Ultrasonic aided slurry sampling hydride generation atomic fluorescence spectrometry (USS-HG-AFS) was developed for the determination of Hg in soil samples from a sewage-irrigated farm. 500 mg grounded soil was susp...Ultrasonic aided slurry sampling hydride generation atomic fluorescence spectrometry (USS-HG-AFS) was developed for the determination of Hg in soil samples from a sewage-irrigated farm. 500 mg grounded soil was suspended in agar solution by an ultrasound water bath before the HG-AFS determination. The results for the reference material of soil (serial number GBW-07411) agreed satisfactorily with the certified values. Results obtained by the developed procedure compared well with those after traditional acid digestion of samples. The detection limit are 6.7ngL-1 for Hg respectively, with average relative standard deviation values of 6.4% for analysis of a series of soil samples of different origin. The recoveries of the anatytes varied in the range from 95 to 107%. This observation has stimulated interest in fast, accurate and sensitive analytical methods for determination of metals in soil.展开更多
In this paper, two different diameter particles (TSP, PM10) were collected by TH-16A four-channels classification air sampler. The samples were treated by HNO3. Analysis of cadmium was carried out by hydride generat...In this paper, two different diameter particles (TSP, PM10) were collected by TH-16A four-channels classification air sampler. The samples were treated by HNO3. Analysis of cadmium was carried out by hydride generation atomic fluorescence spectrometry (HG-AFS) method, and distribution proportions of elements in four phases were calculated. This method was based on the reaction of cadmium with 1.5% (m/v) KBH4 solution and 0.5% KOH(m/v) solution to form the hydride gas in medium of 2% (v/v) HCl. The detection limit for cadmium as low as 0.008μg/L was obtained. The lineally correlation coefficient was 0.99992. The relative standard deviation (n=5, C=1.00μg/L) was 3.26%. The proposed method was applied for the determination of cadmium in atmosphere aerosol samples and the recoveries in the range of 95-102.2% were obtained. This method was simple, rapid, less matrix interference and high sensitivity.展开更多
Standard reference material and different geological samples were dissolved by system A (the mixture of nitric and perchloric acids) and system B (mixture of nitric, perchloric and hydrofluoric acids), and total Se in...Standard reference material and different geological samples were dissolved by system A (the mixture of nitric and perchloric acids) and system B (mixture of nitric, perchloric and hydrofluoric acids), and total Se in all samples was measured by hydride-generation atomic fluorescence spectrometry (HG-AFS) after concentration with thiol cotton fiber (TCF). The analytical results obtained by the two digestion method are in good agreement (within the limit of errors) for most of the samples, particularly for those having recommended values. The Se concentrations determined by the two methods are of no difference, and the correlation coefficient is 0.9986; the relative standard deviation (RSD) for the determination of 0.04 μg/g Se is 10.2%. The recovery rates of systems A and B by the stan- dard-addition method were 96%–106% and 99%–104%, respectively.展开更多
文摘Ultrasonic aided slurry sampling hydride generation atomic fluorescence spectrometry (USS-HG-AFS) was developed for the determination of Hg in soil samples from a sewage-irrigated farm. 500 mg grounded soil was suspended in agar solution by an ultrasound water bath before the HG-AFS determination. The results for the reference material of soil (serial number GBW-07411) agreed satisfactorily with the certified values. Results obtained by the developed procedure compared well with those after traditional acid digestion of samples. The detection limit are 6.7ngL-1 for Hg respectively, with average relative standard deviation values of 6.4% for analysis of a series of soil samples of different origin. The recoveries of the anatytes varied in the range from 95 to 107%. This observation has stimulated interest in fast, accurate and sensitive analytical methods for determination of metals in soil.
文摘In this paper, two different diameter particles (TSP, PM10) were collected by TH-16A four-channels classification air sampler. The samples were treated by HNO3. Analysis of cadmium was carried out by hydride generation atomic fluorescence spectrometry (HG-AFS) method, and distribution proportions of elements in four phases were calculated. This method was based on the reaction of cadmium with 1.5% (m/v) KBH4 solution and 0.5% KOH(m/v) solution to form the hydride gas in medium of 2% (v/v) HCl. The detection limit for cadmium as low as 0.008μg/L was obtained. The lineally correlation coefficient was 0.99992. The relative standard deviation (n=5, C=1.00μg/L) was 3.26%. The proposed method was applied for the determination of cadmium in atmosphere aerosol samples and the recoveries in the range of 95-102.2% were obtained. This method was simple, rapid, less matrix interference and high sensitivity.
基金the Knowledge-Innovation Program of the Chinese Academy of Sciences(KZCX3-SW-125);the National Natural Science Foundation of China(Grant Nos.60633110,40003008).
文摘Standard reference material and different geological samples were dissolved by system A (the mixture of nitric and perchloric acids) and system B (mixture of nitric, perchloric and hydrofluoric acids), and total Se in all samples was measured by hydride-generation atomic fluorescence spectrometry (HG-AFS) after concentration with thiol cotton fiber (TCF). The analytical results obtained by the two digestion method are in good agreement (within the limit of errors) for most of the samples, particularly for those having recommended values. The Se concentrations determined by the two methods are of no difference, and the correlation coefficient is 0.9986; the relative standard deviation (RSD) for the determination of 0.04 μg/g Se is 10.2%. The recovery rates of systems A and B by the stan- dard-addition method were 96%–106% and 99%–104%, respectively.