期刊文献+
共找到658篇文章
< 1 2 33 >
每页显示 20 50 100
Tubular Heat Enhancement Using Twisted Tape Inserts with Large Holes
1
作者 Ali Jaber Abdulhamed Aws Al-Akam +1 位作者 Wisam J.Khudhayer Ali Sabri Allw 《Energy Engineering》 EI 2024年第2期273-290,共18页
Heat augmentation techniques play a vital role in the heating and cooling processes in industries,including solar collectors and many applications that utilize heat exchangers.Several studies are based on inserting fi... Heat augmentation techniques play a vital role in the heating and cooling processes in industries,including solar collectors and many applications that utilize heat exchangers.Several studies are based on inserting fillers inside the tubes to enhance heat transfer.This investigation considered the effects of twisted tapes with large holes on a tubular heat exchanger’s(HX)heat transmission,pressure drop,and thermal boosting factor.In the experimental section,counter-swirl flow generators used twisted tapes with pairs of 1.0 cm-diameter holes and changes in porosity(Rp)at 1.30%and 2.70%.In the experiments,air was utilized as a working fluid in a tube with a circular cross-section.The turbulent flow was considered,with Reynolds numbers(Re)domain from 4800 to 9500,and a boundary condition with a uniform wall heat flux was constructed.The findings expound that when the number of holes rose,the Nusselt number(Nu),the factor of friction(f),and the thermal enhancement factor(η)all increased as well.Additionally,as the friction factor increased,the Nusselt number of the tape-equipped tube was noticeably higher.Additionally,it was discovered that the friction factor was between 70%and 94%lower than the values of the tube without tape,while the(Nu)was between 87%and 97%higher than the conventional tube values.The maximum value ofηis 89%.According to the experimental results,empirical correlations for Nu,f,andηwere also generated. 展开更多
关键词 TUBULAR heat exchanger tape inserts twisted tape
下载PDF
Health Monitoring of Milling Tool Inserts Using CNN Architectures Trained by Vibration Spectrograms 被引量:1
2
作者 Sonali S.Patil Sujit S.Pardeshi Abhishek D.Patange 《Computer Modeling in Engineering & Sciences》 SCIE EI 2023年第7期177-199,共23页
In-process damage to a cutting tool degrades the surface􀀀nish of the job shaped by machining and causes a signi􀀀cant􀀀nancial loss.This stimulates the need for Tool Condition Monitoring(TCM)t... In-process damage to a cutting tool degrades the surface􀀀nish of the job shaped by machining and causes a signi􀀀cant􀀀nancial loss.This stimulates the need for Tool Condition Monitoring(TCM)to assist detection of failure before it extends to the worse phase.Machine Learning(ML)based TCM has been extensively explored in the last decade.However,most of the research is now directed toward Deep Learning(DL).The“Deep”formulation,hierarchical compositionality,distributed representation and end-to-end learning of Neural Nets need to be explored to create a generalized TCM framework to perform eciently in a high-noise environment of cross-domain machining.With this motivation,the design of dierent CNN(Convolutional Neural Network)architectures such as AlexNet,ResNet-50,LeNet-5,and VGG-16 is presented in this paper.Real-time spindle vibrations corresponding to healthy and various faulty con􀀀gurations of milling cutter were acquired.This data was transformed into the time-frequency domain and further processed by proposed architectures in graphical form,i.e.,spectrogram.The model is trained,tested,and validated considering dierent datasets and showcased promising results. 展开更多
关键词 Milling tool inserts health monitoring vibration spectrograms deep learning convolutional neural network
下载PDF
Effect of the Arrangement of a New-Type of Turbulator Inserts on Heat Pipe Exchanger Performances
3
作者 Ibtisam A.Hasan Wafa Maki 《Fluid Dynamics & Materials Processing》 EI 2023年第10期2749-2759,共11页
This research tests the effect of introducing turbulators of a new type into a circular tube heat exchanger under a constant and uniform longitudinal heatflux condition.A 45 mm diameter copper tube with a length of 1,3... This research tests the effect of introducing turbulators of a new type into a circular tube heat exchanger under a constant and uniform longitudinal heatflux condition.A 45 mm diameter copper tube with a length of 1,350 mm is utilized with a solid disk being inserted inside the tube,which consists of three sections,each one containing two slots.The slot is cut at a 45 degree angle toward the inner tube surface,which results in diverging theflow toward the inner hot tube surface in order to enhance the heat transfer process.Air is considered as the workingfluid with Prandtl number 0.71.The Reynolds number spans the interval from 6,000–13,500,which indicates that the consideredflow is turbulent.The heat exchanger performance is studied and analyzed in terms of average Nusselt number.The experimental results show that the Nusselt number value is directly proportional to the increase of the Reynolds number,and the number of turbulators inserts.With the use of three novel turbulators,the heat transfer was about 3.15 times higher than that in the smooth tube and the friction factor was about 1.11. 展开更多
关键词 Heat pipe exchanger heat transfer inserts(NT inserts) turbulators(novel turbulators) disk(solid disk)
下载PDF
Analysis of Friction and Heat Transfer Characteristics of Tubes with Trapezoidal Cut Twisted Tape Inserts
4
作者 Shrikant Arunrao Thote Netra Pal Singh 《Fluid Dynamics & Materials Processing》 EI 2023年第3期711-722,共12页
The thermo-hydraulic properties of circular tubes with a twisted tape inside(used accordingly to induce turbulence and enhance heat transfer through the tube wall)are described for Reynolds Numbers ranging from 830 to... The thermo-hydraulic properties of circular tubes with a twisted tape inside(used accordingly to induce turbulence and enhance heat transfer through the tube wall)are described for Reynolds Numbers ranging from 830 to 1990.Tapes twisted with the three distinct twist ratios are considered,namely,6,4.4 and 3.Air is used as the working fluid in several tests.For the sake of comparison,the standard tube with no insert is also examined.It is shown that in the presence of the twisted tape,the‘frictional factor’,‘Nusselt Number’and the‘thermal performance factor’are much higher than those obtained for the plain tube.Moreover,the tapes having the lowest twist ratio,i.e.,3,are more effective than the others in terms of heat transfer augmentation.The‘thermal performance factor’is greater than one for all the twisted tapes used in the experiments,which confirms the enhanced performances of the heat exchanger and the related savings in terms of total energy. 展开更多
关键词 Friction factor nusselt number performance ratio trapezoidal cut twisted tape insert
下载PDF
Performance Enhancement of the Proton Exchange Membrane Fuel Cell Using Pin Type Flow Channel with Porous Inserts 被引量:1
5
作者 Vaibhav Pal P. Karthikeyan R. Anand 《Journal of Power and Energy Engineering》 2015年第5期1-10,共10页
The design of the flow field is highly responsible for the performance of the Proton Exchange Membrane Fuel Cell (PEMFC). In this study, pin type flow channel is numerically analyzed by arranging carbon made porous ma... The design of the flow field is highly responsible for the performance of the Proton Exchange Membrane Fuel Cell (PEMFC). In this study, pin type flow channel is numerically analyzed by arranging carbon made porous material in uniform and zigzag manner on the rib surface of the flow field. The study focuses on enhancing the performance of PEMFC by reducing liquid flooding in the interface between the rib and Gas Diffusion Layer (GDL). A single PEMFC having an active area of 25 cm2, with three flow channel designs (conventional serpentine, pin type flow channel with 2 mm cubical porous inserts in zigzag and uniform pattern) are modeled for the numerical analysis. The effect of porosity of the carbon inserts on the cell performance is studied by varying its value from 0.6 to 0.9. The results show that the performance of the flow channel with zigzag and uniformly positioned porous inserts is more than the conventional serpentine flow channel by 20.36% and 16.87% respectively. The reason for this increase is the removal of the accumulated water from the rib surface due to the capillary action of the porous carbon inserts. This helps in eliminating the stagnant water regions under the rib and thereby helps in reducing liquid flooding. 展开更多
关键词 FLOODING Uniform and ZIGZAG PIN TYPE Porosity POROUS Carbon inserts
下载PDF
Measuring compliance of package inserts in the Emirate of Abu Dhabi—UAE
6
作者 Hadaya Gharibyar Yasser Sharif +2 位作者 Sherif El Ghandour Maysoon Saffarini Bashir Aden 《Health》 2013年第5期834-837,共4页
Purpose: The aim of this study was to examine if package inserts (PIs) supplied with prescribed medications in the Emirate of Abu Dhabi contain all relevant information to the safe and appropriate use of these medicat... Purpose: The aim of this study was to examine if package inserts (PIs) supplied with prescribed medications in the Emirate of Abu Dhabi contain all relevant information to the safe and appropriate use of these medications. Methods: Sixty seven PIs for prescription—only medications were evaluated against a set of safety criteria published from the Ministry of Health. Results: Analyzed PIs showed many deficiencies with regard to the Ministry of Health (MOH) Investigation New Drug Application (INDA) requirements. Particularly of concern were side effects, warnings, use in pregnancy, lactation, and the storage conditions for the product. Conclusions: This study indicated that information relevant to the safe and appropriate use of medications was not uniformly mentioned in the PIs analyzed. To avoid medication errors due to deficits in the current PIs, we recommend regulatory oversight and regulator audits from pharmaceutical company, followed by enhancement of regulations requiring companies to also create patient information leaflets. 展开更多
关键词 DRUG LABELING Generic MEDICATIONS ADVERSE Reactions DRUG Safety PHARMACOEPIDEMIOLOGY DRUG Information Abu Dhabi UAE Package inserts
下载PDF
Comparing the Effectiveness of Coatings on Carbide andCermet Cutting Tool Inserts
7
作者 K.H. W.Seah M.Rahman and C.H.Lee (Dept. of Mech. & Prod. Eng., National University of Singapore, 10 Kent Ridge Crescent, Singapore 0511 T.N.Goh (Dept. of Ind. & Sys. Eng., National University of Singapore, 10 Kent Ridge Crescent, Singapore 0511) 《Journal of Materials Science & Technology》 SCIE EI CAS CSCD 1995年第4期269-275,共7页
A series of metal cutting experiments was performed on a CNC lathe to evaluate the performance of various coatings on different tool substrates. The workpiece material was plain medium carbon steel and the cutting too... A series of metal cutting experiments was performed on a CNC lathe to evaluate the performance of various coatings on different tool substrates. The workpiece material was plain medium carbon steel and the cutting tool materials were carbide and cermet inserts coated with various single as well as multilayer coatings. Machining was done under various cutting conditions of speed and feed-rate, and for various durations of Cutting. The output parameters studied were the cutting forces (axial, radial and tangential), the surface roughness of the workpiece, as well as the tool wear (crater and flank wear). From these results, the performances of the various cutting inserts are evaluated and compared. Results show that cutting forces are significantly lower when using coated cermets than when using coated carbides although different coatings on the same substrate also result in different cutting forces. However, there is less difference in the surface roughness of the finished workpiece for the various coatings and substrates. 展开更多
关键词 TOOL Comparing the Effectiveness of Coatings on Carbide andCermet Cutting Tool inserts
下载PDF
Wear Mechanisms of Ceramic Inserts in Machining Nickel-Based Superalloy
8
作者 肖茂华 何宁 +1 位作者 李亮 陆爱华 《Journal of Southwest Jiaotong University(English Edition)》 2010年第1期59-64,共6页
The performances of ceramic inserts in cutting nickel-based alloy were investigated. A new cutting test-bed was devised and used to deburr. The burr height on the working surface with notch wear in deburring cutting w... The performances of ceramic inserts in cutting nickel-based alloy were investigated. A new cutting test-bed was devised and used to deburr. The burr height on the working surface with notch wear in deburring cutting was compared with that in normal cutting. The impact force, impact pressure, and impact frequency of the saw-tooth-shaped chip edge on rake face and cutting edge at different speeds were calculated, and the influence of chip edge on notch wear formation was analyzed. A new tool design for reducing notch wear was presented, which is flexible and can deburr effectively. 展开更多
关键词 Tool wear MECHANISM Notch wear Ceramic inserts Nickel-based superalloy
下载PDF
Simulation of Heat Transfer in a Tubular Pipe Using Different Twisted Tape Inserts
9
作者 Md. Moniruzzaman Bhuyan Ujjwal K. Deb +1 位作者 M. Shahriar Simul Acherjee 《Open Journal of Fluid Dynamics》 2017年第3期397-409,共13页
This paper performs a simulation study of the heat transfer phenomena in a tubular U-loop pipe. We have investigated the enhancement of heat transfer with mass flow in a pipe without insert, with full length and short... This paper performs a simulation study of the heat transfer phenomena in a tubular U-loop pipe. We have investigated the enhancement of heat transfer with mass flow in a pipe without insert, with full length and short length twisted tape inserts. The length of the pipe is approximately 2436.80 mm long with 29 mm inner and 33 mm outer diameter respectively. A constant heat flux is taken which generated the boundary layer of the pipe close to the flowing fluid around the boundary. The simulations are considered for the stationary and the time dependent module for 35 seconds with different length of inserts. The comparisons are made among the results. We observed that the transfer of heat is enhanced significantly with the increase of the length of inserts inside the computational domain. We also found that, full length twisted tape inserts are more effective than comparing with the short length inserts and without insert. 展开更多
关键词 Heat Transfer NON-ISOTHERMAL Flow TUBULAR PIPE TWISTED Tape inserts SIMULATION
下载PDF
Influence of Thermal Load on Mechanical Property of Cemented Carbide Material and Heavy Cemented Carbide Inserts Life 被引量:2
10
作者 Yao-Nan Cheng Li Liu +3 位作者 Shou-Hui Sun Jun Qian Ya-Nan Gong Ming-Yang Wu 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2013年第6期59-66,共8页
A large amount of cutting heat is produced during the heavy cutting process,and insert life is restricted by the effect of thermal load. The thermal load experiment of cemented carbide SCS,WF and YT15 is carried out,a... A large amount of cutting heat is produced during the heavy cutting process,and insert life is restricted by the effect of thermal load. The thermal load experiment of cemented carbide SCS,WF and YT15 is carried out,and the results show that the bending strength and fracture toughness of cemented carbide material decrease obviously under cyclic thermal load,while in the cooling process,the material mechanical property changes worse suddenly. The high-temperature mechanical property of SCS is the most stable,and that of YT15is the worst. Further,a relation model among cutting temperature,cutting parameters and insert life is established. Finally,the measures to improve heavy cemented carbide inserts life are summarized from the aspects of cutting parameters selection,insert optimization design and TiCN,A12O3,TiN complex insert coating. The research results are expected to provide support and reference for heavy cutting technology and insert technology. 展开更多
关键词 thermal load cemented carbide mechanical property heavy cutting insert life
下载PDF
Improvement of thickness deposition uniformity in nickel electroforming for micro mold inserts 被引量:1
11
作者 蒋炳炎 翁灿 +2 位作者 周明勇 吕辉 DRUMMER Dietmar 《Journal of Central South University》 SCIE EI CAS CSCD 2016年第10期2536-2541,共6页
Thickness deposition is a crucial issue on the application of electroformed micro mold inserts. Edge concentration effect is the main source of the non-uniformity. The techniques of adopting a non-conducting shield, a... Thickness deposition is a crucial issue on the application of electroformed micro mold inserts. Edge concentration effect is the main source of the non-uniformity. The techniques of adopting a non-conducting shield, a secondary electrode and a movable cathode were explored to improve the thickness deposition uniformity during the nickel electroforming process. Regarding these techniques, a micro electroforming system with a movable cathode was particularly developed. The thickness variation of a 16 mm×16 mm electroformed sample decreased respectively from 150% to 35%, 12% and 18% by these three techniques. Combining these validated methods, anickelmold insert for microlens array was electroformed with satisfactory mechanical properties and high replication precision. It could be applied to the following injection molding process. 展开更多
关键词 deposition uniformity nickel electroforming secondary electrode non-conducting shield movable cathode micro mold insert
下载PDF
FABRICATION AND PROPERTIES OF CERAMIC -CEMENTED CARBIDE COMPACT INSERTS
12
作者 J.Q.Zhou,X.Ai,Z.Q.Li and C.Z.Huang Institute of Mechanical Engineering, Shandong University of Technology, Jinan 250061, China 《Acta Metallurgica Sinica(English Letters)》 SCIE EI CAS CSCD 1999年第5期1142-1146,共5页
A novel ceramic cemented carbide compact insert was developed using hot pressing sintering technique. The surface layers of the sandwich material were ceramic and the middle layer was cemented carbide. The factors tha... A novel ceramic cemented carbide compact insert was developed using hot pressing sintering technique. The surface layers of the sandwich material were ceramic and the middle layer was cemented carbide. The factors that affect the properties of the compact insert were analyzed. Theoretical analyses and experiments indicated that the cemented carbide with greater elastic module and thermal expansion coefficient than ceramic should be used in the sandwich material in order to get high equivalent flexure strength and the geometric parameters of the compact insert are also important to its properties. 展开更多
关键词 COMPACT insert hot PRESSING sintering CERAMIC CEMENTED CARBIDE
下载PDF
Esophageal inserted subclavian catheter:a rare complication
13
作者 DilberÜçöz Kocaşaban SertaçGüler 《World Journal of Emergency Medicine》 SCIE CAS CSCD 2024年第3期243-245,共3页
Central venous catheterization(CVC) is an invasive procedure for administering fluids,nutrients,and drugs;monitoring central venous pressure;performing pulmonary artery catheterization;and placing transvenous pacemake... Central venous catheterization(CVC) is an invasive procedure for administering fluids,nutrients,and drugs;monitoring central venous pressure;performing pulmonary artery catheterization;and placing transvenous pacemakers in intensive care units and all specialties,from anesthesia to emergency medicine,for the treatment of trauma and hemodynamically unstable pediatric and adult patients.[1,2]Complications have been observed in more than 15% of patients who underwent CVC.Mechanical,infectious,and thrombotic complications have been reported in 5%–19%,5%–26%,and 2%–26% of patients,respectively.[3] Malposition,on the other hand,is common in subclavian catheter insertion and is usually associated with an initially misplaced guidewire.[4] 展开更多
关键词 UNSTABLE INSERTION initially
下载PDF
Reversible Optical Isolators and Quasi-Circulators Using a Magneto-Optical Fabry-Pérot Cavity
14
作者 张天天 周文鹏 +7 位作者 李志向 唐宇涛 许帆 吴浩东 张涵 唐江山 阮亚平 夏可宇 《Chinese Physics Letters》 SCIE EI CAS CSCD 2024年第4期59-68,共10页
Nonreciprocal optical devices are essential for laser protection,modern optical communication and quantum information processing by enforcing one-way light propagation.The conventional Faraday magneto-optical nonrecip... Nonreciprocal optical devices are essential for laser protection,modern optical communication and quantum information processing by enforcing one-way light propagation.The conventional Faraday magneto-optical nonreciprocal devices rely on a strong magnetic field,which is provided by a permanent magnet.As a result,the isolation direction of such devices is fixed and severely restricts their applications in quantum networks.In this work,we experimentally demonstrate the simultaneous one-way transmission and unidirectional reflection by using a magneto-optical Fabry-Pérot cavity and a magnetic field strength of 50 mT.An optical isolator and a three-port quasi-circulator are realized based on this nonreciprocal cavity system.The isolator achieves an isolation ratio of up to 22 dB and an averaged insertion loss down to 0.97 dB.The quasi-circulator is realized with a fidelity exceeding 99% and an overall survival probability of 89.9%,corresponding to an insertion loss of~0.46 dB.The magnetic field is provided by an electromagnetic coil,thereby allowing for reversing the light circulating path.The reversible quasi-circulator paves the way for building reconfigurable quantum networks. 展开更多
关键词 quantum reciprocal INSERTION
下载PDF
An efficient method for constructing a random insertional mutant library for forward genetics in Nannochloropsis oceanica
15
作者 Zhongyi ZHANG Hang LIU +5 位作者 Xiaohui PAN Yanan ZONG Leili FENG Lixian LIU Li GUO Guanpin YANG 《Journal of Oceanology and Limnology》 SCIE CAS CSCD 2024年第1期216-225,共10页
Insertional mutation,phenotypic evaluation,and mutated gene cloning are widely used to clone genes from scratch.Exogenous genes can be integrated into the genome during non-homologous end joining(NHEJ)of the double-st... Insertional mutation,phenotypic evaluation,and mutated gene cloning are widely used to clone genes from scratch.Exogenous genes can be integrated into the genome during non-homologous end joining(NHEJ)of the double-strand breaks of DNA,causing insertional mutation.The random insertional mutant library constructed using this method has become a method of forward genetics for gene cloning.However,the establishment of a random insertional mutant library requires a high transformation efficiency of exogenous genes.Many microalgal species show a low transformation efficiency,making constructing random insertional mutant libraries difficult.In this study,we established a highly efficient transformation method for constructing a random insertional mutant library of Nannochloropsis oceanica,and tentatively tried to isolate its genes to prove the feasibility of the method.A gene that may control the growth rate and cell size was identified.This method will facilitate the genetic studies of N.oceanica,which should also be a reference for other microalgal species. 展开更多
关键词 Nannochloropsis oceanica genetic transformation random insertional mutant library zeocin pretreatment forward genetics
下载PDF
Lower extremity peripherally inserted central catheter placement ectopic to the ascending lumbar vein:A case report
16
作者 Xiao-Ju Zhu Ling Zhao +2 位作者 Na Peng Jia-Min Luo Shui-Xia Liu 《World Journal of Clinical Cases》 SCIE 2024年第8期1430-1436,共7页
BACKGROUND Peripherally inserted central catheters(PICCs)are an essential infusion route for oncology patients receiving intravenous treatments,but lower extremity veni-puncture is the preferred technique for patients... BACKGROUND Peripherally inserted central catheters(PICCs)are an essential infusion route for oncology patients receiving intravenous treatments,but lower extremity veni-puncture is the preferred technique for patients with superior vena cava syndrome(SVCS).We report the case of a patient with a lower extremity PICC ectopic to the ascending lumbar vein,to indicate and verify PICC catheterisation in the lower extremity is safe and feasible.And hope to provide different per-spectives for clinical PICC venipuncture to get the attention of peers.CASE SUMMARY On 24 August 2022,a 58-year-old male was admitted to our department due to an intermittent cough persisting for over a month,which worsened 10 d prior.Imaging and laboratory investigations suggested the patient with pulmonary malignancy and SVCS.Chemotherapy was not an absolute contraindication in this patient.Lower extremity venipuncture is the preferred technique because administering upper extremity venous transfusion to patients with SVCS can exacerbate oedema in the head,neck,and upper extremities.The patient and his family were informed about the procedure,and informed consent was obtained.After successful puncture and prompt treatment,the patient was discharged,experiencing some relief from symptoms.CONCLUSION Inferior vena cava catheterisation is rare and important for cancer patients with SVCS,particularly in complex situations involving ectopic placement. 展开更多
关键词 Superior vena cava syndrome Peripherally inserted central catheter Ascending lumbar vein COMPLICATIONS Case report
下载PDF
Treatment of benign rectal stricture caused by repeated anal insertion by endoscopy and balloon dilation:A case report
17
作者 Shih-Hung Liu Jung-Cheng Kang +3 位作者 Je-Ming Hu Chao-Yang Chen Kuan-Hsun Lin Ta-Wei Pu 《World Journal of Gastrointestinal Endoscopy》 2024年第2期91-97,共7页
BACKGROUND Benign rectal strictures can be categorized as primary(disease-related)and secondary(surgical anastomosis-related).Secondary strictures arise from surgical complications,whereas primary strictures have dive... BACKGROUND Benign rectal strictures can be categorized as primary(disease-related)and secondary(surgical anastomosis-related).Secondary strictures arise from surgical complications,whereas primary strictures have diverse etiologies,including various inflammatory conditions.Benign strictures are usually managed by surgery and endoscopy.We present an unusual etiology of benign rectal stricture caused by the repeated insertion of foreign objects into the rectum for sexual purposes,resulting in rectal injury and subsequent chronic inflammation.CASE SUMMARY A 53-year-old man presented to the outpatient clinic of the Colorectal Surgery Department with symptoms of chronic constipation and bloody stools.The patient previously experienced rectal injury due to foreign object insertion for sexual purposes.Colonoscopy revealed benign circumferential narrowing of the rectum.He underwent treatment by endoscopic argon plasma coagulation and balloon dilation and follow-up as an outpatient for 4 months.A colonoscopy at the end of the follow-up period revealed no evidence of rectal stricture relapse.CONCLUSION A history of rectal injury,followed by chronic inflammation,should be considered in patients with benign rectal strictures.Management with endoscopic argon plasma coagulation and balloon dilation can prevent the need for surgical resection of benign rectal strictures. 展开更多
关键词 Chronic rectal inflammation COLONOSCOPY Benign rectal stricture Foreign body insertion Rectal injury Case report
下载PDF
Investigation of Fracture Strength of Current Post Materials (Peek, Fiber, Cast Metal) in Different Ferrule Conditions
18
作者 Başak Topdaği Funda Bayindir 《Open Journal of Stomatology》 2024年第3期153-172,共20页
Aim: The fracture resistance of the post materials used nowadays significantly impacts the fracture type of the post material. The current study aimed to examine the impact of the fracture resistance of PEEK posts, wh... Aim: The fracture resistance of the post materials used nowadays significantly impacts the fracture type of the post material. The current study aimed to examine the impact of the fracture resistance of PEEK posts, whose use as a post material has not yet become widespread, on the fracture pattern that will occur. Materials and Methods: Sixty-six extracted upper central incisor human teeth were used in the study. Six groups of posts were produced from metal, fiber, and PEEK materials (n = 11). Afterward, the fracture resistance test was applied to the samples. Samples were classified according to fracture type as repairable or irreparable. The ANOVA and test were used in statistical analysis. Post-hoc tests were carried out using Tukey’s and Tamhane’s T2 tests. On the other hand, Pearson’s chi-square test and the Fisher-Freeman-Halton test were conducted for comparisons between categorical variables. The statistical significance level was accepted as p Results: According to the fracture resistance test results, the groups where metal personal posts were used displayed higher fracture resistance in comparison with all other groups. According to the results of the optical microscope examination, the incidence of repairable fractures was significantly higher in the PEEK post group with ferrule preparation (p 0.05). Conclusion: In the absence of the ferrule effect, fractures are catastrophic, regardless of the material used. The use of PEEK as a post material contributes to keeping fractures at a repairable level. 展开更多
关键词 Component Formatting Style STYLING INSERT
下载PDF
Natural Gas Power Plants in the System Security Role—The Situation and Solutions in Brazil
19
作者 Ciro Galvão Hirdan Katarina de Medeiros Costa +2 位作者 Eduardo Guedes Pereira Edmilson Moutinho dos Santos Dorel Soares Ramos 《Energy and Power Engineering》 2024年第4期151-178,共28页
This study aims to apply a methodology to analyze the regulatory obstacles for the development of thermal power plants in a country. The study uses Brazil as an application case, although mostly of the findings can be... This study aims to apply a methodology to analyze the regulatory obstacles for the development of thermal power plants in a country. The study uses Brazil as an application case, although mostly of the findings can be useful to other countries. It also discusses other policies and actions by the government that may contribute to the growth of natural gas-fired power plants. Using deductive and comparative research methods, the first part of this method focuses on the stage of thermoelectric power generation in Brazil. The subsequent sections present the role of the integration of gas and electricity sectors, the main obstacles to the expansion of natural-gas power generation, how the country has deal with the expansion of natural-gas power generation, as well as how other obstacles has been faced. In raising the research question, when comparing the research results of selected countries, it should be noticed the impact that the experience and lessons elsewhere have had on policies formulation on Brazil. Our conclusions pointed out that adequate policies for the natural gas-electricity Brazilian market integration make advisable the unification of electricity and natural gas agencies. We recommended developing a mathematical model to support decision-making on natural gas and electricity integration. 展开更多
关键词 Component Formatting Style STYLING INSERT
下载PDF
Current Topics in Acute Abdomen: Causes, Diagnostics, and Emerging Therapies
20
作者 Lucas de Oliveira Varca Maria Carolina de Almeida Santo 《Journal of Biosciences and Medicines》 2024年第5期171-177,共7页
Acute abdomen is a serious clinical condition that requires immediate attention due to its association with intense pain and rapid progression. This article reviews important aspects of the causes, diagnostics, and tr... Acute abdomen is a serious clinical condition that requires immediate attention due to its association with intense pain and rapid progression. This article reviews important aspects of the causes, diagnostics, and treatments of acute abdomen. The research highlights the diversity of etiologies, ranging from the most common, such as acute appendicitis, to the less frequent, such as intestinal perforations by foreign bodies. Complex diagnostic methods, including clinical examinations and imaging such as computed tomography, are essential to guide accurate diagnosis, given the overlap of symptoms among different conditions. Therapeutic approaches range from conservative treatments with clinical observation and antibiotic therapy to urgent surgical interventions, such as appendectomy and cholecystectomy. Laparoscopy stands out as a promising approach, offering advantages in terms of recovery and post-operative morbidity. However, the impact of the COVID-19 pandemic has brought additional challenges to the diagnosis and treatment of acute abdomen, with delays and difficulties in accessing healthcare. This review underscores the importance of a multidisciplinary approach and constant updates among healthcare professionals in addressing acute abdomen, aiming for accurate diagnoses and appropriate therapeutic interventions to improve clinical outcomes and reduce morbidity and mortality associated with this complex clinical condition. 展开更多
关键词 COMPONENT Formatting Style STYLING INSERT
下载PDF
上一页 1 2 33 下一页 到第
使用帮助 返回顶部