Purpose: To retrospectively evaluate the prevalence of fracture and fragment embolization of inferior vena cava (IVC) filters. Methods: Electronic medical records and imaging studies of all Kaiser Permanente patients ...Purpose: To retrospectively evaluate the prevalence of fracture and fragment embolization of inferior vena cava (IVC) filters. Methods: Electronic medical records and imaging studies of all Kaiser Permanente patients who received IVC filters from August 2000 until August 2010 were retrospectively reviewed for filter complications. Results: 283 patients received an IVC filter during the study period. 143 patients were deceased, while 140 are living. Among deceased patients, the average age at the time of death was 69.8 ± 15.3 [range: 24.7 - 99.2] years;55.9% were men;the mean implantation-to-image time was 13.6 ± 20.6 [range: 0 - 92.4] months, and there were no reported major complications attributable to filter migration or fracture at a mean of 16.8 ± 24.8 [range: 0 - 119.6] months following implantation. One of 14 (7.1%) G2 filters perforated the aorta, which already had a stent graft in place. Among those patients still living, the average age was 67.3 ± 15.2 [range: 15.2 - 97.3] years, 47.1% were men, the mean implantation-to-image time was 33.3 ± 36.5 [range: 0.1-141.7] months, and there were no reported major complications at a mean of 35.3 ± 36.5 [range: 0 - 141.7] months following implantation. Three of 60 (5.0%) Trapease filters were found to have at least 1 strut fracture. There were no cases of filter migration or fragment embolization. The overall fracture rate of all filters with an implantation-to-image-time greater than two years (mean implantation-to-image time 4.7 ± 2.7 [range: 2.0 - 11.8] years) was 3 of 67 (4.5%). Bard G2 and G2X filters had a 0% fracture and embolization rate at a mean of 19.0 ± 16.6 [range: 0.07 - 49.5] months after implantation. Conclusions: IVC filters, regardless of type, have a low prevalence of fracture and we found no cases of fragment embolization.展开更多
Objective To study and evaluate the treatment of the deep vein thrombosis(DVT) around the renal vein(DVT involving the renal vein and it's surrounding,shortly as DVTAR in our study)by two-positioned filter for cat...Objective To study and evaluate the treatment of the deep vein thrombosis(DVT) around the renal vein(DVT involving the renal vein and it's surrounding,shortly as DVTAR in our study)by two-positioned filter for catheter thrombectomy assisted with a Fogarty balloon.Methods We retrospectivly analysed seven cases of DVTAR and by comparison to elicit the respective effect different methods in DVT treatment.The methods used were:1.direct thrombectomy 2.thrombectomy facillitated by blocking of blood flow with a balloon 3.direct thrombolysis via Peripheral vein and 4.thrombectomy with simultaneous placement of a two-positioned filter with a Fogarty balloon and followed by intubation thrombolysis.Result Segmental pulmonary embolism(PE)or thrombosis in vena cava were still observed by CT angiography(CTA)or venography in those cases treated with the first three methods.As for the 3 cases where two-positioned filter for catheter thrombectomy with Fogarty balloon was used,neither pulmonary embolism during and after the operation nor thrombosis in the inferior vena cava was observed.Conclusion For DVTAR,thrombectomy with simultaneous placement of a two-positioned filter with a Fogarty balloon and followed by intubation thrombolysis can be regarded as safe and effective.展开更多
文摘Purpose: To retrospectively evaluate the prevalence of fracture and fragment embolization of inferior vena cava (IVC) filters. Methods: Electronic medical records and imaging studies of all Kaiser Permanente patients who received IVC filters from August 2000 until August 2010 were retrospectively reviewed for filter complications. Results: 283 patients received an IVC filter during the study period. 143 patients were deceased, while 140 are living. Among deceased patients, the average age at the time of death was 69.8 ± 15.3 [range: 24.7 - 99.2] years;55.9% were men;the mean implantation-to-image time was 13.6 ± 20.6 [range: 0 - 92.4] months, and there were no reported major complications attributable to filter migration or fracture at a mean of 16.8 ± 24.8 [range: 0 - 119.6] months following implantation. One of 14 (7.1%) G2 filters perforated the aorta, which already had a stent graft in place. Among those patients still living, the average age was 67.3 ± 15.2 [range: 15.2 - 97.3] years, 47.1% were men, the mean implantation-to-image time was 33.3 ± 36.5 [range: 0.1-141.7] months, and there were no reported major complications at a mean of 35.3 ± 36.5 [range: 0 - 141.7] months following implantation. Three of 60 (5.0%) Trapease filters were found to have at least 1 strut fracture. There were no cases of filter migration or fragment embolization. The overall fracture rate of all filters with an implantation-to-image-time greater than two years (mean implantation-to-image time 4.7 ± 2.7 [range: 2.0 - 11.8] years) was 3 of 67 (4.5%). Bard G2 and G2X filters had a 0% fracture and embolization rate at a mean of 19.0 ± 16.6 [range: 0.07 - 49.5] months after implantation. Conclusions: IVC filters, regardless of type, have a low prevalence of fracture and we found no cases of fragment embolization.
基金Supported by the National Natural Science Foundation of China under Grant Nos.6067316760703072(国家自然科学基金)the National Basic Research Program of China under Grant No.2005CB321801(国家重点基础研究发展计划(973))
文摘Objective To study and evaluate the treatment of the deep vein thrombosis(DVT) around the renal vein(DVT involving the renal vein and it's surrounding,shortly as DVTAR in our study)by two-positioned filter for catheter thrombectomy assisted with a Fogarty balloon.Methods We retrospectivly analysed seven cases of DVTAR and by comparison to elicit the respective effect different methods in DVT treatment.The methods used were:1.direct thrombectomy 2.thrombectomy facillitated by blocking of blood flow with a balloon 3.direct thrombolysis via Peripheral vein and 4.thrombectomy with simultaneous placement of a two-positioned filter with a Fogarty balloon and followed by intubation thrombolysis.Result Segmental pulmonary embolism(PE)or thrombosis in vena cava were still observed by CT angiography(CTA)or venography in those cases treated with the first three methods.As for the 3 cases where two-positioned filter for catheter thrombectomy with Fogarty balloon was used,neither pulmonary embolism during and after the operation nor thrombosis in the inferior vena cava was observed.Conclusion For DVTAR,thrombectomy with simultaneous placement of a two-positioned filter with a Fogarty balloon and followed by intubation thrombolysis can be regarded as safe and effective.