期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
NOVEL DESIGN OF A BIOELECTRIC AMPLIFIER WITH MINIMIZED MAGNITUDE AND PHASE ERRORS 被引量:1
1
作者 Mashhour Bani Amer Assistant Professor 《Journal of Electronics(China)》 2001年第3期242-254,共13页
A new design of a bioelectric amplifier that has better parameters than conventional designs is presented. The design allows the construction of bioelectric amplifier with improved parameters in terms of common-mode r... A new design of a bioelectric amplifier that has better parameters than conventional designs is presented. The design allows the construction of bioelectric amplifier with improved parameters in terms of common-mode rejection ratio and phase and magnitude errors. The voltage gain is easily adapted to a wide range of biomedical applications. The experimental and simulation results of the designed bioelectric amplifier are also included. 展开更多
关键词 Bioelectric amplifier instrumentation amplifier common-mode rejection ratio
下载PDF
测量放大器共模抑制能力的分析 被引量:6
2
作者 郭兴昕 赵进全 《中国仪器仪表》 2005年第9期68-68,70,共2页
测量放大器具有很强的抑制共模信号的能力,但由于电路的分析过程非常复杂,通常只在电路理想情况下,给出电路的差模增益。本文在电路非理想的情况下,分析了测量放大器抑制共模信号的机理,给出了放大器的差模、共模增益以及共模抑制比表... 测量放大器具有很强的抑制共模信号的能力,但由于电路的分析过程非常复杂,通常只在电路理想情况下,给出电路的差模增益。本文在电路非理想的情况下,分析了测量放大器抑制共模信号的机理,给出了放大器的差模、共模增益以及共模抑制比表达式。结论对测量放大器的设计和应用具有一定的指导意义。 展开更多
关键词 测量放大器 非理想电路 共模抑制比 共模信号 抑制能力 差模增益 非理想 电路 表达式
下载PDF