The development of laser sampling for optical emission spectrometry is reviewed . Advantages and limitations of pulsed laser sampling are compared with those of continuous laser sampling . A novel method of laser samp...The development of laser sampling for optical emission spectrometry is reviewed . Advantages and limitations of pulsed laser sampling are compared with those of continuous laser sampling . A novel method of laser sampling of liquid samples for inductively coupled plasma -atomic emission spectrometry has been proposed , and its analytical performance investigated.Experimental results showed that,as a method of sample introduction , laser vaporization of liquid samples enjoyed certain advantages , e.g.,much higher sensitivity, much lower detection limit and reduced sample volume , over solution nebulization . A perspective of the application of laser sampling-inductively coupled plasma - actomic emission spectrometry for rock and mineral analysis is estimated as well.展开更多
考察了消解方式、消解酸体系、升温时间和目标温度对样品消解效果的影响,提出了微波消解-电感耦合等离子体原子发射光谱法(ICP-AES)同时测定钛及钛合金中Fe、Si、Mn、Mo、B、Al、Sn、Cr、V、Zr、Mg、Nb、Pd、Ni、Ta、W、Nd、Ru、Cu等19...考察了消解方式、消解酸体系、升温时间和目标温度对样品消解效果的影响,提出了微波消解-电感耦合等离子体原子发射光谱法(ICP-AES)同时测定钛及钛合金中Fe、Si、Mn、Mo、B、Al、Sn、Cr、V、Zr、Mg、Nb、Pd、Ni、Ta、W、Nd、Ru、Cu等19种元素含量的方法。取0.1000 g钛及钛合金样品置于聚四氟乙烯消解罐中,再加入8.0 mL 33%(体积分数)盐酸溶液、3.0 mL 25%(体积分数)氢氟酸溶液、1.0 mL 50%(体积分数)硝酸溶液和0.5 mL高氯酸,将其置于微波消解仪于最高消解温度120℃下保持10 min,冷却至室温,用水将消解液定容至50 mL,采用ICP-AES测定质量分数不大于1.0%的元素,将样品溶液稀释10倍,同法测定质量分数大于1.0%的元素。结果表明,19种元素的质量浓度在一定范围内与对应的响应强度呈线性关系,检出限(3s)为0.006~0.033 mg·L^(-1)。对4种钛合金标准样品和3种钛合金实际样品进行分析,并与标准方法GB/T 4698系列的测定结果进行对比,结果显示本方法的测定值与认定值基本一致。以两种钛合金标准样品和两种钛合金实际样品为研究对象进行精密度试验,每个样品平行测定5次,测定值的相对标准偏差均小于4.0%。展开更多
国际标准 ISO 7530-1:2015 中测定铬含量,使用一氧化二氮-乙炔火焰原子吸收光谱法,现已极少应用。本文报告了“电感耦合等离子体原子发射光谱法测定镍合金中的铬含量的分析方法研究”试验工作,通过样品溶解试验、称样量试验、基体干扰...国际标准 ISO 7530-1:2015 中测定铬含量,使用一氧化二氮-乙炔火焰原子吸收光谱法,现已极少应用。本文报告了“电感耦合等离子体原子发射光谱法测定镍合金中的铬含量的分析方法研究”试验工作,通过样品溶解试验、称样量试验、基体干扰试验、内标元素选择试验等优化和确立了分析方法条件,建立了电感耦合等离子体原子发射光谱发测定镍合金中铬含量的分析方法。精密度试验、标样测试、方法比对、加标回收等试验表明所建立的方法是准确可靠的,满足了镍合金中铬含量的测定要求,可推荐作为国家标准。展开更多
文摘The development of laser sampling for optical emission spectrometry is reviewed . Advantages and limitations of pulsed laser sampling are compared with those of continuous laser sampling . A novel method of laser sampling of liquid samples for inductively coupled plasma -atomic emission spectrometry has been proposed , and its analytical performance investigated.Experimental results showed that,as a method of sample introduction , laser vaporization of liquid samples enjoyed certain advantages , e.g.,much higher sensitivity, much lower detection limit and reduced sample volume , over solution nebulization . A perspective of the application of laser sampling-inductively coupled plasma - actomic emission spectrometry for rock and mineral analysis is estimated as well.
文摘考察了消解方式、消解酸体系、升温时间和目标温度对样品消解效果的影响,提出了微波消解-电感耦合等离子体原子发射光谱法(ICP-AES)同时测定钛及钛合金中Fe、Si、Mn、Mo、B、Al、Sn、Cr、V、Zr、Mg、Nb、Pd、Ni、Ta、W、Nd、Ru、Cu等19种元素含量的方法。取0.1000 g钛及钛合金样品置于聚四氟乙烯消解罐中,再加入8.0 mL 33%(体积分数)盐酸溶液、3.0 mL 25%(体积分数)氢氟酸溶液、1.0 mL 50%(体积分数)硝酸溶液和0.5 mL高氯酸,将其置于微波消解仪于最高消解温度120℃下保持10 min,冷却至室温,用水将消解液定容至50 mL,采用ICP-AES测定质量分数不大于1.0%的元素,将样品溶液稀释10倍,同法测定质量分数大于1.0%的元素。结果表明,19种元素的质量浓度在一定范围内与对应的响应强度呈线性关系,检出限(3s)为0.006~0.033 mg·L^(-1)。对4种钛合金标准样品和3种钛合金实际样品进行分析,并与标准方法GB/T 4698系列的测定结果进行对比,结果显示本方法的测定值与认定值基本一致。以两种钛合金标准样品和两种钛合金实际样品为研究对象进行精密度试验,每个样品平行测定5次,测定值的相对标准偏差均小于4.0%。
文摘国际标准 ISO 7530-1:2015 中测定铬含量,使用一氧化二氮-乙炔火焰原子吸收光谱法,现已极少应用。本文报告了“电感耦合等离子体原子发射光谱法测定镍合金中的铬含量的分析方法研究”试验工作,通过样品溶解试验、称样量试验、基体干扰试验、内标元素选择试验等优化和确立了分析方法条件,建立了电感耦合等离子体原子发射光谱发测定镍合金中铬含量的分析方法。精密度试验、标样测试、方法比对、加标回收等试验表明所建立的方法是准确可靠的,满足了镍合金中铬含量的测定要求,可推荐作为国家标准。