期刊文献+
共找到684篇文章
< 1 2 35 >
每页显示 20 50 100
Nonlinear Behavior of Reinforced Concrete Slit Shear Walls under Seismic Actions *
1
作者 戴航 陈忠范 +1 位作者 关国雄 张佑启 《Journal of Southeast University(English Edition)》 EI CAS 1998年第1期86-92,共7页
A reinforced concrete slit shear wall is a new breed of earthquake resistant structure recently proposed by the authors. In this paper, the seismic responses of the slit shear walls under the shake of earthquake exci... A reinforced concrete slit shear wall is a new breed of earthquake resistant structure recently proposed by the authors. In this paper, the seismic responses of the slit shear walls under the shake of earthquake excitation have been dealt with. Based on a simplified structural model, which is shown to have a sufficient accuracy for the real slit shear wall structure, the analysis focuses on the influence of nonlinear behavior of the connecting beams between the slits on the dynamic performance of the whole slit shear wall structure. It has been found that the yielding of connecting beams in a slit shear wall can provide significant improvement in reducing the structural responses, and by choosing an appropriate strength value for the connecting beams, it is possible to optimize the seismic response of the slit shear wall. 展开更多
关键词 seismic response slit shear wall reinforced concrete connecting beam
下载PDF
Post-fire cyclic behavior of reinforced concrete shear walls 被引量:5
2
作者 刘桂荣 宋玉普 曲福来 《Journal of Central South University》 SCIE EI CAS 2010年第5期1103-1108,共6页
The effects of fire exposure,reinforcement ratio and the presence of axial load under fire on the seismic behavior of reinforced concrete(RC) shear walls were investigated.Five RC shear walls were tested under low cyc... The effects of fire exposure,reinforcement ratio and the presence of axial load under fire on the seismic behavior of reinforced concrete(RC) shear walls were investigated.Five RC shear walls were tested under low cyclic loading.Prior to the cyclic test,three specimens were exposed to fire and two of them were also subjected to a constant axial load.Test results indicate that the ultimate load of the specimen with lower reinforcement ratio is reduced by 15.8%after exposure to elevated temperatures.While the reductions in the energy dissipation and initial stiffness are 59.2%and 51.8%,respectively,which are much higher than those in the ultimate load.However,this deterioration can be slowed down by properly increasing reinforcement due to the strength and stiffness recovery of steel bars after cooling.In addition,the combined action of elevated temperatures and axial load results in more energy dissipation than the action of fire exposure alone. 展开更多
关键词 shear wall reinforced concrete post-fire seismic behavior low cyclic loading
下载PDF
Experimental studies on behavior of fully grouted reinforced-concrete masonry shear walls 被引量:3
3
作者 Zhao Yan Wang Fenglai 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2015年第4期743-757,共15页
An experimental study is conducted on fully grouted reinforced masonry shear walls (RMSWs) made from concrete blocks with a new configuration. Ten RMSWs are tested under reversed cyclic lateral load to investigate the... An experimental study is conducted on fully grouted reinforced masonry shear walls (RMSWs) made from concrete blocks with a new configuration. Ten RMSWs are tested under reversed cyclic lateral load to investigate the influence of different reinforcements and applied axial stress values on their seismic behavior. The results show that flexural strength increases with the applied axial stress, and shear strength dominated by diagonal cracking increases with both the amount of horizontal reinforcement and applied axial stress. Yield displacement, ductility, and energy dissipation capability can be improved substantially by increasing the amount of horizontal reinforcement. The critical parameters for the walls are derived from the experiment: displacement ductility values corresponding to 15% strength degradation of the walls reach up to 2.6 and 4.5 in the shear and flexure failure modes, respectively; stiffness values of flexure- and shear-dominated walls rapidly degrade to 17%–19% and 48%–57% of initial stiffness at 0.50 D<sub>max</sub> (displacement at peak load). The experiment suggests that RMSWs could be assigned a higher damping ratio (~14%) for collapse prevention design and a lower damping value (~7%) for a fully operational limit state or serviceability limit state. 展开更多
关键词 reinforced-concrete masonry shear wall shear strength DUCTILITY stiffness degradation energy dissipation equivalent viscous damping ratio
下载PDF
Nonlinear Finite Element Analysis of Mechanical Performance of Reinforced Concrete Short-Limb Shear Wall 被引量:1
4
作者 XUELi-min 《Wuhan University Journal of Natural Sciences》 EI CAS 2005年第3期562-565,共4页
On the basis of test, nonlinear finite element analysis of reinforcedconcrete (R. C) short-limb shear walls under monotonic horizontal load are carried out by ANSYSprogram in order to understand the evolution of crack... On the basis of test, nonlinear finite element analysis of reinforcedconcrete (R. C) short-limb shear walls under monotonic horizontal load are carried out by ANSYSprogram in order to understand the evolution of cracking, deformation and failure course of thespecimens. At the same time, the results of numerical calculation are compared with the results oftest. The results indicate that, under monotonic horizontal load the failures of the specimens withflange wall and without flange wall all occur at the intersections of lintel bottom and limb ofwall, the failures also occur at the bottom of limb; the load-displacement curve of wall withoutflange is steeper than that of wall with flange, and the ductility is worse than that of wall withflange; the results, such as cracking, deformation, yield load and so on of finite element analysisagree well with the results of test. These results provide theoretical basis of study andapplication of R. C short-limb shear wall. 展开更多
关键词 reinforced concrete short-limb shear wall mechanical performance finiteelement method NONLINEAR
下载PDF
Performance index limits of high reinforced concrete shear wall components 被引量:1
5
作者 劳晓春 韩小雷 《Journal of Central South University》 SCIE EI CAS 2011年第4期1248-1255,共8页
The deformation performance index limits of high reinforced concrete (RC) shear wall components based on Chinese codes were discussed by the nonlinear finite element method. Two typical RC shear wall specimens in th... The deformation performance index limits of high reinforced concrete (RC) shear wall components based on Chinese codes were discussed by the nonlinear finite element method. Two typical RC shear wall specimens in the previous work were first used to verify the correctness of the nonlinear finite element method. Then, the nonlinear finite element method was applied to study the deformability of a set of high RC shear wall components designed according to current Chinese codes and with shear span ratio λ≥2.0. Parametric studies were made on the influence of shear span ratio, axial compression ratio, ratio of flexural capacity to shear capacity and main flexural reinforcement ratio of confined botmdary members. Finally, the deformation performance index and its limits of high RC shear wall components under severe earthquakes were proposed by the finite element model results, which offers a reference in determining the performance status of RC shear wall components designed based on Chinese codes. 展开更多
关键词 reinforced concrete shear wall components performance index limits nonlinear finite element method Chinese codes
下载PDF
Analysis on Construction Quality Control Technology of Reinforced Concrete Shear Wall Structure
6
作者 Ting Zhou 《Frontiers Research of Architecture and Engineering》 2018年第4期117-121,共5页
In the process of continuous development of construction enterprises, new requirements have been put forward for construction projects. By strengthening the construction quality control of reinforced concrete shear wa... In the process of continuous development of construction enterprises, new requirements have been put forward for construction projects. By strengthening the construction quality control of reinforced concrete shear wall structure, the construction level of reinforced concrete can be continuously improved, the construction quality can be guaranteed, and the construction project can be successfully completed, which is worthy of extensive application and promotion in construction enterprises, thus providing a broader development space for construction enterprises. 展开更多
关键词 reinforced concrete shear wall structure Construction QUALITY Control technology
下载PDF
Experimental and analytical study on seismic behavior of steel-concrete multienergy dissipation composite shear walls 被引量:5
7
作者 Dong Hongying Cao Wanlin +2 位作者 Wu Haipeng Qiao Qiyun Yu Chuanpeng 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2015年第1期125-139,共15页
In this paper, a steel-concrete multi-energy dissipation composite shear wall, comprised of steel-reinforced concrete (SRC) columns, steel plate (SP) deep beams, a concrete wall and energy dissipation strips, is p... In this paper, a steel-concrete multi-energy dissipation composite shear wall, comprised of steel-reinforced concrete (SRC) columns, steel plate (SP) deep beams, a concrete wall and energy dissipation strips, is proposed. In order to study the multi-energy dissipation behavior and restorability after an earthquake, two stages of low cyclic loading tests were carded out on ten test specimens. In the first stage, test on five specimens with different number of SP deep beams was carried out, and the test lasted until the displacement drift reached 2%. In the second stage, thin SPs were welded to both sides of the five specimens tested in the first stage, and the same test was carried out on the repaired specimens (designated as new specimens). The load-bearing capacity, stiffness, ductility, hysteretic behavior and failure characteristics were analyzed for both stages and the results are discussed herein. Extrapolating from these results, strength calculation models and formulas are proposed herein and simulations using ABAQUS carried out, they show good agreement with the test results. The study demonstrates that SRC columns, SP deep beams, concrete wall and energy dissipation strips cooperate well and play an important role in energy dissipation. In addition, this study shows that the shear wall has good recoverability after an earthquake, and that the welding of thin SP's to repair a deformed wall is a practicable technique. 展开更多
关键词 steel reinforced concrete steel plate deep beam multi energy dissipation composite shear wall seismic behavior
下载PDF
Experimental testing of RC shear wall seismic retrofit using selective weakening,self-centering and Ultra High performance concrete
8
作者 Sumedh S.harma Sriram Aaleti Pinar Okumus 《Resilient Cities and Structures》 2023年第1期76-90,共15页
Traditional retrofit methods often focus on increasing the structure’s strength,stiffness,or both.This may in-crease seismic demand on the structure and could lead to irreparable damage during a seismic event.This pa... Traditional retrofit methods often focus on increasing the structure’s strength,stiffness,or both.This may in-crease seismic demand on the structure and could lead to irreparable damage during a seismic event.This paper presents a retrofit method,integrating concepts of selective weakening and self-centering(rocking)to achieve low seismic damage for non-code compliant reinforced concrete shear walls.The proposed method involves con-verting traditional cast-in-place concrete shear walls into rocking walls,which helps to lower the shear demand,while allowing re-centering.Two large-scale lateral load tests were performed to validate the retrofit concept on a concrete shear wall designed according to pre-1970s standards.The design parameters investigated were amount of energy dissipating reinforcements and confinement enhancement.Two different methods using Ultra High Performance Concrete(UHPC)were investigated to provide additional confinement to boundary elements of older shear walls.Observations from the tests showed minimized damage and enhanced recentering in the retrofitted wall specimens.Use of UHPC in the boundary elements of the retrofitted walls provided additional confinement and reduced damage in the rocking corners. 展开更多
关键词 Seismic retrofit reinforced concrete shear walls Selective weakening SELF-CENTERING Ultra-high performance concrete(UHPC) CONFINEMENT
下载PDF
High-Rise Residential Reinforced Concrete Building Optimisation
9
作者 Haibei Xiong Miguel Angel Hidalgo Calvo 《Open Journal of Civil Engineering》 2015年第4期437-450,共14页
In the last few decades structure optimisation has become a main task in a civil engineering project. As a matter of fact, due to the complexity and particularity of every structure, the great amount of variables and ... In the last few decades structure optimisation has become a main task in a civil engineering project. As a matter of fact, due to the complexity and particularity of every structure, the great amount of variables and design criteria to considerate and many other factors, a general optimisation’s method is not simple to formulate. As a result, this paper focuses on how to provide a successful optimisation method for a particular building type, high-rise reinforced concrete buildings. The optimization method is based on decomposition of the main structure into substructures: floor system, vertical load resisting system, lateral load resisting system and foundation system;then each of the subsystems using the design criteria established at the building codes is improved. Due to the effect of the superstructure optimisation on the foundation system, vertical and lateral load resisting system is the last to be considered after the improvement of floor. Finally, as a case example, using the method explained in the paper, a 30-story-high high-rise residential building complex is analysed and optimised, achieving good results in terms of structural behaviour and diminishing the overall cost of the structure. 展开更多
关键词 STRUCTURE Optimisation HIGH-RISE RESIDENTIAL reinforced concrete Buildings shear-wall STRUCTURE Deep PILES Post GROUTING
下载PDF
Effect of Eccentric Shear Stiffness of Walls on Structural Response of RC Frame Buildings
10
作者 Muhammad Umair Saleem 《Open Journal of Civil Engineering》 2017年第4期527-538,共12页
Current research study consists of determining the optimum location of the shear wall to get the maximum structural efficiency of a reinforced concrete frame building. It consists of a detailed analysis and design rev... Current research study consists of determining the optimum location of the shear wall to get the maximum structural efficiency of a reinforced concrete frame building. It consists of a detailed analysis and design review of a seven-story reinforced concrete building to understand the effect of shear wall location on the response of reinforced concrete structures when subjected to different earthquake forces. Three trail locations of shear walls are selected and their performance is monitored in terms of structural response under different lateral loads. Required objectives are achieved by obtaining design and construction drawings of an existing reinforced concrete structure and modeling it on Finite Element Method (FEM) based computer software. The structure is redesigned and discussed with four different configurations (one without shear wall and three with shear walls). Main framing components (Beams, Columns and Shear walls) of the superstructure are designed using SAP 2000 V. 19.0 whereas substructure (foundation) of RC building was?designed using SAFE. American Concrete Institute (ACI) design specifications were used to calculate the cracked section stiffness or non-linear geometrical properties of the cracked section. Uniform Building Code (UBC-97) procedures were adopted to calculate the lateral earthquake loading on the structures. Structural response of the building was monitored at each story level for each earthquake force zone described by the UBC-97. The earthquake lateral forces were considered in both X and Y direction of the building. Each configuration of shear wall is carefully analyzed and effect of its location is calibrated by the displacement response of the structure. Eccentricity to the lateral stiffness of the building is imparted by changing the location of shear walls. Results of the study have shown that the location of shear wall significantly affects the lateral response of the structure under earthquake forces. It also motivates to carefully decide the center of lateral stiffness of building prior to deciding the location of shear walls. 展开更多
关键词 reinforced concrete BUILDINGS COMPUTER aided Modelling shear walls Stiff-ness Deformations
下载PDF
Collapse Patterns and Their Discrimination of Reinforced Concrete Shear Wall Under Combined Stresses of Compression and Shear due to Strong Earthquake 被引量:1
11
作者 ZHA Zhixiang LIU Xila XU Bo 《Journal of Shanghai Jiaotong university(Science)》 EI 2020年第4期495-508,共14页
The collapse patterns of reinforced concrete(RC)shear walls under seismic load are proposed.The crack distribution and propagation of shear walls are specifically based on the failure criterions of Mohr-Coulomb with t... The collapse patterns of reinforced concrete(RC)shear walls under seismic load are proposed.The crack distribution and propagation of shear walls are specifically based on the failure criterions of Mohr-Coulomb with tension cutoff.Three zones and five different corresponding failure modes of RC shear walls are determined according to the transfer path of shear stress in shear wall.These failure modes of shear walls under seismic load are verified by many experimental results and can be utilized in collapsing analysis for frame-shear wall structure. 展开更多
关键词 reinforced concrete(RC) shear walls collapsing patterns seismic load
原文传递
Structural Analysis of a RC Shear Wall by Use of a Truss Model
12
作者 Panagis G. Papadopoulos Periklis E. Lamprou 《Open Journal of Civil Engineering》 CAS 2022年第3期320-352,共33页
Purpose of present work is to develop a reliable and simple method for structural analysis of RC Shear Walls. The shear wall is simulated by a truss model as the bar of a truss is the simplest finite element. An itera... Purpose of present work is to develop a reliable and simple method for structural analysis of RC Shear Walls. The shear wall is simulated by a truss model as the bar of a truss is the simplest finite element. An iterative method is used. Initially, there are only concrete bars. Repeated structural analyses are performed. After each structural analysis, every concrete bar exceeding tensile strength is replaced by a steel bar. For every concrete bar exceeding compressive strength, first its section area is increased. If this is not enough, a steel bar is placed at the side of it. For every steel bar exceeding tensile or compressive strength, its section area is increased. After the end of every structural analysis, if all concrete and steel bars fall within tensile and compressive strengths, the output data are written and the analysis is terminated. Otherwise, the structural analysis is repeated. As all the necessary conditions (static, elastic, linearized geometric) are satisfied and the stresses of ALL concrete and steel bars fall within the tensile and compressive strengths, the results are acceptable. Usually, the proposed method exhibits a fast convergence in 4 - 5 repeats of structural analysis of the RC Shear Wall. 展开更多
关键词 reinforced concrete shear wall Structural Analysis Truss Model Iterative Method Computer Program Boundary Columns and Beam Grid of Horizontal and Diagonal reinforcing Steel Bars
下载PDF
考虑二次受力效应的既有端柱-加固剪力墙构件受力性能数值分析
13
作者 范夕森 金腾飞 《建筑结构》 北大核心 2025年第2期132-142,125,共12页
增设剪力墙把框架结构改造成框架-剪力墙结构,能够避免提高抗震等级而需要加固全部框架的繁琐工作。研究新增墙体形成的端柱-剪力墙与整浇剪力墙力学性能的不同,能为框架结构采用改变体系的加固方式提供设计依据。考虑新老混凝土粘结界... 增设剪力墙把框架结构改造成框架-剪力墙结构,能够避免提高抗震等级而需要加固全部框架的繁琐工作。研究新增墙体形成的端柱-剪力墙与整浇剪力墙力学性能的不同,能为框架结构采用改变体系的加固方式提供设计依据。考虑新老混凝土粘结界面的破坏和端柱二次受力影响,采用数值分析方法,研究了端柱-剪力墙在水平作用下的破坏机制和承载力,并与整浇剪力墙进行了对比。结果表明:随着粘结界面的破坏,端柱-剪力墙的端柱和腹板分离为仅由钢筋连接的相对独立构件,一侧端柱为全截面受拉,另一侧端柱受弯破坏,新增墙体发生斜压破坏,而整浇剪力墙发生全截面协同工作的受弯破坏。据此提出了水平承载力的简化分析模型和计算公式,计算结果与数值分析结果吻合较好。 展开更多
关键词 框架结构加固 抗震加固 新老混凝土界面本构关系 新增剪力墙加固
下载PDF
基于材料应变的新型装配式剪力墙变形指标限值
14
作者 樊禹江 陈玉喜 +2 位作者 李寰芳 许锦宝 葛俊 《哈尔滨工业大学学报》 北大核心 2025年第2期104-112,共9页
为研究新型装配式剪力墙的抗震性能及其变形指标限值,基于课题组所做新型装配式剪力墙抗震性能试验,采用析因法,共设计216个不同剪跨比、轴压比、边缘构件纵筋配筋率等新型装配式剪力墙模型,完成相应的单推性能研究;基于有限元破坏形态... 为研究新型装配式剪力墙的抗震性能及其变形指标限值,基于课题组所做新型装配式剪力墙抗震性能试验,采用析因法,共设计216个不同剪跨比、轴压比、边缘构件纵筋配筋率等新型装配式剪力墙模型,完成相应的单推性能研究;基于有限元破坏形态识别,将构件破坏形态划分为弯曲破坏、弯剪破坏和剪切破坏3类,提出墙体破坏形态划分准则。参考GB 50011—2010《建筑抗震设计规范》,对弯曲破坏和弯剪破坏划分6个性能状态,对剪切破坏划分两个性能状态,基于构件极限状态下混凝土、钢筋应变和承载力,确定墙体性能状态判定准则。通过线性回归分别得到弯曲破坏、弯剪破坏和剪切破坏形态下构件各塑性位移角限值的回归方程,并提出各破坏形态下具有90%保证率的构件变形指标限值标准,为基于性能的新型装配式剪力墙抗震设计提供参考。 展开更多
关键词 钢筋混凝土 装配式剪力墙 有限元模拟 破坏形态 变形指标限值
下载PDF
Performance evaluation of low-rise infilled reinforced concrete frames designed by considering local effects on column shear demand
15
作者 Jarun SRECHAI Wongsa WARARUKSAJJA +1 位作者 Sutat LEELATAVIWAT Suchart LIMKATANYU 《Frontiers of Structural and Civil Engineering》 SCIE EI CSCD 2023年第5期686-703,共18页
The interactions between reinforced concrete(RC)frames and infill walls play an important role in the seismic response of frames,particularly for low-rise frames.Infill walls can increase the overall lateral strength ... The interactions between reinforced concrete(RC)frames and infill walls play an important role in the seismic response of frames,particularly for low-rise frames.Infill walls can increase the overall lateral strength and stiffness of the frame owing to their high strength and stiffness.However,local wall-frame interactions can also lead to increased shear demand in the columns owing to the compressive diagonal strut force from the infill wall,which can result in failure or in serious situations,collapse.In this study,the effectiveness of a design strategy to consider the complex infill wall interaction was investigated.The approach was used to design example RC frames with infill walls in locations with different seismicity levels in Thailand.The performance of these frames was assessed using nonlinear static,and dynamic analyses.The performance of the frames and the failure modes were compared with those of frames designed without considering the infill wall or the local interactions.It was found that even though the overall responses of the buildings designed with and without consideration of the local interaction of the infill walls were similar in terms the overall lateral strength,the failure modes were different.The proposed method can eliminate the column shear failure from the building.Finally,the merits and limitations of this approach are discussed and summarized. 展开更多
关键词 reinforced concrete frames infill wall seismic design method shear failure wall-frame interaction
原文传递
钢板混凝土墙-钢筋混凝土楼板连接节点抗剪性能
16
作者 于跃 隋春光 +1 位作者 雷永旺 郭全全 《哈尔滨工业大学学报》 EI CAS 北大核心 2025年第1期92-100,共9页
模块化技术正在推动新一代核电厂的设计和发展,兼具优良工作性能和工业化施工性能的钢板混凝土(SC)结构在模块化结构具有广泛应用前景。SC墙-RC楼板连接节点作为SC模块结构与RC结构之间的典型传力构件,其结构设计必须既要保证荷载的有... 模块化技术正在推动新一代核电厂的设计和发展,兼具优良工作性能和工业化施工性能的钢板混凝土(SC)结构在模块化结构具有广泛应用前景。SC墙-RC楼板连接节点作为SC模块结构与RC结构之间的典型传力构件,其结构设计必须既要保证荷载的有效传递,又要考虑模块化施工的可行性。为研究SC墙-RC楼板连接节点抗剪性能,设计并完成了2个“薄墙厚板型”SC墙-RC楼板连接节点循环加载试验,包括GB/T 51340—2018建议的钢筋连接器连接、附加抗剪键等两种连接方式。试验结果表明:在剪跨比1.50下试件均发生RC楼板弯剪破坏,节点主要传力破坏路径为加载端至楼板根部的斜压杆区域,说明节点结合面不配置抗剪键仍满足抗剪要求;试验过程中,直螺纹钢筋套筒无滑脱、未发生钢筋或焊缝拉断,延性系数均大于4,说明钢筋连接器连接的传力性能良好,可作为SC墙-RC楼板连接节点的有效连接方式;该节点核心区仍属于抗剪薄弱区域,若要满足“全强度连接”设计准则,核心区对拉筋体积含钢率应不低于0.59%。 展开更多
关键词 钢板混凝土墙 钢筋混凝土楼板 连接节点 钢筋连接器 抗剪键
下载PDF
外包钢板加固震损钢绞线-钢筋混凝土剪力墙抗震性能试验研究
17
作者 袁维光 赵军 孙玉平 《建筑结构》 北大核心 2025年第1期73-78,共6页
基于震后建筑结构快速修复并投入使用的需求,提出了外包钢板加固震损钢绞线-钢筋混凝土剪力墙的方法。设计并制作了2个足尺的钢绞线-钢筋混凝土剪力墙,先通过拟静力试验模拟了其在罕遇地震作用下的预损伤,在此预震损的基础上,采用外包... 基于震后建筑结构快速修复并投入使用的需求,提出了外包钢板加固震损钢绞线-钢筋混凝土剪力墙的方法。设计并制作了2个足尺的钢绞线-钢筋混凝土剪力墙,先通过拟静力试验模拟了其在罕遇地震作用下的预损伤,在此预震损的基础上,采用外包钢板对钢绞线-钢筋混凝土剪力墙进行加固,然后再次进行低周往复加载试验,研究其抗震性能和可恢复性能。试验结果表明:修复加固后试件的水平荷载仍能随其侧向变形的增大而持续增加,表现出较好的正刚性,在大震作用下采用外包钢板修复加固后剪力墙的承载能力和变形能力分别提高约3%和15%,轴压比较高时外包钢板加固效果更好;在位移角达到2%前,修复加固后的试件与原试件的残余变形曲线基本重合,且残余变形小于0.5%,具有良好的自复位能力。 展开更多
关键词 钢绞线-钢筋混凝土剪力墙 外包钢板 拟静力试验 抗震性能 残余变形
下载PDF
HPC端部加强双钢板组合剪力墙的抗震性能
18
作者 袁朝庆 李国洋 +2 位作者 代晓辉 房宽光 计静 《黑龙江科技大学学报》 CAS 2024年第1期61-68,共8页
为研究高性能混凝土端部加强双钢板组合剪力墙受力机理及破坏形态,以轴压比、腹部普通混凝土强度等级为关键参数,设计了4片普通试件,7片HPC端部加强试件,运用ABAQUS构建其有限元模型,研究其抗震性能。结果表明:同轴压比下,HPC端部加强... 为研究高性能混凝土端部加强双钢板组合剪力墙受力机理及破坏形态,以轴压比、腹部普通混凝土强度等级为关键参数,设计了4片普通试件,7片HPC端部加强试件,运用ABAQUS构建其有限元模型,研究其抗震性能。结果表明:同轴压比下,HPC端部加强试件相比普通试件屈服荷载提高16.30%,峰值荷载提升13.40%;随着轴压比提高,HPC端部加强试件峰值荷载和屈服荷载分别提高7.22%和2.72%,随着轴压比减小,HPC端部加强试件延性提升22.26%;提高腹部腔体混凝土强度等级,HPC端部加强试件的屈服荷载和峰值荷载分别提高13.01%和11.14%,延性提升16.91%。 展开更多
关键词 HPC端部加强 双钢板组合剪力墙 抗震性能
下载PDF
单钢板混凝土剪力墙结构钢筋工程施工策划及实施
19
作者 李铁兵 李海兵 +2 位作者 韩冰洋 李佳傲 王克 《建筑技术》 2024年第13期1552-1556,共5页
单钢板混凝土剪力墙结构是钢-混凝土组合剪力墙结构形式中的一种,可通过钢结构与钢筋混凝土结构的协同工作,充分发挥各自的优势。在钢筋混凝土剪力墙结构中配置端部型钢和钢板,会造成钢结构与混凝土结构相互交叉影响,改变钢筋混凝土剪... 单钢板混凝土剪力墙结构是钢-混凝土组合剪力墙结构形式中的一种,可通过钢结构与钢筋混凝土结构的协同工作,充分发挥各自的优势。在钢筋混凝土剪力墙结构中配置端部型钢和钢板,会造成钢结构与混凝土结构相互交叉影响,改变钢筋混凝土剪力墙的施工工艺,因此要提前策划、采取应对措施,在满足结构设计和规范要求的前提下,做到钢结构快速精准安装,为后续插入钢筋绑扎工程创造条件,合理预留与钢筋工程的连接条件。钢筋骨架设置于钢结构外侧,要解决钢筋垂直于钢结构受到阻挡时采取的穿越/连接节点作法,以及整体钢筋施工工艺的梳理,使钢筋绑扎工程能够既符合要求,又能快速、有序安装,提高功效、保证质量。 展开更多
关键词 单钢板混凝土剪力墙 钢筋工程 优化
下载PDF
钢板混凝土剪力墙拉弯剪性能试验研究 被引量:1
20
作者 蒙春丽 柯晓军 +1 位作者 苏益声 梁胤鸿 《工程力学》 EI CSCD 北大核心 2024年第5期146-154,共9页
超高层建筑“细柔”特征容易引起底部剪力墙在强震下处于拉-弯-剪复合受力状态,中国《超限高层建筑工程抗震设防专项审查技术要点》(建质[2015]67号)建议墙肢采用配置型钢/钢板的方式来改善该种抗震性能,但缺乏相关试验研究。为此,进行... 超高层建筑“细柔”特征容易引起底部剪力墙在强震下处于拉-弯-剪复合受力状态,中国《超限高层建筑工程抗震设防专项审查技术要点》(建质[2015]67号)建议墙肢采用配置型钢/钢板的方式来改善该种抗震性能,但缺乏相关试验研究。为此,进行了6片钢板混凝土剪力墙的低周往复荷载试验,研究了轴拉比、含钢率及剪跨比对墙肢拉弯剪性能的影响。研究表明:拉弯剪作用引起钢板混凝土剪力墙密集的裂缝分布和显著的钢材强化,并导致其剪切-拉弯耦合破坏。轴拉比增大,墙肢承载力、初始抗侧刚度和延性分别降低22%、41%和39%;剪跨比减小,墙肢承载力和抗侧刚度至少提升23%;同时增大含钢率和降低剪跨比,墙肢延性提高10%。相比其他国家规范,中国规范对拉弯剪作用下钢板混凝土剪力墙的抗剪承载力预测效果更好,但其未能考虑高含钢率对裂面销栓力的影响,故建议采用暗柱的初始含钢率进行修正。 展开更多
关键词 钢板混凝土剪力墙 低周往复荷载 拉弯剪性能 剪切-拉弯耦合破坏 承载力
下载PDF
上一页 1 2 35 下一页 到第
使用帮助 返回顶部