A method was developed for the determination of total arsenic concentration in less than ng/ml level by decomposition of organoarsenicals using photo -oxidation combined with in situ trapping of arsenic hydride on a p...A method was developed for the determination of total arsenic concentration in less than ng/ml level by decomposition of organoarsenicals using photo -oxidation combined with in situ trapping of arsenic hydride on a palladium coated graphite tube with subsequent atomization and detection by AAS. The organoarsenicals include monomethylarsenic, dimethylarsenic, arsenobetaine, arsenocholine, o -aminobenzenarsenate and p -aminobenzenarsenate. The method is simple and sensitive. Detection limit was obtained from different arsenic compounds over the range from 0. 058 to 0.063 ng/ml as As (based on three times of the standard deviation of 10 blank measurements) and the relative standard deviations for ten replicate measurements were from 2.0 to 3.8%. The calibration curves of arsenic compounds including inorganic and organic arsenicals were linear over the range from 0.1 to 3.0 ng/ml as As. The recommended method has been applied to the determination of total arsenic in tap and lake water samples at ng/ml levels.展开更多
On-line ion-exchange separation and preconcentration were combined with flow-injection hydride generation atomic absorption spectrometry (HGAAS) to determine ultra-trace amounts of antimony in water samples. Antimony(...On-line ion-exchange separation and preconcentration were combined with flow-injection hydride generation atomic absorption spectrometry (HGAAS) to determine ultra-trace amounts of antimony in water samples. Antimony(Ⅲ) was preconcentrated on a micro-column packed with CPG-8Q chelating ion-exchanger using time-based sample loading and eluted by 4 mol l^(-1) HCl directly into the hydride generation AAS system. A detection limit (3σ) of 0.0015μg l^(-1) Sb(Ⅲ) was obtained on the basis of a 20 fold enrichment and with a sampling frequency of 60h^(-1). The precision was 1.0% r.s.d.(n=11) at the 0.5μg l^(-1) Sb(Ⅲ) level. Recoveries for the analysis of antimony in tap water, snow water and sea water samples were in the range 97-102%.展开更多
文摘A method was developed for the determination of total arsenic concentration in less than ng/ml level by decomposition of organoarsenicals using photo -oxidation combined with in situ trapping of arsenic hydride on a palladium coated graphite tube with subsequent atomization and detection by AAS. The organoarsenicals include monomethylarsenic, dimethylarsenic, arsenobetaine, arsenocholine, o -aminobenzenarsenate and p -aminobenzenarsenate. The method is simple and sensitive. Detection limit was obtained from different arsenic compounds over the range from 0. 058 to 0.063 ng/ml as As (based on three times of the standard deviation of 10 blank measurements) and the relative standard deviations for ten replicate measurements were from 2.0 to 3.8%. The calibration curves of arsenic compounds including inorganic and organic arsenicals were linear over the range from 0.1 to 3.0 ng/ml as As. The recommended method has been applied to the determination of total arsenic in tap and lake water samples at ng/ml levels.
文摘On-line ion-exchange separation and preconcentration were combined with flow-injection hydride generation atomic absorption spectrometry (HGAAS) to determine ultra-trace amounts of antimony in water samples. Antimony(Ⅲ) was preconcentrated on a micro-column packed with CPG-8Q chelating ion-exchanger using time-based sample loading and eluted by 4 mol l^(-1) HCl directly into the hydride generation AAS system. A detection limit (3σ) of 0.0015μg l^(-1) Sb(Ⅲ) was obtained on the basis of a 20 fold enrichment and with a sampling frequency of 60h^(-1). The precision was 1.0% r.s.d.(n=11) at the 0.5μg l^(-1) Sb(Ⅲ) level. Recoveries for the analysis of antimony in tap water, snow water and sea water samples were in the range 97-102%.