Background: The availability of premium intraocular lenses (IOL), including toric, multifocal, and EDOF, has become very sophisticated and now demands accurate biometric measurement accuracy. The Pentacam AXL and IOL ...Background: The availability of premium intraocular lenses (IOL), including toric, multifocal, and EDOF, has become very sophisticated and now demands accurate biometric measurement accuracy. The Pentacam AXL and IOL Master 700 are often used for optical biometry and they are available in the market today. They can also be used to measure the parameters needed in the IOL calculation using the latest generation formulas, such as the Barett Universal II. Therefore, this study aims to compare the accuracy of refraction results between Pentacam AXL compared to IOL Master 700 after cataract surgery with the Barett Universal-II formula. Method: A total of 64 eyes from 64 patients who had a preoperative examination with IOL Master 700 and Pentacam AXL were included in this study. Parameters such as K, ACD, LT, WTW, and AL were then compared between the two tools. Prediction error values were also calculated and compared based on the difference between the Spherical equivalent (SE) of subjective refraction results after 4 weeks of surgery with their refractive prediction targets. Results: There was no statistically significant difference in the parameters measured from the two tools except ACD and WTW. Furthermore, LT was difficult to obtain on the Pentacam AXL due to penetration problems, as well as in patients with significant lens opacities. The percentage of error prediction values that reach ± 0.50 D on Pentacam AXL and IOL Master 700 was 70.3% and 73.5%, respectively. However, the average prediction error that was close to emmetropia with IOL Master 700 was greater compared to the other tool. Conclusion: Pentacam AXL has a fairly good accuracy for refraction prediction compared to IOL Master 700. However, it is still necessary to optimize its constants to obtain optimal results.展开更多
AIM:To analyze and compare the differences among ocular biometric parameters in Han and Uyghur populations undergoing cataract surgery.METHODS:In this hospital-based prospective study,410 patients undergoing cataract ...AIM:To analyze and compare the differences among ocular biometric parameters in Han and Uyghur populations undergoing cataract surgery.METHODS:In this hospital-based prospective study,410 patients undergoing cataract surgery(226 Han patients in Tianjin and 184 Uyghur patients in Xinjiang)were enrolled.The differences in axial length(AL),anterior chamber depth(ACD),keratometry[steep K(Ks)and flat K(Kf)],and corneal astigmatism(CA)measured using IOL Master 700 were compared between Han and Uyghur patients.RESULTS:The average age of Han patients was higher than that of Uyghur patients(70.22±8.54 vs 63.04±9.56y,P<0.001).After adjusting for age factors,Han patients had longer AL(23.51±1.05 vs 22.86±0.92 mm,P<0.001),deeper ACD(3.06±0.44 vs 2.97±0.37 mm,P=0.001),greater Kf(43.95±1.40 vs 43.42±1.69 D,P=0.001),steeper Ks(45.00±1.47 vs 44.26±1.71 D,P=0.001),and higher CA(1.04±0.68 vs 0.79±0.65,P=0.025)than Uyghur patients.Intra-ethnic male patients had longer AL,deeper ACD,and lower keratometry than female patients;however,CA between the sexes was almost similar.In the correlation analysis,we observed a positive correlation between AL and ACD in patients of both ethnicities(rHan=0.48,rUyghur=0.44,P<0.001),while AL was negatively correlated with Kf(rHan=-0.42,rUyghur=-0.64,P<0.001)and Ks(rHan=-0.38,rUyghur=-0.66,P<0.001).Additionally,Kf was positively correlated with Ks(rHan=0.89,rUyghur=0.93,P<0.001).CONCLUSION:There are differences in ocular biometric parameters between individuals of Han ethnicity in Tianjin and those of Uyghur ethnicity in Xinjiang undergoing cataract surgery.These ethnic variances can enhance our understanding of ocular diseases related to these parameters and provide guidance for surgical procedures.展开更多
文摘Background: The availability of premium intraocular lenses (IOL), including toric, multifocal, and EDOF, has become very sophisticated and now demands accurate biometric measurement accuracy. The Pentacam AXL and IOL Master 700 are often used for optical biometry and they are available in the market today. They can also be used to measure the parameters needed in the IOL calculation using the latest generation formulas, such as the Barett Universal II. Therefore, this study aims to compare the accuracy of refraction results between Pentacam AXL compared to IOL Master 700 after cataract surgery with the Barett Universal-II formula. Method: A total of 64 eyes from 64 patients who had a preoperative examination with IOL Master 700 and Pentacam AXL were included in this study. Parameters such as K, ACD, LT, WTW, and AL were then compared between the two tools. Prediction error values were also calculated and compared based on the difference between the Spherical equivalent (SE) of subjective refraction results after 4 weeks of surgery with their refractive prediction targets. Results: There was no statistically significant difference in the parameters measured from the two tools except ACD and WTW. Furthermore, LT was difficult to obtain on the Pentacam AXL due to penetration problems, as well as in patients with significant lens opacities. The percentage of error prediction values that reach ± 0.50 D on Pentacam AXL and IOL Master 700 was 70.3% and 73.5%, respectively. However, the average prediction error that was close to emmetropia with IOL Master 700 was greater compared to the other tool. Conclusion: Pentacam AXL has a fairly good accuracy for refraction prediction compared to IOL Master 700. However, it is still necessary to optimize its constants to obtain optimal results.
基金Supported by Tianjin Higher Education Commission Science and Technology Development Fund Project(No.2022ZD057)Tianjin Binhai New Area Health Commission Science and Technology Project(No.2022BWKZ003)+4 种基金Tianjin Key Laboratory of Retinal Function and Disease Open Project(No.2021tjswmm002)Tianjin Health Researh(No.TJWJ2023ZD002)General Project of Natural Science Foundation of Xinjiang Uygur Autonomous Region(No.2020D01A06)Special Fund for Youth of Clinical Research Center in Tianjin Medical University Eye Hospital(No.2020QN02)Tianjin Key Medical Discipline(Specialty)Construction Project(No.TJYXZDXK-037A)。
文摘AIM:To analyze and compare the differences among ocular biometric parameters in Han and Uyghur populations undergoing cataract surgery.METHODS:In this hospital-based prospective study,410 patients undergoing cataract surgery(226 Han patients in Tianjin and 184 Uyghur patients in Xinjiang)were enrolled.The differences in axial length(AL),anterior chamber depth(ACD),keratometry[steep K(Ks)and flat K(Kf)],and corneal astigmatism(CA)measured using IOL Master 700 were compared between Han and Uyghur patients.RESULTS:The average age of Han patients was higher than that of Uyghur patients(70.22±8.54 vs 63.04±9.56y,P<0.001).After adjusting for age factors,Han patients had longer AL(23.51±1.05 vs 22.86±0.92 mm,P<0.001),deeper ACD(3.06±0.44 vs 2.97±0.37 mm,P=0.001),greater Kf(43.95±1.40 vs 43.42±1.69 D,P=0.001),steeper Ks(45.00±1.47 vs 44.26±1.71 D,P=0.001),and higher CA(1.04±0.68 vs 0.79±0.65,P=0.025)than Uyghur patients.Intra-ethnic male patients had longer AL,deeper ACD,and lower keratometry than female patients;however,CA between the sexes was almost similar.In the correlation analysis,we observed a positive correlation between AL and ACD in patients of both ethnicities(rHan=0.48,rUyghur=0.44,P<0.001),while AL was negatively correlated with Kf(rHan=-0.42,rUyghur=-0.64,P<0.001)and Ks(rHan=-0.38,rUyghur=-0.66,P<0.001).Additionally,Kf was positively correlated with Ks(rHan=0.89,rUyghur=0.93,P<0.001).CONCLUSION:There are differences in ocular biometric parameters between individuals of Han ethnicity in Tianjin and those of Uyghur ethnicity in Xinjiang undergoing cataract surgery.These ethnic variances can enhance our understanding of ocular diseases related to these parameters and provide guidance for surgical procedures.