The deep earth,deep sea,and deep space are the main parts of the national“three deep”strategy,which is in the forefront of the strategic deployment clearly defined in China’s 14th Five-Year Plan(2021-2025)and the L...The deep earth,deep sea,and deep space are the main parts of the national“three deep”strategy,which is in the forefront of the strategic deployment clearly defined in China’s 14th Five-Year Plan(2021-2025)and the Long-Range Objectives Through the Year 2035.It is important to reveal the evolutionary process and mechanism of deep tectonics to understand the earth’s past,present and future.The academic con-notation of Geology in Time has been given for the first time,which refers to the multi-field evolution response process of geological bodies at different time and spatial scales caused by geological processes inside and outside the Earth.Based on the deep in situ detection space and the unique geological envi-ronment of China Jinping Underground Laboratory,the scientific issue of the correlation mechanism and law between deep internal time-varying and shallow geological response is given attention.Innovative research and frontier exploration on deep underground in situ geo-information detection experiments for Geology in Time are designed to be carried out,which will have the potential to explore the driving force of Geology in Time,reveal essential laws of deep earth science,and explore innovative technologies in deep underground engineering.展开更多
On-line chatter detection can avoid unstable cutting through monitoring the machining process.In order to identify chatter in a timely manner,an improved Support Vector Machine(SVM)is developed in this paper,based on ...On-line chatter detection can avoid unstable cutting through monitoring the machining process.In order to identify chatter in a timely manner,an improved Support Vector Machine(SVM)is developed in this paper,based on extracted features.In the SVM model,the penalty factor(e)and the core parameter(g)have important influence on the classification,more than from Kernel Functions(KFs).Hence,first the classification results are conducted using different KFs.Then two methods are presented for exploring the best parameters.The chatter identification results show that the Genetic Algorithm(GA)approach is more suitable for deciding the parameters than the Grid Explore(GE)approach.展开更多
The valuation relation of potential difference with discharging time in Electrical Discharge Machining (EDM) is analyzed theoretically and tested and verified by experiments designed in this paper and the relation bet...The valuation relation of potential difference with discharging time in Electrical Discharge Machining (EDM) is analyzed theoretically and tested and verified by experiments designed in this paper and the relation between potential difference and spark location is induced and analyzed, and proceed by experiments under the condition of onedimension.展开更多
A quite new type of chelating resin Carboxymethylated Polyethylenimine-Polymethylenepolyphenylene Isocyanate(CPPI)is used for the preconcentration of Zn from high salt water such as seawater. The preconcentration is c...A quite new type of chelating resin Carboxymethylated Polyethylenimine-Polymethylenepolyphenylene Isocyanate(CPPI)is used for the preconcentration of Zn from high salt water such as seawater. The preconcentration is controlled through the technique of Flow Injection Analysis(FIA).The concentrated sample solution is then directly transferred to an Inductively Coupled Plasma-Atomic Fluorescence Spectrometer(ICP-AFS)for determination.The detection limit of Zn by the technique is about 0.06 ppb.展开更多
Microfluidic analytical system was developed based on annular flow of phase separation multiphase flow with a ternary water-hydrophilic/hydrophobic organic solvent solution. The analytical system was combined with on-...Microfluidic analytical system was developed based on annular flow of phase separation multiphase flow with a ternary water-hydrophilic/hydrophobic organic solvent solution. The analytical system was combined with on-line luminol chemiluminescence detection for catechin analysis. The water (10 mM phosphate buffer, pH 7.3)-acetonitrile-ethyl acetate mixed solution (3:8:4, volume ratio) containing 60 μM luminol and 2 mM hydrogen peroxide as a carrier was fed into the capillary tube (open-tubular fused-silica, 75 μm inner diameter, 110 cm effective length) at a flow rate of 1.0 μL·min-1. The carrier solution showed stable chemiluminescence as a baseline on the flow chart. Eight catechins were detected as negative peaks for their antioxidant potential with different detection times. The system was applied to analyze the amounts of catechin in commercially available green tea beverages.展开更多
Objective To develop an in situ PCR in combination with flow cytometry (ISPCR-FCM) for monitoring cholera toxin positive Vibrio cholerae. Methods In running this method, 4% paraformaldehyde was used to fix the Vibri...Objective To develop an in situ PCR in combination with flow cytometry (ISPCR-FCM) for monitoring cholera toxin positive Vibrio cholerae. Methods In running this method, 4% paraformaldehyde was used to fix the Vibrio cholerae cells and 1 mg/mL lysozyme for 20 min to permeabilize the cells. Before the PCR thermal cycling, 2.5% glycerol was added into the PCR reaction mixture in order to protect the integrality of the cells. Results A length of 1037bp DNA sequence was amplified, which is specific for the cholera toxin gene (ctxAB gene). Cells subjected to ISPCR showed the presences of ctxAB gene both in epifluorescence microscopy and in flow cytometric analysis. The specificity and sensitivity of the method were investigated. The sensitivity was relatively low (10^5 cells/mL), while the specificity was high. Conclusion We have successfully developed a new technique for detection of toxigenic Vibrio cholerae strains. Further study is needed to enhance its sensitivities. ISPCR-FCM shows a great promise in monitoring specific bacteria and their physiological states in environmental samples.展开更多
Objective:To evaluate the diagnostic value of fluorescence in situ hybridization(FISH)in bladder cancer.Methods:We enrolled healthy volunteers and patients who were clinically suspected to have bladder cancer and cond...Objective:To evaluate the diagnostic value of fluorescence in situ hybridization(FISH)in bladder cancer.Methods:We enrolled healthy volunteers and patients who were clinically suspected to have bladder cancer and conducted FISH tests and cytology examinations from August 2007 to December 2008.Receiver operating characteristic(ROC)curve analysis was performed and the area under curve(AUC)values were calculated for both the FISH and urine cytology tests.Results:A cohort of 988 healthy volunteers was enrolled to establish a reference range for the normal population.A total of 4807 patients with hematuria were prospectively,randomly enrolled for the simultaneous analysis of urine cytology,FISH testing,and a final diagnosis as determined by the pathologic findings of a biopsy or a surgically-excised specimen.Overall,the sensitivity of FISH in detecting transitional-cell carcinoma was 82.7%,while that of cytology was 33.4%(p<0.001).The sensitivity values of FISH for non-muscle invasive and muscle invasive bladder transitional-cell carcinoma were 81.7%and 89.6%,respectively(p=0.004).The sensitivity values of FISH for low and high grade bladder cancer were 82.6%and 90.1%,respectively(p=0.002).Conclusion:FISH is significantly more sensitive than voided urine cytology for detecting bladder cancer in patients evaluated for gross hematuria at all cancer grades and stages.Higher sensitivity using FISH was obtained in high grade and muscle invasive tumors.展开更多
A system of on-line contamination detecting in hydraulic oil based on silting principle is accomplished, where, metal filter membrane as detector, solenoid as active force to propel piston to blotter and gain differen...A system of on-line contamination detecting in hydraulic oil based on silting principle is accomplished, where, metal filter membrane as detector, solenoid as active force to propel piston to blotter and gain differential pressure, step motor drives the membrane to filtrate and counter-flush, LabVIEW as detecting software platform, oil's contamination detecting indirectly by gauging differential pressure. Based on theory analysis, accomplished is relation between contamination level and differential pressure, realizing polynomial curve fitting, and calibration experiment. Field experiment is simulated in the condition of experimental laboratory, has credible precision and real-time performance, which can popularize to the field of production.展开更多
Laser-induced breakdown spectroscopy(LIBS) has attracted extensive attention as a new technique for in-situ marine application. In this work, the influence of deep-sea high pressure environment on LIBS signals was inv...Laser-induced breakdown spectroscopy(LIBS) has attracted extensive attention as a new technique for in-situ marine application. In this work, the influence of deep-sea high pressure environment on LIBS signals was investigated by using a compact LIBS-sea system developed by Ocean University of China for the in-situ chemical analysis of seawater. The results from the field measurements show that the liquid pressure has a significant effect on the LIBS signals. Higher peak intensity and larger line broadening were obtained as the pressure increases. By comparing the variations of the temperature and salinity with the LIBS signals, a weak correlation between them can be observed. Under high pressure conditions, the optimal laser energy was higher than that in air environment. When the laser energy exceeded 17 mJ, the effect of laser energy on the signal intensity weakened. The signal intensity decreases gradually at larger delays. The obtained results verified the feasibility of the LIBS technique for the deep-sea in-situ detection, and we hope this technology can contribute to surveying more deep-sea environments such as the hydrothermal vent regions.展开更多
Silver nanoclusters(AgNCs)are a new type of nanomaterials with similar properties to molecules and unique applications.The applications of AgNCs can be significantly expanded by combining them with different matrix ma...Silver nanoclusters(AgNCs)are a new type of nanomaterials with similar properties to molecules and unique applications.The applications of AgNCs can be significantly expanded by combining them with different matrix materials to obtain AgNC composites.Using irradiation techniques,we developed a simple two-step method for preparing silver nanocluster composites.First,polyacrylic acid(PAA)chains were grafted onto the surface of a PE film as templates(PE-g-PAA).Subsequently,silver ions were reduced in situ on the surface of the template material to obtain the AgNC composites(AgNCs@PE-g-PAA).The degree of AgNC loading on the composite film was easily controlled by adjusting the reaction conditions.The loaded AgNCs were anchored to the carboxyl groups of the PAA and wrapped in the graft chain.The particle size of the AgNCs was only 4.38±0.85 nm,with a very uniform particle size distribution.The AgNCs@PE-g-PAA exhibited fluorescence characteristics derived from the AgNCs.The fluorescence of the AgNCs@PE-g-PAA was easily quenched by Cr^(3+)ions.The composite can be used as a fluorescence test paper to realize visual detection of Cr^(3+).展开更多
A rapid and sensitive on-line preconcentration method for spectrophotometric determination of chromium (VI) in nature water is described. Preconcentration and determination are based on (i) the quantitative and fast a...A rapid and sensitive on-line preconcentration method for spectrophotometric determination of chromium (VI) in nature water is described. Preconcentration and determination are based on (i) the quantitative and fast adsorption of chromium (VI) on the high surface area nanometer-size TiO2 (anatase) powders, which prepared by a sol-gel method from hydrolysis of TiCI4 and (ii) the quantitative and reproducible elution of Cr (VI) by 2. 0 mol. L-1 HCI. A mini-column system for preconcentration is developed, Cr(VI)on the mini-column is eluted and merged with a stream water and DPCB (1, 5-diphenylcarbazide ) as the chromogenic reagent. The Proposed system permits throughputs of 6 sample h--l (0. 001 μg mL-1 Cr(VI) ) or 20 sample h-1 (0. 1 μg mL-1Cr (VI) . The preconcentration factor is 55. The detection limit is 0. 8 ng·mL-1 Cr(VI). The reproducibility is satisfactory with a relative standard deviation of less than 3. 35% (0. Of μg'mL-1Cr (VI), n = 5).展开更多
In this work, a binary-mixed-brushes-coated (BBC) capillary with switchable protein adsorption/desorption properties was developed and applied for on-line preconcentration of proteins. Firstly, amine-terminated poly(2...In this work, a binary-mixed-brushes-coated (BBC) capillary with switchable protein adsorption/desorption properties was developed and applied for on-line preconcentration of proteins. Firstly, amine-terminated poly(2-methyl-2-oxazoline)(PMOXA-NH2) and thiolterminated poly(acrylic acid)(PAA-SH) were synthesized by using cationic ring-opening polymerization (CROP) and reversible addition fragmentation chain transfer (RAFT) polymerization, respectively. Then, the BBC capillary based on poly(2-methyl-2-oxazoline)(PMOXA) and poly(acrylic acid)(PAA) was prepared by sequentially grafting of PMOXA-NH2 and PAA-SH onto fused-silica capillary inner surface through poly(dopamine)(PDA) as an anchor. The obtained PMOXA/PAA coating formed on the capillary or capillary's raw material was characterized in terms of the thickness, surface chemical composition by using scanning electron microscope (SEM) and X-ray photoelectron spectrum (XPS). The switchable protein adsorption/desorption performance of the BBC capillary was investigated by using fluorescence microscope under di erent solutions with certain pH and ionic strength(I). The results showed that bovine serum albumin (BSA) could be adsorbed on BBC capillary at pH=5.0 (I=10^-5 mol/L), and then the adsorbed BSA could be released at pH=9.0 (I=0.1 mol/L). This switchable protein adsorption/desorption property of coated capillary was then used to preconcentrate proteins on-line for increasing the detection sensitivity of BSA in capillary electrophoresis (CE). With this method, a sensitivity enhancement factor (SEF) more than 5000 for BSA detection was obtained.展开更多
A new simple, sensitive and precise green analytical procedure using an automated packed-reactor derivatization technique coupled with on-line solid-phase enrichment (SPEn) has been developed and evaluated to determ...A new simple, sensitive and precise green analytical procedure using an automated packed-reactor derivatization technique coupled with on-line solid-phase enrichment (SPEn) has been developed and evaluated to determine trace levels of methotrexate (MTX). The method was based on injection of MTX into a flowing stream of phosphate buffer (0.04 M, ptt 3.4), carried through the packed oxidant reactor of Cerium (IV) trihydroxyhydroperoxide for oxidative cleavage of the drug into highly fluorescent product, 2,4-diaminopteridine- 6-carboxylic acid, followed by SPEn on a head of short ODS column (10mm x 4.6 mm i.d., 5 I+tm particle size). The flow rate was 0.25 mL/min and packed reactor temperaturc was 40 ~C. The trapped product was back-flush eluted from the ODS column to the detector by column-switching with an environmentally friendly mobile phase consisting of ethanol and phosphate buffer (0.04 M, pH 3.4) in the ratio of 5:95 (v/v). The eluent was monitored at emission and excitation wavelengths of 460 and was linear over the concentration range of 1.25-50 360 nm, respectively. The calibration curve ng/mL with a detection limit of 0.08 ug/ml..The method was successfully applied to determine MTX in pharmaceutical formulations with mean percentage recovery ranging from 99.48 to 99.60.展开更多
This paper presents an automatic system for failure detection in hydro-power generators. The main idea of this system is to detect failure using current and voltage signals acquired without any type of internal interf...This paper presents an automatic system for failure detection in hydro-power generators. The main idea of this system is to detect failure using current and voltage signals acquired without any type of internal interference in the generator operation. The detected failures could be mechanical or electrical origins, such as: problems in bearings, unwanted vibrations, partial discharges, misalignment, unbalancing, among others. It is possible because the generator acts as a transducer for mechanical problems, and they appear in current and voltage signals. This automatic system based on electric signature analysis has been installed in Itapebi Power Plant generators since 2012. Some results are presented in this paper.展开更多
An in situ hybridization technique with 35S labelled proto-oncogene probes (c-myc & c-fes) was used to detect their expression in bone marrow cells of 22 cases of leukemia of various types and immature granulocyte...An in situ hybridization technique with 35S labelled proto-oncogene probes (c-myc & c-fes) was used to detect their expression in bone marrow cells of 22 cases of leukemia of various types and immature granulocytes and erythroblasts of 16 nomal myelograms as controls. Both c-myc and c-fes were detectable in leukemic cells as well as in immature granulocytes and erythroblasts of normal bone marrow, but the expression extent varied in different cases. The levels of c-myc expression in leukemic cells were higher than those in controls (P<0.001). There was no difference of c-fes expression in two groups of bone marrow cells (P>0.05). This technique provides us a new method in studying variations of proto-oncogene expression in leukemic cells.展开更多
Prompt gamma neutron activation analysis (PGNAA) is a non-destructive online measurement nuclear analysis method. With its unique advantages, it has been widely used in online analysis of industrial materials such as ...Prompt gamma neutron activation analysis (PGNAA) is a non-destructive online measurement nuclear analysis method. With its unique advantages, it has been widely used in online analysis of industrial materials such as coal, cement, and minerals in recent years. </span><span style="font-family:Verdana;">However, there are many kinds of literature on PGNAA in the field of industrial materials detection, and there are still a few concluding articles. To this end,</span><span style="font-family:Verdana;"> based on the principle of PGNAA online analysis, the status quo and development of the real-time online detection of industrial material components in the field are reviewed and discussed by consulting a large number of domestic and foreign PGNAA related literature and data, to facilitate the reference of relevant scientific researchers.展开更多
In situ surface-enhanced Raman scattering(SERS)is a widely used operando analytical technique,while facing numerous complex factors in applications under aqueous environment,such as low detection sensitivity,poor anti...In situ surface-enhanced Raman scattering(SERS)is a widely used operando analytical technique,while facing numerous complex factors in applications under aqueous environment,such as low detection sensitivity,poor anti-interference capability,etc.,resulting in unreliable detectability.To address these issues,herein a new hydrophobic SERS strategy has been attempted.By comprehensively designing and researching a SERS-active structure of superhydrophobic ZnO/Ag nanowires,we demonstrate that hydrophobicity can not only draw analytes from water onto substrate,but also adjust"hottest spot"from the bottom of the nanowires to the top.As a result,the structure can simultaneously concentrate the dispersed molecules in water and the enhanced electric field in structure into a same zone,while perfecting its own anti-interference ability.The underwater in situ analytical enhancement factor of this platform is as high as 1.67×10^(11),and the operando limited of detection for metronidazole(MNZ)reaches to 10^(-9)M.Most importantly,we also successfully generalized this structure to various real in situ detection scenarios,including on-site detection of MNZ in corrosive urine,real-time warning of wrong dose of MNZ during intravenous therapy,in situ monitoring of MNZ in flowing wastewater with particulate interference,etc.,demonstrating the great application potential of this hydrophobic platform.This work realizes a synergistic promotion for in situ SERS performance under aqueous environment,and also provides a novel view for improving other in situ analytical techniques.展开更多
A multifunctional Cu2O/Ag micro-nanocomposite, which has the characteristics of high cat- alytic activities under the visible light and high surface-enhanced Raman scattering (SERS) activity, was fabricated via a fa...A multifunctional Cu2O/Ag micro-nanocomposite, which has the characteristics of high cat- alytic activities under the visible light and high surface-enhanced Raman scattering (SERS) activity, was fabricated via a facile method and employed for the in situ SERS monitoring of the photocatalytic degradation reaction of crystal violet. Through the variation of the AgNO3 concentration, Ag content on the Cu2O template can be controllably tuned, which has great influence on the SERS effect. The results indicate that Ag nanopartieles form on the Cu2O nanoframes to obtain the Cu2O/Ag nanoeomposite, which can act as an excellent bifunetional platform for in situ monitoring of photocatalytic degradation of organic pollutions by SERS.展开更多
Low-molecular-weight(LMW)compounds are ubiquitous in living organisms and play essential roles in biological processes.The direct analysis of LMW compounds in biological tissues by matrix-assisted laser desorption/ion...Low-molecular-weight(LMW)compounds are ubiquitous in living organisms and play essential roles in biological processes.The direct analysis of LMW compounds in biological tissues by matrix-assisted laser desorption/ionization mass spectrometry imaging(MALDI-MSI)could provide a more comprehensive understanding of their essential functions.Here,we evaluated 4-nitrocatechol(4-NC)as a novel positive-ion matrix for enhancing in situ detection and imaging of LMW compounds from the rat liver,brain,and germinating Chinese-yew seed by MALDI-MS.Our results showed that the 4-NC possessed remarkable features,including strong ultraviolet absorption,uniform matrix crystal,excellent chemical stability,and fewer matrix-related background peaks.The use of 4-NC led to the successful detection of 232,218,and193 LMW compounds from the three abovementioned tissue sections,respectively.Also,the use of 4-NC improved the imaging quality of LMW compounds in tissue sections through MALDI-MSI and has the potential as a matrix for MALDI tissue imaging of LMW compounds.展开更多
Aluminum metallization using the sprayed coating for exhaust mild steel (MS) pipes of tractors is a standard practice for avoiding rusting. Patches of thin metal coats are prone to rusting and are thus considered as...Aluminum metallization using the sprayed coating for exhaust mild steel (MS) pipes of tractors is a standard practice for avoiding rusting. Patches of thin metal coats are prone to rusting and are thus considered as defects in the surface coating. This paper reports a novel configuration of the fiber optic sensor for on-line checking the aluminum metaUization uniformity and hence for defect detection. An optimally chosen high bright 440 nm BLUE LED (light-emitting diode) launches light into a transmitting fiber inclined at the angle of 60° to the surface under inspection placed adequately. The reflected light is transported by a receiving fiber to a blue enhanced photo detector. The metallization thickness on the coated surface results in visually observable variation in the gray shades. The coated pipe is spirally inspected by a combination of linear and rotary motions. The sensor output is the signal conditioned and monitored with RISHUBH DAS. Experimental results show the good repeatability in the defect detection and coating non-uniformity measurement.展开更多
基金supported by the National Natural Science Foundation of China(Nos.52125402 and 52174084)the Natural Science Foundation of Sichuan Province of China(No.2022NSFSC0005).
文摘The deep earth,deep sea,and deep space are the main parts of the national“three deep”strategy,which is in the forefront of the strategic deployment clearly defined in China’s 14th Five-Year Plan(2021-2025)and the Long-Range Objectives Through the Year 2035.It is important to reveal the evolutionary process and mechanism of deep tectonics to understand the earth’s past,present and future.The academic con-notation of Geology in Time has been given for the first time,which refers to the multi-field evolution response process of geological bodies at different time and spatial scales caused by geological processes inside and outside the Earth.Based on the deep in situ detection space and the unique geological envi-ronment of China Jinping Underground Laboratory,the scientific issue of the correlation mechanism and law between deep internal time-varying and shallow geological response is given attention.Innovative research and frontier exploration on deep underground in situ geo-information detection experiments for Geology in Time are designed to be carried out,which will have the potential to explore the driving force of Geology in Time,reveal essential laws of deep earth science,and explore innovative technologies in deep underground engineering.
文摘On-line chatter detection can avoid unstable cutting through monitoring the machining process.In order to identify chatter in a timely manner,an improved Support Vector Machine(SVM)is developed in this paper,based on extracted features.In the SVM model,the penalty factor(e)and the core parameter(g)have important influence on the classification,more than from Kernel Functions(KFs).Hence,first the classification results are conducted using different KFs.Then two methods are presented for exploring the best parameters.The chatter identification results show that the Genetic Algorithm(GA)approach is more suitable for deciding the parameters than the Grid Explore(GE)approach.
文摘The valuation relation of potential difference with discharging time in Electrical Discharge Machining (EDM) is analyzed theoretically and tested and verified by experiments designed in this paper and the relation between potential difference and spark location is induced and analyzed, and proceed by experiments under the condition of onedimension.
文摘A quite new type of chelating resin Carboxymethylated Polyethylenimine-Polymethylenepolyphenylene Isocyanate(CPPI)is used for the preconcentration of Zn from high salt water such as seawater. The preconcentration is controlled through the technique of Flow Injection Analysis(FIA).The concentrated sample solution is then directly transferred to an Inductively Coupled Plasma-Atomic Fluorescence Spectrometer(ICP-AFS)for determination.The detection limit of Zn by the technique is about 0.06 ppb.
文摘Microfluidic analytical system was developed based on annular flow of phase separation multiphase flow with a ternary water-hydrophilic/hydrophobic organic solvent solution. The analytical system was combined with on-line luminol chemiluminescence detection for catechin analysis. The water (10 mM phosphate buffer, pH 7.3)-acetonitrile-ethyl acetate mixed solution (3:8:4, volume ratio) containing 60 μM luminol and 2 mM hydrogen peroxide as a carrier was fed into the capillary tube (open-tubular fused-silica, 75 μm inner diameter, 110 cm effective length) at a flow rate of 1.0 μL·min-1. The carrier solution showed stable chemiluminescence as a baseline on the flow chart. Eight catechins were detected as negative peaks for their antioxidant potential with different detection times. The system was applied to analyze the amounts of catechin in commercially available green tea beverages.
基金This work was supported by the Natural Sciences Foundation of China (Grant No. NSFC. 40176036).
文摘Objective To develop an in situ PCR in combination with flow cytometry (ISPCR-FCM) for monitoring cholera toxin positive Vibrio cholerae. Methods In running this method, 4% paraformaldehyde was used to fix the Vibrio cholerae cells and 1 mg/mL lysozyme for 20 min to permeabilize the cells. Before the PCR thermal cycling, 2.5% glycerol was added into the PCR reaction mixture in order to protect the integrality of the cells. Results A length of 1037bp DNA sequence was amplified, which is specific for the cholera toxin gene (ctxAB gene). Cells subjected to ISPCR showed the presences of ctxAB gene both in epifluorescence microscopy and in flow cytometric analysis. The specificity and sensitivity of the method were investigated. The sensitivity was relatively low (10^5 cells/mL), while the specificity was high. Conclusion We have successfully developed a new technique for detection of toxigenic Vibrio cholerae strains. Further study is needed to enhance its sensitivities. ISPCR-FCM shows a great promise in monitoring specific bacteria and their physiological states in environmental samples.
基金This clinical research was funded by the Ministry of Health People’s Republic of China(No.WKJ2007-3-001).
文摘Objective:To evaluate the diagnostic value of fluorescence in situ hybridization(FISH)in bladder cancer.Methods:We enrolled healthy volunteers and patients who were clinically suspected to have bladder cancer and conducted FISH tests and cytology examinations from August 2007 to December 2008.Receiver operating characteristic(ROC)curve analysis was performed and the area under curve(AUC)values were calculated for both the FISH and urine cytology tests.Results:A cohort of 988 healthy volunteers was enrolled to establish a reference range for the normal population.A total of 4807 patients with hematuria were prospectively,randomly enrolled for the simultaneous analysis of urine cytology,FISH testing,and a final diagnosis as determined by the pathologic findings of a biopsy or a surgically-excised specimen.Overall,the sensitivity of FISH in detecting transitional-cell carcinoma was 82.7%,while that of cytology was 33.4%(p<0.001).The sensitivity values of FISH for non-muscle invasive and muscle invasive bladder transitional-cell carcinoma were 81.7%and 89.6%,respectively(p=0.004).The sensitivity values of FISH for low and high grade bladder cancer were 82.6%and 90.1%,respectively(p=0.002).Conclusion:FISH is significantly more sensitive than voided urine cytology for detecting bladder cancer in patients evaluated for gross hematuria at all cancer grades and stages.Higher sensitivity using FISH was obtained in high grade and muscle invasive tumors.
文摘A system of on-line contamination detecting in hydraulic oil based on silting principle is accomplished, where, metal filter membrane as detector, solenoid as active force to propel piston to blotter and gain differential pressure, step motor drives the membrane to filtrate and counter-flush, LabVIEW as detecting software platform, oil's contamination detecting indirectly by gauging differential pressure. Based on theory analysis, accomplished is relation between contamination level and differential pressure, realizing polynomial curve fitting, and calibration experiment. Field experiment is simulated in the condition of experimental laboratory, has credible precision and real-time performance, which can popularize to the field of production.
基金supported by National Key Research and Development Program of China (No. 2016YFC0302102)Fundamental Research Funds for the Central Universities (No. 201822003)
文摘Laser-induced breakdown spectroscopy(LIBS) has attracted extensive attention as a new technique for in-situ marine application. In this work, the influence of deep-sea high pressure environment on LIBS signals was investigated by using a compact LIBS-sea system developed by Ocean University of China for the in-situ chemical analysis of seawater. The results from the field measurements show that the liquid pressure has a significant effect on the LIBS signals. Higher peak intensity and larger line broadening were obtained as the pressure increases. By comparing the variations of the temperature and salinity with the LIBS signals, a weak correlation between them can be observed. Under high pressure conditions, the optimal laser energy was higher than that in air environment. When the laser energy exceeded 17 mJ, the effect of laser energy on the signal intensity weakened. The signal intensity decreases gradually at larger delays. The obtained results verified the feasibility of the LIBS technique for the deep-sea in-situ detection, and we hope this technology can contribute to surveying more deep-sea environments such as the hydrothermal vent regions.
基金supported by the Gansu Natural Science Foundation (Nos.20JR10RA778 and 20JR10RA777)。
文摘Silver nanoclusters(AgNCs)are a new type of nanomaterials with similar properties to molecules and unique applications.The applications of AgNCs can be significantly expanded by combining them with different matrix materials to obtain AgNC composites.Using irradiation techniques,we developed a simple two-step method for preparing silver nanocluster composites.First,polyacrylic acid(PAA)chains were grafted onto the surface of a PE film as templates(PE-g-PAA).Subsequently,silver ions were reduced in situ on the surface of the template material to obtain the AgNC composites(AgNCs@PE-g-PAA).The degree of AgNC loading on the composite film was easily controlled by adjusting the reaction conditions.The loaded AgNCs were anchored to the carboxyl groups of the PAA and wrapped in the graft chain.The particle size of the AgNCs was only 4.38±0.85 nm,with a very uniform particle size distribution.The AgNCs@PE-g-PAA exhibited fluorescence characteristics derived from the AgNCs.The fluorescence of the AgNCs@PE-g-PAA was easily quenched by Cr^(3+)ions.The composite can be used as a fluorescence test paper to realize visual detection of Cr^(3+).
文摘A rapid and sensitive on-line preconcentration method for spectrophotometric determination of chromium (VI) in nature water is described. Preconcentration and determination are based on (i) the quantitative and fast adsorption of chromium (VI) on the high surface area nanometer-size TiO2 (anatase) powders, which prepared by a sol-gel method from hydrolysis of TiCI4 and (ii) the quantitative and reproducible elution of Cr (VI) by 2. 0 mol. L-1 HCI. A mini-column system for preconcentration is developed, Cr(VI)on the mini-column is eluted and merged with a stream water and DPCB (1, 5-diphenylcarbazide ) as the chromogenic reagent. The Proposed system permits throughputs of 6 sample h--l (0. 001 μg mL-1 Cr(VI) ) or 20 sample h-1 (0. 1 μg mL-1Cr (VI) . The preconcentration factor is 55. The detection limit is 0. 8 ng·mL-1 Cr(VI). The reproducibility is satisfactory with a relative standard deviation of less than 3. 35% (0. Of μg'mL-1Cr (VI), n = 5).
基金supported by the National Natural Science Foundation of China (No.21674102)
文摘In this work, a binary-mixed-brushes-coated (BBC) capillary with switchable protein adsorption/desorption properties was developed and applied for on-line preconcentration of proteins. Firstly, amine-terminated poly(2-methyl-2-oxazoline)(PMOXA-NH2) and thiolterminated poly(acrylic acid)(PAA-SH) were synthesized by using cationic ring-opening polymerization (CROP) and reversible addition fragmentation chain transfer (RAFT) polymerization, respectively. Then, the BBC capillary based on poly(2-methyl-2-oxazoline)(PMOXA) and poly(acrylic acid)(PAA) was prepared by sequentially grafting of PMOXA-NH2 and PAA-SH onto fused-silica capillary inner surface through poly(dopamine)(PDA) as an anchor. The obtained PMOXA/PAA coating formed on the capillary or capillary's raw material was characterized in terms of the thickness, surface chemical composition by using scanning electron microscope (SEM) and X-ray photoelectron spectrum (XPS). The switchable protein adsorption/desorption performance of the BBC capillary was investigated by using fluorescence microscope under di erent solutions with certain pH and ionic strength(I). The results showed that bovine serum albumin (BSA) could be adsorbed on BBC capillary at pH=5.0 (I=10^-5 mol/L), and then the adsorbed BSA could be released at pH=9.0 (I=0.1 mol/L). This switchable protein adsorption/desorption property of coated capillary was then used to preconcentrate proteins on-line for increasing the detection sensitivity of BSA in capillary electrophoresis (CE). With this method, a sensitivity enhancement factor (SEF) more than 5000 for BSA detection was obtained.
文摘A new simple, sensitive and precise green analytical procedure using an automated packed-reactor derivatization technique coupled with on-line solid-phase enrichment (SPEn) has been developed and evaluated to determine trace levels of methotrexate (MTX). The method was based on injection of MTX into a flowing stream of phosphate buffer (0.04 M, ptt 3.4), carried through the packed oxidant reactor of Cerium (IV) trihydroxyhydroperoxide for oxidative cleavage of the drug into highly fluorescent product, 2,4-diaminopteridine- 6-carboxylic acid, followed by SPEn on a head of short ODS column (10mm x 4.6 mm i.d., 5 I+tm particle size). The flow rate was 0.25 mL/min and packed reactor temperaturc was 40 ~C. The trapped product was back-flush eluted from the ODS column to the detector by column-switching with an environmentally friendly mobile phase consisting of ethanol and phosphate buffer (0.04 M, pH 3.4) in the ratio of 5:95 (v/v). The eluent was monitored at emission and excitation wavelengths of 460 and was linear over the concentration range of 1.25-50 360 nm, respectively. The calibration curve ng/mL with a detection limit of 0.08 ug/ml..The method was successfully applied to determine MTX in pharmaceutical formulations with mean percentage recovery ranging from 99.48 to 99.60.
文摘This paper presents an automatic system for failure detection in hydro-power generators. The main idea of this system is to detect failure using current and voltage signals acquired without any type of internal interference in the generator operation. The detected failures could be mechanical or electrical origins, such as: problems in bearings, unwanted vibrations, partial discharges, misalignment, unbalancing, among others. It is possible because the generator acts as a transducer for mechanical problems, and they appear in current and voltage signals. This automatic system based on electric signature analysis has been installed in Itapebi Power Plant generators since 2012. Some results are presented in this paper.
文摘An in situ hybridization technique with 35S labelled proto-oncogene probes (c-myc & c-fes) was used to detect their expression in bone marrow cells of 22 cases of leukemia of various types and immature granulocytes and erythroblasts of 16 nomal myelograms as controls. Both c-myc and c-fes were detectable in leukemic cells as well as in immature granulocytes and erythroblasts of normal bone marrow, but the expression extent varied in different cases. The levels of c-myc expression in leukemic cells were higher than those in controls (P<0.001). There was no difference of c-fes expression in two groups of bone marrow cells (P>0.05). This technique provides us a new method in studying variations of proto-oncogene expression in leukemic cells.
文摘Prompt gamma neutron activation analysis (PGNAA) is a non-destructive online measurement nuclear analysis method. With its unique advantages, it has been widely used in online analysis of industrial materials such as coal, cement, and minerals in recent years. </span><span style="font-family:Verdana;">However, there are many kinds of literature on PGNAA in the field of industrial materials detection, and there are still a few concluding articles. To this end,</span><span style="font-family:Verdana;"> based on the principle of PGNAA online analysis, the status quo and development of the real-time online detection of industrial material components in the field are reviewed and discussed by consulting a large number of domestic and foreign PGNAA related literature and data, to facilitate the reference of relevant scientific researchers.
基金the National Natural Science Foundation of China(No.11974222 and 11904214)the Natural Science Foundation of Shandong Province(No.ZR2020KA004 and ZR2019YQ09)for financial support
文摘In situ surface-enhanced Raman scattering(SERS)is a widely used operando analytical technique,while facing numerous complex factors in applications under aqueous environment,such as low detection sensitivity,poor anti-interference capability,etc.,resulting in unreliable detectability.To address these issues,herein a new hydrophobic SERS strategy has been attempted.By comprehensively designing and researching a SERS-active structure of superhydrophobic ZnO/Ag nanowires,we demonstrate that hydrophobicity can not only draw analytes from water onto substrate,but also adjust"hottest spot"from the bottom of the nanowires to the top.As a result,the structure can simultaneously concentrate the dispersed molecules in water and the enhanced electric field in structure into a same zone,while perfecting its own anti-interference ability.The underwater in situ analytical enhancement factor of this platform is as high as 1.67×10^(11),and the operando limited of detection for metronidazole(MNZ)reaches to 10^(-9)M.Most importantly,we also successfully generalized this structure to various real in situ detection scenarios,including on-site detection of MNZ in corrosive urine,real-time warning of wrong dose of MNZ during intravenous therapy,in situ monitoring of MNZ in flowing wastewater with particulate interference,etc.,demonstrating the great application potential of this hydrophobic platform.This work realizes a synergistic promotion for in situ SERS performance under aqueous environment,and also provides a novel view for improving other in situ analytical techniques.
基金This work was supported by tile Key Projects of Natural Science Research of Universities in Anhui Province (No.KJ2015A183, No.KJ2015A201) and Talents Foundation of Hefei University (No.15RC05), Anhui Province Natural Science Foundation (No.1608085MD78), the Key Projects of Anhui Province University Outstanding Youth Talent Support Program (gxyqZD2016274), the National Natural Science Foundation of China (No.21305142, No.51403048).
文摘A multifunctional Cu2O/Ag micro-nanocomposite, which has the characteristics of high cat- alytic activities under the visible light and high surface-enhanced Raman scattering (SERS) activity, was fabricated via a facile method and employed for the in situ SERS monitoring of the photocatalytic degradation reaction of crystal violet. Through the variation of the AgNO3 concentration, Ag content on the Cu2O template can be controllably tuned, which has great influence on the SERS effect. The results indicate that Ag nanopartieles form on the Cu2O nanoframes to obtain the Cu2O/Ag nanoeomposite, which can act as an excellent bifunetional platform for in situ monitoring of photocatalytic degradation of organic pollutions by SERS.
基金supported by the National Natural Science Foundation of China(Nos.31770384 and 21605164)the Youth Academic Team Project of MUC(No.10301-02200301)+1 种基金the Huayi Technology Innovation Center for Research Resources(No.HTIC P01RR2017001A)the Key Laboratory Construction Funds of State Ethnic Affairs Commission of China(No.10301-02200303)。
文摘Low-molecular-weight(LMW)compounds are ubiquitous in living organisms and play essential roles in biological processes.The direct analysis of LMW compounds in biological tissues by matrix-assisted laser desorption/ionization mass spectrometry imaging(MALDI-MSI)could provide a more comprehensive understanding of their essential functions.Here,we evaluated 4-nitrocatechol(4-NC)as a novel positive-ion matrix for enhancing in situ detection and imaging of LMW compounds from the rat liver,brain,and germinating Chinese-yew seed by MALDI-MS.Our results showed that the 4-NC possessed remarkable features,including strong ultraviolet absorption,uniform matrix crystal,excellent chemical stability,and fewer matrix-related background peaks.The use of 4-NC led to the successful detection of 232,218,and193 LMW compounds from the three abovementioned tissue sections,respectively.Also,the use of 4-NC improved the imaging quality of LMW compounds in tissue sections through MALDI-MSI and has the potential as a matrix for MALDI tissue imaging of LMW compounds.
文摘Aluminum metallization using the sprayed coating for exhaust mild steel (MS) pipes of tractors is a standard practice for avoiding rusting. Patches of thin metal coats are prone to rusting and are thus considered as defects in the surface coating. This paper reports a novel configuration of the fiber optic sensor for on-line checking the aluminum metaUization uniformity and hence for defect detection. An optimally chosen high bright 440 nm BLUE LED (light-emitting diode) launches light into a transmitting fiber inclined at the angle of 60° to the surface under inspection placed adequately. The reflected light is transported by a receiving fiber to a blue enhanced photo detector. The metallization thickness on the coated surface results in visually observable variation in the gray shades. The coated pipe is spirally inspected by a combination of linear and rotary motions. The sensor output is the signal conditioned and monitored with RISHUBH DAS. Experimental results show the good repeatability in the defect detection and coating non-uniformity measurement.