This paper proposed the scheme of transmission lines distance protection based on differential equation algorithms (DEA) and Hilbert-Huang transform (HHT). The measured impedance based on EDA is affected by various fa...This paper proposed the scheme of transmission lines distance protection based on differential equation algorithms (DEA) and Hilbert-Huang transform (HHT). The measured impedance based on EDA is affected by various factors, such as the distributed capacitance, the transient response characteristics of current transformer and voltage transformer, etc. In order to overcome this problem, the proposed scheme applies HHT to improve the apparent impedance estimated by DEA. Empirical mode decomposition (EMD) is used to decompose the data set from DEA into the intrinsic mode functions (IMF) and the residue. This residue has monotonic trend and is used to evaluate the impedance of faulty line. Simulation results show that the proposed scheme improves significantly the accuracy of the estimated impedance.展开更多
According to the deficiency of Chord algorithm supporting single keyword query only, a P2P framework-HilbertChord by combining the Hilbert curve and Chord is proposed for managing grid service resources, which support...According to the deficiency of Chord algorithm supporting single keyword query only, a P2P framework-HilbertChord by combining the Hilbert curve and Chord is proposed for managing grid service resources, which supports DHT-based multi-keyword query and approximate query by means of Hilbert index to improve resources searching ability. Experiments show that HilbertChord has better efficiency and scalability for managing service resources under the large scale P2P environment with higher density of services.展开更多
为了检测触电时刻剩余电流中生物体触电支路电流信号的难题,应用Hilbert-Huang变换方法,确定了生物触电时剩余电流的固有模态函数中相关系数最大的IMF分量的局部幅值达34.02 m A,且与原信号相关性系数达到0.99,同时剩余电流与触电电流...为了检测触电时刻剩余电流中生物体触电支路电流信号的难题,应用Hilbert-Huang变换方法,确定了生物触电时剩余电流的固有模态函数中相关系数最大的IMF分量的局部幅值达34.02 m A,且与原信号相关性系数达到0.99,同时剩余电流与触电电流暂态过程频谱特性具有相似变化规律。以此为基础,应用生物电流信号高频IMF分量幅值的突变特征,作为触电故障时刻确定判据,建立生物触电故障时刻判定方法,实际数据的仿真处理正确率为94.17%;筛选剩余电流分解的相关性较高的有限个数的低频固有模态IMF分量,应用逐步多元线性回归方法,提出基于剩余电流固有模态分量的生物触电支路电流幅值检测方法,仿真试验结果的平均相对误差值5.46%,具有良好的适应性和实用性,为研发基于生物体触电电流而动作的剩余电流保护装置提供参考。展开更多
文摘This paper proposed the scheme of transmission lines distance protection based on differential equation algorithms (DEA) and Hilbert-Huang transform (HHT). The measured impedance based on EDA is affected by various factors, such as the distributed capacitance, the transient response characteristics of current transformer and voltage transformer, etc. In order to overcome this problem, the proposed scheme applies HHT to improve the apparent impedance estimated by DEA. Empirical mode decomposition (EMD) is used to decompose the data set from DEA into the intrinsic mode functions (IMF) and the residue. This residue has monotonic trend and is used to evaluate the impedance of faulty line. Simulation results show that the proposed scheme improves significantly the accuracy of the estimated impedance.
文摘According to the deficiency of Chord algorithm supporting single keyword query only, a P2P framework-HilbertChord by combining the Hilbert curve and Chord is proposed for managing grid service resources, which supports DHT-based multi-keyword query and approximate query by means of Hilbert index to improve resources searching ability. Experiments show that HilbertChord has better efficiency and scalability for managing service resources under the large scale P2P environment with higher density of services.
文摘为了检测触电时刻剩余电流中生物体触电支路电流信号的难题,应用Hilbert-Huang变换方法,确定了生物触电时剩余电流的固有模态函数中相关系数最大的IMF分量的局部幅值达34.02 m A,且与原信号相关性系数达到0.99,同时剩余电流与触电电流暂态过程频谱特性具有相似变化规律。以此为基础,应用生物电流信号高频IMF分量幅值的突变特征,作为触电故障时刻确定判据,建立生物触电故障时刻判定方法,实际数据的仿真处理正确率为94.17%;筛选剩余电流分解的相关性较高的有限个数的低频固有模态IMF分量,应用逐步多元线性回归方法,提出基于剩余电流固有模态分量的生物触电支路电流幅值检测方法,仿真试验结果的平均相对误差值5.46%,具有良好的适应性和实用性,为研发基于生物体触电电流而动作的剩余电流保护装置提供参考。