[Objectives] To establish a method for determining the content of chlorogenic acid in Wuli Huichun Wan. [Methods] The content of chlorogenic acid in Wuli Huichun Wan was determined by high performance liquid chromatog...[Objectives] To establish a method for determining the content of chlorogenic acid in Wuli Huichun Wan. [Methods] The content of chlorogenic acid in Wuli Huichun Wan was determined by high performance liquid chromatography( HPLC) combined with Agilent Eclipse Plus C18 column( 4. 6 mm × 250 mm,5 μm),in mobile phase of 0. 4% phosphoric acid solution-acetonitrile( 12∶ 88) at flow rate of1. 0 m L/min,and detection wavelength of 327 nm. [Results] The linearity of chlorogenic acid in the range of 4-48 μg injection was good( r = 1); the average recovery rate was 99. 61% and the RSD was 0. 98%. [Conclusions] The established method is simple and accurate and has high reproducibility,thus can be used as quality control method for Wuli Huichun Wan.展开更多
文摘[Objectives] To establish a method for determining the content of chlorogenic acid in Wuli Huichun Wan. [Methods] The content of chlorogenic acid in Wuli Huichun Wan was determined by high performance liquid chromatography( HPLC) combined with Agilent Eclipse Plus C18 column( 4. 6 mm × 250 mm,5 μm),in mobile phase of 0. 4% phosphoric acid solution-acetonitrile( 12∶ 88) at flow rate of1. 0 m L/min,and detection wavelength of 327 nm. [Results] The linearity of chlorogenic acid in the range of 4-48 μg injection was good( r = 1); the average recovery rate was 99. 61% and the RSD was 0. 98%. [Conclusions] The established method is simple and accurate and has high reproducibility,thus can be used as quality control method for Wuli Huichun Wan.