In this paper, we present an optimized design method for high-speed embedded image processing system using 32 bit floating-point Digital Signal Processor (DSP) and Complex Programmable Logic Device (CPLD). The DSP...In this paper, we present an optimized design method for high-speed embedded image processing system using 32 bit floating-point Digital Signal Processor (DSP) and Complex Programmable Logic Device (CPLD). The DSP acts as the main processor of the system: executes digital image processing algorithms and operates other devices such as image sensor and CPLD. The CPLD is used to acquire images and achieve complex logic control of the whole system. Some key technologies are introduced to enhance the performance of our system. In particular, the use of DSP/BIOS tool to develop DSP applications makes our program run much more efficiently. As a result, this system can provide an excellent computing platform not only for executing complex image processing algorithms, but also for other digital signal processing or multi-channel data collection by choosing different sensors or Analog-to-Digital (A/D) converters.展开更多
Assuring medical images protection and robustness is a compulsory necessity nowadays.In this paper,a novel technique is proposed that fuses the wavelet-induced multi-resolution decomposition of the Discrete Wavelet Tr...Assuring medical images protection and robustness is a compulsory necessity nowadays.In this paper,a novel technique is proposed that fuses the wavelet-induced multi-resolution decomposition of the Discrete Wavelet Transform(DWT)with the energy compaction of the Discrete Wavelet Transform(DCT).The multi-level Encryption-based Hybrid Fusion Technique(EbhFT)aims to achieve great advances in terms of imperceptibility and security of medical images.A DWT disintegrated sub-band of a cover image is reformed simultaneously using the DCT transform.Afterwards,a 64-bit hex key is employed to encrypt the host image as well as participate in the second key creation process to encode the watermark.Lastly,a PN-sequence key is formed along with a supplementary key in the third layer of the EbHFT.Thus,the watermarked image is generated by enclosing both keys into DWT and DCT coefficients.The fusions ability of the proposed EbHFT technique makes the best use of the distinct privileges of using both DWT and DCT methods.In order to validate the proposed technique,a standard dataset of medical images is used.Simulation results show higher performance of the visual quality(i.e.,57.65)for the watermarked forms of all types of medical images.In addition,EbHFT robustness outperforms an existing scheme tested for the same dataset in terms of Normalized Correlation(NC).Finally,extra protection for digital images from against illegal replicating and unapproved tampering using the proposed technique.展开更多
Parallel computing techniques have been introduced into digital image correlation(DIC) in recent years and leads to a surge in computation speed. The graphics processing unit(GPU)-based parallel computing demonstrated...Parallel computing techniques have been introduced into digital image correlation(DIC) in recent years and leads to a surge in computation speed. The graphics processing unit(GPU)-based parallel computing demonstrated a surprising effect on accelerating the iterative subpixel DIC, compared with CPU-based parallel computing. In this paper, the performances of the two kinds of parallel computing techniques are compared for the previously proposed path-independent DIC method, in which the initial guess for the inverse compositional Gauss-Newton(IC-GN) algorithm at each point of interest(POI) is estimated through the fast Fourier transform-based cross-correlation(FFT-CC) algorithm. Based on the performance evaluation, a heterogeneous parallel computing(HPC) model is proposed with hybrid mode of parallelisms in order to combine the computing power of GPU and multicore CPU. A scheme of trial computation test is developed to optimize the configuration of the HPC model on a specific computer. The proposed HPC model shows excellent performance on a middle-end desktop computer for real-time subpixel DIC with high resolution of more than 10000 POIs per frame.展开更多
基金Supported by the National Natural Science Foundation of China (No.60472046)
文摘In this paper, we present an optimized design method for high-speed embedded image processing system using 32 bit floating-point Digital Signal Processor (DSP) and Complex Programmable Logic Device (CPLD). The DSP acts as the main processor of the system: executes digital image processing algorithms and operates other devices such as image sensor and CPLD. The CPLD is used to acquire images and achieve complex logic control of the whole system. Some key technologies are introduced to enhance the performance of our system. In particular, the use of DSP/BIOS tool to develop DSP applications makes our program run much more efficiently. As a result, this system can provide an excellent computing platform not only for executing complex image processing algorithms, but also for other digital signal processing or multi-channel data collection by choosing different sensors or Analog-to-Digital (A/D) converters.
文摘Assuring medical images protection and robustness is a compulsory necessity nowadays.In this paper,a novel technique is proposed that fuses the wavelet-induced multi-resolution decomposition of the Discrete Wavelet Transform(DWT)with the energy compaction of the Discrete Wavelet Transform(DCT).The multi-level Encryption-based Hybrid Fusion Technique(EbhFT)aims to achieve great advances in terms of imperceptibility and security of medical images.A DWT disintegrated sub-band of a cover image is reformed simultaneously using the DCT transform.Afterwards,a 64-bit hex key is employed to encrypt the host image as well as participate in the second key creation process to encode the watermark.Lastly,a PN-sequence key is formed along with a supplementary key in the third layer of the EbHFT.Thus,the watermarked image is generated by enclosing both keys into DWT and DCT coefficients.The fusions ability of the proposed EbHFT technique makes the best use of the distinct privileges of using both DWT and DCT methods.In order to validate the proposed technique,a standard dataset of medical images is used.Simulation results show higher performance of the visual quality(i.e.,57.65)for the watermarked forms of all types of medical images.In addition,EbHFT robustness outperforms an existing scheme tested for the same dataset in terms of Normalized Correlation(NC).Finally,extra protection for digital images from against illegal replicating and unapproved tampering using the proposed technique.
基金supported by the National Natural Science Foundation of China(Grant Nos.11772131,11772132,11772134&11472109)the Natural Science Foundation of Guangdong Province,China(Grant Nos.2015A030308017,2015A030311046&2015B010131009)+2 种基金the Opening fund of State Key Laboratory of Nonlinear Mechanics(LNM)CASthe State Key Lab of Subtropical Building Science,South China University of Technology(Grant Nos.2014ZC17&2017ZD096)
文摘Parallel computing techniques have been introduced into digital image correlation(DIC) in recent years and leads to a surge in computation speed. The graphics processing unit(GPU)-based parallel computing demonstrated a surprising effect on accelerating the iterative subpixel DIC, compared with CPU-based parallel computing. In this paper, the performances of the two kinds of parallel computing techniques are compared for the previously proposed path-independent DIC method, in which the initial guess for the inverse compositional Gauss-Newton(IC-GN) algorithm at each point of interest(POI) is estimated through the fast Fourier transform-based cross-correlation(FFT-CC) algorithm. Based on the performance evaluation, a heterogeneous parallel computing(HPC) model is proposed with hybrid mode of parallelisms in order to combine the computing power of GPU and multicore CPU. A scheme of trial computation test is developed to optimize the configuration of the HPC model on a specific computer. The proposed HPC model shows excellent performance on a middle-end desktop computer for real-time subpixel DIC with high resolution of more than 10000 POIs per frame.