AIM:To investigate the changes in choroidal thickness(CT)in high myopic eyes after femtosecond laser-assisted in situ keratomileusis(FS-LASIK)surgery or central hole implantable collamer lens(ICL V4c)implantation usin...AIM:To investigate the changes in choroidal thickness(CT)in high myopic eyes after femtosecond laser-assisted in situ keratomileusis(FS-LASIK)surgery or central hole implantable collamer lens(ICL V4c)implantation using swept-source optical coherence tomography(SS-OCT).METHODS:We examined the right eyes of 116 patients with high myopia who were candidates for FS-LASIK surgery and ICL implantation.Sixty eyes underwent ICL V4c implantation and 56 eyes were subjected to FS-LASIK surgery.The CT was measured with SS-OCT.All data were recorded preoperatively and 2 h,1 wk,1 and 3 mo postoperatively.Other demographic information was collected,including age,sex,uncorrected visual acuity(UCVA),best corrected visual acuity(BCVA),spherical equivalent(SE),intraocular pressure(IOP)and axial length(AL).RESULTS:The UCVA improved in both groups and showed no significant differences between groups.There also were no significant differences between the two groups in postoperative BCVA and SE(P=0.581 and 0.203,respectively).The foveal CTs,inner nasal and outer nasal CTs were significantly thicker at 2 h postoperatively in both groups(P<0.05)but returned to baseline levels in 1 wk;after 1 mo,no significant differences were found relative to the preoperative values.At 3 mo in each group,nine regions showed variations in the CT as compared with preoperative thickening,but only the foveal and nasal area CTs preoperative differences were statistically significant(P<0.05).In addition,there was no significant difference in 9 regions of CT between the two groups at all follow-up times(P>0.05).CONCLUSION:The CTs after ICL implantation and FSLASIK surgery are significantly thicker than those before operation,especially in the foveal and nasal areas,but there is no significant difference between the two methods.展开更多
To improve humor circulation the latest V4c Visian implantable collamer lens (ICL) was designed with a0.36-ram Aquapon. This design also eliminates the need to perform peripheral iridectomy before ICL implantation. ...To improve humor circulation the latest V4c Visian implantable collamer lens (ICL) was designed with a0.36-ram Aquapon. This design also eliminates the need to perform peripheral iridectomy before ICL implantation. Several authors reported rates of secondary surgical intervention related to insufficient vault in the presence or absence of cataract formation and excessive vault in the presence or absence of elevated intraocular pressure (IOP) after ICL insertion. Here, we report a case of rapid progression of a cataract to a hypermature state after implantation of an ICL with an Aquaport.展开更多
Dear Editor,I am Dr.Ye Shen from the Department of Ophthalmology,the First Affiliated Hospital,College of Medicine,Zhejiang University,Hangzhou,China.I write to share my experience of full-vision maintenance in patien...Dear Editor,I am Dr.Ye Shen from the Department of Ophthalmology,the First Affiliated Hospital,College of Medicine,Zhejiang University,Hangzhou,China.I write to share my experience of full-vision maintenance in patient with extrahigh myopia from implantable collamer lens (ICL) to trifocal intraocular lens (IOL) implantation.展开更多
AIM:To compare clinical outcomes and refractive stability of implantable collamer lens(ICL)implantation and femtosecond laser assisted laser in situ keratomileusis(FSLASIK)for high myopia correction.METHODS:The Optica...AIM:To compare clinical outcomes and refractive stability of implantable collamer lens(ICL)implantation and femtosecond laser assisted laser in situ keratomileusis(FSLASIK)for high myopia correction.METHODS:The Optical Quality Analysis System(OQAS)was used to evaluate clinical outcomes objectively after operation for high myopia correction.We compared the two procedures in terms of 1-year changes in uncorrected distance visual acuity(UDVA),corrected distance visual acuity(CDVA),safety index,efficacy index,spherical equivalent,modulation transfer function(MTF)cutoff frequency,strehl ratio(SR)and objective scatter index(OSI).RESULTS:At 1 y postoperatively,the safety indices were 1.33±0.27 in ICL group,and 1.17±0.24 in FS-LASIK group.39.58%in the ICL group and 27.59%in the FS-LASIK group gained CDVA in 2 lines or better than that in preoperative CDVA.The efficacy indices were 1.28±0.22 in ICL group,and 1.13±0.26 in FS-LASIK group.The changes of spherical equivalent from 1 wk to 1 y postoperatively was-0.12±0.37 D in ICL group,and-0.79±0.58 D in FS-LASIK group(P<0.05).Spherical equivalent within±0.50 D was achieved in 97.92%in ICL group and 68.97%in FS-LASIK group.MTF cutoff frequency were higher with ICL as compared to FSLASIK(P<0.05)at each postoperative follow-up stage;for postoperative 1 mo later,SR was statistically significant difference between two groups(P<0.05);with no statistically significant difference in OSI between two groups(P>0.05)in postoperative 3 mo later.CONCLUSION:ICL implantation and FS-LASIK procedures both provide good safety and predictability in high myopia correction.ICL implantation provides better clinical outcomes and refractive stability than FS-LASIK.展开更多
基金Supported by the Cross-disciplinary Research Fund of Shanghai Ninth People’s Hospital,Shanghai Jiao Tong University School of Medicine(No.JYJC201907)。
文摘AIM:To investigate the changes in choroidal thickness(CT)in high myopic eyes after femtosecond laser-assisted in situ keratomileusis(FS-LASIK)surgery or central hole implantable collamer lens(ICL V4c)implantation using swept-source optical coherence tomography(SS-OCT).METHODS:We examined the right eyes of 116 patients with high myopia who were candidates for FS-LASIK surgery and ICL implantation.Sixty eyes underwent ICL V4c implantation and 56 eyes were subjected to FS-LASIK surgery.The CT was measured with SS-OCT.All data were recorded preoperatively and 2 h,1 wk,1 and 3 mo postoperatively.Other demographic information was collected,including age,sex,uncorrected visual acuity(UCVA),best corrected visual acuity(BCVA),spherical equivalent(SE),intraocular pressure(IOP)and axial length(AL).RESULTS:The UCVA improved in both groups and showed no significant differences between groups.There also were no significant differences between the two groups in postoperative BCVA and SE(P=0.581 and 0.203,respectively).The foveal CTs,inner nasal and outer nasal CTs were significantly thicker at 2 h postoperatively in both groups(P<0.05)but returned to baseline levels in 1 wk;after 1 mo,no significant differences were found relative to the preoperative values.At 3 mo in each group,nine regions showed variations in the CT as compared with preoperative thickening,but only the foveal and nasal area CTs preoperative differences were statistically significant(P<0.05).In addition,there was no significant difference in 9 regions of CT between the two groups at all follow-up times(P>0.05).CONCLUSION:The CTs after ICL implantation and FSLASIK surgery are significantly thicker than those before operation,especially in the foveal and nasal areas,but there is no significant difference between the two methods.
基金Supported by the National Research Foundation of Korea(NRF)grant funded by the Korea government(MSIP)(No.2017R1A2B4012327)
文摘To improve humor circulation the latest V4c Visian implantable collamer lens (ICL) was designed with a0.36-ram Aquapon. This design also eliminates the need to perform peripheral iridectomy before ICL implantation. Several authors reported rates of secondary surgical intervention related to insufficient vault in the presence or absence of cataract formation and excessive vault in the presence or absence of elevated intraocular pressure (IOP) after ICL insertion. Here, we report a case of rapid progression of a cataract to a hypermature state after implantation of an ICL with an Aquaport.
基金Supported partly by the General Natural Science Projects,Department of Education,Zhejiang Province,China(No.Y201636718)
文摘Dear Editor,I am Dr.Ye Shen from the Department of Ophthalmology,the First Affiliated Hospital,College of Medicine,Zhejiang University,Hangzhou,China.I write to share my experience of full-vision maintenance in patient with extrahigh myopia from implantable collamer lens (ICL) to trifocal intraocular lens (IOL) implantation.
基金Supported by the Research Grant of Hunan Provincial Health Commission Project(No.C2017037)。
文摘AIM:To compare clinical outcomes and refractive stability of implantable collamer lens(ICL)implantation and femtosecond laser assisted laser in situ keratomileusis(FSLASIK)for high myopia correction.METHODS:The Optical Quality Analysis System(OQAS)was used to evaluate clinical outcomes objectively after operation for high myopia correction.We compared the two procedures in terms of 1-year changes in uncorrected distance visual acuity(UDVA),corrected distance visual acuity(CDVA),safety index,efficacy index,spherical equivalent,modulation transfer function(MTF)cutoff frequency,strehl ratio(SR)and objective scatter index(OSI).RESULTS:At 1 y postoperatively,the safety indices were 1.33±0.27 in ICL group,and 1.17±0.24 in FS-LASIK group.39.58%in the ICL group and 27.59%in the FS-LASIK group gained CDVA in 2 lines or better than that in preoperative CDVA.The efficacy indices were 1.28±0.22 in ICL group,and 1.13±0.26 in FS-LASIK group.The changes of spherical equivalent from 1 wk to 1 y postoperatively was-0.12±0.37 D in ICL group,and-0.79±0.58 D in FS-LASIK group(P<0.05).Spherical equivalent within±0.50 D was achieved in 97.92%in ICL group and 68.97%in FS-LASIK group.MTF cutoff frequency were higher with ICL as compared to FSLASIK(P<0.05)at each postoperative follow-up stage;for postoperative 1 mo later,SR was statistically significant difference between two groups(P<0.05);with no statistically significant difference in OSI between two groups(P>0.05)in postoperative 3 mo later.CONCLUSION:ICL implantation and FS-LASIK procedures both provide good safety and predictability in high myopia correction.ICL implantation provides better clinical outcomes and refractive stability than FS-LASIK.