DMR-249 A is an indigenously developed high strength low alloy steel for Indian ship building industry for making ship-hull and is extensively used in the construction of war ships and submarines. Welding electrodes c...DMR-249 A is an indigenously developed high strength low alloy steel for Indian ship building industry for making ship-hull and is extensively used in the construction of war ships and submarines. Welding electrodes conforming to SFA 5.5 AWS E8018 C1 has been indigenously developed for welding of this steel using shielded metal arc welding process. In the present study, susceptibility to hydrogen assisted cracking of DMR-249 A steel welds made using this electrode has been assessed using implant test. Implant tests were conducted using this electrode at two different levels of diffusible hydrogen, measured using gas chromatography technique. It is observed that both the steel and the welding consumable are not susceptible to hydrogen assisted cracking even with a high diffusible hydrogen level of 9 m L/100 g of weld metal. In implant tests, specimen did not fracture even after loading to stress levels higher than the yield strength of the base metal. The good resistance of this steel and the welding consumable, even with high levels of diffusible hydrogen, is attributed to absence of a susceptible microstructure in both the weld metal and heat affected zone. Hence, this study shows that, in the absence of a susceptible microstructure, hydrogen assisted cracking is unlikely to occur even if hydrogen level is high. It also confirms that in welding of DMR-249 A with indigenously developed E8018 C1 electrode, hydrogen assisted cracking is not a concern and no preheating is required to avoid it during welding.展开更多
Peri-implantitis has been defined as an inflamematory condition involving dental implants, surrounding mucosa and bone, which lose supporting bone. Although high success rates for endosseous implants have been reporte...Peri-implantitis has been defined as an inflamematory condition involving dental implants, surrounding mucosa and bone, which lose supporting bone. Although high success rates for endosseous implants have been reported, failures occur, and some implants are lost or removed. At least 10% of the failures have been suggested to be the result of peri-implantitis. One of the major causes of the peri-implantitis is the bacterial colonization of implant surfaces but additional risk factors such as periodontitis, poor oral hygiene, tobacco consumption, prepost operative therapies and genetic susceptibility should be considered. In the present study a real-time PCR bases assay was designed to detect and quantify red complex species, then used to investigate 307 periodontal pocket samples from 127 periodontitis patients and 180 controls. Results demonstrated a significant higher prevalence of red complex species and increased amount of Porphyromonas gingivalis and Treponema denticolain periodontal pocket of periodontitis. Since a higher risk of peri-implantitis occurs in periodontally affected patients, detection and treatment of bacteria is a fundamental objective to ensure dental implant survival.展开更多
Aim: Intervertebral spacers for anterior spine fusion are made of different materials, which can affect the post-fusion MRI scans. Suscep- tibility artifacts specially for implants made of titanium alloys can decrease...Aim: Intervertebral spacers for anterior spine fusion are made of different materials, which can affect the post-fusion MRI scans. Suscep- tibility artifacts specially for implants made of titanium alloys can decrease the image quality. This study focused on the influence of deter-mined implant parameters like shape and implant volume in MRI artifacting independent from se-lected MRI-sequences. Methods: In this study the post-implantation MRI scans of determined cuboids and cylinders were evaluated. All in-terbody test implants were made of titanium alloys. MRI scans were carried out by using T1 TSE sequences. The total artifact volume (TAV) of all examined implants were calculated for sta-tistical t-test correlation and implant volume (IV)/TAV-relation. Results: Considering all ex-amined test implants with an increasing implant size the TAV became significant larger (p<0,001) with simultaneous reduction of the respective IV/TAV-relation. According to an intergroup TAV- correlation for cylinders and cuboids with an equivalent implant volume the cylindric test im-plants demonstrated a significant smaller arti-fact range (p<0,05). Conclusions: Based on these results the MRI artifacts of larger test im-plants were more limited to the to the implant’s direct surroundings. In this connection for im- plants with identical material volumes a cylin- dric shape demonstrated more advantages con- sidering MRI artifacting than cubic forms.展开更多
The influence of different surface coatings of NiTi shape memory allays was examined using in vitro testing methods. Plates of superelastic nickel-titanium shape memory allay ( NiTi ) were coated with calcium phosph...The influence of different surface coatings of NiTi shape memory allays was examined using in vitro testing methods. Plates of superelastic nickel-titanium shape memory allay ( NiTi ) were coated with calcium phosphates ( hydroxyapatite ) by high-temperature plasma-spraying or by dip-coating. The biocompatibility was tested in vitro by cultivation of isolated human granulocytes and whole blood cells. As substrates, pure NiTi, plasma-spray-coated NiTi and dip-coated NiTi were used. Isolated granulocytes showed an increased adhesion to both calcium phosphate-coated NiTi samples. Compared to non-coated NiTi or dip-coated NiTi, the number of dead granulocytes adherent to plasma-sprayed surfaces was significantly increased ( p 〈 0.01 ). Whether the d/f- ferences in apoptosis of granulocytes on dip-coated vs plasma-sprayed coatings observed are due to differences in material surface morphologies has to be analyzed in further studies. Because of the cellular interactions with the coating layers, h is likely that the results obtained are not caused by the underlying NiTi but due to the coating itself.展开更多
Electrochemical behavior of dental implant system before and after clinical use(in vivo and in vitro) was researched by using abutment and titanium fixture.To simulate an oral environment,the samples of clinically use...Electrochemical behavior of dental implant system before and after clinical use(in vivo and in vitro) was researched by using abutment and titanium fixture.To simulate an oral environment,the samples of clinically used and non-used implant systems as a working electrode were exposed to artificial saliva at(36.5±1) ℃.Electrochemical tests were carried out using a potentiostat.After electrochemical test,the corrosion morphology of each sample was investigated by FE-SEM and EDS.The corrosion potential and pitting potential of clinically used implant system are lower than those of non-used implant system,and clinically used implant system exhibits a lower range of passivation,indicating a less degree of inherent resistance against chloride ion.The polarization resistance decreases in the case of clinically used implant system,whereas,Rp for clinically non-used implant system increases compared with clinically used implant system.展开更多
Purpose: This study investigated the attitude of patients, grouped by the Brinkman index, towards smoking by using the Kano Test for Social Nicotine Dependence (KTSND) and their knowledge of peri-implantitis. Methods:...Purpose: This study investigated the attitude of patients, grouped by the Brinkman index, towards smoking by using the Kano Test for Social Nicotine Dependence (KTSND) and their knowledge of peri-implantitis. Methods: The participants were 3093 new patients who visited the Tokyo Medical and Dental University Hospital from January 2012 to December 2013 for an oral implant. The methodology included a questionnaire about sex, age, smoking status, daily average number of cigarettes, years of smoking, knowledge of peri-implantitis, and the KTSND. The patients were grouped according to their smoking status by calculating their Brinkman index (over 200 or not): current smokers with the possibility of nicotine dependence (BI(+)CS), current smokers with no possibility of nicotine dependence (BI(-)CS), ex-smokers (ES), and non-smokers (NS). The Brinkman index is obtained by multiplying one’s daily average number of cigarettes by the number of years they have been smoking. Results: Data were collected from 2182 respondents (response rate = 71%). The KTSND scores of BI(+)CS (16.89 ± 4.26) were significantly higher than the scores of ES (11.99 ± 4.52) and NS (11.53 ± 5.01). In current smokers, there were no significant differences between BI(+)CS and BI(-)CS. The patients replied “I don’t know” about peri-implantitis most often in all groups;however, there were no significant differences between the groups. Discussion: BI(+)CS were more dependent on nicotine in social situations than the other groups were. In Japan, a Brinkman index over 200 is required for a nicotine-dependence management fee to be instituted for health insurance treatment. This is a major concern for young smokers, who may be excluded from treatment because their years of smoking are substantially less. Results revealed that there were no significant differences between BI(+)CS and BI(-)CS. Therefore, it was suggested that the Brinkman index did not sufficiently group the participants.展开更多
目的镍钛形状记忆合金骨植入物临床使用过程中存在镍离子析出的风险,植入物镍离子释放在体内很难直接测试,为此本文建立一种镍钛形状记忆合金骨植入物镍离子释放的体外测试方法。方法选用磷酸盐缓冲盐溶液(phosphate buffer salt soluti...目的镍钛形状记忆合金骨植入物临床使用过程中存在镍离子析出的风险,植入物镍离子释放在体内很难直接测试,为此本文建立一种镍钛形状记忆合金骨植入物镍离子释放的体外测试方法。方法选用磷酸盐缓冲盐溶液(phosphate buffer salt solution,PBS)作为测试液,用于植入物镍离子的浸提,将植入物置于带盖容器中,容器中装有PBS,将容器静置在温度稳定控制的恒温培养箱内(37±1)℃下,静置相应设置的时间点,每个时间点设1组空白试验和3个相同平行试样进行镍释放量测定,分别用石墨炉原子吸收光谱仪(atomic absorption spectrometer,AAS)和电感耦合等离子体质谱仪(inductively coupled plasma mass spectrometry,ICP-MS)设备测试溶液中镍离子浓度。结果随时间推移从器械中释放出来的镍离子浓度整体呈下降趋势,镍离子释放时点为4周时,释放周期结束,AAS测得镍离子释放量平均值为0.37×10^(-3)μg/(cm^(2)·d),累计释放量平均值为10.22×10^(-3)μg/cm^(2)。ICP-MS测得镍离子释放量平均值为0.29×10^(-3)μg/(cm^(2)·d),累计释放量平均值为7.9×10^(-3)μg/cm^(2)。AAS和ICP-MS两种测试方法测试结果差异性不大,结果数据的走势相同说明试验可重复性高。结论此方法可为镍钛形状记忆合金骨植入物的风险评估提供依据,确保植入物在临床使用过程中镍离子的析出不会对人体造成伤害,保证其临床使用的安全性。展开更多
文摘DMR-249 A is an indigenously developed high strength low alloy steel for Indian ship building industry for making ship-hull and is extensively used in the construction of war ships and submarines. Welding electrodes conforming to SFA 5.5 AWS E8018 C1 has been indigenously developed for welding of this steel using shielded metal arc welding process. In the present study, susceptibility to hydrogen assisted cracking of DMR-249 A steel welds made using this electrode has been assessed using implant test. Implant tests were conducted using this electrode at two different levels of diffusible hydrogen, measured using gas chromatography technique. It is observed that both the steel and the welding consumable are not susceptible to hydrogen assisted cracking even with a high diffusible hydrogen level of 9 m L/100 g of weld metal. In implant tests, specimen did not fracture even after loading to stress levels higher than the yield strength of the base metal. The good resistance of this steel and the welding consumable, even with high levels of diffusible hydrogen, is attributed to absence of a susceptible microstructure in both the weld metal and heat affected zone. Hence, this study shows that, in the absence of a susceptible microstructure, hydrogen assisted cracking is unlikely to occur even if hydrogen level is high. It also confirms that in welding of DMR-249 A with indigenously developed E8018 C1 electrode, hydrogen assisted cracking is not a concern and no preheating is required to avoid it during welding.
文摘Peri-implantitis has been defined as an inflamematory condition involving dental implants, surrounding mucosa and bone, which lose supporting bone. Although high success rates for endosseous implants have been reported, failures occur, and some implants are lost or removed. At least 10% of the failures have been suggested to be the result of peri-implantitis. One of the major causes of the peri-implantitis is the bacterial colonization of implant surfaces but additional risk factors such as periodontitis, poor oral hygiene, tobacco consumption, prepost operative therapies and genetic susceptibility should be considered. In the present study a real-time PCR bases assay was designed to detect and quantify red complex species, then used to investigate 307 periodontal pocket samples from 127 periodontitis patients and 180 controls. Results demonstrated a significant higher prevalence of red complex species and increased amount of Porphyromonas gingivalis and Treponema denticolain periodontal pocket of periodontitis. Since a higher risk of peri-implantitis occurs in periodontally affected patients, detection and treatment of bacteria is a fundamental objective to ensure dental implant survival.
文摘Aim: Intervertebral spacers for anterior spine fusion are made of different materials, which can affect the post-fusion MRI scans. Suscep- tibility artifacts specially for implants made of titanium alloys can decrease the image quality. This study focused on the influence of deter-mined implant parameters like shape and implant volume in MRI artifacting independent from se-lected MRI-sequences. Methods: In this study the post-implantation MRI scans of determined cuboids and cylinders were evaluated. All in-terbody test implants were made of titanium alloys. MRI scans were carried out by using T1 TSE sequences. The total artifact volume (TAV) of all examined implants were calculated for sta-tistical t-test correlation and implant volume (IV)/TAV-relation. Results: Considering all ex-amined test implants with an increasing implant size the TAV became significant larger (p<0,001) with simultaneous reduction of the respective IV/TAV-relation. According to an intergroup TAV- correlation for cylinders and cuboids with an equivalent implant volume the cylindric test im-plants demonstrated a significant smaller arti-fact range (p<0,05). Conclusions: Based on these results the MRI artifacts of larger test im-plants were more limited to the to the implant’s direct surroundings. In this connection for im- plants with identical material volumes a cylin- dric shape demonstrated more advantages con- sidering MRI artifacting than cubic forms.
文摘The influence of different surface coatings of NiTi shape memory allays was examined using in vitro testing methods. Plates of superelastic nickel-titanium shape memory allay ( NiTi ) were coated with calcium phosphates ( hydroxyapatite ) by high-temperature plasma-spraying or by dip-coating. The biocompatibility was tested in vitro by cultivation of isolated human granulocytes and whole blood cells. As substrates, pure NiTi, plasma-spray-coated NiTi and dip-coated NiTi were used. Isolated granulocytes showed an increased adhesion to both calcium phosphate-coated NiTi samples. Compared to non-coated NiTi or dip-coated NiTi, the number of dead granulocytes adherent to plasma-sprayed surfaces was significantly increased ( p 〈 0.01 ). Whether the d/f- ferences in apoptosis of granulocytes on dip-coated vs plasma-sprayed coatings observed are due to differences in material surface morphologies has to be analyzed in further studies. Because of the cellular interactions with the coating layers, h is likely that the results obtained are not caused by the underlying NiTi but due to the coating itself.
文摘Electrochemical behavior of dental implant system before and after clinical use(in vivo and in vitro) was researched by using abutment and titanium fixture.To simulate an oral environment,the samples of clinically used and non-used implant systems as a working electrode were exposed to artificial saliva at(36.5±1) ℃.Electrochemical tests were carried out using a potentiostat.After electrochemical test,the corrosion morphology of each sample was investigated by FE-SEM and EDS.The corrosion potential and pitting potential of clinically used implant system are lower than those of non-used implant system,and clinically used implant system exhibits a lower range of passivation,indicating a less degree of inherent resistance against chloride ion.The polarization resistance decreases in the case of clinically used implant system,whereas,Rp for clinically non-used implant system increases compared with clinically used implant system.
文摘Purpose: This study investigated the attitude of patients, grouped by the Brinkman index, towards smoking by using the Kano Test for Social Nicotine Dependence (KTSND) and their knowledge of peri-implantitis. Methods: The participants were 3093 new patients who visited the Tokyo Medical and Dental University Hospital from January 2012 to December 2013 for an oral implant. The methodology included a questionnaire about sex, age, smoking status, daily average number of cigarettes, years of smoking, knowledge of peri-implantitis, and the KTSND. The patients were grouped according to their smoking status by calculating their Brinkman index (over 200 or not): current smokers with the possibility of nicotine dependence (BI(+)CS), current smokers with no possibility of nicotine dependence (BI(-)CS), ex-smokers (ES), and non-smokers (NS). The Brinkman index is obtained by multiplying one’s daily average number of cigarettes by the number of years they have been smoking. Results: Data were collected from 2182 respondents (response rate = 71%). The KTSND scores of BI(+)CS (16.89 ± 4.26) were significantly higher than the scores of ES (11.99 ± 4.52) and NS (11.53 ± 5.01). In current smokers, there were no significant differences between BI(+)CS and BI(-)CS. The patients replied “I don’t know” about peri-implantitis most often in all groups;however, there were no significant differences between the groups. Discussion: BI(+)CS were more dependent on nicotine in social situations than the other groups were. In Japan, a Brinkman index over 200 is required for a nicotine-dependence management fee to be instituted for health insurance treatment. This is a major concern for young smokers, who may be excluded from treatment because their years of smoking are substantially less. Results revealed that there were no significant differences between BI(+)CS and BI(-)CS. Therefore, it was suggested that the Brinkman index did not sufficiently group the participants.
文摘目的镍钛形状记忆合金骨植入物临床使用过程中存在镍离子析出的风险,植入物镍离子释放在体内很难直接测试,为此本文建立一种镍钛形状记忆合金骨植入物镍离子释放的体外测试方法。方法选用磷酸盐缓冲盐溶液(phosphate buffer salt solution,PBS)作为测试液,用于植入物镍离子的浸提,将植入物置于带盖容器中,容器中装有PBS,将容器静置在温度稳定控制的恒温培养箱内(37±1)℃下,静置相应设置的时间点,每个时间点设1组空白试验和3个相同平行试样进行镍释放量测定,分别用石墨炉原子吸收光谱仪(atomic absorption spectrometer,AAS)和电感耦合等离子体质谱仪(inductively coupled plasma mass spectrometry,ICP-MS)设备测试溶液中镍离子浓度。结果随时间推移从器械中释放出来的镍离子浓度整体呈下降趋势,镍离子释放时点为4周时,释放周期结束,AAS测得镍离子释放量平均值为0.37×10^(-3)μg/(cm^(2)·d),累计释放量平均值为10.22×10^(-3)μg/cm^(2)。ICP-MS测得镍离子释放量平均值为0.29×10^(-3)μg/(cm^(2)·d),累计释放量平均值为7.9×10^(-3)μg/cm^(2)。AAS和ICP-MS两种测试方法测试结果差异性不大,结果数据的走势相同说明试验可重复性高。结论此方法可为镍钛形状记忆合金骨植入物的风险评估提供依据,确保植入物在临床使用过程中镍离子的析出不会对人体造成伤害,保证其临床使用的安全性。