The insertion torque of a dental implant is an important indicator for the primary stability of dental implants.Thus,the preoperative prediction for the insertion torque is crucial to improve the success rate of impla...The insertion torque of a dental implant is an important indicator for the primary stability of dental implants.Thus,the preoperative prediction for the insertion torque is crucial to improve the success rate of implantation surgery.In this present research,an alternative method for prediction of implant torque was proposed.First,the mechanical model for the insertion torque was established based on an oblique cutting process.In the proposed mechanical model,three factors,including bone quality,implant geometry and surgical methods were considered in terms of bone-quality coefficients,chip load and insertion speeds,respectively.Then,the defined bone-quality coefficients for cancellous bone with the computed tomography(CT)value of 235–245,345–355 and 415–425 Hu were obtained by a series of insertion experiments of IS and ITI implants.Finally,the insertion experiments of DIO implants were carried out to verify the accuracy of developed model.The predicted insertion torques calculated by the mechanical model were compared with those acquired by insertion experiments,with good agreement,the relative error being less than 15%.This method allows the insertion torque for different implant types to be quickly established and enhances prediction accuracy by considering the effects of implants’geometries and surgical methods.展开更多
The stability parameters of implants (ITV, ISQ & PTV) according to different sizes of controlled bone defects made in implant osteotomies were analyzed and the correlation among the three kinds of implant stability...The stability parameters of implants (ITV, ISQ & PTV) according to different sizes of controlled bone defects made in implant osteotomies were analyzed and the correlation among the three kinds of implant stability parameters was tested in this study. 45 tapped screw-type dental implants were inserted in three types of implant osteotomies made in 8 fresh-frozen pig femoral bones: Typel - without coronal bone defect, Type2 - with 3 mm coronal bone defects, and Type3 - with 6 mm coronal bone defects. The insertion torque values, ISQ & PTV of implants were measured and analyzed statistically. It is concluded that the circumferential coronal bone defects statistically influence the primary stability of implants; ITV, ISQ and PTV are suitable and available to detect the peri-implant coronal bone defects in 3 mm increments, and ITV and PTV are more sensitive to coronal cortical bone loss. There was a strong correlation between ITV and ISQ.展开更多
基金Major Research&Development Program of Shandong Province(Grant No.2015GGX103043)Taishan Scholars Program of Shandong Province(Grant No.ts201712002).
文摘The insertion torque of a dental implant is an important indicator for the primary stability of dental implants.Thus,the preoperative prediction for the insertion torque is crucial to improve the success rate of implantation surgery.In this present research,an alternative method for prediction of implant torque was proposed.First,the mechanical model for the insertion torque was established based on an oblique cutting process.In the proposed mechanical model,three factors,including bone quality,implant geometry and surgical methods were considered in terms of bone-quality coefficients,chip load and insertion speeds,respectively.Then,the defined bone-quality coefficients for cancellous bone with the computed tomography(CT)value of 235–245,345–355 and 415–425 Hu were obtained by a series of insertion experiments of IS and ITI implants.Finally,the insertion experiments of DIO implants were carried out to verify the accuracy of developed model.The predicted insertion torques calculated by the mechanical model were compared with those acquired by insertion experiments,with good agreement,the relative error being less than 15%.This method allows the insertion torque for different implant types to be quickly established and enhances prediction accuracy by considering the effects of implants’geometries and surgical methods.
基金Sponsored by the Scientific Research Foundation for the Returned Overseas Chinese Scholars,Ministry of Education,China
文摘The stability parameters of implants (ITV, ISQ & PTV) according to different sizes of controlled bone defects made in implant osteotomies were analyzed and the correlation among the three kinds of implant stability parameters was tested in this study. 45 tapped screw-type dental implants were inserted in three types of implant osteotomies made in 8 fresh-frozen pig femoral bones: Typel - without coronal bone defect, Type2 - with 3 mm coronal bone defects, and Type3 - with 6 mm coronal bone defects. The insertion torque values, ISQ & PTV of implants were measured and analyzed statistically. It is concluded that the circumferential coronal bone defects statistically influence the primary stability of implants; ITV, ISQ and PTV are suitable and available to detect the peri-implant coronal bone defects in 3 mm increments, and ITV and PTV are more sensitive to coronal cortical bone loss. There was a strong correlation between ITV and ISQ.