Lower extremity peripherally inserted central catheter placement ectopic to the ascending lumbar vein:A case report
1
作者 Xiao-Ju Zhu Ling Zhao +2 位作者 Na Peng Jia-Min Luo Shui-Xia Liu 《World Journal of Clinical Cases》 SCIE 2024年第8期1430-1436,共7页
BACKGROUND Peripherally inserted central catheters(PICCs)are an essential infusion route for oncology patients receiving intravenous treatments,but lower extremity veni-puncture is the preferred technique for patients... BACKGROUND Peripherally inserted central catheters(PICCs)are an essential infusion route for oncology patients receiving intravenous treatments,but lower extremity veni-puncture is the preferred technique for patients with superior vena cava syndrome(SVCS).We report the case of a patient with a lower extremity PICC ectopic to the ascending lumbar vein,to indicate and verify PICC catheterisation in the lower extremity is safe and feasible.And hope to provide different per-spectives for clinical PICC venipuncture to get the attention of peers.CASE SUMMARY On 24 August 2022,a 58-year-old male was admitted to our department due to an intermittent cough persisting for over a month,which worsened 10 d prior.Imaging and laboratory investigations suggested the patient with pulmonary malignancy and SVCS.Chemotherapy was not an absolute contraindication in this patient.Lower extremity venipuncture is the preferred technique because administering upper extremity venous transfusion to patients with SVCS can exacerbate oedema in the head,neck,and upper extremities.The patient and his family were informed about the procedure,and informed consent was obtained.After successful puncture and prompt treatment,the patient was discharged,experiencing some relief from symptoms.CONCLUSION Inferior vena cava catheterisation is rare and important for cancer patients with SVCS,particularly in complex situations involving ectopic placement. 展开更多
关键词 Superior vena cava syndrome Peripherally inserted central catheter Ascending lumbar vein COMPLICATIONS Case report
下载PDF
Esophageal inserted subclavian catheter:a rare complication
2
作者 DilberÜçöz Kocaşaban SertaçGüler 《World Journal of Emergency Medicine》 SCIE CAS CSCD 2024年第3期243-245,共3页
Central venous catheterization(CVC) is an invasive procedure for administering fluids,nutrients,and drugs;monitoring central venous pressure;performing pulmonary artery catheterization;and placing transvenous pacemake... Central venous catheterization(CVC) is an invasive procedure for administering fluids,nutrients,and drugs;monitoring central venous pressure;performing pulmonary artery catheterization;and placing transvenous pacemakers in intensive care units and all specialties,from anesthesia to emergency medicine,for the treatment of trauma and hemodynamically unstable pediatric and adult patients.[1,2]Complications have been observed in more than 15% of patients who underwent CVC.Mechanical,infectious,and thrombotic complications have been reported in 5%–19%,5%–26%,and 2%–26% of patients,respectively.[3] Malposition,on the other hand,is common in subclavian catheter insertion and is usually associated with an initially misplaced guidewire.[4] 展开更多
关键词 UNSTABLE INSERTION initially
下载PDF
In-situ cation-inserted MnO_(2) with selective accelerated intercalation of individual H^(+) or Zn^(2+) ions in aqueous zinc ion batteries
3
作者 Lijin Yan Baibai Liu +6 位作者 Jiangyu Hao Yuying Han Chong Zhu Fuliang Liu Xuefeng Zou Yang Zhou Bin Xiang 《Journal of Energy Chemistry》 SCIE EI CAS CSCD 2023年第7期88-102,I0003,共16页
The recognized energy storage mechanism of neutral aqueous zinc-manganese batteries is the co-insertion/extrusion of H^(+) and Zn^(2+) ions.However,modulating the kinetics of a single H^(+) or Zn^(2+) ion is scarce,wh... The recognized energy storage mechanism of neutral aqueous zinc-manganese batteries is the co-insertion/extrusion of H^(+) and Zn^(2+) ions.However,modulating the kinetics of a single H^(+) or Zn^(2+) ion is scarce,which can provide meaningful insights into the energy storage mechanism of Zn ion batteries.Herein,a distinctive doubly electric field in-situ induced cationic anchoring of two-dimensional layered MnO_(2) is successfully constructed to modulate the insertion/extrusion of a single H^(+) or Zn^(2+) ion.As a result,regulating the intercalation of different metal ions can precisely achieve the accelerated induction for the individual H^(+) or Zn^(2+) ions intercalation/deintercalation.Moreover,the introduction of metal ions stabilizes the lattice distortion and alleviates the irreparable structural collapse,leading to an increase in the H^(+)/Zn^(2+) storage sites,efficiently diminishing the stagnation of the ordered structure and creating the more open channels,which is conducive to facilitating the diffusion of ions.This work delivers some innovative insights into pre-embedding strategies,and also serves as a precious reference for the cathode development of advanced aqueous batteries. 展开更多
关键词 In-situ inductions Manganese dioxide Insertion mechanisms Zinc-ion batteries
下载PDF
Prediction of Dynamic Cutting Force and Regenerative Chatter Stability in Inserted Cutters Milling 被引量:9
4
作者 LI Zhongqun LIU Qiang +1 位作者 YUAN Songmei HUANG Kaisheng 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2013年第3期555-563,共9页
Currently, the modeling of cutting process mainly focuses on two aspects: one is the setup of the universal cutting force model that can be adapted to a broader cutting condition; the other is the setup of the exact c... Currently, the modeling of cutting process mainly focuses on two aspects: one is the setup of the universal cutting force model that can be adapted to a broader cutting condition; the other is the setup of the exact cutting force model that can accurately reflect a true cutting process. However, there is little research on the prediction of chatter stablity in milling. Based on the generalized mathematical model of inserted cutters introduced by ENGIN, an improved geometrical, mechanical and dynamic model for the vast variety of inserted cutters widely used in engineering applications is presented, in which the average directional cutting force coefficients are obtained by means of a numerical approach, thus leading to an analytical determination of stability lobes diagram (SLD) on the axial depth of cut. A new kind of SLD on the radial depth of cut is also created to satisfy the special requirement of inserted cutter milling. The corresponding algorithms used for predicting cutting forces, vibrations, dimensional surface finish and stability lobes in inserted cutter milling under different cutting conditions are put forward. Thereafter, a dynamic simulation module of inserted cutter milling is implemented by using hybrid program of Matlab with Visual Basic. Verification tests are conducted on a vertical machine center for Aluminum alloy LC4 by using two different types of inserted cutters, and the effectiveness of the model and the algorithm is verified by the good agreement of simulation result with that of cutting tests under different cutting conditions. The proposed model can predict the cutting process accurately under a variety of cutting conditions, and a high efficient and chatter-free milling operation can be achieved by a cutting condition optimization in industry applications. 展开更多
关键词 inserted cutter cutting force prediction chatter stability dynamic simulation
下载PDF
Focus on peripherally inserted central catheters in critically ill patients 被引量:52
5
作者 Paolo Cotogni Mauro Pittiruti 《World Journal of Critical Care Medicine》 2014年第4期80-94,共15页
Venous access devices are of pivotal importance for an increasing number of critically ill patients in a variety of disease states and in a variety of clinical settings(emergency, intensive care, surgery) and for diff... Venous access devices are of pivotal importance for an increasing number of critically ill patients in a variety of disease states and in a variety of clinical settings(emergency, intensive care, surgery) and for different purposes(fluids or drugs infusions, parenteral nutrition, antibiotic therapy, hemodynamic monitoring, procedures of dialysis/apheresis). However, healthcare professionals are commonly worried about the possible consequences that may result using a central venous access device(CVAD)(mainly, bloodstream infections and thrombosis), both peripherally inserted central catheters(PICCs) and centrally inserted central catheters(CICCs). This review aims to discuss indications, insertion techniques, and care of PICCs in critically ill patients. PICCs have many advantages over standard CICCs. First of all, their insertion is easy and safe-due to their placement into peripheral veins of the armand the advantage of a central location of catheter tip suitable for all osmolarity and p H solutions. Using the ultrasound-guidance for the PICC insertion, the risk of hemothorax and pneumothorax can be avoided, as wellas the possibility of primary malposition is very low. PICC placement is also appropriate to avoid post-procedural hemorrhage in patients with an abnormal coagulative state who need a CVAD. Some limits previously ascribed to PICCs(i.e., low flow rates, difficult central venous pressure monitoring, lack of safety for radio-diagnostic procedures, single-lumen) have delayed their start up in the intensive care units as common practice. Though, the recent development of power-injectable PICCs overcomes these technical limitations and PICCs have started to spread in critical care settings. Two important take-home messages may be drawn from this review. First, the incidence of complications varies depending on venous accesses and healthcare professionals should be aware of the different clinical performance as well as of the different risks associated with each type of CVAD(CICCs or PICCs). Second, an inappropriate CVAD choice and, particularly, an inadequate insertion technique are relevant-and often not recognized-potential risk factors for complications in critically ill patients. We strongly believe that all healthcare professionals involved in the choice, insertion or management of CVADs in critically ill patients should know all potential risk factors of complications. This knowledge may minimize complications and guarantee longevity to the CVAD optimizing the risk/benefit ratio of CVAD insertion and use. Proper management of CVADs in critical care saves lines and lives. Much evidence from the medical literature and from the clinical practice supports our belief that, compared to CICCs, the so-called power-injectable peripherally inserted central catheters are a good alternative choice in critical care. 展开更多
关键词 CENTRAL VENOUS CATHETERS VENOUS access devices Ultrasound guidance Guidelines Peripherally inserted CENTRAL CATHETERS Blood stream INFECTIONS Intensive CARE unit patients Critical CARE medicine PEDIATRICS
下载PDF
Delayed cardiac tamponade diagnosed by point-of-care ultrasound in a neonate after peripherally inserted central catheter placement: A case report 被引量:3
6
作者 Yu Cui Kai Liu +1 位作者 Liming Luan Peng Liang 《World Journal of Clinical Cases》 SCIE 2021年第3期602-606,共5页
BACKGROUND Peripherally inserted central catheters(PICCs)have been increasingly applied worldwide owing to many advantages.Even with these advantages,the related complications should not be ignored,especially in neona... BACKGROUND Peripherally inserted central catheters(PICCs)have been increasingly applied worldwide owing to many advantages.Even with these advantages,the related complications should not be ignored,especially in neonates.The available evidence about PICC-related thrombosis was manifold,but the cardiac tamponade,an emergency and life-threatening complication,has been rarely reported.Early recognized cardiac tamponade by ultrasound may reduce mortality.CASE SUMMARY A neonate weighting 2.8 kg was born at 40 wk of gestation.He was admitted to the Surgery Intensive Care Unit due to suspected congenital megacolon.A PICC line was inserted via the left antecubital fossa for the administration of total parenteral nutrition.Three days later,the patient was still on total parenteral nutrition.Cardiac tamponade caused by PICC was found on ultrasound.The patient recovered spontaneously after an emergency pericardiocentesis.CONCLUSION Proficiency in the use of point-of-care ultrasound may save the life of patients,since it enables clinicians to treat patients faster,more accurately,and in a noninvasive way at the point of care. 展开更多
关键词 Peripherally inserted central catheters Point-of-care ultrasound NEONATES Delayed cardiac tamponade Case report
下载PDF
Arterial embolism caused by a peripherally inserted central catheter in a very premature infant:A case report and literature review 被引量:2
7
作者 Yi-Fei Huang Yan-Ling Hu +4 位作者 Xing-Li Wan Hong Cheng Yao-Hua Wu Xiao-Yan Yang Jing Shi 《World Journal of Clinical Cases》 SCIE 2020年第18期4259-4265,共7页
BACKGROUND Extremely premature infants have poor vascular conditions.Operators often choose deep veins such as the femoral vein and axillary vein to peripherally insert central catheters,and these vessels are often ac... BACKGROUND Extremely premature infants have poor vascular conditions.Operators often choose deep veins such as the femoral vein and axillary vein to peripherally insert central catheters,and these vessels are often accompanied by arteries;thus,it is easy to mistakenly enter the artery.CASE SUMMARY The case of an extremely premature infant(born at gestational age 28+3)in whom the left upper extremity artery was accidentally entered during peripheral puncture of the central venous catheter is reported.On the 19th day of hospitalization,the index finger,middle finger and ring finger of the left hand were rosy,the left radial artery and brachial artery pulse were palpable,the recovery was 95%,and the improvement was obvious.At discharge 42 d after admission,there was no abnormality in fingertip activity during the follow-up period.CONCLUSION Arterial embolization in preterm infants requires an individualized treatment strategy combined with local anticoagulation and 2%nitroglycerin ointment for local tissue damage caused by arterial embolism in the upper limb.Continuous visualization of disease changes using image visualization increases the likelihood of a good outcome. 展开更多
关键词 Arterial thrombosis ANTICOAGULATION NITROGLYCERIN Peripherally inserted central catheters Case report
下载PDF
Study on the microstructure and mechanical properties of medium carbon Cr-Si-Mn-Mo-V steel for cast inserted dies 被引量:1
8
作者 LIU Jin-hai LI Guo-lu +1 位作者 HAO Xiao-yan LIU Gen-sheng 《China Foundry》 SCIE CAS 2005年第4期260-263,共4页
The microstructure and mechanical properties of cast inserted dies for automobile covering components were studied. The results show that the as-cast microstructures of cast inserted dies are composed of pearlite, mar... The microstructure and mechanical properties of cast inserted dies for automobile covering components were studied. The results show that the as-cast microstructures of cast inserted dies are composed of pearlite, martensite, bainite, and austenite; and that the annealed microstructure is granular pearlite. The mechanical properties of cast inserted dies approach that of forged inserted dies. The tensile strength is 855 MPa, the elongation is 16%, the impact toughness is 177 J/cm2, and the hardness after annealing and quenching are HRC 19 and HRC 60-62. In addition, the cast inserted dies have good hardenability. The depth of the hardening zone and the hardness after flame quenching satisfy the operating requirements. The cast inserted dies could completely replace the forged inserted dies for making the dies of automobile covering components. 展开更多
关键词 STEEL CASTINGS inserted die microstructure mechanical properties FLAME QUENCHING
下载PDF
Influence of an inserted bar on the flow regimes in the hopper 被引量:1
9
作者 彭毅 张晟 +4 位作者 王梦柯 杨光辉 万江锋 陈良文 杨磊 《Chinese Physics B》 SCIE EI CAS CSCD 2021年第2期535-539,共5页
We investigated the influence of an inserted bar on the hopper flow experimentally.Three geometrical parameters,size of upper outlet D1,size of lower outlet D0,and the height of bar H,are variables here.With varying H... We investigated the influence of an inserted bar on the hopper flow experimentally.Three geometrical parameters,size of upper outlet D1,size of lower outlet D0,and the height of bar H,are variables here.With varying H we found three regimes:one transition from clogging to a surface flow and another transition from a surface flow to a dense flow.For the dense flow,the flow rate follows Beverloo’s law and there is a saturation of inclination of free surfaceθ.We plotted the velocity field and there is a uniform linear relation between the particle velocity and depth from the free surface.We also found that the required value of D_(1) to guarantee the connectivity of flow is little smaller than D_(0).For the transition from a surface flow to a dense flow,there is a jump of flow rate and the minimumθfor flowing is two degrees larger than the repose angle. 展开更多
关键词 hopper flow inserted bar flow type transition free surface velocity distribution
下载PDF
Peripherally inserted central catheter placement in neonates with persistent left superior vena cava: Report of eight cases 被引量:1
10
作者 Qiong Chen Yan-Ling Hu +1 位作者 Ying-Xin Li Xi Huang 《World Journal of Clinical Cases》 SCIE 2021年第26期7944-7953,共10页
BACKGROUND Reports on peripherally inserted central catheter(PICC)placement in neonates with persistent left superior vena cava(PLSVC)are rare.The majority of PLSVC patients have no clinical symptoms or hemodynamic ch... BACKGROUND Reports on peripherally inserted central catheter(PICC)placement in neonates with persistent left superior vena cava(PLSVC)are rare.The majority of PLSVC patients have no clinical symptoms or hemodynamic changes,which are usually detected during cardiac catheterization,cardiac pacemaker implantation,or PICC placement.However,in neonates with PLSVC,PICC placement can be challenging.Here,we report PICC placement in eight neonates with PLSVC.CASE SUMMARY This article introduces the concept of the“TIMB”bundle.After PICC implantation,we found PLSVC in all eight patients.The key points of care regarding PICC placement in neonates with PLSVC included“TIMB”,where“T”indicates a reasonable choice of the catheterization time,“I”refers to a retrospective analysis of imaging data before catheterization,“M”refers to correct measurement of the body surface length,and“B”indicates that the tip of the PICC is placed in the middle and lower 1/3 of the left superior vena cava under the guidance of B-ultrasound.CONCLUSION“TIMB”is a bundle for PICC placement in neonates,especially for those with PLSVC.Using this new approach can improve the first-attempt success rate of PICC placement,reveal cardiovascular abnormalities in advance,allow the selection of different measurement methods reasonably according to the puncture site,and finally,improve the accuracy of catheter positioning through the use of B-ultrasound guidance. 展开更多
关键词 NEONATE Persistent left superior vena cava Peripherally inserted central catheter COMPLICATIONS “TIMB”bundle Case report
下载PDF
An Unusual Peripherally Inserted Central Catheter (PICC) Fractured <i>in Vivo</i>with Embolization Happened in a Child: A Case Report 被引量:2
11
作者 Fang Fang Hongyan Zhang Wu Yang 《Case Reports in Clinical Medicine》 2015年第1期10-13,共4页
We report a case of a 7-year-old child who received a peripherally inserted central catheter (PICC) for chemotherapy. He suffered from an unusual PICC fracture in vivo with pulmonary embolism after eight circles of ch... We report a case of a 7-year-old child who received a peripherally inserted central catheter (PICC) for chemotherapy. He suffered from an unusual PICC fracture in vivo with pulmonary embolism after eight circles of chemotherapeutic agents administered. In this case report, we review the literatures for the underlying pathophysiology of this uncommon phenomenon. IV nurses should consider the possibility of the infusion dysfunction deriving from the PICC line fractured. Accurate tip catheter placement and specific care may reduce morbidity. 展开更多
关键词 Peripherally inserted Central CATHETER Fracture Children COMPLICATION
下载PDF
A Peripherally Inserted Central Vein Catheter Fractured and Slid into the Right Pulmonary Artery:A Case Report 被引量:2
12
作者 Meng Hu Zhi-Cheng Ma +5 位作者 Jie Zhang Fang Hu Xiao-Yu Liang Xiang-Chen Dai Hai-Lun Fan Jie-Chang Zhu 《Chinese Nursing Research》 CAS 2015年第2期84-87,共4页
Catheter fracture is a rare but serious complication of a peripherally inserted central catheter (PICC). An adolescent patient was sent to Tianjin Medical University General Hospital (Tianjin, China) because the P... Catheter fracture is a rare but serious complication of a peripherally inserted central catheter (PICC). An adolescent patient was sent to Tianjin Medical University General Hospital (Tianjin, China) because the PICC was fractured when removed by a nurse. Chest X-ray showed that the PICC fragment slid into the right pulmonary artery. Through emergency surgery, the remainder of the PICC was successfully retrieved by an interventional operation percutaneously via the right femoral vein. PICC fracture is less common and always without significant discomfort if not found timely, and it may lead to serious complications, such as pulmonary embolism, and even death. Thus, nurses, patients and their family members should pay enough attention to the daily maintenance of PICC and have a deep understanding of the reasons associated with PICC fracture as well as how to prevent it. Interventional operation is minimally invasive, which is a good choice for the removal of intravascular foreign bodies, leading to fewer complications and a good prognosis. 展开更多
关键词 Peripherally inserted cenwal catheter Catheter fracture Interventional operation
下载PDF
Experimental investigation on hard rock fragmentation of inserted tooth cutter using a newly designed indentation testing apparatus
13
作者 Jiuqun Zou Weihao Yang +2 位作者 Tao Zhang Xiaofei Wang Min Gao 《International Journal of Mining Science and Technology》 SCIE EI CAS CSCD 2022年第3期459-470,共12页
This investigation aims to explore the effects of stress conditions and rock cutting rates on hard rock fragmentation through indentation tests on a newly designed triaxial testing apparatus.This apparatus was designe... This investigation aims to explore the effects of stress conditions and rock cutting rates on hard rock fragmentation through indentation tests on a newly designed triaxial testing apparatus.This apparatus was designed to realize a triaxial loading and indentation test of cylindrical specimens using inserted tooth cutter.The boreability and crushing efficiency of granite rock was investigated by analyzing the change rules of the thrusting force,penetration depth,characteristics of chippings and failure patterns.Several quantitative indexes were used to evaluate rock boreability in this investigation.The granite rock samples all had a chiselled pit and a crushed rock core.Under initial stress conditions,only flat-shape chippings were stripped from the rock surface when the thrusting force reached 20 kN.The rock cutting special energy had a close correlation with the initial stress conditions and inserted tooth shape.Moreover,a thrusting force prediction model was proposed in this paper.The contribution of this study is that for the first time the influence mechanism of the initial triaxial stress conditions on rock fragmentation is investigated using an inserted tooth and the newly designed testing apparatus.This study has a crucial importance for practical underground hard rock crushing in geoengineering. 展开更多
关键词 Hard rock indentation test Hard rock fragmentation Triaxial confined conditions New triaxial testing apparatus inserted tooth cutter Cylindrical rock specimens
下载PDF
Analysis of Use and Outcomes of Peripherally Inserted Central Catheter (PICC-Line) in Hemato-Oncological Patients
14
作者 Sulav Sapkota Radheshyam Naik 《Journal of Cancer Therapy》 2018年第1期35-41,共7页
Aims: To audit the use and outcomes of using PICC lines in hemato-oncological patients. Objectives: To study the demographics of patients: ?studying the use of PICC line in hemato-oncological patients;studying the rat... Aims: To audit the use and outcomes of using PICC lines in hemato-oncological patients. Objectives: To study the demographics of patients: ?studying the use of PICC line in hemato-oncological patients;studying the rate of complications in PICC line;studying the cause of early removal of PICC line. Methods: All PICCs inserted in adult hemato-oncological patients in Hematology and Medical Oncology Department of Health Care Global (HCG) Hospital were studied prospectively, as per the proforma, till PICCs were removed or patient expired and the pattern of complications were noted. Results: Eighty-four PICCs were inserted over a period of initial nine months and followed for a total of 1 year with three months post insertion duration for a total of 10,868 catheter-days (mean of 129 days i.e. 4.3 months, range: 1 to 288 days). The most common indication for PICC was chemotherapy (100%). Among them 19 (22%) PICCs had complications and 12 were removed at the rate of 1.1/1000 PICC-days. Complications with haematologic malignancies were more as compared to those with solid tissue malignancies. Conclusions: Despite significant complication rates, PICCs are a relatively safe and cost effective mode of establishing central venous access. 展开更多
关键词 Peripherally inserted CENTRAL CATHETER (PICC) Vascular Access Device (VAD) Catheter-Related BLOODSTREAM Infection (CR-BSI) Eastern Cooperative ONCOLOGY Group Performance Status (ECOG PS) CENTRAL VENOUS CATHETER (CVC)
下载PDF
Aesthetic gingival management: Preservation of the anatomical structures and the gingival aesthetics by immediate implant-insertion after loss of anterior teeth and premolars—Results of a 5-year prospective study with 348 inserted one-phase implants 被引量:2
15
作者 Angelo Troedhan Izabela Schlichting Andreas Kurrek 《Open Journal of Stomatology》 2013年第2期146-154,共9页
Implant insertion is an alternative to classical treatment with bridges after tooth extraction or traumatic tooth loss in the anterior and premolar region of the upper and lower jaw. Nevertheless both types of prosthe... Implant insertion is an alternative to classical treatment with bridges after tooth extraction or traumatic tooth loss in the anterior and premolar region of the upper and lower jaw. Nevertheless both types of prosthetic treatment inhere major gingival aesthetic pitfalls by physiological vertical and horizontal resorption. Aim of the study was to investigate if the immediate insertion of root analogue single-stage implants and prosthetic treatment could prevent gingival recessions and bone resorption thus keeping the natural gingival aesthetics untouched. Between 2003 and 2006, 348 root analogue Q1-Implants (TRINON Karlsruhe GmbH/Germany) were inserted in 342 patients’s premolar and molar regions immediately after tooth extraction or traumatic tooth loss and treated with provisional resin crowns. The observation period with recurring 6-month clinical and radiographic check-ups was a minimum of 5 years. Of 348 inserted implants 4 (1.15%) were lost resulting in an overall success rate of 98.85%. In the first 12 weeks after surgery a mean recession of the buccal gingival margin of 0.2 mm (SD 0.34) could be detected, after final prosthetic treatment an overall mean recession of 0.2 mm (SD 0.13) within the survey period. Immediate implant insertion of root analogue single stage implants and immediate prosthetic treatment with provisional resin crowns after minimal invasive tooth extraction seems to be appropriate to prevent bone resorptions of the buccal alveolar crest and the recessions of the gingiva and papillae and thus suggests to be the preferable treatment to keep the natural gingival and papillary aesthetics untouched preventing further traumatic surgical gingival reconstructions. 展开更多
关键词 Oral IMPLANTOLOGY Single Phase IMPLANTS IMMEDIATE Implant INSERTION GINGIVAL Aesthetics
下载PDF
Optical Interface Phonon in Thin Layer Inserted Quantum Well Structure
16
作者 GU Bing-lin DUAN Wen-hui XIONG Shi-ying 《Chinese Physics Letters》 SCIE CAS CSCD 1996年第10期768-771,共4页
The dependence of optical interface phonon on structure was demonstrated for thin layer inserted GaAlAs quantum well structures. It was found that the dispersion is sensitive to the Al-content of the inserted layer bu... The dependence of optical interface phonon on structure was demonstrated for thin layer inserted GaAlAs quantum well structures. It was found that the dispersion is sensitive to the Al-content of the inserted layer but almost independent of the position of the layer. The results showed that phonon modes can be modulated by adjusting the well parameters, which is useful for some device applications. 展开更多
关键词 QUANTUM INSERT DISPERSION
下载PDF
Identification of T-DNA Inserted Mutant Gene Transcription by Using Real-time PCR in Arabidopsis
17
作者 YUAN Man BAI Xi CAI Hua LI Yong JI Wei ZHU Yanming 《Journal of Northeast Agricultural University(English Edition)》 CAS 2011年第2期41-47,共7页
AtERF4 (ethylene response factor) is a negative regulator in jasmonic acid mediated signal transduction pathway and ethylene mediated signal transduction pathway of Arabidopsis. It could respond to abscisic acid (... AtERF4 (ethylene response factor) is a negative regulator in jasmonic acid mediated signal transduction pathway and ethylene mediated signal transduction pathway of Arabidopsis. It could respond to abscisic acid (ABA) and ethylene stimulus ATSYR1 gene encodes a syntaxin localizing at the plasma membrane in Arabidopsis, which can be induced by abiotic stress. To identify mutation lines for gene functional analysis, real-time PCR was employed to detect the expression level of AtERF4 and ATSYR1 in homozygous T-DNA insertion mutant line, respectively. Real-time PCR is a powerful tool which can be used to detect steady-state mRNA levels specifically, sensitively and reproducibly. Comparing to other forms of quantitative RT-PCR, the amount of amplified products can be detected by real-time PCR instantly and thus is a preferable alternative. In this study, RNA with T-DNA inserting into exon could be detected in AtERF4 knock-out mutation line. The results indicated that AtERF4 had been trucked in transcription level. On the other hand, T-DNA inserting into the promoter of gene ATSYR1 had no effect on reducing the expression level ofATSYR1 gene. Further molecular and phenotype studies now are ongoing to clarify the potential consequences of AtERF4 and ATSYR1 deficiency in Arabidopsis 展开更多
关键词 Arabidopsis thaliana ERF4 SYR1 T-DNA insertion real-time PCR
下载PDF
Tip orientation under real-time point-of-care neck ultrasonic monitoring is advantageous in peripherally inserted central catheter procedures:a retrospective cohort study
18
作者 Shuiqing Liu Shaowei Jiang +2 位作者 Jing Ma Feng Qian Chengjin Gao 《Emergency and Critical Care Medicine》 2023年第2期57-63,共7页
Background:We analyzed the success and catheter tip malposition rates of peripherally inserted central catheter(PICC)placement using ultrasonic monitoring.Methods:A total of 564 patients were recruited and assigned to... Background:We analyzed the success and catheter tip malposition rates of peripherally inserted central catheter(PICC)placement using ultrasonic monitoring.Methods:A total of 564 patients were recruited and assigned to either the intervention or control group.In the intervention group,282 patients underwent ultrasound-guided PICC insertion,which helped to identify the position and depth of the catheter tip.From a total of 9000 patients,282 were selectively chosen to receive the traditional method using body surface measurements(control group).The primary endpoint was the success rate;the secondary endpoint was the catheter tip malposition rate as detected by postprocedure chest radiography.Results:In the intervention group,a total of 94 catheters were in a suboptimal position;26 were too deep,68 were too shallow,and 1 was inserted into the subclavian vein,with success and malposition rates of 66.3%and 0.4%,respectively.In the control group,139 catheters were in a suboptimal position;88 were too deep,51 were too shallow,9 were inserted into the jugular vein,and 2 were inserted into the subclavian vein,with success and malposition rates of 46.8%(P<0.001)and 3.9%(P=0.004),respectively.Significant differences were observed in success and malposition rates between the 2 groups.Conclusion:Ultrasound-guided PICC procedures achieved higher success rates and lower malposition rates. 展开更多
关键词 Catheter tip depth precision Catheter tip malposition Peripherally inserted central catheter Superior vena cava Ultrasound
原文传递
Reversible Optical Isolators and Quasi-Circulators Using a Magneto-Optical Fabry-Pérot Cavity
19
作者 张天天 周文鹏 +7 位作者 李志向 唐宇涛 许帆 吴浩东 张涵 唐江山 阮亚平 夏可宇 《Chinese Physics Letters》 SCIE EI CAS CSCD 2024年第4期59-68,共10页
Nonreciprocal optical devices are essential for laser protection,modern optical communication and quantum information processing by enforcing one-way light propagation.The conventional Faraday magneto-optical nonrecip... Nonreciprocal optical devices are essential for laser protection,modern optical communication and quantum information processing by enforcing one-way light propagation.The conventional Faraday magneto-optical nonreciprocal devices rely on a strong magnetic field,which is provided by a permanent magnet.As a result,the isolation direction of such devices is fixed and severely restricts their applications in quantum networks.In this work,we experimentally demonstrate the simultaneous one-way transmission and unidirectional reflection by using a magneto-optical Fabry-Pérot cavity and a magnetic field strength of 50 mT.An optical isolator and a three-port quasi-circulator are realized based on this nonreciprocal cavity system.The isolator achieves an isolation ratio of up to 22 dB and an averaged insertion loss down to 0.97 dB.The quasi-circulator is realized with a fidelity exceeding 99% and an overall survival probability of 89.9%,corresponding to an insertion loss of~0.46 dB.The magnetic field is provided by an electromagnetic coil,thereby allowing for reversing the light circulating path.The reversible quasi-circulator paves the way for building reconfigurable quantum networks. 展开更多
关键词 quantum reciprocal INSERTION
下载PDF
An efficient method for constructing a random insertional mutant library for forward genetics in Nannochloropsis oceanica
20
作者 Zhongyi ZHANG Hang LIU +5 位作者 Xiaohui PAN Yanan ZONG Leili FENG Lixian LIU Li GUO Guanpin YANG 《Journal of Oceanology and Limnology》 SCIE CAS CSCD 2024年第1期216-225,共10页
Insertional mutation,phenotypic evaluation,and mutated gene cloning are widely used to clone genes from scratch.Exogenous genes can be integrated into the genome during non-homologous end joining(NHEJ)of the double-st... Insertional mutation,phenotypic evaluation,and mutated gene cloning are widely used to clone genes from scratch.Exogenous genes can be integrated into the genome during non-homologous end joining(NHEJ)of the double-strand breaks of DNA,causing insertional mutation.The random insertional mutant library constructed using this method has become a method of forward genetics for gene cloning.However,the establishment of a random insertional mutant library requires a high transformation efficiency of exogenous genes.Many microalgal species show a low transformation efficiency,making constructing random insertional mutant libraries difficult.In this study,we established a highly efficient transformation method for constructing a random insertional mutant library of Nannochloropsis oceanica,and tentatively tried to isolate its genes to prove the feasibility of the method.A gene that may control the growth rate and cell size was identified.This method will facilitate the genetic studies of N.oceanica,which should also be a reference for other microalgal species. 展开更多