In this study, thermal–hydraulic parameters inside the containment of aWWER-1000/v446 nuclear power plant are simulated in a double-ended cold leg accident for short and long times (by using CONTAIN 2.0 and MELCOR 1....In this study, thermal–hydraulic parameters inside the containment of aWWER-1000/v446 nuclear power plant are simulated in a double-ended cold leg accident for short and long times (by using CONTAIN 2.0 and MELCOR 1.8.6 codes), and the effect of the spray system as an engineering safety feature on parameters mitigation is analyzed with the former code. Along with the development of the accident from design basis accident to beyond design basis accident, the Zircaloy–steam reaction becomes the source of in-vessel hydrogen generation. Hydrogen distribution inside the containment is simulated for a long time (using CONTAIN and MELCOR), and the effect of recombiners on its mitigation is analyzed (using MELCOR). Thermal–hydraulic parameters and hydrogen distribution profiles are presented as the outcome of the investigation. By activating the spray system, the peak points of pressure and temperature occur in the short time and remain belowthe maximumdesign values along the accident time. It is also shown that recombiners have a reliable effect on reducing the hydrogen concentration below flame propagation limit in the accident localization area. The parameters predicted by CONTAIN and MELCOR are in good agreement with the final safety analysis report. The noted discrepancies are discussed and explained.展开更多
The hydrogen deflagration is one of the major risk contributors to threaten the integrity of the containment in a nuclear power plant, and hydrogen control in the case of severe accidents is required by nuclear regula...The hydrogen deflagration is one of the major risk contributors to threaten the integrity of the containment in a nuclear power plant, and hydrogen control in the case of severe accidents is required by nuclear regulations. Based on the large dry containment model developed with the integral severe-accident analysis tool, a small-break loss-of-coolant-accident (LOCA) without HPI, LPI, AFW and containment sprays, leading to the core degradation and large hydrogen generation, is calculated. Hydrogen and steam distribution in containment compartments is investi- gated. The analysis results show that significant hydrogen deflagration risk exits in the reactor coolant pump (RCP) compartment and the cavity during the early period, if no actions are taken to mitigate the effects of hydrogen accu- mulation.展开更多
基金Part of this research has been developed under the auspices of EU H2020 Union’s Horizon 2020 research and innovation programme Marie Sklodowska-Curie Actions COFUND Grant SIRCIW,Agreement No.663830.
文摘In this study, thermal–hydraulic parameters inside the containment of aWWER-1000/v446 nuclear power plant are simulated in a double-ended cold leg accident for short and long times (by using CONTAIN 2.0 and MELCOR 1.8.6 codes), and the effect of the spray system as an engineering safety feature on parameters mitigation is analyzed with the former code. Along with the development of the accident from design basis accident to beyond design basis accident, the Zircaloy–steam reaction becomes the source of in-vessel hydrogen generation. Hydrogen distribution inside the containment is simulated for a long time (using CONTAIN and MELCOR), and the effect of recombiners on its mitigation is analyzed (using MELCOR). Thermal–hydraulic parameters and hydrogen distribution profiles are presented as the outcome of the investigation. By activating the spray system, the peak points of pressure and temperature occur in the short time and remain belowthe maximumdesign values along the accident time. It is also shown that recombiners have a reliable effect on reducing the hydrogen concentration below flame propagation limit in the accident localization area. The parameters predicted by CONTAIN and MELCOR are in good agreement with the final safety analysis report. The noted discrepancies are discussed and explained.
文摘The hydrogen deflagration is one of the major risk contributors to threaten the integrity of the containment in a nuclear power plant, and hydrogen control in the case of severe accidents is required by nuclear regulations. Based on the large dry containment model developed with the integral severe-accident analysis tool, a small-break loss-of-coolant-accident (LOCA) without HPI, LPI, AFW and containment sprays, leading to the core degradation and large hydrogen generation, is calculated. Hydrogen and steam distribution in containment compartments is investi- gated. The analysis results show that significant hydrogen deflagration risk exits in the reactor coolant pump (RCP) compartment and the cavity during the early period, if no actions are taken to mitigate the effects of hydrogen accu- mulation.