期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Determination of Mecruy at Trace Level in Natural Water Samples by Hydride Generation Atomic Absorption Spectrophotometry after Cloud Point Extraction Preconcentration 被引量:2
1
作者 Ji Ying SONG Ming HOU Li Xiang ZHANG 《Chinese Chemical Letters》 SCIE CAS CSCD 2006年第9期1217-1220,共4页
A method for the determination of trace mercury in water samples by hydride generation atomic absorption spectrophotometry after cloud point extraction was proposed in the present work. The effects of pH, concentratio... A method for the determination of trace mercury in water samples by hydride generation atomic absorption spectrophotometry after cloud point extraction was proposed in the present work. The effects of pH, concentration of surfactant, and equilibration time on cloud point extraction were discussed. The enhancement factor of 20 and the detection limit of 0.039 μg/L were obtained for mercury with relative standard deviation of 4.8% (n = 11). 展开更多
关键词 Cloud point extraction MERCURY hydride generation atomic absorption spectrophotometry.
下载PDF
DETERMINATION OF ANTIMONY IN WATER SAMPLES BY FLOW-INJECTION HYDRIDE GENERATION ATOMIC ABSORPTION SPECTROMETRY WITH ON-LINE ION-EXCHANGE COLUMN PRECONCENTRATION
2
作者 Shu Kun XU and Zhao Lun FANG Institute of Applied Ecology, Academia Sinica, Shenyang, 110015 《Chinese Chemical Letters》 SCIE CAS CSCD 1992年第11期915-918,共4页
On-line ion-exchange separation and preconcentration were combined with flow-injection hydride generation atomic absorption spectrometry (HGAAS) to determine ultra-trace amounts of antimony in water samples. Antimony(... On-line ion-exchange separation and preconcentration were combined with flow-injection hydride generation atomic absorption spectrometry (HGAAS) to determine ultra-trace amounts of antimony in water samples. Antimony(Ⅲ) was preconcentrated on a micro-column packed with CPG-8Q chelating ion-exchanger using time-based sample loading and eluted by 4 mol l^(-1) HCl directly into the hydride generation AAS system. A detection limit (3σ) of 0.0015μg l^(-1) Sb(Ⅲ) was obtained on the basis of a 20 fold enrichment and with a sampling frequency of 60h^(-1). The precision was 1.0% r.s.d.(n=11) at the 0.5μg l^(-1) Sb(Ⅲ) level. Recoveries for the analysis of antimony in tap water, snow water and sea water samples were in the range 97-102%. 展开更多
关键词 Zhang DETERMINATION OF ANTIMONY IN WATER SAMPLES BY FLOW-INJECTION hydride generation atomic ABSORPTION SPECTROMETRY WITH ON-LINE ION-EXCHANGE COLUMN PRECONCENTRATION SQ CPG ION LINE
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部