecasts, in the future. 展开更多
关键词 Extreme precipitation high-resolution weather forecast EVALUATION Flood forecasting Spatial forecast verification
下载PDF
High-resolution Rayleigh wave phase velocity maps from ambient noise tomography in North China 被引量:6
8
作者 Jiatie Pan Institute of Geophysics, China Earthquake Administration, Beijing 100081, China 《Earthquake Science》 CSCD 2012年第3期241-251,共11页
We presented high-resolution Rayleigh wave phase velocity maps at periods ranging from 5 s to 30 s in the northeast part of the North China Craton (NNCC). Continuous time-series of vertical component between October 2... We presented high-resolution Rayleigh wave phase velocity maps at periods ranging from 5 s to 30 s in the northeast part of the North China Craton (NNCC). Continuous time-series of vertical component between October 2006 and December 2008, recorded by 187 broadband stations temporarily deployed in the NNCC region, have been cross-correlated to obtain estimated fundamental mode Rayleigh wave Green’s functions. Using the frequency and time analysis technique based on continuous wavelet transformation, we measured 3 667 Rayleigh wave phase velocity dispersion curves. High-resolution phase velocity maps at periods of 5, 10, 20 and 30 s were reconstructed with grid size 0.25°× 0.25°, which reveal lateral heterogeneity of shear wave structure in the crust and upper mantle of NNCC. For periods shorter than 10 s, the phase velocity variations are well correlated with the principal geological units in the NNCC, with low-speed anomalies corresponding to the major sedimentary basins and high-speed anomalies coinciding with the main mountain ranges. Within the period range from 20 s to 30 s, high phase velocity observed in eastern NCC is coincident with the thin crust, whereas low phase velocities imaged in central NCC is correlated to the thick crust. However, the low-velocity anomaly in the Beijing-Tianjin-Tangshan region displayed in the 20 s and 30 s phase maps may be associated with fluids. 展开更多
关键词 Rayleigh wave phase velocity ambient noise tomography wavelet transformation North China Craton
下载PDF
Tomographic reconstruction of the Earth’s magnetosheath from multiple spacecraft:a theoretical study 被引量:2
9
作者 A.M.Jorgensen TianRan Sun +4 位作者 Y.Huang L.Li R.Xu L.Dai Chi Wang 《Earth and Planetary Physics》 EI CSCD 2024年第1期204-214,共11页
Following our earlier work on tomographic reconstruction of the magnetosheath soft X-ray emissions with superposed epoch analysis of many images recorded from a single spacecraft we now explore the instantaneous recon... Following our earlier work on tomographic reconstruction of the magnetosheath soft X-ray emissions with superposed epoch analysis of many images recorded from a single spacecraft we now explore the instantaneous reconstruction of the magnetosheath and magnetopause using a few images recorded simultaneously from a few spacecraft.This work is motivated by the prospect of possibly having two or three soft X-ray imagers in space in the coming years,and that many phenomena which occur at the magnetopause boundary,such as reconnection events and pressure pulse responses,do not lend themselves as well to superposed epoch analysis.If the reconstruction is successful-which we demonstrate in this paper that it can be-this collection of imagers can be used to reconstruct the magnetosheath and magnetopause from a single image from each spacecraft,allowing for high time resolution reconstructions.In this paper we explore the reconstruction using,two,three,and four spacecraft.We show that the location of the subsolar point of the magnetopause can be determined with just two satellites,and that volume emissions of soft X-rays,and the shape of the boundary,can be reconstructed using three or more satellites. 展开更多
关键词 MAGNETOSHEATH tomography soft X-ray imaging SMILE
下载PDF
Full Scale-Aware Balanced High-Resolution Network for Multi-Person Pose Estimation
10
作者 Shaohua Li Haixiang Zhang +2 位作者 HanjieMa Jie Feng Mingfeng Jiang 《Computers, Materials & Continua》 SCIE EI 2023年第9期3379-3392,共14页
Scale variation is amajor challenge inmulti-person pose estimation.In scenes where persons are present at various distances,models tend to perform better on larger-scale persons,while the performance for smaller-scale... Scale variation is amajor challenge inmulti-person pose estimation.In scenes where persons are present at various distances,models tend to perform better on larger-scale persons,while the performance for smaller-scale persons often falls short of expectations.Therefore,effectively balancing the persons of different scales poses a significant challenge.So this paper proposes a newmulti-person pose estimation model called FSANet to improve themodel’s performance in complex scenes.Our model utilizes High-Resolution Network(HRNet)as the backbone and feeds the outputs of the last stage’s four branches into the DCB module.The dilated convolution-based(DCB)module employs a parallel structure that incorporates dilated convolutions with different rates to expand the receptive field of each branch.Subsequently,the attention operation-based(AOB)module performs attention operations at both branch and channel levels to enhance high-frequency features and reduce the influence of noise.Finally,predictions are made using the heatmap representation.The model can recognize images with diverse scales and more complex semantic information.Experimental results demonstrate that FSA Net achieves competitive results on the MSCOCO and MPII datasets,validating the effectiveness of our proposed approach. 展开更多
关键词 Computer vision high-resolution network human pose estimation
下载PDF
The Differences of Interstitial Lung Diseases in High-Resolution Computerized Tomography and Pulmonary Function Test among Different Connective Tissue Diseases, and the Correlated Factors 被引量:1
11
作者 Zhen Jiang Wenyou Pan +1 位作者 Jinhui Tao Xiangpei Li 《Open Journal of Rheumatology and Autoimmune Diseases》 2018年第2期53-65,共13页
Objective. To study the difference of interstitial lung diseases (ILDs) in high-resolution computerized tomography and pulmonary function test among different connective tissue diseases (CTDs). Methods. 209 patients w... Objective. To study the difference of interstitial lung diseases (ILDs) in high-resolution computerized tomography and pulmonary function test among different connective tissue diseases (CTDs). Methods. 209 patients with different CTDs were recruited and underwent lung HRCT and PFT. Eerythrocyte sedimentation rate (ESR), C-reactive protein (CRP), serum ferritin (SF), anti-SSA, and so on were tested. Based on HRCT, a patient was classified into ILD group (CTD+ILD) or non-ILD group (CTD-ILD). HRCT, PFT, and laboratory markers were compared according to CTDs and CTD-associated ILDs. Results. The incidences of ILD were 79.6%, 82.0%, 89.7%, and 97.1% respectively for Rheumatoid arthritis (RA), primary Sjogren’s symptom (pSS), dermatomyositis/polymyositis (DM/PM), and systemic sclerosis (SSc) groups. RA and pSS patients exhibited more nodules, patching, ground-glass opacity, and cord shadow foci in HRCT, DM/PM and SSc patients exhibited more reticular opacity and honeycombing foci. RA and pSS patients exhibited more obstructive ventilatory disorder, small airway dysfunction and emphysema in PFT, and DM/PM and SSc patients exhibited more restrictive ventilatory disorder, mixed ventilatory disorder. ESR, CRP and SF were significantly higher in total CTD+ILD group than in total CTD-ILD group (P = 0.047, 0.006, 0.004, respectively), and higher in different CTD+ ILD groups than in comparable CTD-ILD groups (P = 0.049, 0.048, and 0.023, pSS+ILD, SSc+ILD and RA+ILD compared to pSS-ILD, SSc-ILD and RA-ILD, respectively for ESR, CRP, SF). The positive rate of anti-SSA was significantly higher in DM/PM+ILD group than in DM/PM-ILD group (P = 0.025). Conclusions. The manifestations and incidences of ILDs differ among different CTDs in HRCT and PFT, and inflammation and anti-SSA are positively correlated with ILDs in different CTDs, which provide important evidences for judging disease condition and prognosis. 展开更多
关键词 CONNECTIVE Tissue Diseases INTERSTITIAL lung Disease high-resolution COMPUTERIZED tomography PULMONARY Function Test Inflammation
下载PDF
Multilocular thymic cysts can be easily misdiagnosed as malignant tumor on computer tomography:A case report 被引量:2
12
作者 Jun Sun Qing-Ning Yang +5 位作者 Yi Guo Ping Zeng Long-Yan Ma Ling-Wen Kong Bo-Ying Zhao Chuan-Ming Li 《World Journal of Clinical Cases》 SCIE 2024年第8期1474-1480,共7页
BACKGROUND Multilocular thymic cyst(MTC)is a rare mediastinal lesion which is considered to occur in the process of acquired inflammation.It is usually characterized by well-defined cystic density and is filled with t... BACKGROUND Multilocular thymic cyst(MTC)is a rare mediastinal lesion which is considered to occur in the process of acquired inflammation.It is usually characterized by well-defined cystic density and is filled with transparent liquid.CASE SUMMARY We report on a 39-year-old male with a cystic-solid mass in the anterior mediastinum.Computer tomography(CT)imaging showed that the mass was irregular with unclear boundaries.After injection of contrast agent,there was a slight enhancement of stripes and nodules.According to CT findings,it was diagnosed as thymic cancer.CONCLUSION After surgery,MTC accompanied by bleeding and infection was confirmed by pathological examination.The main lesson of this case was that malignant thymic tumor and MTC of the anterior mediastinum sometimes exhibit similar CT findings.Caution is necessary in clinical work to avoid misdiagnosis. 展开更多
关键词 Multilocular thymic cyst Computer tomography MISDIAGNOSIS HEMORRHAGE INFECTION Case report
下载PDF
High-resolution seismic tomography of the upper crust in the source region of the April 20,2013 Lushan earthquake and its seismotectonic implications 被引量:1
13
作者 Baofeng Tian Zhiwei Li +1 位作者 Sha Liu Jiansi Yang 《Earthquake Science》 2013年第3期213-221,共9页
Both P- and S-wave arrivals were collected for imaging upper crustal structures in the source region of the April 20, 2013 Lushan earthquake. High-resolution, three- dimensional P and S velocity models were constructe... Both P- and S-wave arrivals were collected for imaging upper crustal structures in the source region of the April 20, 2013 Lushan earthquake. High-resolution, three- dimensional P and S velocity models were constructed by travel-time tomography. Moreover, more than 3700 after- shocks of the Lushan earthquake were relocated via a grid search method. The P- and S-wave velocity images of the upper crust show largely similar characters, with high and low velocity anomalies, which mark the presence of sig- nificant lateral and vertical heterogeneity at the source region of the Lushan earthquake. The characteristics of the velocity anomalies also reflect the associated surface geo- logical tectonics in this region. The distributions of high velocity anomalies of both P- and S-waves to 18 km depth are consistent with the distributions of relocated after- shocks, suggesting that most of the ruptures were localized inside the high velocity region. In contrast, low P and S velocities were found in the surrounding regions without aftershocks, especially in the region to the northeast of the Lushan earthquake. For the relocated aftershocks of the Lushan earthquake from this study, we found that mostaftershocks were concentrated in a zone of about 40 km long and 20 km wide, and were located in the hanging wall of Dayi-Mingshan fault. The focal depths of aftershocks increase from the southeast to the northwest region in the direction perpendicular to the fault strike, suggesting that the fault ruptured at an approximate dip angle of 45°. The main depths of the aftershocks in the northwest of the main shock are significantly shallower than expected, revealing the different seismogenic conditions in the source region. 展开更多
关键词 Lushan earthquake tomography Velocity structure Upper crust
下载PDF
High-resolution polarization-sensitive optical coherence tomography and optical coherence tomography angiography for zebrafish skin imaging 被引量:2
14
作者 Di Yang Zhuoqun Yuan +2 位作者 Zihan Yang Muyun Hu Yanmei Liang 《Journal of Innovative Optical Health Sciences》 SCIE EI CAS 2021年第6期131-144,共14页
Zebrafish is an important animal model,which is used to study development,pathology,and genetic research.The zebrafish skin model is widely used in cutaneous research,and angiogenesis is critical for cutaneous wound h... Zebrafish is an important animal model,which is used to study development,pathology,and genetic research.The zebrafish skin model is widely used in cutaneous research,and angiogenesis is critical for cutaneous wound healing.However,limited by the penetration depth,the available optical methods are difficult to describe the internal skin structure and the connection of blood vessels between the skin and subcutaneous tissue.By a homemade high-resolution polarization-sensitive optical coherence tomography(PS-OCT)system,we imaged the polarization contrast of zebrafish skin and the zebrafish skin vasculature with optical coherence tomography angiography(OCTA).Based on these OCT images,the spatial distribution of the zebrafish skin vasculature was described.Furthermore,we monitored the healing process of zebrafish cutaneous wounds.We think the high-resolution PS-OCT system will be a promising tool in studying cutaneous models of zebrafish. 展开更多
关键词 Polarization-sensitive optical coherence tomography optical coherence tomography angiography ZEBRAFISH skin vasculature
下载PDF
High-Resolution Mass Spectroscopy for Revealing the Charge Storage Mechanism in Batteries: Oxamide Materials as an Example
15
作者 Chenyang Zhang Yuan Chen +7 位作者 Kun Fan Guoqun Zhang Jincheng Zou Huichao Dai Yanbo Gao Xiaobo Wang Minglei Mao Chengliang Wang 《Energy & Environmental Materials》 SCIE EI CAS CSCD 2023年第4期195-202,共8页
The pursuit of high-performance electrode materials is highly desired to meet the demand of batteries with high energy and power density.However,a deep understanding of the charge storage mechanism is always challengi... The pursuit of high-performance electrode materials is highly desired to meet the demand of batteries with high energy and power density.However,a deep understanding of the charge storage mechanism is always challenging,which limits the development of advanced electrode materials.Herein,high-resolution mass spectroscopy(HR-MS)is employed to detect the evolution of organic electrode materials during the redox process and reveal the charge storage mechanism,by using small molecular oxamides as an example,which have ortho-carbonyls and are therefore potential electrochemical active materials for batteries.The HR-MS results adequately proved that the oxamides could reversibly store lithium ions in the voltage window of 1.5–3.8 V.Upon deeper reduction,the oxamides would decompose due to the cleavage of the C–N bonds in oxamide structures,which could be proved by the fragments detected by HR-MS,^(1)H NMR,and the generation of NH_(3)after the reduction of oxamide by Li.This work provides a strategy to deeply understand the charge storage mechanism of organic electrode materials and will stimulate the further development of characterization techniques to reveal the charge storage mechanism for developing high-performance electrode materials. 展开更多
关键词 charge storage mechanism high-resolution mass spectroscopy organic batteries organic electrodes oxamides
下载PDF
High-resolution computed tomography in patients with atypical 'cardiac' chest pain: a study investigating patients at 10-year cardiovascular risks defined by the Framingham and PROCAM scores 被引量:1
16
作者 Choon Kiat ANG Alan Yean Yip FONG +6 位作者 Sze Piaw CHIN Tiong Kiam ONG Seyfarth M Tobias Chee Khoon LIEW Rapaee ANNUAR Houng Bang LIEW Kui Hian SIM 《Journal of Geriatric Cardiology》 SCIE CAS CSCD 2006年第1期17-21,共5页
Background and objective Atypical 'cardiac' chest pain (ACCP) is not usually caused by myocardial ischaemia. Current noninvasive investigations for these symptoms are not yet as accurate as invasive coronary a... Background and objective Atypical 'cardiac' chest pain (ACCP) is not usually caused by myocardial ischaemia. Current noninvasive investigations for these symptoms are not yet as accurate as invasive coronary angiography. The latest 64-row multi-detector computed tomography (MDCT) technology is non-invasive, has high specificity and negative predictive values for the detection of significant coronary disease. Our aim was to investigate if this modality can provide more information in the assessment of outpatients with ACCP in addition to established cardiovascular risk scores. Methods Seventy consecutive patients presenting to the outpatient clinic with ACCP underwent 64-row MDCT scan of the coronary arteries. They were categorized into low, medium or high risk groups based upon the Framingham and PROCAM scores. We defined a clinically abnormal MDCT scan as coronary stenosis =50% or calcium score >400 Agatston. Results Fifty-three (75.7%) patients did not have clinically abnormal scans. Framingham score classified 43 patients as low-risk while PROCAM classified 59 patients as low-risk. MDCT scans were abnormal for 18.6% and 22.0% of the respective low-risk group of patients. For patients with medium-to-high risk, 33.3% and 36.4% of Framingham and PROCAM patient groups respectively had abnormal MDCT scans. Conclusion MDCT adds valuable information in the assessment of patients with ACCP by identifying a significant proportion of patients categorized as low-risk to have underlying significant coronary stenosis and coronary calcification by established cardiovascular risk scores. 展开更多
关键词 multi-detector computed tomography ATYPICAL 'cardiac' CHEST pain coronary artery disease risk stratification
下载PDF
Lymphatic plastic bronchitis and primary chylothorax: A study based on computed tomography lymphangiography 被引量:1
17
作者 Xing-Peng Li Yan Zhang +4 位作者 Xiao-Li Sun Kun Hao Meng-Ke Liu Qi Hao Ren-Gui Wang 《World Journal of Clinical Cases》 SCIE 2024年第14期2350-2358,共9页
BACKGROUND This study presents an evaluation of the computed tomography lymphangio-graphy(CTL)features of lymphatic plastic bronchitis(PB)and primary chylotho-rax to improve the diagnostic accuracy for these two disea... BACKGROUND This study presents an evaluation of the computed tomography lymphangio-graphy(CTL)features of lymphatic plastic bronchitis(PB)and primary chylotho-rax to improve the diagnostic accuracy for these two diseases.AIM To improve the diagnosis of lymphatic PB or primary chylothorax,a retrospective analysis of the clinical features and CTL characteristics of 71 patients diagnosed with lymphatic PB or primary chylothorax was performed.METHODS The clinical and CTL data of 71 patients(20 with lymphatic PB,41 with primary chylothorax,and 10 with lymphatic PB with primary chylothorax)were collected retrospectively.CTL was performed in all patients.The clinical manifestations,CTL findings,and conventional chest CT findings of the three groups of patients were compared.The chi-square test or Fisher's exact test was used to compare the differences among the three groups.A difference was considered to be statistically significant when P<0.05.RESULTS(1)The percentages of abnormal contrast medium deposits on CTL in the three groups were as follows:Thoracic duct outlet in 14(70.0%),33(80.5%)and 8(80.0%)patients;peritracheal region in 18(90.0%),15(36.6%)and 8(80.0%)patients;pleura in 6(30.0%),33(80.5%)and 9(90.0%)patients;pericardium in 6(30.0%),6(14.6%)and 4(40.0%)patients;and hilum in 16(80.0%),11(26.8%)and 7(70.0%)patients;and(2)the abnormalities on conven-tional chest CT in the three groups were as follows:Ground-glass opacity in 19(95.0%),18(43.9%)and 8(80.0%)patients;atelectasis in 4(20.0%),26(63.4%)and 7(70.0%)patients;interlobular septal thickening in 12(60.0%),11(26.8%)and 3(30.0%)patients;bronchovascular bundle thickening in 14(70.0%),6(14.6%)and 4(40.0%)patients;localized mediastinal changes in 14(70.0%),14(34.1%),and 7(70.0%)patients;diffuse mediastinal changes in 6(30.0%),5(12.2%),and 3(30.0%)patients;cystic lesions in the axilla in 2(10.0%),6(14.6%),and 2(20.0%)patients;and cystic lesions in the chest wall in 0(0%),2(4.9%),and 2(4.9%)patients.CONCLUSION CTL is well suited to clarify the characteristics of lymphatic PB and primary chylothorax.This method is an excellent tool for diagnosing these two diseases. 展开更多
关键词 LYMPHATIC Plastic bronchitis Primary chylothorax Direct lymphangiography Computed tomography lymphangiography
下载PDF
High-resolution computed tomography findings in humoral primary immunodeficiencies and correlation with pulmonary function tests 被引量:1
18
作者 Lorenzo Cereser Marco De Carli +3 位作者 Paola d'Angelo Elisa Zanelli Chiara Zuiani Rossano Girometti 《World Journal of Radiology》 CAS 2018年第11期172-183,共12页
AIM To compare high-resolution computed tomography(HRCT) findings between humoral primary immunodeficiencies(hPIDs) subtypes; to correlate these findings to pulmonary function tests(PFTs).METHODS We retrospectively id... AIM To compare high-resolution computed tomography(HRCT) findings between humoral primary immunodeficiencies(hPIDs) subtypes; to correlate these findings to pulmonary function tests(PFTs).METHODS We retrospectively identified 52 consecutive adult patients with hPIDs who underwent 64-row HRCT and PFTs at the time of diagnosis. On a per-patient basis, an experienced radiologist recorded airway abnormalities(bronchiectasis,airway wall thickening, mucus plugging, tree-in-bud, and air-trapping) and parenchymal-interstitial abnormalities(consolidations, ground-glass opacities,linear and/or irregular opacities, nodules, and bullae/cysts) found on HRCT.The chi-square test was performed to compare the prevalence of each abnormality among patients with different subtypes of hPIDs. Overall logistic regression analysis was performed to assess whether HRCT findings predicted obstructive and/or restrictive PFTs results(absent-to-mild vs moderate-tosevere).RESULTS Thirty-eight of the 52 patients with hPIDs showed common variable immunodeficiency disorders(CVID), while the remaining 14 had CVID-like conditions(i.e., 11 had isolated IgG subclass deficiencies and 3 had selective IgA deficiencies). The prevalence of most HRCT abnormalities was not significantly different between CVID and CVID-like patients(P > 0.05), except for linear and/or irregular opacities(prevalence of 31.6% in the CVID group and 0 in the CVID-like group; P = 0.0427). Airway wall thickening was the most frequent HRCT abnormality found in both CVID and CVID-like patients(71% of cases in both groups). The presence of tree-in-bud abnormalities was an independent predictor of moderate-to-severe obstructive defects at PFTs(Odds Ratio, OR, of 18.75, P < 0.05), while the presence of linear and/or irregular opacities was an independent predictor of restrictive defects at PFTs(OR = 13.00; P < 0.05).CONCLUSION CVID and CVID-like patients showed similar HRCT findings. Tree-in-bud and linear and/or irregular opacities predicted higher risks of, respectively,obstructive and restrictive defects at PFTs. 展开更多
关键词 BRONCHIECTASIS MULTIDETECTOR computed tomography Common variable IMMUNODEFICIENCY IMMUNOLOGIC deficiency SYNDROMES Respiratory function tests
下载PDF
A systematic printability study of direct ink writing towards high-resolution rapid manufacturing
19
作者 Qingyang Zheng Bin Xie +1 位作者 Zhoulong Xu Hao Wu 《International Journal of Extreme Manufacturing》 SCIE EI CAS CSCD 2023年第3期500-517,共18页
Direct ink writing(DIW)holds enormous potential in fabricating multiscale and multi-functional architectures by virtue of its wide range of printable materials,simple operation,and ease of rapid prototyping.Although i... Direct ink writing(DIW)holds enormous potential in fabricating multiscale and multi-functional architectures by virtue of its wide range of printable materials,simple operation,and ease of rapid prototyping.Although it is well known that ink rheology and processing parameters have a direct impact on the resolution and shape of the printed objects,the underlying mechanisms of these key factors on the printability and quality of DIW technique remain poorly understood.To tackle this issue,we systematically analyzed the printability and quality through extrusion mechanism modeling and experimental validating.Hybrid non-Newtonian fluid inks were first prepared,and their rheological properties were measured.Then,finite element analysis of the whole DIW process was conducted to reveal the flow dynamics of these inks.The obtained optimal process parameters(ink rheology,applied pressure,printing speed,etc)were also validated by experiments where high-resolution(<100μm)patterns were fabricated rapidly(>70 mm s^(-1)).Finally,as a process research demonstration,we printed a series of microstructures and circuit systems with hybrid inks and silver inks,showing the suitability of the printable process parameters.This study provides a strong quantitative illustration of the use of DIW for the high-speed preparation of high-resolution,high-precision samples. 展开更多
关键词 direct ink writing extrusion mechanism modelling computational fluid dynamic(CFD) printability process parameters high-resolution printing
下载PDF
On High-Resolution Entropy-Consistent Flux with Slope Limiter for Hyperbolic Conservation Laws
20
作者 Xuan Ren Jianhu Feng +2 位作者 Supei Zheng Xiaohan Cheng Yang Li 《Communications on Applied Mathematics and Computation》 EI 2023年第4期1616-1643,共28页
This paper proposes a new version of the high-resolution entropy-consistent(EC-Limited)flux for hyperbolic conservation laws based on a new minmod-type slope limiter.Firstly,we identify the numerical entropy productio... This paper proposes a new version of the high-resolution entropy-consistent(EC-Limited)flux for hyperbolic conservation laws based on a new minmod-type slope limiter.Firstly,we identify the numerical entropy production,a third-order differential term deduced from the previous work of Ismail and Roe[11].The corresponding dissipation term is added to the original Roe flux to achieve entropy consistency.The new,resultant entropy-consistent(EC)flux has a general and explicit analytical form without any corrective factor,making it easy to compute and a less-expensive method.The inequality constraints are imposed on the standard piece-wise quadratic reconstruction to enforce the pointwise values of bounded-type numerical solutions.We design the new minmod slope limiter as combining two separate limiters for left and right states.We propose the EC-Limited flux by adding this reconstruction data method to the primitive variables rather than to the conservative variables of the EC flux to preserve the equilibrium of the primitive variables.These resulting fluxes are easily applied to general hyperbolic conservation laws while having attractive features:entropy-stable,robust,and non-oscillatory.To illustrate the potential of these proposed fluxes,we show the applications to the Burgers equation and the Euler equations. 展开更多
关键词 Hyperbolic conservation laws Entropy production Entropy-consistent(EC)flux Slope limiter high-resolution entropy-consistent(EC-Limited)flux
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部