[Objective] The inductively coupled plasma mass spectrometry(ICP-MS)was constructed to determine the contents of lead,cadmium,mercury and arsenic in Archyranthes bidentata Blume.[Method]Under the optimum operation con...[Objective] The inductively coupled plasma mass spectrometry(ICP-MS)was constructed to determine the contents of lead,cadmium,mercury and arsenic in Archyranthes bidentata Blume.[Method]Under the optimum operation condition of ICP-MS,the samples were digested by microwave.The element 114In was taken as an internal standard element to compensate body effect and ICP-MS method was used to determine the contents of lead,cadmium,mercury and arsenic.[Result]For the determined elements,the correlation coefficient(r)of standard curve was over 0.9995 and recovery rate was from 96.7% to 106.4% while RSD was less than 11.2%.The result of determination showed that the heavy metal content in Archyranthes bidentata Blume.beyond standard was serious.[Conclusion]The constructed ICP-MS method with simple operation,rapid response,accuracy and high sensitivity in this experiment could be used for quality control of Chinese medicinal materials by detecting heavy metal contents in different Chinese medicinal materials from original places.展开更多
Inductively-coupled plasma mass spectrometry (ICP-MS) has made much progress since its birth in the late 1990s. This paper will give a rather systematic overview on the use of this technique in new devices and technol...Inductively-coupled plasma mass spectrometry (ICP-MS) has made much progress since its birth in the late 1990s. This paper will give a rather systematic overview on the use of this technique in new devices and technologies related to plasma source, sample-introducing device and detecting spectrometer etc. In this overview, an emphasis will be put on the evaluation of the ICP- MS technique in combination with a series of physical, chemical and biological techniques, such as laser ablation (LA), capillary electrophoresis (CE) and high performance liquid chromatograph (HPLC), along with their representative high accuracy and high sensitivity. Finally, comprehensive and fruitful applications of the ICP-MS and its combinative techniques in the detection of trace metallic elements and isotopes in complex biological and environmental samples will be revealed.展开更多
An inductively coupled plasma mass spectrometry(ICP-MS) method was developed for the determination of Na, Mg, Al,K, Ca, Ti, Cr, Co, Ni, Cu, Ga, As, Mo, Ag, Cd and Pb in MnZn ferrites. The sample was digested by HNO3+H...An inductively coupled plasma mass spectrometry(ICP-MS) method was developed for the determination of Na, Mg, Al,K, Ca, Ti, Cr, Co, Ni, Cu, Ga, As, Mo, Ag, Cd and Pb in MnZn ferrites. The sample was digested by HNO3+HCl with microwave digestion followed by dilution with ultrapure water, then the above 16 impurity elements in the solution were analyzed directly by ICP-MS. The impurity elements were introduced by the helium gas or hydrogen gas into the octopole reaction system(ORS) to eliminate the polyatomic interferences caused by the high salty matrixes. The matrix effect was minimized through matrix matching,and Be, Y and Rh were used as internal standard elements. The working parameters of the instrument were optimized. The results show that the method has good precision and high accuracy. The detection limits for the investigated elements are in the range of0.9-37.5 ng/L, the relative standard deviation of each element is within 1.1%-4.8%, and the recovery of each element is 90%-108%.展开更多
This study aimed to evaluate the uncertainty of simultaneous determination of lead(Pb),cadmium(Cd)and arsenic(As)in cosmetics by microwave digestion-inductively coupled plasma mass spectrometry(ICP-MS)with ^72Ge,^115I...This study aimed to evaluate the uncertainty of simultaneous determination of lead(Pb),cadmium(Cd)and arsenic(As)in cosmetics by microwave digestion-inductively coupled plasma mass spectrometry(ICP-MS)with ^72Ge,^115In and ^209Bi as internal standards.According to the method of Safety and Technical Standards for Cosmetics(2015),a mathematical model was established to evaluate the sources and components of uncertainty for the determination of lead,cadmium and arsenic in cosmetics.The results showed that the uncertainties in the determination of lead,cadmium,and arsenic elements in cosmetics were(10.1±0.6)mg/kg,k=2,(4.84±0.28)mg/kg,k=2,(2.04±0.18)mg/kg,k=2,respectively.The main factors that affect the uncertainty of determination results were standard substance,calibration curve,recovery and measurement repeatability.展开更多
本文利用微波消解对黄豆进行前处理,采用电感耦合等离子体质谱法(Inductively Coupled Plasma Mass Spectrometer,ICP-MS)对消解液中26种元素的含量进行测定,对方法的线性、精密度、准确度及质控样品进行验证。结果表明,各元素标准曲线...本文利用微波消解对黄豆进行前处理,采用电感耦合等离子体质谱法(Inductively Coupled Plasma Mass Spectrometer,ICP-MS)对消解液中26种元素的含量进行测定,对方法的线性、精密度、准确度及质控样品进行验证。结果表明,各元素标准曲线的相关系数均≥0.9990,线性关系良好,检出限为0.000583~0.453000 mg·kg^(-1),相对标准偏差≤5.513%,加标回收率为77%~113%,说明该方法能准确检测黄豆中无机元素,满足日常监测需求。展开更多
Inductively coupled plasma mass spectrometry (ICP-MS) was used to detect trace metal impurities in reagents such as H2O2, HNO3and H2SO4. The limit of detection to metal elements can be down to 2-20 ng/L in H2O2 and HN...Inductively coupled plasma mass spectrometry (ICP-MS) was used to detect trace metal impurities in reagents such as H2O2, HNO3and H2SO4. The limit of detection to metal elements can be down to 2-20 ng/L in H2O2 and HNO3 and 0.1-1.0 ng/L in H2SO4.展开更多
The application of inductively coupled plasma mass spectrometry (ICP-MS) for determination of boron in water and urine samples was described. The detect limit (3σ) was 0.057 μg/L. The precision of the method was les...The application of inductively coupled plasma mass spectrometry (ICP-MS) for determination of boron in water and urine samples was described. The detect limit (3σ) was 0.057 μg/L. The precision of the method was less than 2%. Multi-elements including Cr, Cu, Cd, Ba, Sr, Mn, Co, Tl, Li, Pb, Ca, Fe, K, Na, Mg, P, Si and Zn could be measured simultaneously. The method was successfully used in practice.展开更多
The determination of toxic metals in water using multiwalled carbon nanotubes (MWNTs) as a solid-phase extraction adsorbent prior to their determination by inductively coupled plasma mass spectrometry (ICP-MS) has...The determination of toxic metals in water using multiwalled carbon nanotubes (MWNTs) as a solid-phase extraction adsorbent prior to their determination by inductively coupled plasma mass spectrometry (ICP-MS) has been investigated. Standard addition method was applied for the calibration using aqueous solutions. Multiwalled carbon nanotubes (MWNTs) absorb these metals at pH 8.0, HNO3 of 1.0 mol-Ll is used for complete elusion of these metals from MWNTs. Previously investigated parameters have been applied for the determination of Pb, Cr, Ni and Mn in tap water samples. Fifteen tap water samples from different locations of Riyadh metropolitan area have been determined by ICP-MS after preconcentration with MWNTs.展开更多
The heavy metals determination in tap water samples using microcolumn packed with multiwalled carbon nanotubes (MWNTs) as a solid-phase extraction adsorbent before to their determination by inductively coupled plasm...The heavy metals determination in tap water samples using microcolumn packed with multiwalled carbon nanotubes (MWNTs) as a solid-phase extraction adsorbent before to their determination by inductively coupled plasma mass spectrometry (ICP-MS) has been studied. Standard addition method was applied for the calibration using aqueous solutions. The metals ions absorption were achieved by multiwalled carbon nanotubes (MWNTs) at pH 8.0, and then these retained metals on MWNTs column were eluted by 1.0 mol.L^-1 HNO3. The analytical parameters for the determination ofFe, Cu, and Zn in tap water samples which have been investigated previously were applied. Fifteen tap water samples were collected from different locations of Riyadh metropolitan area and then determined the concentration ofFe, Cu, and Zn by ICP-MS after preconcentration with MWNTs. The concentration range for Fe, Cu, and Zn measured (μg/L) in water samples are 23.37-137.91, 2.12-121.36, and 14.43-202.47 respectively. The level of Fe exceeded the limits set by WHO and SASO for drinking water.展开更多
Objective The aim of this survey was to investigate the level of contamination of the most consumed foods in China with 26 rare earth elements (REEs), and to provide the basic data for establishing and revising food...Objective The aim of this survey was to investigate the level of contamination of the most consumed foods in China with 26 rare earth elements (REEs), and to provide the basic data for establishing and revising food safety standards for REEs. Methods Sixteen REEs in foods were measured by inductively coupled plasma-mass spectrometry (ICP-MS) in the labs of the Centers for Disease Control and Prevention of four provinces and two municipalities, during 2009-2020. Results 2 231 samples were analyzed and 29 221 concentration data of 16 REEs were collected. The REEs levels in the investigated foods varied significantly. The concentrations of cerium (Ce), dysprosium (Dy), yttrium (Y), lanthanum (La), and neodymium (Nd) were relatively high, while the remaining eleven REEs were at low levels. The mean values of total rare earth element oxides (REOs) in cereals, fresh vegetables, fresh aquatic products, fresh meats and eggs varied from 0.052 mg/kg to 0.337 mg/kg. Conclusion 16 REEs in the major foods were at very low contamination levels in the investigated regions.展开更多
Six massive ores in the Jinchuan deposit were dated by Re-Os technique. The Os concentrations and isotopic ratios were determined by N-TIMS, while Re and Pt concentrations were determined by ICP-MS. The samples gave a...Six massive ores in the Jinchuan deposit were dated by Re-Os technique. The Os concentrations and isotopic ratios were determined by N-TIMS, while Re and Pt concentrations were determined by ICP-MS. The samples gave an isochron age of (852±25) Ma with an initial 187Os/188Os ratio of 0.255 ± 0.014. A 7-point Pt-Os isochrone gives an age of (870±38) Ma with an initial 186Os/188Os ratio of 0.119 84±0.000 27.展开更多
A method of analysis trace element chloride in cleaning products by Inductively Coupled Plasma-Mass Sepctrometry (ICPMS) was studied. It has good precision (RSD<5%). The LOD is 0.06 μg/L (n=7). The recovery is 93....A method of analysis trace element chloride in cleaning products by Inductively Coupled Plasma-Mass Sepctrometry (ICPMS) was studied. It has good precision (RSD<5%). The LOD is 0.06 μg/L (n=7). The recovery is 93.7%-110.0%.展开更多
The concentrations of seven essential trace elements in 149 freshwater fish from eight fish species (European eel, bream, common carp, European catfish, roach, perch, pike and pikeperch) from five different French f...The concentrations of seven essential trace elements in 149 freshwater fish from eight fish species (European eel, bream, common carp, European catfish, roach, perch, pike and pikeperch) from five different French fishing areas from contaminated and control sites were measured by inductively coupled plasma mass spectrometry after microwave digestion under pressure. Differences in the concentration of elements in the muscles of these species were examined and the mean levels were compared for each species with previous French and European studies. The condition factor and the differences between the control and contaminated sites and between predatory and non-predatory groups, with respect to the concentration of these elements, were also studied.展开更多
In this paper,the determination of six heavy metal ions (arsenic,lead,cadmium,chromium,mercury and nickel) in the Chinese Herb by inductively coupled plasma-mass spectrometry (ICP-MS) was studied.The samples were dige...In this paper,the determination of six heavy metal ions (arsenic,lead,cadmium,chromium,mercury and nickel) in the Chinese Herb by inductively coupled plasma-mass spectrometry (ICP-MS) was studied.The samples were digested by nitric acid and hydrogen peroxide in a microwave oven.The Sc,Y,In,Bi were added as internal standards to eliminate the matrix interferences.The results show that most of the relative standard deviations of these trace elements were below 3.5%,the standard recoveries of these elements were in the range of 91%-107%,and the detection limits were in the range of 0.001-0.006 μg·L-1. This method is accurate,rapid,convenience,and can be applied to the determination of arsenic,lead,cadmium,chromium,mercury and nickel in Chinese Herb with good results.展开更多
Inductively coupled plasma mass spectrometry(ICP-MS) was used to determine the concentration of Pb in atmospheric particulate samples,and the enrichment factor was calculated.The causes of the results were also discus...Inductively coupled plasma mass spectrometry(ICP-MS) was used to determine the concentration of Pb in atmospheric particulate samples,and the enrichment factor was calculated.The causes of the results were also discussed.展开更多
AIM: To evaluate the bioequivalence of ranitidine and bismuth derived from two compound preparations. METHODS: The bioavailability was measured in 20 healthy male Chinese volunteers following a single oral dose (eq...AIM: To evaluate the bioequivalence of ranitidine and bismuth derived from two compound preparations. METHODS: The bioavailability was measured in 20 healthy male Chinese volunteers following a single oral dose (equivalent to 200 mg of ranitidine and 220 mg of bismuth) of the test or reference products in the fasting state. Then blood samples were collected for 24 h. Plasma concentrations of ranitidine and bismuth were analyzed by high-performance liquid chromatography and inductively coupled plasma-mass spectrometry (ICPMS), respectively. The non-compartmental method was used for pharmacokinetic analysis. Log-transformed Cmax, AUC(0-t) and AUC(0-∞) were tested for bioequivalence using ANOVA and Schuirmann two-one sided t-test. Tmax was analyzed by Wilcoxon's test. RESULTS: Various pharmacokinetic parameters of ranitidine derived from the two compound preparations, including Cmax, AUC(0-t), AUC(0-∞), Tmax and T1/2, were nearly consistent with previous observations. These parameters derived from test and reference drug were as follows: Cmax(0.67 ± 0.21 vs 0.68 ± 0.22 mg/L), AUC(0-t)(3.1 ± 0.6 vs 3.0 ± 0.7 mg/L per hour), AUC(0-∞)(3.3 ± 0.6 vs 3.2 ± 0.8 mg/L per hour), Tmax (2.3 ± 0.9 VS 2.1 ± 0.9 h) and T1/2 (2.8 ± 0.3 vs 3.1 ± 0.4 h). In addition, double-peak absorption profiles of ranitidine were found in some Chinese volunteers. For bismuth, those parameters derived from test and reference drug were as follows: Cmax (11.80 ± 7.36 vs 11.40 ± 6.55 μg/L), AUC(0-t) (46.65 ± 16.97 vs 47.03 ± 21.49 μg/L per hour), Tmax (0.50 ± 0.20 vs 0.50 ± 0.20 h) and T1/2 (10.2 ± 2.3 vs 13.0 ± 6.9 h). Ninety percent of confidence intervals for the test/reference ratio of Cmax, AUC(0-t) and AUC(0-∞) derived from both ranitidine and bismuth were found within the bioequivalence acceptable range of 80%-125%. No significant difference was found in Tmax derived from both ranitidine and bismuth. CONCLUSION: The two compound preparations are bioequivalent and may be prescribed interchangeably.展开更多
The aim of this study was to discriminate organic from conventional orange juice based on chemical elements and data mining applications.A comprehensive sampling of organic and conventional oranges was carried out in ...The aim of this study was to discriminate organic from conventional orange juice based on chemical elements and data mining applications.A comprehensive sampling of organic and conventional oranges was carried out in Borborema,state of Sao Paulo,Brazil.The fruits of the variety Valencia(Citrus sinensis(L.)Osbeck)budded on Rangpur lime(Citrus limonia Osbeck)were analyzed.Eleven chemical elements were determined in 57 orange samples grown in organic and conventional systems.In order to classify these samples,data mining techniques(Support Vector Machine(SVM)and Multilayer Perceptron(MLP))were combined with feature selection(F-score and chi-squared).SVM with chi-squared had a better performance compared with the other techniques because it reached 93.00% accuracy using only seven chemical components(Cu,Cs,Zn,Al,Mn,Rb and Sr),and correctly classified 96.73% of the samples grown in an organic system.展开更多
基金Supported by the National Science Foundation for Post-doctoral Scientists of China(20070410616)Excellent Youth Foundation of He'nan Scientific Committee(074100510018)~~
文摘[Objective] The inductively coupled plasma mass spectrometry(ICP-MS)was constructed to determine the contents of lead,cadmium,mercury and arsenic in Archyranthes bidentata Blume.[Method]Under the optimum operation condition of ICP-MS,the samples were digested by microwave.The element 114In was taken as an internal standard element to compensate body effect and ICP-MS method was used to determine the contents of lead,cadmium,mercury and arsenic.[Result]For the determined elements,the correlation coefficient(r)of standard curve was over 0.9995 and recovery rate was from 96.7% to 106.4% while RSD was less than 11.2%.The result of determination showed that the heavy metal content in Archyranthes bidentata Blume.beyond standard was serious.[Conclusion]The constructed ICP-MS method with simple operation,rapid response,accuracy and high sensitivity in this experiment could be used for quality control of Chinese medicinal materials by detecting heavy metal contents in different Chinese medicinal materials from original places.
文摘Inductively-coupled plasma mass spectrometry (ICP-MS) has made much progress since its birth in the late 1990s. This paper will give a rather systematic overview on the use of this technique in new devices and technologies related to plasma source, sample-introducing device and detecting spectrometer etc. In this overview, an emphasis will be put on the evaluation of the ICP- MS technique in combination with a series of physical, chemical and biological techniques, such as laser ablation (LA), capillary electrophoresis (CE) and high performance liquid chromatograph (HPLC), along with their representative high accuracy and high sensitivity. Finally, comprehensive and fruitful applications of the ICP-MS and its combinative techniques in the detection of trace metallic elements and isotopes in complex biological and environmental samples will be revealed.
基金Project(21271187)supported by the National Natural Science Foundation of ChinaProject(cstc2013jcyj A10088)supported by the Chongqing Natural Science Foundation,China+1 种基金Projects(2013FJ3093,2013SK3268)supported by the Science and Technology Project of Hunan Province,ChinaProject(KJZH14217)supported by Achievement Transfer Education in Chongqing,China
文摘An inductively coupled plasma mass spectrometry(ICP-MS) method was developed for the determination of Na, Mg, Al,K, Ca, Ti, Cr, Co, Ni, Cu, Ga, As, Mo, Ag, Cd and Pb in MnZn ferrites. The sample was digested by HNO3+HCl with microwave digestion followed by dilution with ultrapure water, then the above 16 impurity elements in the solution were analyzed directly by ICP-MS. The impurity elements were introduced by the helium gas or hydrogen gas into the octopole reaction system(ORS) to eliminate the polyatomic interferences caused by the high salty matrixes. The matrix effect was minimized through matrix matching,and Be, Y and Rh were used as internal standard elements. The working parameters of the instrument were optimized. The results show that the method has good precision and high accuracy. The detection limits for the investigated elements are in the range of0.9-37.5 ng/L, the relative standard deviation of each element is within 1.1%-4.8%, and the recovery of each element is 90%-108%.
文摘This study aimed to evaluate the uncertainty of simultaneous determination of lead(Pb),cadmium(Cd)and arsenic(As)in cosmetics by microwave digestion-inductively coupled plasma mass spectrometry(ICP-MS)with ^72Ge,^115In and ^209Bi as internal standards.According to the method of Safety and Technical Standards for Cosmetics(2015),a mathematical model was established to evaluate the sources and components of uncertainty for the determination of lead,cadmium and arsenic in cosmetics.The results showed that the uncertainties in the determination of lead,cadmium,and arsenic elements in cosmetics were(10.1±0.6)mg/kg,k=2,(4.84±0.28)mg/kg,k=2,(2.04±0.18)mg/kg,k=2,respectively.The main factors that affect the uncertainty of determination results were standard substance,calibration curve,recovery and measurement repeatability.
文摘Inductively coupled plasma mass spectrometry (ICP-MS) was used to detect trace metal impurities in reagents such as H2O2, HNO3and H2SO4. The limit of detection to metal elements can be down to 2-20 ng/L in H2O2 and HNO3 and 0.1-1.0 ng/L in H2SO4.
文摘The application of inductively coupled plasma mass spectrometry (ICP-MS) for determination of boron in water and urine samples was described. The detect limit (3σ) was 0.057 μg/L. The precision of the method was less than 2%. Multi-elements including Cr, Cu, Cd, Ba, Sr, Mn, Co, Tl, Li, Pb, Ca, Fe, K, Na, Mg, P, Si and Zn could be measured simultaneously. The method was successfully used in practice.
文摘The determination of toxic metals in water using multiwalled carbon nanotubes (MWNTs) as a solid-phase extraction adsorbent prior to their determination by inductively coupled plasma mass spectrometry (ICP-MS) has been investigated. Standard addition method was applied for the calibration using aqueous solutions. Multiwalled carbon nanotubes (MWNTs) absorb these metals at pH 8.0, HNO3 of 1.0 mol-Ll is used for complete elusion of these metals from MWNTs. Previously investigated parameters have been applied for the determination of Pb, Cr, Ni and Mn in tap water samples. Fifteen tap water samples from different locations of Riyadh metropolitan area have been determined by ICP-MS after preconcentration with MWNTs.
文摘The heavy metals determination in tap water samples using microcolumn packed with multiwalled carbon nanotubes (MWNTs) as a solid-phase extraction adsorbent before to their determination by inductively coupled plasma mass spectrometry (ICP-MS) has been studied. Standard addition method was applied for the calibration using aqueous solutions. The metals ions absorption were achieved by multiwalled carbon nanotubes (MWNTs) at pH 8.0, and then these retained metals on MWNTs column were eluted by 1.0 mol.L^-1 HNO3. The analytical parameters for the determination ofFe, Cu, and Zn in tap water samples which have been investigated previously were applied. Fifteen tap water samples were collected from different locations of Riyadh metropolitan area and then determined the concentration ofFe, Cu, and Zn by ICP-MS after preconcentration with MWNTs. The concentration range for Fe, Cu, and Zn measured (μg/L) in water samples are 23.37-137.91, 2.12-121.36, and 14.43-202.47 respectively. The level of Fe exceeded the limits set by WHO and SASO for drinking water.
文摘Objective The aim of this survey was to investigate the level of contamination of the most consumed foods in China with 26 rare earth elements (REEs), and to provide the basic data for establishing and revising food safety standards for REEs. Methods Sixteen REEs in foods were measured by inductively coupled plasma-mass spectrometry (ICP-MS) in the labs of the Centers for Disease Control and Prevention of four provinces and two municipalities, during 2009-2020. Results 2 231 samples were analyzed and 29 221 concentration data of 16 REEs were collected. The REEs levels in the investigated foods varied significantly. The concentrations of cerium (Ce), dysprosium (Dy), yttrium (Y), lanthanum (La), and neodymium (Nd) were relatively high, while the remaining eleven REEs were at low levels. The mean values of total rare earth element oxides (REOs) in cereals, fresh vegetables, fresh aquatic products, fresh meats and eggs varied from 0.052 mg/kg to 0.337 mg/kg. Conclusion 16 REEs in the major foods were at very low contamination levels in the investigated regions.
文摘Six massive ores in the Jinchuan deposit were dated by Re-Os technique. The Os concentrations and isotopic ratios were determined by N-TIMS, while Re and Pt concentrations were determined by ICP-MS. The samples gave an isochron age of (852±25) Ma with an initial 187Os/188Os ratio of 0.255 ± 0.014. A 7-point Pt-Os isochrone gives an age of (870±38) Ma with an initial 186Os/188Os ratio of 0.119 84±0.000 27.
文摘A method of analysis trace element chloride in cleaning products by Inductively Coupled Plasma-Mass Sepctrometry (ICPMS) was studied. It has good precision (RSD<5%). The LOD is 0.06 μg/L (n=7). The recovery is 93.7%-110.0%.
文摘The concentrations of seven essential trace elements in 149 freshwater fish from eight fish species (European eel, bream, common carp, European catfish, roach, perch, pike and pikeperch) from five different French fishing areas from contaminated and control sites were measured by inductively coupled plasma mass spectrometry after microwave digestion under pressure. Differences in the concentration of elements in the muscles of these species were examined and the mean levels were compared for each species with previous French and European studies. The condition factor and the differences between the control and contaminated sites and between predatory and non-predatory groups, with respect to the concentration of these elements, were also studied.
文摘In this paper,the determination of six heavy metal ions (arsenic,lead,cadmium,chromium,mercury and nickel) in the Chinese Herb by inductively coupled plasma-mass spectrometry (ICP-MS) was studied.The samples were digested by nitric acid and hydrogen peroxide in a microwave oven.The Sc,Y,In,Bi were added as internal standards to eliminate the matrix interferences.The results show that most of the relative standard deviations of these trace elements were below 3.5%,the standard recoveries of these elements were in the range of 91%-107%,and the detection limits were in the range of 0.001-0.006 μg·L-1. This method is accurate,rapid,convenience,and can be applied to the determination of arsenic,lead,cadmium,chromium,mercury and nickel in Chinese Herb with good results.
文摘Inductively coupled plasma mass spectrometry(ICP-MS) was used to determine the concentration of Pb in atmospheric particulate samples,and the enrichment factor was calculated.The causes of the results were also discussed.
文摘AIM: To evaluate the bioequivalence of ranitidine and bismuth derived from two compound preparations. METHODS: The bioavailability was measured in 20 healthy male Chinese volunteers following a single oral dose (equivalent to 200 mg of ranitidine and 220 mg of bismuth) of the test or reference products in the fasting state. Then blood samples were collected for 24 h. Plasma concentrations of ranitidine and bismuth were analyzed by high-performance liquid chromatography and inductively coupled plasma-mass spectrometry (ICPMS), respectively. The non-compartmental method was used for pharmacokinetic analysis. Log-transformed Cmax, AUC(0-t) and AUC(0-∞) were tested for bioequivalence using ANOVA and Schuirmann two-one sided t-test. Tmax was analyzed by Wilcoxon's test. RESULTS: Various pharmacokinetic parameters of ranitidine derived from the two compound preparations, including Cmax, AUC(0-t), AUC(0-∞), Tmax and T1/2, were nearly consistent with previous observations. These parameters derived from test and reference drug were as follows: Cmax(0.67 ± 0.21 vs 0.68 ± 0.22 mg/L), AUC(0-t)(3.1 ± 0.6 vs 3.0 ± 0.7 mg/L per hour), AUC(0-∞)(3.3 ± 0.6 vs 3.2 ± 0.8 mg/L per hour), Tmax (2.3 ± 0.9 VS 2.1 ± 0.9 h) and T1/2 (2.8 ± 0.3 vs 3.1 ± 0.4 h). In addition, double-peak absorption profiles of ranitidine were found in some Chinese volunteers. For bismuth, those parameters derived from test and reference drug were as follows: Cmax (11.80 ± 7.36 vs 11.40 ± 6.55 μg/L), AUC(0-t) (46.65 ± 16.97 vs 47.03 ± 21.49 μg/L per hour), Tmax (0.50 ± 0.20 vs 0.50 ± 0.20 h) and T1/2 (10.2 ± 2.3 vs 13.0 ± 6.9 h). Ninety percent of confidence intervals for the test/reference ratio of Cmax, AUC(0-t) and AUC(0-∞) derived from both ranitidine and bismuth were found within the bioequivalence acceptable range of 80%-125%. No significant difference was found in Tmax derived from both ranitidine and bismuth. CONCLUSION: The two compound preparations are bioequivalent and may be prescribed interchangeably.
文摘The aim of this study was to discriminate organic from conventional orange juice based on chemical elements and data mining applications.A comprehensive sampling of organic and conventional oranges was carried out in Borborema,state of Sao Paulo,Brazil.The fruits of the variety Valencia(Citrus sinensis(L.)Osbeck)budded on Rangpur lime(Citrus limonia Osbeck)were analyzed.Eleven chemical elements were determined in 57 orange samples grown in organic and conventional systems.In order to classify these samples,data mining techniques(Support Vector Machine(SVM)and Multilayer Perceptron(MLP))were combined with feature selection(F-score and chi-squared).SVM with chi-squared had a better performance compared with the other techniques because it reached 93.00% accuracy using only seven chemical components(Cu,Cs,Zn,Al,Mn,Rb and Sr),and correctly classified 96.73% of the samples grown in an organic system.