In recent years,the hybrid AC-DC microgrid has been well accepted as it combines the advantages of both AC and DC systems.As the microgrid contains both DC sub-grids and AC sub-grids,interlinking DC-AC converters are ...In recent years,the hybrid AC-DC microgrid has been well accepted as it combines the advantages of both AC and DC systems.As the microgrid contains both DC sub-grids and AC sub-grids,interlinking DC-AC converters are essential.Meanwhile,considering the nonlinear AC loads may deteriorate the voltage quality of the AC bus,embedding an ancillary harmonic compensation function to the interlinking converters is promising.However,the conventional harmonic control methods used for active power filters(APFs)may not be suitable for the interlinking converters due to the main purpose of it is to exchange real and reactive power between the DC and AC sub-grids.The switching frequency is preferred to be lower than the APFs when the capacity of the microgrid is large.At low switching frequency,harmonic compensation performance or even the system stability may be affected.In this paper,a harmonic compensation approach suitable for hybrid AC-DC interlinking converters at low switching frequency is proposed.Through feeding the PWM reference signal with the harmonic compensation component directly to avoid the multi-loop control path of the fundamental component,the proposed method can achieve the effective harmonics compensation without being limited by the closed-loop control bandwidth.The proposed method,modeling approaches,stability analysis,as well as detailed virtual impedance design are presented.Experimental verification is also provided.展开更多
To reduce the comprehensive costs of the construction and operation of microgrids and to minimize the power fluctuations caused by randomness and intermittency in distributed generation,a double-layer optimizing confi...To reduce the comprehensive costs of the construction and operation of microgrids and to minimize the power fluctuations caused by randomness and intermittency in distributed generation,a double-layer optimizing configuration method of hybrid energy storage microgrid based on improved grey wolf optimization(IGWO)is proposed.Firstly,building a microgrid system containing a wind-solar power station and electric-hydrogen coupling hybrid energy storage system.Secondly,the minimum comprehensive cost of the construction and operation of the microgrid is taken as the outer objective function,and the minimum peak-to-valley of the microgrid’s daily output is taken as the inner objective function.By iterating through the outer and inner layers,the system improves operational stability while achieving economic configuration.Then,using the energy-self-smoothness of the microgrid as the evaluation index,a double-layer optimizing configuration method of the microgrid is constructed.Finally,to improve the disadvantages of grey wolf optimization(GWO),such as slow convergence in the later period and easy falling into local optima,by introducing the convergence factor nonlinear adjustment strategy and Cauchy mutation operator,an IGWO with excellent global performance is proposed.After testing with the typical test functions,the superiority of IGWO is verified.Next,using IGWO to solve the double-layer model.The case analysis shows that compared to GWO and particle swarm optimization(PSO),the IGWO reduced the comprehensive cost by 15.6%and 18.8%,respectively.Therefore,the proposed double-layer optimizationmethod of capacity configuration ofmicrogrid with wind-solar-hybrid energy storage based on IGWO could effectively improve the independence and stability of the microgrid and significantly reduce the comprehensive cost.展开更多
Hybrid Petri nets(HPNs) are widely used to describe and analyze various industrial hybrid systems that have both discrete-event and continuous discrete-time behaviors. Recently,many researchers attempt to utilize them...Hybrid Petri nets(HPNs) are widely used to describe and analyze various industrial hybrid systems that have both discrete-event and continuous discrete-time behaviors. Recently,many researchers attempt to utilize them to characterize power and energy systems. This work proposes to adopt an HPN to model and analyze a microgrid that consists of green energy sources. A reachability graph for such a model is generated and used to analyze the system properties.展开更多
This paper presents a method for optimal sizing of an off-grid hybrid microgrid (MG) system in order to achieve a certain load demand. The hybrid MG is made of a solar photovoltaic (PV) system, wind turbine (TW) and e...This paper presents a method for optimal sizing of an off-grid hybrid microgrid (MG) system in order to achieve a certain load demand. The hybrid MG is made of a solar photovoltaic (PV) system, wind turbine (TW) and energy storage system (ESS). The reliability of the MG system is modeled based on the loss of power supply probability (SPSP). For optimization, an enhanced Genetic Algorithm (GA) is used to minimize the total cost of the system over a 20-year period, while satisfying some reliability and operation constraints. A case study addressing optimal sizing of an off-grid hybrid microgrid in Nigeria is discussed. The result is compared with results obtained from the Brute Force and standard GA methods.展开更多
Distributed collaborative control strategies for microgrids often use periodic time to trigger communication,which is likely to enhance the burden of communication and increase the frequency of controller updates,lead...Distributed collaborative control strategies for microgrids often use periodic time to trigger communication,which is likely to enhance the burden of communication and increase the frequency of controller updates,leading to greater waste of communication resources.In response to this problem,a distributed cooperative control strategy triggered by an adaptive event is proposed.By introducing an adaptive event triggering mechanism in the distributed controller,the triggering parameters are dynamically adjusted so that the distributed controller can communicate only at a certain time,the communication pressure is reduced,and the DC bus voltage deviation is effectively reduced,at the same time,the accuracy of power distribution is improved.The MATLAB/Simulink modeling and simulation results prove the correctness and effectiveness of the proposed control strategy.展开更多
Small-hydro power station is often used in remote areas beside a river,but it doesn't match electricity demand so well,especially in dry seasons. A photovoltaic (PV) system with battery is a suitable option to com...Small-hydro power station is often used in remote areas beside a river,but it doesn't match electricity demand so well,especially in dry seasons. A photovoltaic (PV) system with battery is a suitable option to complement the electricity gap. In this paper,a new structure of megawatt-class PV system integrating battery at DC-bus (DC: direct current) is proposed to be used in hydro/PV hybrid power system,and 4 main designing considerations and several key equipments are discussed. In 2011,a 2 MWp PV station with the proposed structure was built up in Yushu,China. From stability analysis,the station shows a strong stability under load cut-in/off and solar irradiance's fluctuation.展开更多
Present-day power conversion and conditioning systems focus on transferring energy from a single type of power source into a single type of load or energy storage system (ESS). While these systems can be optimized wit...Present-day power conversion and conditioning systems focus on transferring energy from a single type of power source into a single type of load or energy storage system (ESS). While these systems can be optimized within their specific topology (e.g. MPPT for solar applications and BMS for batteries), the topologies are not easily adapted to accept a wide range of power flow operating conditions. With a hybrid approach to energy storage and power flow, a system can be designed to operate at its most advantageous point, given the operating conditions. Based on the load demand, the system can select the optimal power source and ESS. This paper will investigate the feasibility of combining two types of power sources (main utility grid and photovoltaics (PV)) along with two types of ESS (ultra-capacitors and batteries). The simulation results will show the impact of a hybrid ESS on a grid-tied residential microgrid system performance under various operating scenarios.展开更多
Rectifiers with high efficiency and high power density are crucial to the stable and efficient power supply of 5G communication base stations,which deserves in-depth investigation.In general,there are two key problems...Rectifiers with high efficiency and high power density are crucial to the stable and efficient power supply of 5G communication base stations,which deserves in-depth investigation.In general,there are two key problems to be addressed:supporting both alternating current(AC)and direct current(DC)input,and minimizing the common-mode voltage as well as leakage current for safety reasons.In this paper,a hybrid five-level single-phase rectifier is proposed.A five-level topology is adopted in the upper arm,and a half-bridge diode topology is adopted in the lower arm.A dual closed-loop control strategy and a flying capacitor voltage regulation method are designed accordingly so that the compatibility of both AC and DC input is realized with low common voltage and small passive devices.Simulation and experimental results demonstrate the effectiveness and performance of the proposed rectifier.展开更多
在交直流混合微电网中,并联互联变流器(parallel bidirectional power converters,BPCs)可以实现大容量的功率传输,以满足新型电力系统在空间上的供需匹配。如何在占用更少资源的同时协调控制BPCs实现功率的比例共享,是交直流混合微电网...在交直流混合微电网中,并联互联变流器(parallel bidirectional power converters,BPCs)可以实现大容量的功率传输,以满足新型电力系统在空间上的供需匹配。如何在占用更少资源的同时协调控制BPCs实现功率的比例共享,是交直流混合微电网中BPCs控制的研究难点。因此,该文设计了一种针对BPCs的事件触发改进一致性协调控制策略。以归一化下垂控制为基础,提出了改进的比例功率一致性算法,实现BPCs间高精度比例功率共享。在此之上,基于BPCs比例功率误差建立事件触发改进一致性算法,并预设触发函数的预判阈值,从而降低系统在稳定状态下的通信次数。最后进行仿真对比分析,结果表明该文提出的方法相比基本一致性算法通信量减少98.35%;同时,与现有控制策略相比,该文提出的方法有着更好的控制性能。展开更多
针对微网独立运行时面临运行成本高,受可再生能源出力和多能负荷功率不确定性影响大等问题,提出一种基于混合两阶段鲁棒优化的多微网合作运行方法。首先,为了应对源荷双重不确定性挑战,在传统两阶段鲁棒优化基础上,提出一种基于多场景...针对微网独立运行时面临运行成本高,受可再生能源出力和多能负荷功率不确定性影响大等问题,提出一种基于混合两阶段鲁棒优化的多微网合作运行方法。首先,为了应对源荷双重不确定性挑战,在传统两阶段鲁棒优化基础上,提出一种基于多场景数据的最恶劣概率场景驱动的混合两阶段鲁棒优化方法,并采用可并行计算列与约束生成(column and constraint generation,C&CG)算法来提高求解效率。然后,在建立的多微网点对点分布式能源交易系统框架上,根据纳什谈判理论构造多微网合作成本最小化问题和收益分配问题,并提出一种耦合可并行计算C&CG的交替方向乘子法进行求解。最后,根据各微网不同的贡献率,设计一种基于点对点电能交易贡献度的非对称纳什谈判机制来分配各微网的合作收益。算例结果表明,所提方法能兼顾系统的鲁棒性、经济性和隐私性,并实现每个微网公平合理的收益分配。展开更多
文摘In recent years,the hybrid AC-DC microgrid has been well accepted as it combines the advantages of both AC and DC systems.As the microgrid contains both DC sub-grids and AC sub-grids,interlinking DC-AC converters are essential.Meanwhile,considering the nonlinear AC loads may deteriorate the voltage quality of the AC bus,embedding an ancillary harmonic compensation function to the interlinking converters is promising.However,the conventional harmonic control methods used for active power filters(APFs)may not be suitable for the interlinking converters due to the main purpose of it is to exchange real and reactive power between the DC and AC sub-grids.The switching frequency is preferred to be lower than the APFs when the capacity of the microgrid is large.At low switching frequency,harmonic compensation performance or even the system stability may be affected.In this paper,a harmonic compensation approach suitable for hybrid AC-DC interlinking converters at low switching frequency is proposed.Through feeding the PWM reference signal with the harmonic compensation component directly to avoid the multi-loop control path of the fundamental component,the proposed method can achieve the effective harmonics compensation without being limited by the closed-loop control bandwidth.The proposed method,modeling approaches,stability analysis,as well as detailed virtual impedance design are presented.Experimental verification is also provided.
基金supported by the NationalNatural Science Foundation of China Under Grant 61961017Key R&D Plan Projects in Hubei Province 2022BAA060.
文摘To reduce the comprehensive costs of the construction and operation of microgrids and to minimize the power fluctuations caused by randomness and intermittency in distributed generation,a double-layer optimizing configuration method of hybrid energy storage microgrid based on improved grey wolf optimization(IGWO)is proposed.Firstly,building a microgrid system containing a wind-solar power station and electric-hydrogen coupling hybrid energy storage system.Secondly,the minimum comprehensive cost of the construction and operation of the microgrid is taken as the outer objective function,and the minimum peak-to-valley of the microgrid’s daily output is taken as the inner objective function.By iterating through the outer and inner layers,the system improves operational stability while achieving economic configuration.Then,using the energy-self-smoothness of the microgrid as the evaluation index,a double-layer optimizing configuration method of the microgrid is constructed.Finally,to improve the disadvantages of grey wolf optimization(GWO),such as slow convergence in the later period and easy falling into local optima,by introducing the convergence factor nonlinear adjustment strategy and Cauchy mutation operator,an IGWO with excellent global performance is proposed.After testing with the typical test functions,the superiority of IGWO is verified.Next,using IGWO to solve the double-layer model.The case analysis shows that compared to GWO and particle swarm optimization(PSO),the IGWO reduced the comprehensive cost by 15.6%and 18.8%,respectively.Therefore,the proposed double-layer optimizationmethod of capacity configuration ofmicrogrid with wind-solar-hybrid energy storage based on IGWO could effectively improve the independence and stability of the microgrid and significantly reduce the comprehensive cost.
基金supported by the Deanship of Scientific Research(DSR)King Abdulaziz University,Jeddah(23-135-35-HiCi)
文摘Hybrid Petri nets(HPNs) are widely used to describe and analyze various industrial hybrid systems that have both discrete-event and continuous discrete-time behaviors. Recently,many researchers attempt to utilize them to characterize power and energy systems. This work proposes to adopt an HPN to model and analyze a microgrid that consists of green energy sources. A reachability graph for such a model is generated and used to analyze the system properties.
文摘This paper presents a method for optimal sizing of an off-grid hybrid microgrid (MG) system in order to achieve a certain load demand. The hybrid MG is made of a solar photovoltaic (PV) system, wind turbine (TW) and energy storage system (ESS). The reliability of the MG system is modeled based on the loss of power supply probability (SPSP). For optimization, an enhanced Genetic Algorithm (GA) is used to minimize the total cost of the system over a 20-year period, while satisfying some reliability and operation constraints. A case study addressing optimal sizing of an off-grid hybrid microgrid in Nigeria is discussed. The result is compared with results obtained from the Brute Force and standard GA methods.
基金funded by the Natural Science Foundation of Shaanxi Province,Grant No.2021GY-135the Scientific Research Project of Yan’an University,Grant No.YDQ2018-07.
文摘Distributed collaborative control strategies for microgrids often use periodic time to trigger communication,which is likely to enhance the burden of communication and increase the frequency of controller updates,leading to greater waste of communication resources.In response to this problem,a distributed cooperative control strategy triggered by an adaptive event is proposed.By introducing an adaptive event triggering mechanism in the distributed controller,the triggering parameters are dynamically adjusted so that the distributed controller can communicate only at a certain time,the communication pressure is reduced,and the DC bus voltage deviation is effectively reduced,at the same time,the accuracy of power distribution is improved.The MATLAB/Simulink modeling and simulation results prove the correctness and effectiveness of the proposed control strategy.
基金Chinese Academy of Science (No.KGCX2- YW- 366)Ministry of Science and Technology(No. 2011AA05A106)
文摘Small-hydro power station is often used in remote areas beside a river,but it doesn't match electricity demand so well,especially in dry seasons. A photovoltaic (PV) system with battery is a suitable option to complement the electricity gap. In this paper,a new structure of megawatt-class PV system integrating battery at DC-bus (DC: direct current) is proposed to be used in hydro/PV hybrid power system,and 4 main designing considerations and several key equipments are discussed. In 2011,a 2 MWp PV station with the proposed structure was built up in Yushu,China. From stability analysis,the station shows a strong stability under load cut-in/off and solar irradiance's fluctuation.
文摘Present-day power conversion and conditioning systems focus on transferring energy from a single type of power source into a single type of load or energy storage system (ESS). While these systems can be optimized within their specific topology (e.g. MPPT for solar applications and BMS for batteries), the topologies are not easily adapted to accept a wide range of power flow operating conditions. With a hybrid approach to energy storage and power flow, a system can be designed to operate at its most advantageous point, given the operating conditions. Based on the load demand, the system can select the optimal power source and ESS. This paper will investigate the feasibility of combining two types of power sources (main utility grid and photovoltaics (PV)) along with two types of ESS (ultra-capacitors and batteries). The simulation results will show the impact of a hybrid ESS on a grid-tied residential microgrid system performance under various operating scenarios.
文摘Rectifiers with high efficiency and high power density are crucial to the stable and efficient power supply of 5G communication base stations,which deserves in-depth investigation.In general,there are two key problems to be addressed:supporting both alternating current(AC)and direct current(DC)input,and minimizing the common-mode voltage as well as leakage current for safety reasons.In this paper,a hybrid five-level single-phase rectifier is proposed.A five-level topology is adopted in the upper arm,and a half-bridge diode topology is adopted in the lower arm.A dual closed-loop control strategy and a flying capacitor voltage regulation method are designed accordingly so that the compatibility of both AC and DC input is realized with low common voltage and small passive devices.Simulation and experimental results demonstrate the effectiveness and performance of the proposed rectifier.
文摘在交直流混合微电网中,并联互联变流器(parallel bidirectional power converters,BPCs)可以实现大容量的功率传输,以满足新型电力系统在空间上的供需匹配。如何在占用更少资源的同时协调控制BPCs实现功率的比例共享,是交直流混合微电网中BPCs控制的研究难点。因此,该文设计了一种针对BPCs的事件触发改进一致性协调控制策略。以归一化下垂控制为基础,提出了改进的比例功率一致性算法,实现BPCs间高精度比例功率共享。在此之上,基于BPCs比例功率误差建立事件触发改进一致性算法,并预设触发函数的预判阈值,从而降低系统在稳定状态下的通信次数。最后进行仿真对比分析,结果表明该文提出的方法相比基本一致性算法通信量减少98.35%;同时,与现有控制策略相比,该文提出的方法有着更好的控制性能。
文摘针对微网独立运行时面临运行成本高,受可再生能源出力和多能负荷功率不确定性影响大等问题,提出一种基于混合两阶段鲁棒优化的多微网合作运行方法。首先,为了应对源荷双重不确定性挑战,在传统两阶段鲁棒优化基础上,提出一种基于多场景数据的最恶劣概率场景驱动的混合两阶段鲁棒优化方法,并采用可并行计算列与约束生成(column and constraint generation,C&CG)算法来提高求解效率。然后,在建立的多微网点对点分布式能源交易系统框架上,根据纳什谈判理论构造多微网合作成本最小化问题和收益分配问题,并提出一种耦合可并行计算C&CG的交替方向乘子法进行求解。最后,根据各微网不同的贡献率,设计一种基于点对点电能交易贡献度的非对称纳什谈判机制来分配各微网的合作收益。算例结果表明,所提方法能兼顾系统的鲁棒性、经济性和隐私性,并实现每个微网公平合理的收益分配。