期刊文献+
共找到15,797篇文章
< 1 2 250 >
每页显示 20 50 100
Development of a 2D spatial displacement estimation method for turbulence velocimetry of the gas puff imaging system on EAST
1
作者 李乐天 刘少承 +2 位作者 颜宁 刘晓菊 高翔 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第3期17-24,共8页
A gas puff imaging(GPI)diagnostic has been developed and operated on EAST since 2012,and the time-delay estimation(TDE)method is used to derive the propagation velocity of fluctuations from the two-dimensional GPI dat... A gas puff imaging(GPI)diagnostic has been developed and operated on EAST since 2012,and the time-delay estimation(TDE)method is used to derive the propagation velocity of fluctuations from the two-dimensional GPI data.However,with the TDE method it is difficult to analyze the data with fast transient events,such as edge-localized mode(ELM).Consequently,a method called the spatial displacement estimation(SDE)algorithm is developed to estimate the turbulence velocity with high temporal resolution.Based on the SDE algorithm,we make some improvements,including an adaptive median filter and super-resolution technology.After the development of the algorithm,a straight-line movement and a curved-line movement are used to test the accuracy of the algorithm,and the calculated speed agrees well with preset speed.This SDE algorithm is applied to the EAST GPI data analysis,and the derived propagation velocity of turbulence is consistent with that from the TDE method,but with much higher temporal resolution. 展开更多
关键词 gas puff imaging spatial displacement estimation SDE edge turbulence velocity TDE EAST tokamak
下载PDF
Development of a toroidal soft x-ray imaging system and application for investigating three-dimensional plasma on J-TEXT
2
作者 赵传旭 李建超 +9 位作者 张晓卿 王能超 丁永华 杨州军 江中和 严伟 李杨波 毛飞越 任正康 the J-TEXT Team 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第3期94-99,共6页
A toroidal soft x-ray imaging(T-SXRI)system has been developed to investigate threedimensional(3D)plasma physics on J-TEXT.This T-SXRI system consists of three sets of SXR arrays.Two sets are newly developed and locat... A toroidal soft x-ray imaging(T-SXRI)system has been developed to investigate threedimensional(3D)plasma physics on J-TEXT.This T-SXRI system consists of three sets of SXR arrays.Two sets are newly developed and located on the vacuum chamber wall at toroidal positionsφof 126.4°and 272.6°,respectively,while one set was established previously atφ=65.50.Each set of SXR arrays consists of three arrays viewing the plasma poloidally,and hence can be used separately to obtain SXR images via the tomographic method.The sawtooth precursor oscillations are measured by T-SXRI,and the corresponding images of perturbative SXR signals are successfully reconstructed at these three toroidal positions,hence providing measurement of the 3D structure of precursor oscillations.The observed 3D structure is consistent with the helical structure of the m/n=1/1 mode.The experimental observation confirms that the T-SXRI system is able to observe 3D structures in the J-TEXT plasma. 展开更多
关键词 SXR imaging J-TEXT tokamak three-dimensional measurement MHD
下载PDF
Fluorescence molecular imaging system and fusion algorithm based on 2CCD camera
3
作者 王玉 王明泉 +1 位作者 杨晓峰 王艳翔 《Journal of Measurement Science and Instrumentation》 CAS CSCD 2016年第2期161-164,共4页
Infrared and visible light images can be obtained simultaneously by building fluorescence imaging system,which includes fluorescence excitation,images acquisition,mechanical part,image transmission and processing sect... Infrared and visible light images can be obtained simultaneously by building fluorescence imaging system,which includes fluorescence excitation,images acquisition,mechanical part,image transmission and processing section.This system studied the 2charge-coupled device(CCD)camera(AD-080CL)of the JAI company.Fusion algorithm of visible light and near infrared images was designed for the fluorescence imaging system with wavelet transform image fusion algorithm.In order to enhance the fluorescent moiety of the fusion image,the luminance value of the green component of the color image was changed.And using microsoft foundation classes(MFC)application architecture,the supporting software system was bulit in VS2010 environment. 展开更多
关键词 fluorescence imaging system image fusion wavelet transform microsoft foundation classes(MFC)
下载PDF
Simulation of Quantum Noise in the Low-Light-Level Imaging System 被引量:3
4
作者 邹正峰 芦汉生 +1 位作者 白廷柱 高稚允 《Journal of Beijing Institute of Technology》 EI CAS 2001年第2期186-190,共5页
A mathematical model of quantum noise having much effect on the low light imaging system is set up. To simulate the quantum noise, the random numbers obeying noise distribution must be formed and are weighted on the... A mathematical model of quantum noise having much effect on the low light imaging system is set up. To simulate the quantum noise, the random numbers obeying noise distribution must be formed and are weighted on the basis of the model created. Three uniform random sequences are built by the linear congruential method, of which two are used to form integer number and decimal fraction parts of the new random sequence respectively and the third to shuffle the new sequence. And then a Gauss sequence is formed out of uniform distribution by a function transforming method. It actualizes the simulation in real time of quantum noise in the low light imaging system, where video flow is extracted in real time, the noise summed up and played back side by side with the original video signs by a simulation software. 展开更多
关键词 SIMULATION quantum noises low light level imaging
下载PDF
An Insect Imaging System to Automate Rice Light-Trap Pest Identification 被引量:23
5
作者 YAO Qing LV Jun +4 位作者 LIU Qing-jie DIAO Guang-qiang YANG Bao-jun CHEN Hong-ming TANGJian 《Journal of Integrative Agriculture》 SCIE CAS CSCD 2012年第6期978-985,共8页
Identification and counting of rice light-trap pests are important to monitor rice pest population dynamics and make pest forecast. Identification and counting of rice light-trap pests manually is time-consuming, and ... Identification and counting of rice light-trap pests are important to monitor rice pest population dynamics and make pest forecast. Identification and counting of rice light-trap pests manually is time-consuming, and leads to fatigue and an increase in the error rate. A rice light-trap insect imaging system is developed to automate rice pest identification. This system can capture the top and bottom images of each insect by two cameras to obtain more image features. A method is proposed for removing the background by color difference of two images with pests and non-pests. 156 features including color, shape and texture features of each pest are extracted into an support vector machine (SVM) classifier with radial basis kernel function. The seven-fold cross-validation is used to improve the accurate rate of pest identification. Four species of Lepidoptera rice pests are tested and achieved 97.5% average accurate rate. 展开更多
关键词 automatic identification imaging system rice light-trap pests SVM cross-validate
下载PDF
Application of Morphological Filter in Rosette Scanning Sub-Imaging System 被引量:2
6
作者 邹立建 王茜倩 刘敬海 《Journal of Beijing Institute of Technology》 EI CAS 2001年第4期418-422,共5页
To restore the sub image in a rosette scanning system and provide target recognition system with a low distorted image, the sub image is processed with morphological filters. Morphological filter can process rosette... To restore the sub image in a rosette scanning system and provide target recognition system with a low distorted image, the sub image is processed with morphological filters. Morphological filter can process rosette scanning sub images more effectively. It can restore the original area and shape of an object effectively, and keep the energy information of the object. To process sub images got by a rosette scanning system, morphological filter is more effective than traditional low pass filter. 展开更多
关键词 morphological filter rosette scanning image processing
下载PDF
Air tamponade in retinal detachment surgery followed by ultra-widefield fundus imaging system 被引量:4
7
作者 Qian-Yin Chen Yun-Xia Tang +6 位作者 Yan-Qiong He Hui-Min Lin Ru-Long Gao Meng-Yuan Li Jin-Tong Hou Hong-Jie Ma Jing-Lin Zhang 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2018年第7期1198-1203,共6页
AIM: To report the surgical result of pars plana vitrectomy(PPV) with air tamponade for rhegmatogenous retinal detachment(RRD) by ultra-widefield fundus imaging system. METHODS: Of 25 consecutive patients(25 e... AIM: To report the surgical result of pars plana vitrectomy(PPV) with air tamponade for rhegmatogenous retinal detachment(RRD) by ultra-widefield fundus imaging system. METHODS: Of 25 consecutive patients(25 eyes) with fresh primary RRD and causative retinal break and vitreous traction were presented. All the patients underwent PPV with air tamponade. Visual acuity(VA) was examined postoperatively and images were captured by ultrawidefield scanning laser ophthalmoscope system(Optos). RESULTS: Initial reattachment was achieved in 25 cases(100%). The air volume was 〉60% on the postoperative day(POD) 1. The ultra-widefield images showed that the retina was reattached in all air-filled eyes postoperatively. The retinal break and laser burns in the superior were detected in 22 of 25 eyes(88%). A missed retinal hole was found under intravitreal air bubble in 1 case(4%). The air volume was range from 40% to 60% on POD 3. A doublelayered image was seen in 25 of 25 eyes with intravitreal gas. Retinal breaks and laser burns around were seen in the intravitreal air. On POD 7, small bubble without effect was seen in 6 cases(24%) and bubble was completely disappeared in 4 cases(16%). Small oval bubble in the superior area was observed in 15 cases(60%). There were no missed and new retinal breaks and no retinal detachment in all cases on the POD 14 and 1 mo and last follow-up. Air disappeared completely on a mean of 9.84 d postoperatively. The mean final postoperative bestcorrected visual acuity(BCVA) was 0.35 log MAR. Mean final postoperative BCVA improved significantly relative to mean preoperative(P〈0.05). Final VA of 0.3 log MAR or better was seen in 13 eyes. CONCLUSION: PPV with air tamponade is an effective management for fresh RRD with superior retinal breaks. The ultra-widefield fundus imaging can detect postoperative retinal breaks in air-filled eyes. It would be a useful facility for follow-up after PPV with air tamponade. Facedown position and acquired visual rehabilitation may be shorten. 展开更多
关键词 rhegmatogenous retinal detachment air tamponade ultra-widefield fundus imaging system
下载PDF
Zynq-7000 SoC-based portable uncooled infrared imaging system 被引量:1
8
作者 PAN Shao-wu LI Xiao-qiong HAN Jie 《Journal of Beijing Institute of Technology》 EI CAS 2016年第3期435-440,共6页
A novel portable infrared imaging system based on uncooled focal plane array and programmable system-on-chip(SoC)was proposed.The latest Xilinx Zynq-7000 was used to integrate the main part of the system into a sing... A novel portable infrared imaging system based on uncooled focal plane array and programmable system-on-chip(SoC)was proposed.The latest Xilinx Zynq-7000 was used to integrate the main part of the system into a single SoC.Parallel arithmetic units and digital modules were implemented on the programmable logic(PL)of Zynq-7000 to decrease system size and ensure the real-time p nonuniformity correction,while programs running on the processing system(PS)of Zynq-7000 controlled the system work flow and provided human-machine interfaces using open-source software such as Linux and OpenCV.Meanwhile,industry standard advanced extendable interface(AXI)buses were adopted to encapsulating standardized IP cores and build high speed data exchange bridges between units within Zynq-7000.Test results indicate that the image quality and real-time performance of the system can meet application requirements.And it provided a more flexible and extendable solution for evaluating and deploying infrared image enhancement and nonuniformity correction algorithms. 展开更多
关键词 infrared imaging system UNCOOLED ZYNQ-7000
下载PDF
Mechanics of bioinspired imaging systems 被引量:1
9
作者 Zhengwei Li Yu Wang Jianliang Xiao 《Theoretical & Applied Mechanics Letters》 CAS CSCD 2016年第1期11-20,共10页
Imaging systems in nature have attracted a lot of research interest due to their superior optical and imaging characteristics, Recent advancements in materials science, mechanics, and stretchable electronics have led ... Imaging systems in nature have attracted a lot of research interest due to their superior optical and imaging characteristics, Recent advancements in materials science, mechanics, and stretchable electronics have led to successful development of bioinspired cameras that resemble the structures and functions of biological light-sensing organs. In this review, we discuss some recent progresses in mechanics of bioinspired imaging systems, including tunable hemispherical eyeball camera and artificial compound eye camera. The mechanics models and results reviewed in this article can provide efficient tools for design and optimization of such systems, as well as other related optoelectronic systems that combine rigid elements with soft substrates. 展开更多
关键词 Mechanics Bioinspired imaging system Eyeball camera Compound eye camera Stretchable electronics
下载PDF
Design of Uncooled Thermal Imaging Systems Operating at Multiple Temperatures
10
作者 张俊举 常本康 钱芸生 《Defence Technology(防务技术)》 SCIE EI CAS 2009年第4期296-301,共6页
The reasons why thermal imaging systems consume power are analyzed,and a low power consumption design scheme is presented for the thermal imaging systems operating at multiple temperatures. The relation between the re... The reasons why thermal imaging systems consume power are analyzed,and a low power consumption design scheme is presented for the thermal imaging systems operating at multiple temperatures. The relation between the response performance of α-Si microbolometer detector and its operating temperature is studied by means of formulas of microbolometer detector's noise equivalent temperature difference(NETD) and detectivity. Numerical analysis based on true parameters demonstrates that the detectivity decreases slightly and NETD increases slightly when operating temperature rises,which indicates that α-Si microbolometer detector has approximately uniform response in a wide operating temperature range. According to these analyses,a thermal imaging system operating at multiple temperatures is designed. The power of thermoelectric stabilizer(TEC) is less than 350 mW and NETD is less than 120 mK in the ambient temperature range of-40 ℃-60 ℃,which shows that this system not only outputs high-quality images but consumes low power. 展开更多
关键词 infared technology thermal imaging system temperature characteristics NETD DETECTIVITY
下载PDF
Real-time and high-transmission middle-infrared optical imaging system based on a pixel-wise metasurface micro-polarization array
11
作者 马丽凤 杜杉 +6 位作者 常军 陈蔚霖 武楚晗 石鑫鑫 黄翼 钟乐 穆全全 《Chinese Physics B》 SCIE EI CAS CSCD 2023年第8期304-309,共6页
Real-time polarization medium-wave infrared(MIR)optical imaging systems enable the acquisition of infrared and polarization information for a target.At present,real-time polarization MIR devices face the following pro... Real-time polarization medium-wave infrared(MIR)optical imaging systems enable the acquisition of infrared and polarization information for a target.At present,real-time polarization MIR devices face the following problems:poor real-time performance,low transmission and high requirements for fabrication and integration.Herein,we aim to improve the performance of real-time polarization imaging systems in the MIR waveband and solve the above-mentioned defects.Therefore,we propose a MIR polarization imaging system to achieve real-time polarization-modulated imaging with high transmission as well as improved performance based on a pixel-wise metasurface micro-polarization array(PMMPA).The PMMPA element comprises several linear polarization(LP)filters with different polarization angles.The optimization results demonstrate that the transmittance of the center field of view for the LP filters is up to 77%at a wavelength of4.0μm and an extinction ratio of 88 d B.In addition,a near-diffraction-limited real-time MIR imaging optical system is designed with a field of view of 5°and an F-number of 2.The simulation results show that an MIR polarization imaging system with excellent real-time performance and high transmission is achieved by using the optimized PMMPA element.Therefore,the method is compatible with the available optical system design technologies and provides a way to realize real-time polarization imaging in MIR wavebands. 展开更多
关键词 REAL-TIME middle infrared optical imaging system metasurface polarization array
下载PDF
Passive ranging and a three-dimensional imaging system through wavefront coding
12
作者 Xing-Xu Zhang Lei Qiao +1 位作者 Ting-Yu Zhao Rong-Sheng Qiu 《Chinese Physics B》 SCIE EI CAS CSCD 2018年第5期234-240,共7页
A single-image passive ranging and three-dimensional(3 D)imaging system with chiral phase encoding was proposed in 2011[Opt.Lett.36,115(2011)].A new theoretical analysis of the system in space domain is presented in t... A single-image passive ranging and three-dimensional(3 D)imaging system with chiral phase encoding was proposed in 2011[Opt.Lett.36,115(2011)].A new theoretical analysis of the system in space domain is presented in this paper.We deduce the analytic relationships between the object distance and the point spread function,and between the object distance and the encoded image,respectively.Both the point spread function and the processed spectrum of the encoded image have two spots,which will rotate with the variation of the object distance.Then the depth map is extracted from the encoded image and it can be used to set up 3 D images.The theoretical analysis is verified by a wavefront coding system with a chiral phase which is generated by a phase-only liquid-crystal spatial light modulator.The phase generated by the liquid-crystal spatial light modulator is more flexible than the fixed phase mask and can be adjusted in real time.It is especially suitable for observing the object with a large depth of field. 展开更多
关键词 imaging systems image processing wavefront encoding
下载PDF
Quantitative Analysis of Cell Tracing by in vivo Imaging System
13
作者 郑俊猛 徐利军 +2 位作者 周鸿敏 张维娜 陈忠华 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2010年第4期541-545,共5页
In vivo imaging system (IVIS) is a new and rapidly expanding technology, which has a wide range of applications in life science such as cell tracing. By counting the number of photons emitted from a specimen, IVIS can... In vivo imaging system (IVIS) is a new and rapidly expanding technology, which has a wide range of applications in life science such as cell tracing. By counting the number of photons emitted from a specimen, IVIS can quantify biological events such as tumor growth. We used B16F10-luc-G5 tumor cells and 20 Babl/C mice injected subcutaneously with B16F10-luc-G5 tumor cells (1×106 in 100 μL) to develop a method to quantitatively analyze cells traced by IVIS in vitro and in vivo, respectively. The results showed a strong correlation between the number of tumor cells and the intensity of bioluminescence signal (R2=0.99) under different exposure conditions in in vitro assay. The results derived from the in vivo experiments showed that tumor luminescence was observed in all mice by IVIS at all days, and there was significant difference (P<0.01) between every two days from day 3 to day 14. Moreover, tumor dynamic morphology could be monitored by IVIS when it was in- visible. There was a strong correlation between tumor volume and bioluminescence signal (R2=0.97) by IVIS. In summary, we demonstrated a way to accurately carry out the quantitative analysis of cells using IVIS both in vitro and in vivo. The data indicate that IVIS can be used as an effective and quantitative method for cell tracing both in vitro and in vivo. 展开更多
关键词 in vivo imaging system cell tracing quantitative analysis
下载PDF
Experimental Detection of Depth of Field for a Thermal Light Lensless Ghost Imaging System
14
作者 高禄 田甲 林海龙 《Chinese Physics Letters》 SCIE CAS CSCD 2015年第1期52-55,共4页
We propose optical experiments to study the depth of field for a thermal light lensless ghost imaging system. It is proved that the diaphragm is an important factor to influence the depth of field, and the ghost image... We propose optical experiments to study the depth of field for a thermal light lensless ghost imaging system. It is proved that the diaphragm is an important factor to influence the depth of field, and the ghost images of two detected objects with longitudinal distance less than the depth of field can be achieved simultaneously. The longitudinal coherence scale of the thermal light lensless ghost imaging determines the depth of field. Theoretical analysis can well explain the experimental results. 展开更多
关键词 Experimental Detection of Depth of Field for a Thermal Light Lensless Ghost imaging system
下载PDF
Oversample Reconstruction Based on a Strong Inter-Diagonal Matrix for an Optical Microscanning Thermal Microscope Imaging System
15
作者 Meijing Gao Ailing Tan +3 位作者 Jie Xu Weiqi Jin Zhenlong Zu Ming Yang 《Journal of Beijing Institute of Technology》 EI CAS 2018年第1期65-73,共9页
Based on a strong inter-diagonal matrix and Taylor series expansions,an oversample reconstruction method was proposed to calibrate the optical micro-scanning error. The technique can obtain regular 2 ×2 microscan... Based on a strong inter-diagonal matrix and Taylor series expansions,an oversample reconstruction method was proposed to calibrate the optical micro-scanning error. The technique can obtain regular 2 ×2 microscanning undersampling images from the real irregular undersampling images,and can then obtain a high spatial oversample resolution image. Simulations and experiments show that the proposed technique can reduce optical micro-scanning error and improve the system's spatial resolution. The algorithm is simple,fast and has low computational complexity. It can also be applied to other electro-optical imaging systems to improve their spatial resolution and has a widespread application prospect. 展开更多
关键词 optical microscanning strong inter-diagonal matrix oversample reconstruction thermal microscope imaging system
下载PDF
Efficacy of a novel auto-fluorescence imaging system with computer-assisted color analysis for assessment of colorectal lesions 被引量:7
16
作者 Hiroko Inomata Naoto Tamai +4 位作者 Hiroyuki Aihara Kazuki Sumiyama Shoichi Saito Tomohiro Kato Hisao Tajiri 《World Journal of Gastroenterology》 SCIE CAS 2013年第41期7146-7153,共8页
AIM:To evaluate the efficacy of computer-assisted color analysis of colorectal lesions using a novel auto-fluorescence imaging(AFI)system to distinguish neoplastic lesions from non-neoplastic lesions and to predict th... AIM:To evaluate the efficacy of computer-assisted color analysis of colorectal lesions using a novel auto-fluorescence imaging(AFI)system to distinguish neoplastic lesions from non-neoplastic lesions and to predict the depth of invasion.METHODS:From January 2013 to April 2013,consecutive patients with known polyps greater than 5 mm in size who were scheduled to undergo endoscopic treatment at The Jikei University Hospital were prospectively recruited for this study.All lesions were evaluated using a novel AFI system,and color-tone sampling was performed in a region of interest determined from narrow band imaging or from chromoendoscopy findings without magnification.The green/red(G/R)ratio for each lesion on the AFI images was calculated automatically using a computer-assisted color analysis system that permits real-time color analysis during endoscopic procedures.RESULTS:A total of 88 patients with 163 lesions were enrolled in this study.There were significant differences in the G/R ratios of hyperplastic polyps(non-neoplastic lesions),adenoma/intramucosal cancer/submucosal(SM)superficial cancer,and SM deep cancer(P<0.0001).The mean±SD G/R ratios were 0.984±0.118in hyperplastic polyps and 0.827±0.081 in neoplastic lesions.The G/R ratios of hyperplastic polyps were significantly higher than those of neoplastic lesions(P<0.001).When a G/R ratio cut-off value of>0.89 was applied to determine non-neoplastic lesions,the sensitivity,specificity,positive predictive value(PPV),negative predictive value(NPV),and accuracy were 83.9%,82.6%,53.1%,95.6%and 82.8%,respectively.For neoplastic lesions,the mean G/R ratio was 0.834±0.080 in adenoma/intramucosal cancer/SM superficial cancer and 0.746±0.045 in SM deep cancer.The G/R ratio of adenoma/intramucosal cancer/SM superficial cancer was significantly higher than that of SM deep cancer(P<0.01).When a G/R ratio cut-off value of<0.77 was applied to distinguish SM deep cancers,the sensitivity,specificity,PPV,NPV,and accuracy were80.0%,84.4%,29.6%,98.1%and 84.1%,respectively.CONCLUSION:The novel AFI system with color analysis was effective in distinguishing non-neoplastic lesions from neoplastic lesions and might allow determination of the depth of invasion. 展开更多
关键词 AUTOFLUORESCENCE imaging COMPUTER-AIDED diagnosis COLON NEOPLASIA COLONOSCOPY
下载PDF
A fast and adaptive method for automatic weld defect detection in various real-time X-ray imaging systems 被引量:10
17
作者 邵家鑫 都东 +2 位作者 石涵 常保华 郭桂林 《China Welding》 EI CAS 2012年第1期8-12,共5页
A first and effective method is proposed to detect weld deject adaptively in various Dypes of real-time X-ray images obtained in different conditions. After weld extraction and noise reduction, a proper template of me... A first and effective method is proposed to detect weld deject adaptively in various Dypes of real-time X-ray images obtained in different conditions. After weld extraction and noise reduction, a proper template of median filter is used to estimate the weld background. After the weld background is subtracted from the original image, an adaptite threshold segmentation algorithm is proposed to obtain the binary image, and then the morphological close and open operation, labeling algorithm and fids'e alarm eliminating algorithm are applied to pracess the binary image to obtain the defect, ct detection result. At last, a fast realization procedure jbr proposed method is developed. The proposed method is tested in real-time X-ray image,s obtairted in different X-ray imaging sutems. Experiment results show that the proposed method is effective to detect low contrast weld dejects with few .false alarms and is adaptive to various types of real-time X-ray imaging systems. 展开更多
关键词 non-destructive testing real-time X-ray imaging weld defect automatie detection
下载PDF
Optical design of common-aperture multispectral and polarization optical imaging system with wide field of view 被引量:3
18
作者 Xin Liu Jun Chang +3 位作者 Shuai Feng Yu Mu Xia Wang Zhao-Peng Xu 《Chinese Physics B》 SCIE EI CAS CSCD 2019年第8期119-123,共5页
Multispectral and polarization cameras that can simultaneously acquire the spatial,spectral,and polarization characteristics of an object have considerable potential applications in target detection,biomedical imaging... Multispectral and polarization cameras that can simultaneously acquire the spatial,spectral,and polarization characteristics of an object have considerable potential applications in target detection,biomedical imaging,and remote sensing.In this work,we develop a common-aperture optical system that can capture multispectral and polarization information.An off-axis three-mirror optical system is mounted on the front end of the proposed system and used as a common-aperture telescope in the visible light(400 nm-750 nm)and long-wave infrared(LWIR,8μm-12μm)waveband.The system can maintain a wide field of view(4.5°)and it can demonstrate an enhanced identification ability.The off-axis three-mirror system gets rid of central obscuration while further yielding stable system resolution and energy.Light that has passed through the front-end common-aperture reflection system is divided into the visible light and LWIR waveband by a beamsplitter.The two wavebands then converge on two detectors through two groups of lenses.Our simulation results indicate that the proposed system can obtain clear images in each waveband to meet the diverse imaging requirements. 展开更多
关键词 optical design common-aperture MULTISPECTRAL imaging POLARIZATION imaging
下载PDF
ARRAY PULSED EDDY CURRENT IMAGING SYSTEM USED TO DETECT CORROSION 被引量:4
19
作者 YangBinfeng LuoFeilu CaoXiongheng XuXiaojie 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2005年第2期196-198,共3页
A theory model is established to describe the voltage-current responsefunction. The peak amplitude and the zero-crossing time of the transient signal is extracted as theimaging features, array pulsed eddy current (PEC... A theory model is established to describe the voltage-current responsefunction. The peak amplitude and the zero-crossing time of the transient signal is extracted as theimaging features, array pulsed eddy current (PEC) imaging is proposed to detect corrosion. The testresults show that this system has the advantage of fast scanning speed, different imaging mode andquantitative detection, it has a broad application in the aviation nondestructive testing. 展开更多
关键词 Array probe Pulsed eddy current Aircraft structure Corrosion imaging
下载PDF
Low-cost photoacoustic imaging systems based on laser diode and light-emitting diode excitation 被引量:2
20
作者 Qingkai Yao Yu Ding +1 位作者 Guodong Liu Lvming Zeng 《Journal of Innovative Optical Health Sciences》 SCIE EI CAS 2017年第4期4-16,共13页
Photoacoustic imaging,an emerging biomedical imaging modality,holds great promise for preclinical and clinical researches.It combines the high optical contrast and high ultrasound resolution by converting laser excita... Photoacoustic imaging,an emerging biomedical imaging modality,holds great promise for preclinical and clinical researches.It combines the high optical contrast and high ultrasound resolution by converting laser excitation into ultrasonic emission.In order to generate photoacoustic signal e±-ciently,bulky Q-switched solid-state laser systems are most commonly used as excitation sources and hence limit its commercialization.As an alternative,the miniaturized semiconductor laser system has the advantages of being inexpensive,compact,and robust,which makes a signi¯cant e®ect on production-forming design.It is also desirable to obtain a wavelength in a wide range from visible to nearinfrared spectrum for multispectral applications.Focussing on practical aspect,this paper reviews the state-of-the-art developments of low-cost photoacoustic system with laser diode and light-emitting diode excitation source and highlights a few representative installations in the past decade. 展开更多
关键词 Photoacoustic imaging photoacoustic tomography photoacoustic microscopy laser diode light-emitting diode
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部