Variable IP method mainly measures the Percent Frequency Effect (PFE), and phase IP method mainly measures phase. They both aim at finding IP anomaly. However, only using PFE anomaly or single phase anomaly can′t dis...Variable IP method mainly measures the Percent Frequency Effect (PFE), and phase IP method mainly measures phase. They both aim at finding IP anomaly. However, only using PFE anomaly or single phase anomaly can′t distinguish IP body′s property. The authors put forward a new method——dualfrequency and multiparameter IP method, which can not only find anomaly of PFE and phase, but also provide the property information of IP anomaly resource. The authors also have invented the dualfrequency and multiparameter IP instrument. A lot of experiments and field work have been done. The results show that the instrument is valuable in distinguishing IP anomalies.展开更多
Non-iterative analysis of indentation results allows for the detection of phase transitions under load and their transition energy. The closed algebraic equations have been deduced on the basis of the physically found...Non-iterative analysis of indentation results allows for the detection of phase transitions under load and their transition energy. The closed algebraic equations have been deduced on the basis of the physically founded normal force ?depth3/2 relation. The precise transition onset position is obtained by linear regression of the FN = kh3/2 plot, where k is the penetration resistance, which also provides the axis cuts of both polymorphs of first order phase transitions. The phase changes can be endothermic or exothermic. They are normalized per μN or mN normal load. The analyses of indentation loading curves with self-similar diamond indenters are used as validity check of the loading curves, also from calibration standards that exhibit previously undetected phase-transitions and are thus incorrect. The phase-transition energies for fused quartz are determined from the loading curves from instrument provider handbooks. The anisotropic behavior of phase transition energies is studied for the first time. Quartz is a useful test object. The reasons for the packing-dependent differences are discussed on the basis of the local crystal structure under and around the inserting tip.展开更多
A new method for array calibration of array gain and phase uncertainties, which severely degrade the performance of spatial spectrum estimation, is presented. The method is based on the idea of the instrumental sensor...A new method for array calibration of array gain and phase uncertainties, which severely degrade the performance of spatial spectrum estimation, is presented. The method is based on the idea of the instrumental sensors method (ISM), two well-calibrated sensors are added into the original array. By applying the principle of estimation of signal parameters via rotational invariance techniques (ESPRIT), the direction-of-arrivals (DOAs) and uncertainties can be estimated simultaneously through eigen-decomposition. Compared with the conventional ones, this new method has less computational complexity while has higher estimation precision, what's more, it can overcome the problem of ambiguity. Both theoretical analysis and computer simulations show the effectiveness of the proposed method.展开更多
文摘Variable IP method mainly measures the Percent Frequency Effect (PFE), and phase IP method mainly measures phase. They both aim at finding IP anomaly. However, only using PFE anomaly or single phase anomaly can′t distinguish IP body′s property. The authors put forward a new method——dualfrequency and multiparameter IP method, which can not only find anomaly of PFE and phase, but also provide the property information of IP anomaly resource. The authors also have invented the dualfrequency and multiparameter IP instrument. A lot of experiments and field work have been done. The results show that the instrument is valuable in distinguishing IP anomalies.
文摘Non-iterative analysis of indentation results allows for the detection of phase transitions under load and their transition energy. The closed algebraic equations have been deduced on the basis of the physically founded normal force ?depth3/2 relation. The precise transition onset position is obtained by linear regression of the FN = kh3/2 plot, where k is the penetration resistance, which also provides the axis cuts of both polymorphs of first order phase transitions. The phase changes can be endothermic or exothermic. They are normalized per μN or mN normal load. The analyses of indentation loading curves with self-similar diamond indenters are used as validity check of the loading curves, also from calibration standards that exhibit previously undetected phase-transitions and are thus incorrect. The phase-transition energies for fused quartz are determined from the loading curves from instrument provider handbooks. The anisotropic behavior of phase transition energies is studied for the first time. Quartz is a useful test object. The reasons for the packing-dependent differences are discussed on the basis of the local crystal structure under and around the inserting tip.
文摘A new method for array calibration of array gain and phase uncertainties, which severely degrade the performance of spatial spectrum estimation, is presented. The method is based on the idea of the instrumental sensors method (ISM), two well-calibrated sensors are added into the original array. By applying the principle of estimation of signal parameters via rotational invariance techniques (ESPRIT), the direction-of-arrivals (DOAs) and uncertainties can be estimated simultaneously through eigen-decomposition. Compared with the conventional ones, this new method has less computational complexity while has higher estimation precision, what's more, it can overcome the problem of ambiguity. Both theoretical analysis and computer simulations show the effectiveness of the proposed method.