Objective To investigate the process and mechanism of insulator surface charge accumulation under impulse voltage, a dynamic equation was established for describing the relationship between surface charge density and ...Objective To investigate the process and mechanism of insulator surface charge accumulation under impulse voltage, a dynamic equation was established for describing the relationship between surface charge density and applied voltage. Results The established equation is more generalized in comparison with that given by other previous investigators. Constants A, B for typical electrodes used in the present equation are specified. The process and mechanism of surface charge accumulation under impulse voltage are studied and the factors that influence surface charge accumulation discussed. Conclusion The present theoretical studies help to explain why surface charging can be accomplished instantly under impulse voltage, and determine the factors influencing surface charge accumulation. The findings confirmed some surface charging phenomena observed in GIS by some previous investigators.展开更多
In an insulating system including solid and gas dielectrics, discharge type has a strong impact on charge accumulation at the interface between two dielectrics, and hence charge decay. In order to clarify the influenc...In an insulating system including solid and gas dielectrics, discharge type has a strong impact on charge accumulation at the interface between two dielectrics, and hence charge decay. In order to clarify the influence, a surface charge measurement system was constructed, and three types of discharge, i.e. surface discharge, and low intensity and high intensity coronas, were introduced to cause surface charge accumulation. The decay behavior of surface charges after different types of discharge was obtained at various temperatures. It was found that total surface charges monotonically decreased with time, and the decay rate became larger as temperature increased. However, after a surface discharge or a high intensity corona, surface charge density in the local area appeared to fluctuate during the decay process. Compared with this, the fluctuation of surface charge density was not observed after a low intensity corona. The mechanisms of surface charge accumulation and decay were analysed. Moreover, a microscopic physical model involving charge production, accumulation, and decay was proposed so that the experimental results could be explained.展开更多
Surface charge accumulation is considered to be a critical factor in flashover failure of three-post insulators.However,surface charge accumulation characteristics on threepost insulators with complex structures and u...Surface charge accumulation is considered to be a critical factor in flashover failure of three-post insulators.However,surface charge accumulation characteristics on threepost insulators with complex structures and uneven electric fields are still unclear.Furthermore,the temperature gradient field makes charge accumulation more complicated.In this presentation,surface charge profiles of DC three-post insulators under electro-thermal coupling stress are studied by establishing a multi-degree-of-freedom movement measurement system.The abdominal area of the three-post insulator accumulaftes charges of identical polarity as the DC voltage,while the leg area accumulates heteropolar charges.Charge density from the bottom of the leg to the center of the abdomen presents a trimodal distribution pattern,including two homopolar charge peaks and one heteropolar charge peak.Asymmetrical surface conductance distribution arising from the temperature gradient leads to a significant increase in amplitude and distribution range of the homopolar charge peak at the legs of insulator.Increase of the temperature gradient will further magnify the homopolar charge peak at the legs.When DC voltage is 100 kV and conductive pole temperature is 70℃,surface charge density of the three-post insulator can reach 100μC/m^(2).Therefore,surface conductance regulation of the leg region is the key to charge regulation and insulation optimization design of DC three-post insulators.展开更多
Gas insulator switchgears(GISs),widely used in electric power systems for decades,have many advantages due to their compactness,minimal environmental impact,and long maintenance cycles.However,very fast transient over...Gas insulator switchgears(GISs),widely used in electric power systems for decades,have many advantages due to their compactness,minimal environmental impact,and long maintenance cycles.However,very fast transient overvoltage(VFTO)increases caused by a rise in voltage levels can lead to GIS insulation failures.In this paper,a generating system of VFTO and standard lightning impulse(LI)is established.The insulation characteristics of SF6 gas with and without insulators under VFTO and standard LI are investigated.Experimental results show that the 50%breakdown voltages of the inhomogeneous electric field rod-plane gap under positive VFTO and standard LI are higher than that under negative VFTO and standard LI.The research shows that the 50%breakdown voltage under VFTO could be lower than that under standard LI at 0.5 MPa for the negative polarity.Moreover,the polarity effect of the insulator without defect is different from that with defect.Similarly,the breakdown voltage of the defective insulator under VFTO could be lower than that under standard LI by 8%.The flashover channel under VFTO is seen as more than that under standard LI.Based on the analysis of discharge images and experimental results,it is concluded that the polarity effect is related to the distortion effect of ion clusters formed by SF6 on the electric field.Additionally,the steepness and front time of impulse plays an important role in the initiation and further development of discharge on insulator surface.Finally,the research shows that different discharge characteristics between VFTO and standard LI may be caused by different wave fronts and oscillation on the tails of the impulses.展开更多
Surface flashover of spacers is a key factor limiting the application of HVDC GIS/GIL,while the charge accumula-tion on the surface of the spacer could have a potential adverse effect on the surface flashover voltage....Surface flashover of spacers is a key factor limiting the application of HVDC GIS/GIL,while the charge accumula-tion on the surface of the spacer could have a potential adverse effect on the surface flashover voltage.This paper discusses the laws regarding distribution patterns of surface charges and the related mechanisms.The field-dependent property is discussed in detail to comprehensively illustrate the charge transport mecha-nism and explain the research differences regarding different surface charge patterns obtained by previous researchers.In addition,the main surface charge control methods for epoxy resin are summarized and discussed.The potential research directions of charge control methods and key points in manufacturing of spacers used in HVDC GIS/GIL are also explored.展开更多
基金ThisresearchwassupportedbyMinistryofEducationforaDoctoralProgram (No .2 0 0 1 0 6980 1 4)
文摘Objective To investigate the process and mechanism of insulator surface charge accumulation under impulse voltage, a dynamic equation was established for describing the relationship between surface charge density and applied voltage. Results The established equation is more generalized in comparison with that given by other previous investigators. Constants A, B for typical electrodes used in the present equation are specified. The process and mechanism of surface charge accumulation under impulse voltage are studied and the factors that influence surface charge accumulation discussed. Conclusion The present theoretical studies help to explain why surface charging can be accomplished instantly under impulse voltage, and determine the factors influencing surface charge accumulation. The findings confirmed some surface charging phenomena observed in GIS by some previous investigators.
基金the financial support from National Natural Science Foundation of China (No. 51607128)Natural Science Foundation of Hubei Province (No. 2016CFB111)China Postdoctoral Science Foundation (No. 2016M602353)
文摘In an insulating system including solid and gas dielectrics, discharge type has a strong impact on charge accumulation at the interface between two dielectrics, and hence charge decay. In order to clarify the influence, a surface charge measurement system was constructed, and three types of discharge, i.e. surface discharge, and low intensity and high intensity coronas, were introduced to cause surface charge accumulation. The decay behavior of surface charges after different types of discharge was obtained at various temperatures. It was found that total surface charges monotonically decreased with time, and the decay rate became larger as temperature increased. However, after a surface discharge or a high intensity corona, surface charge density in the local area appeared to fluctuate during the decay process. Compared with this, the fluctuation of surface charge density was not observed after a low intensity corona. The mechanisms of surface charge accumulation and decay were analysed. Moreover, a microscopic physical model involving charge production, accumulation, and decay was proposed so that the experimental results could be explained.
基金supported by the National Natural Science Foundation of China(51737005,52127812,51929701).
文摘Surface charge accumulation is considered to be a critical factor in flashover failure of three-post insulators.However,surface charge accumulation characteristics on threepost insulators with complex structures and uneven electric fields are still unclear.Furthermore,the temperature gradient field makes charge accumulation more complicated.In this presentation,surface charge profiles of DC three-post insulators under electro-thermal coupling stress are studied by establishing a multi-degree-of-freedom movement measurement system.The abdominal area of the three-post insulator accumulaftes charges of identical polarity as the DC voltage,while the leg area accumulates heteropolar charges.Charge density from the bottom of the leg to the center of the abdomen presents a trimodal distribution pattern,including two homopolar charge peaks and one heteropolar charge peak.Asymmetrical surface conductance distribution arising from the temperature gradient leads to a significant increase in amplitude and distribution range of the homopolar charge peak at the legs of insulator.Increase of the temperature gradient will further magnify the homopolar charge peak at the legs.When DC voltage is 100 kV and conductive pole temperature is 70℃,surface charge density of the three-post insulator can reach 100μC/m^(2).Therefore,surface conductance regulation of the leg region is the key to charge regulation and insulation optimization design of DC three-post insulators.
基金supported by National Basic Research Program of China(973 Program)and Science and Technology Project of SGCC“Research on the Application of VFTO Key Techniques in Ultra High GIS Substation”(GYB17201400111).
文摘Gas insulator switchgears(GISs),widely used in electric power systems for decades,have many advantages due to their compactness,minimal environmental impact,and long maintenance cycles.However,very fast transient overvoltage(VFTO)increases caused by a rise in voltage levels can lead to GIS insulation failures.In this paper,a generating system of VFTO and standard lightning impulse(LI)is established.The insulation characteristics of SF6 gas with and without insulators under VFTO and standard LI are investigated.Experimental results show that the 50%breakdown voltages of the inhomogeneous electric field rod-plane gap under positive VFTO and standard LI are higher than that under negative VFTO and standard LI.The research shows that the 50%breakdown voltage under VFTO could be lower than that under standard LI at 0.5 MPa for the negative polarity.Moreover,the polarity effect of the insulator without defect is different from that with defect.Similarly,the breakdown voltage of the defective insulator under VFTO could be lower than that under standard LI by 8%.The flashover channel under VFTO is seen as more than that under standard LI.Based on the analysis of discharge images and experimental results,it is concluded that the polarity effect is related to the distortion effect of ion clusters formed by SF6 on the electric field.Additionally,the steepness and front time of impulse plays an important role in the initiation and further development of discharge on insulator surface.Finally,the research shows that different discharge characteristics between VFTO and standard LI may be caused by different wave fronts and oscillation on the tails of the impulses.
基金This study is financially supported by the National Basic Research Program(2017YFB0903800)and the Electric Power Research Institute,Yunnan Electric Power Grid Co.Ltd,Kunming,Yunnan 650217,China(YNKJXM20160146).
文摘Surface flashover of spacers is a key factor limiting the application of HVDC GIS/GIL,while the charge accumula-tion on the surface of the spacer could have a potential adverse effect on the surface flashover voltage.This paper discusses the laws regarding distribution patterns of surface charges and the related mechanisms.The field-dependent property is discussed in detail to comprehensively illustrate the charge transport mecha-nism and explain the research differences regarding different surface charge patterns obtained by previous researchers.In addition,the main surface charge control methods for epoxy resin are summarized and discussed.The potential research directions of charge control methods and key points in manufacturing of spacers used in HVDC GIS/GIL are also explored.