This paper demonstrates the intensity modulation characters of orthogonally polarized HeNe lasers with different optical feedback level generated by the variable reflectivity of external reflector. The modulation dept...This paper demonstrates the intensity modulation characters of orthogonally polarized HeNe lasers with different optical feedback level generated by the variable reflectivity of external reflector. The modulation depths of the orthogonally polarized frequencies are increased when the optical feedback level becomes strong. It also observes that the modulation amplitudes are different for different external cavity length. Based on the vectorial extension of Lamb's semi-classical theory, it finds that the calculations are consistent with the experimental results.展开更多
We present how residual intensity modulation(RIM) affects the performance of a resonator fiber optic gyro(R-FOG) through a sinusoidal wave phase modulation technique. The expression for the R-FOG system's demodula...We present how residual intensity modulation(RIM) affects the performance of a resonator fiber optic gyro(R-FOG) through a sinusoidal wave phase modulation technique. The expression for the R-FOG system's demodulation curve under RIM is obtained. Through numerical simulation with different RIM coefficients and modulation frequencies, we find that a zero deviation is induced by the RIM effect on the demodulation curve, and this zero deviation varies with the RIM coefficient and modulation frequency. The expression for the system error due to this zero deviation is derived. Simulation results show that the RIM-induced error varies with the RIM coefficient and modulation frequency. There also exists optimum values for the RIM coefficient and modulation frequency to totally eliminate the RIM-induced error, and the error increases as the RIM coefficient or modulation frequency deviates from its optimum value; however, in practical situations, these two parameters would not be exactly fixed but fluctuate from their respective optimum values, and a large system error is induced even if there exists a very small deviation of these two critical parameters from their optimum values. Simulation results indicate that the RIM-induced error should be considered when designing and evaluating an R-FOG system.展开更多
The characteristics of a conventional LiNbO3 intensity modulator made up of a Mach-Zehnder(MZ) type annealed proton exchange(APE) waveguide and coplanar waveguide(CPW) modulation electrode are presented. The APE waveg...The characteristics of a conventional LiNbO3 intensity modulator made up of a Mach-Zehnder(MZ) type annealed proton exchange(APE) waveguide and coplanar waveguide(CPW) modulation electrode are presented. The APE waveguide characteristics and their relations with process parameters are analyzed. At the same time, the electrical characteristics of modulation electrode, such as modulation voltage, microwave effective index associated with modulation bandwidth, characteristics impedance, are also investigated in detail.展开更多
The modulation depth, defined according to practical modulation results, which changes with the microwave power and its frequency, is significant for systems utilizing the frequency-shift characteristic of the LiNbO3 ...The modulation depth, defined according to practical modulation results, which changes with the microwave power and its frequency, is significant for systems utilizing the frequency-shift characteristic of the LiNbO3 waveguide Electro-Optic Intensity Modulator (EOIM). By analyzing the impedance mismatch between the microwave source and the EOIM, the effective voltage applied to the RF port of the EOIM is deprived from the microwave power and its frequency. Associating with analyses of the phase velocity mismatch between the microwave and the optical wave, the theoretical modulation depth has been obtained, which is verified by experimental results. We provide a method to choose the appropriate modulation depth to optimize the desired sideband through proper transmission bias for the system based on the frequency-shift characteristic of the EOIM.展开更多
Modulation techniques for light fidelity (Li-Fi) are reviewed in this paper. Li-Fi is the fully networked solution for nmltiple users that combines communication and illumination simultaneously. Light emitting diod...Modulation techniques for light fidelity (Li-Fi) are reviewed in this paper. Li-Fi is the fully networked solution for nmltiple users that combines communication and illumination simultaneously. Light emitting diodes (LEDs) are used in Li-Fi as visible light transmitters, therefore, only intensity modulated direct detected modulation techniques can be achieved. Single carrier modulation techniques are straightforward to be used in Li-Fi, however, computationally complex equalization processes are required in fre- quency selective Li-Fi channels. On the other hand, multiearrier modulation techniques offer a viable solution for Li-Fi in terms of power, spectral and computational efficiency. In particular, orthogonal frequency division multiplexing (OFDM) based modulation techniques offer a practical solution for Li-Fi, especially when direct current (DC) wander, and adaptive bit and power loading techniques are considered. Li-Fi modulation techniques need to also satisfy illumination requirements. Flickering avoidance and dimming control are considered in the variant modulation techniques presented. This paper surveys the suitable modulation techniques for Li-Fi including those which explore time, frequency and colour domains.展开更多
An analytic equation interpreting the intensity of ultrasound-modulated scattering light is derived, based on diffusion theory and previous explanations of the intensity modulation mechanism. Furthermore, an experimen...An analytic equation interpreting the intensity of ultrasound-modulated scattering light is derived, based on diffusion theory and previous explanations of the intensity modulation mechanism. Furthermore, an experiment of ultrasonic modulation of incoherent light in a scattering medium is developed. This analytical model agrees well with experimental results,which confirms the validity of the proposed intensity modulation mechanism. The model supplements the existing research on the ultrasonic modulation mechanism of scattering light.展开更多
BACKGROUND Primary liver cancer is a malignant tumor with a high recurrence rate that significantly affects patient prognosis.Postoperative adjuvant external radiation therapy(RT)has been shown to effectively prevent ...BACKGROUND Primary liver cancer is a malignant tumor with a high recurrence rate that significantly affects patient prognosis.Postoperative adjuvant external radiation therapy(RT)has been shown to effectively prevent recurrence after liver cancer resection.However,there are multiple RT techniques available,and the differ-ential effects of these techniques in preventing postoperative liver cancer re-currence require further investigation.AIM To assess the advantages and disadvantages of various adjuvant external RT methods after liver resection based on overall survival(OS)and disease-free survival(DFS)and to determine the optimal strategy.METHODS This study involved network meta-analyses and followed the PRISMA guidelines.The data of qualified studies published before July 10,2023,were collected from PubMed,Embase,the Web of Science,and the Cochrane Library.We included relevant studies on postoperative external beam RT after liver resection that had OS and DFS as the primary endpoints.The magnitudes of the effects were determined using risk ratios with 95%confidential intervals.The results were analyzed using R software and STATA software.RESULTS A total of 12 studies,including 1265 patients with hepatocellular carcinoma(HCC)after liver resection,were included in this study.There was no significant heterogeneity in the direct paired comparisons,and there were no significant differences in the inclusion or exclusion criteria,intervention measures,or outcome indicators,meeting the assumptions of heterogeneity and transitivity.OS analysis revealed that patients who underwent stereotactic body radiotherapy(SBRT)after resection had longer OS than those who underwent intensity modulated radiotherapy(IMRT)or 3-dimensional conformal RT(3D-CRT).DFS analysis revealed that patients who underwent 3D-CRT after resection had the longest DFS.Patients who underwent IMRT after resection had longer OS than those who underwent 3D-CRT and longer DFS than those who underwent SBRT.CONCLUSION HCC patients who undergo liver cancer resection must consider distinct advantages and disadvantages when choosing between SBRT and 3D-CRT.IMRT,a RT technique that is associated with longer OS than 3D-CRT and longer DFS than SBRT,may be a preferred option.展开更多
Subcarrier intensity modulation with direet detection is a modulatiou/detection technique tbr optical wireless communication systems, where a pre-modulated and properly biased radio frequency signal is modulated on th...Subcarrier intensity modulation with direet detection is a modulatiou/detection technique tbr optical wireless communication systems, where a pre-modulated and properly biased radio frequency signal is modulated on the intensity of the optical carrier. The most important benefits of subcarrier intensity modulation are as follows: 1) it does not provide irreducible error floor like the conventional on-off keying intensity modulation with a fixed detection threshold; 2) it provides improved spectral efficiency and supports higher order modulation schemes; and 3) it has much less implementation complexity compared to coherent optical wireless communications with heterodyne or homodyne detection. In this paper, we present an up-to-date review of subcarrier intensity modulated optical wireless communication systems. We survey the error rate and outage performance of subcarrier intensity modulations in the atmospheric turbulence channels considering different modulation and coding schemes. We also explore different contemporary atmospheric turbulence fading mitigation solutions that can be employed for subcarrier intensity modulation. These solutions include diversity combining, adaptive transmission, relay assisted transmission, multiple-subcarrier intensity modulations, and optical orthogonal frequency division multiplexing. Moreover, we review the performance of subcarrier intensity modulations due to the pointing error and synchronization error.展开更多
High-speed and wide-band LiNbO3 waveguide electro-optic intensity modulator has drawn great attention in the field of optical fiber communication and sensor. This paper reports the research results on the measurement ...High-speed and wide-band LiNbO3 waveguide electro-optic intensity modulator has drawn great attention in the field of optical fiber communication and sensor. This paper reports the research results on the measurement of frequency shift characteristics of Mach-Zehnder electro-optic intensity modulator. Two measurement methods of frequency shift characteristics for high and low frequency modulations are studied in theory and experiment and demonstrate different results. The realization of a multi-wavelength optical source based on Mach-Zehnder electro-optic intensity modulator has been introduced. The technique to reach the maximum intensity for interesting shift frequency, particularly for heterodyne detection of Brillouin distributed optical fiber sensing, has been given.展开更多
We propose a novel light intensity modulator based on magnetic fluid and liquid crystal(LC) filled photonic crystal fibers(PCFs). The influences of electric and magnetic fields on the transmission intensity are th...We propose a novel light intensity modulator based on magnetic fluid and liquid crystal(LC) filled photonic crystal fibers(PCFs). The influences of electric and magnetic fields on the transmission intensity are theoretically and experimentally analyzed and investigated. Both the electric and magnetic fields can manipulate the molecular arrangement of LC to array a certain angle without changing the refractive index of the LC. Therefore, light loss in the PCF varies with the electric and magnetic fields whereas the peak wavelengths remain constant. The experimental results show that the transmission intensity decreases with the increase of the electric and magnetic fields. The cut-off electric field is 0.899 V/um at 20 Hz and the cut-off magnetic field is 195 m T. This simple and compacted optical modulator will have a great prospect in sensing applications.展开更多
Objective:Serum prostate specific antigen(PSA)is commonly used to evaluate treatment response after definitive radiation therapy(RT).However,PSA levels can temporarily rise without a clear reason,termed“PSA bounce”,...Objective:Serum prostate specific antigen(PSA)is commonly used to evaluate treatment response after definitive radiation therapy(RT).However,PSA levels can temporarily rise without a clear reason,termed“PSA bounce”,and often engender great anxiety for both patients and physicians.The present study aimed to determine the prevalence and factors that predict“PSA bounce”after intensity-modulated radiation therapy(IMRT),and the relevance to biochemical failure and cancer recurrence in an Asian population.Methods:We retrospectively reviewed 206 patients who received IMRT for prostate cancer from 2004 to 2012 in the National Cancer Centre Singapore.These patients were followed up with regular PSA monitoring.We defined“PSA bounce”as a rise of 0.1 ng/mL,followed by two consecutive falls.Patients with biochemical failure(PSA nadir t 2 ng/mL)were further evaluated for cancer recurrence.Results:Sixty-one patients(29.6%)experienced“PSA bounce”,at a median time of 16 months and lasted for 12 months.Age remained the most consistent predictor of the incidence,duration and extent of“PSA bounce”.Other contributory factors included baseline PSA,Gleason score and PSA nadir.Hormonal therapy and prostate volume did not affect this phenomenon.Sixteen patients(7.8%)developed biochemical recurrence,at median time of 32 months,of which 11 were confirmed to have metastatic disease.The median follow-up time was 71 months.展开更多
Objective: To evaluate the clinical effects of concurrent and sequential therapy for middle and advanced stage non-small cell lung cancer (NSCLC) useing IMRT combined with NP regimen chemotherapy. Methods: Eighty pati...Objective: To evaluate the clinical effects of concurrent and sequential therapy for middle and advanced stage non-small cell lung cancer (NSCLC) useing IMRT combined with NP regimen chemotherapy. Methods: Eighty patients with middle and advanced stage NSCLC were randomized into two groups. Forty patients were underwent sequential therapy and other 40 patients were underwent concurrent therapy. IMRT was used in radiotherapy and NP regimen of vinorelbine+cispatin (NP) was used in chemotherapy. Results: (1) The overall response (CR+PR) rate was 75% in concurrent group and 45% in sequential group (P<0.05); (2) The treatment courses were 84 days and 140 days for concurrent group and sequential group respectively (P<0.05); (3) One-year survival rate in concurrent group was 72.4% and 52.3% in sequential group respectively; (4) The toxic effects can be tolerable by all of patients. Conclusion: The concurrent chemo-radiotherapy has better overall re- sponse, one-year survival rate and shorter treatment course than the sequential chemo-radiotherapy, so it is a better method for the treatment of middle and advanced stage NSCLC, but the long term survival rate will be studied.展开更多
Objective: The purpose of this study was to investigate the impact of intensity modulated radiotherapy (IMRT) on surface doses for brain, abdomen and pelvis deep located tumors treated with 6 MV photon and to evaluate...Objective: The purpose of this study was to investigate the impact of intensity modulated radiotherapy (IMRT) on surface doses for brain, abdomen and pelvis deep located tumors treated with 6 MV photon and to evaluate the skin dose calculation accuracy of the XIO 4.04 treatment planning system. Methods: More investigations for the influences of IMRT on skin doses would increase its applications for many treatment sites. Measuring skin doses in real treatment situations would reduce the uncertainty of skin dose prediction. In this work a pediatric human phantom was covered by a layer of 1 mm bolus at three treatment sites and thermoluminescent dosimeter (TLD) chips were inserted into the bolus at each treatment site before CT scan. Two different treatment plans [three-dimensional conformal radiation therapy (3DCRT) and IMRT] for each treatment sites were performed on XIO 4.04 treatment planning system using superposition algorism. Results: The results showed that the surface doses for 3DCRT were higher than the surface doses in IMRT by 1.6%, 2.5% and 3.2% for brain, abdomen and pelvis sites respectively. There was good agreement between measured and calculated surface doses, where the calculated surface dose was 15.5% for brain tumor calculated with 3DCRT whereas the measured surface dose was 12.1%. For abdomen site the calculated surface dose for IMRT treatment plan was 16.5% whereas the measured surface dose was 12.6%. Conclusion: The skin dose in IMRT for deep seated tumors is lower than that in 3DCRT which is another advantage for the IMRT. The TLD readings showed that the difference between the calculated and measured point dose is negligible. The superposition calculation algorism of the XIO 4.04 treatment planning system modeled the superficial dose well.展开更多
Objective:This study was to compare 5 field conformal technique to the intensity modulated radiotherapy (IMRT) 8 fields technique in boosting locally advanced cancer cervix cases after external beam radiotherapy with ...Objective:This study was to compare 5 field conformal technique to the intensity modulated radiotherapy (IMRT) 8 fields technique in boosting locally advanced cancer cervix cases after external beam radiotherapy with respect to target volume coverage and dose to normal tissues. Methods:We conducted a single institutional comparative dosimetric analysis of 10 patients with cancer cervix who was presented to radiotherapy department in National Cancer Institute, Cairo in period between June 2012 to September 2012 and received a CRT boost in the place of planned brachytherapy after large field pelvic radiotherapy (PRT) with concurrent chemotherapy were retrospectively identified. All tumors were situated in the low central pelvis. Two plans were done for every patient; one using the 8 fields IMRT and the second one using 5 fields' 3DCRT the two techniques were then compared using dose volume histogram (DVH) analysis for the PTV, bladder, rectum and both femoral heads. Results:Comparing different DVHs, it was found that the planning target volume (PTV) was adequately covered in both plans while it was demonstrates that the 8 fields IMRT technique carried less doses reaching OARs (rectum, bladder, both femoral heads). Conclusion:From the present study, it is concluded that IMRT technique spared more efficiently OARs than CRT technique but both techniques covered the PTV adequately so whenever possible IMRT technique should be used.展开更多
Optical fibre sensor has the advantages of small size,light weight,anti⁃electromagnetic interference,and high measurement accuracy,which has important applications in research and industrial production.To design an op...Optical fibre sensor has the advantages of small size,light weight,anti⁃electromagnetic interference,and high measurement accuracy,which has important applications in research and industrial production.To design an optical fibre displacement sensor(OFBDS)with simple structure and high measurement accuracy,the unified model of the commonly used OFBDS structures was proposed and the feasibility of the intensity⁃modulation of multi⁃structural optical fibre bundles was analysed based on the arrangement characteristics of the fibre bundle end⁃face.The intensity⁃modulation characteristic of different fibre bundles was analysed,and the single coil coaxial fibre bundle was chosen as the fibre probe in this study.The sensor hardware system was designed.Lastly,the calibration experiment,temperature interference experiment,changes of measured plane surface area,and the dynamic experiment were conducted.Results showed that the sensor linear measurement range was about 3 mm,and the sensor system had excellent static and dynamic characteristics.展开更多
Patients with recurrent breast cancer to chest wall, who had previous irradiation, are difficult to manage and have limited options. Several reports described the use of photon therapy, hyperthermia, and brachytherapy...Patients with recurrent breast cancer to chest wall, who had previous irradiation, are difficult to manage and have limited options. Several reports described the use of photon therapy, hyperthermia, and brachytherapy. This is a case report of a 72-year-old female with Stage IIIA (pT3N1M0) invasive ductal carcinoma of the right breast status post modified radical mastectomy. The patient developed recurrence to the chest wall and one internal mammary lymph node one year later. She received 3-D conformal photon radiation therapy for this recurrence. Two years later, she had progression of the recurrence at the right chest wall and axillary and internal mammary lymph nodes. She was treated with intensity modulated proton therapy (IMPT) for a total of 6600 cGy in 33 fractions. However, four months later, she was found to have biopsy-proven isolated metastatic disease at her right bicep, which was again treated with IMPT for a dose of 6000 cGy in 20 fractions. Proton beam therapy was used in this case to spare dose to the brachial plexus, heart and lung while optimally irradiating the recurrent tumors. At last follow up, the patient is alive and has been disease free for 39 months. This report describes the technique and dosimetry for this unique case, which also reviewed recent series of re-irradiation using proton beam.展开更多
Introduction: Nasopharyngeal carcinomas are the most radiation-sensitive tumours, and radiotherapy alone provides better local control. Objectives: To evaluate the clinical efficacy and acute and late toxicities of tw...Introduction: Nasopharyngeal carcinomas are the most radiation-sensitive tumours, and radiotherapy alone provides better local control. Objectives: To evaluate the clinical efficacy and acute and late toxicities of two different treatment regimens for locally advanced nasopharyngeal carcinoma. Methods: From 2014 to 2017, 150 cases of stage III and 68 cases of stage IVA nasopharyngeal carcinoma were treated. Of these, 137 received conventional radiotherapy plus chemotherapy, and 81 received intensity-modulated radiotherapy plus chemotherapy. Chemotherapy was given either as induction, concurrent or adjuvant therapy. Survival rates were calculated according to Kaplan Meier and compared with the Log-rank test. The RTOG or EORTC criteria were used to assess acute and late toxicities. Results: The median follow-up time was 21.5 months, and the 2-year locoregional relapse-free survival, distant metastases-free survival, and overall survival rates in the conventional radiotherapy plus chemotherapy group were 76%, 71% and 77%, respectively;in the intensity-modulated radiotherapy plus chemotherapy group, they were 97%, 84%, and 100%, respectively. The difference in survival between the two groups was significant (χ<sup>2</sup> = 5.06, P = 0.028). The incidence of grade 2 and 3 xerostomia one year after radiotherapy was 45.1% and 30.9% versus 33.3% and 0%. Conclusion: Compared with conventional radiotherapy plus chemotherapy, intensity-modulated radiotherapy plus chemotherapy offers better locoregional relapse-free survival and overall survival in patients with stage III and IVA nasopharyngeal carcinoma, and may significantly reduce the occurrence of radiation-induced xerostomia.展开更多
The mode hopping phenomenon induced by optical feedback in single-mode microchip Nd:YAG lasers is presented. With optical feedback, mode hopping strongly depends on two factors: the ratio of external cavity length t...The mode hopping phenomenon induced by optical feedback in single-mode microchip Nd:YAG lasers is presented. With optical feedback, mode hopping strongly depends on two factors: the ratio of external cavity length to intra-cavity length, and initial gains of the two hopping modes, When external cavity length equals an integral multiple of intracavity length, there is almost no mode hopping. However, if the external cavity length does not equal an integral multiple of intra-cavity length, mode hopping occurs. The ratio of external cavity length to intra-cavity length determines the position of two-mode hopping, The initial gains of the two hopping modes determine the corresponding peak values and oscillating periods of them in the intensity modulation curves.展开更多
Strong optical feedback in a birefringent dual frequency He-Ne laser with a high reflectivity feedback mirror has been investigated for the first time. The output characteristics of two orthogonally polarized modes ar...Strong optical feedback in a birefringent dual frequency He-Ne laser with a high reflectivity feedback mirror has been investigated for the first time. The output characteristics of two orthogonally polarized modes are demonstrated in two different optical feedback cases: one is for both modes being fed back and the other is for only one of the modes being fed back. Strong mode competition can be observed between the two modes with strong optical feedback, And when one mode's intensity is near its maximum, the other mode is nearly extinguished. When both modes are fed back into the laser cavity, the mode competition is stronger than when only one mode is fed back, The difference in initial intensity between the two orthogonally polarized modes plays an important role in the mode competition, which has been experimentally and theoretically demonstrated.展开更多
A proton therapy(PT)facility with multiple treatment rooms based on the superconducting cyclotron scheme is under development at Huazhong University of Science and Technology(HUST).This paper attempts to describe the ...A proton therapy(PT)facility with multiple treatment rooms based on the superconducting cyclotron scheme is under development at Huazhong University of Science and Technology(HUST).This paper attempts to describe the design considerations and implementation of the PT beamline from a systematic viewpoint.Design considerations covering beam optics and the influence of high-order aberrations,beam energy/intensity modulation,and beam orbit correction are described.In addition to the technical implementation of the main beamline components and subsystems,including the energy degrader,fast kicker,beamline magnets,beam diagnostic system,and beamline control system are introduced.展开更多
基金Project supported by the State Key Program of National Natural Science of China (Grant No 60438010)
文摘This paper demonstrates the intensity modulation characters of orthogonally polarized HeNe lasers with different optical feedback level generated by the variable reflectivity of external reflector. The modulation depths of the orthogonally polarized frequencies are increased when the optical feedback level becomes strong. It also observes that the modulation amplitudes are different for different external cavity length. Based on the vectorial extension of Lamb's semi-classical theory, it finds that the calculations are consistent with the experimental results.
基金Project supported by the Zhejiang Provincial Natural ScienceFoundation of China(No.LQ13F050001)
文摘We present how residual intensity modulation(RIM) affects the performance of a resonator fiber optic gyro(R-FOG) through a sinusoidal wave phase modulation technique. The expression for the R-FOG system's demodulation curve under RIM is obtained. Through numerical simulation with different RIM coefficients and modulation frequencies, we find that a zero deviation is induced by the RIM effect on the demodulation curve, and this zero deviation varies with the RIM coefficient and modulation frequency. The expression for the system error due to this zero deviation is derived. Simulation results show that the RIM-induced error varies with the RIM coefficient and modulation frequency. There also exists optimum values for the RIM coefficient and modulation frequency to totally eliminate the RIM-induced error, and the error increases as the RIM coefficient or modulation frequency deviates from its optimum value; however, in practical situations, these two parameters would not be exactly fixed but fluctuate from their respective optimum values, and a large system error is induced even if there exists a very small deviation of these two critical parameters from their optimum values. Simulation results indicate that the RIM-induced error should be considered when designing and evaluating an R-FOG system.
文摘The characteristics of a conventional LiNbO3 intensity modulator made up of a Mach-Zehnder(MZ) type annealed proton exchange(APE) waveguide and coplanar waveguide(CPW) modulation electrode are presented. The APE waveguide characteristics and their relations with process parameters are analyzed. At the same time, the electrical characteristics of modulation electrode, such as modulation voltage, microwave effective index associated with modulation bandwidth, characteristics impedance, are also investigated in detail.
基金supported by Program for New Century Excellent Talents in University(No.NCET-06-0925)
文摘The modulation depth, defined according to practical modulation results, which changes with the microwave power and its frequency, is significant for systems utilizing the frequency-shift characteristic of the LiNbO3 waveguide Electro-Optic Intensity Modulator (EOIM). By analyzing the impedance mismatch between the microwave source and the EOIM, the effective voltage applied to the RF port of the EOIM is deprived from the microwave power and its frequency. Associating with analyses of the phase velocity mismatch between the microwave and the optical wave, the theoretical modulation depth has been obtained, which is verified by experimental results. We provide a method to choose the appropriate modulation depth to optimize the desired sideband through proper transmission bias for the system based on the frequency-shift characteristic of the EOIM.
基金support by the UK Engineering and Physical Sciences Research Council(EPSRC)under Grants EP/K008757/1 and EP/M506515/1
文摘Modulation techniques for light fidelity (Li-Fi) are reviewed in this paper. Li-Fi is the fully networked solution for nmltiple users that combines communication and illumination simultaneously. Light emitting diodes (LEDs) are used in Li-Fi as visible light transmitters, therefore, only intensity modulated direct detected modulation techniques can be achieved. Single carrier modulation techniques are straightforward to be used in Li-Fi, however, computationally complex equalization processes are required in fre- quency selective Li-Fi channels. On the other hand, multiearrier modulation techniques offer a viable solution for Li-Fi in terms of power, spectral and computational efficiency. In particular, orthogonal frequency division multiplexing (OFDM) based modulation techniques offer a practical solution for Li-Fi, especially when direct current (DC) wander, and adaptive bit and power loading techniques are considered. Li-Fi modulation techniques need to also satisfy illumination requirements. Flickering avoidance and dimming control are considered in the variant modulation techniques presented. This paper surveys the suitable modulation techniques for Li-Fi including those which explore time, frequency and colour domains.
基金Project supported by the National Natural Science Foundation of China(Grant No.61178089)the Key Program of Science and Technology of Fujian Province,China(Grant No.2011Y0019)the Educational Department of Fujian Province,China(Grant No.JA13074)
文摘An analytic equation interpreting the intensity of ultrasound-modulated scattering light is derived, based on diffusion theory and previous explanations of the intensity modulation mechanism. Furthermore, an experiment of ultrasonic modulation of incoherent light in a scattering medium is developed. This analytical model agrees well with experimental results,which confirms the validity of the proposed intensity modulation mechanism. The model supplements the existing research on the ultrasonic modulation mechanism of scattering light.
基金Supported by The Science and Technology Plan Project of Guangzhou,No.202102010171National Natural Science Foundation。
文摘BACKGROUND Primary liver cancer is a malignant tumor with a high recurrence rate that significantly affects patient prognosis.Postoperative adjuvant external radiation therapy(RT)has been shown to effectively prevent recurrence after liver cancer resection.However,there are multiple RT techniques available,and the differ-ential effects of these techniques in preventing postoperative liver cancer re-currence require further investigation.AIM To assess the advantages and disadvantages of various adjuvant external RT methods after liver resection based on overall survival(OS)and disease-free survival(DFS)and to determine the optimal strategy.METHODS This study involved network meta-analyses and followed the PRISMA guidelines.The data of qualified studies published before July 10,2023,were collected from PubMed,Embase,the Web of Science,and the Cochrane Library.We included relevant studies on postoperative external beam RT after liver resection that had OS and DFS as the primary endpoints.The magnitudes of the effects were determined using risk ratios with 95%confidential intervals.The results were analyzed using R software and STATA software.RESULTS A total of 12 studies,including 1265 patients with hepatocellular carcinoma(HCC)after liver resection,were included in this study.There was no significant heterogeneity in the direct paired comparisons,and there were no significant differences in the inclusion or exclusion criteria,intervention measures,or outcome indicators,meeting the assumptions of heterogeneity and transitivity.OS analysis revealed that patients who underwent stereotactic body radiotherapy(SBRT)after resection had longer OS than those who underwent intensity modulated radiotherapy(IMRT)or 3-dimensional conformal RT(3D-CRT).DFS analysis revealed that patients who underwent 3D-CRT after resection had the longest DFS.Patients who underwent IMRT after resection had longer OS than those who underwent 3D-CRT and longer DFS than those who underwent SBRT.CONCLUSION HCC patients who undergo liver cancer resection must consider distinct advantages and disadvantages when choosing between SBRT and 3D-CRT.IMRT,a RT technique that is associated with longer OS than 3D-CRT and longer DFS than SBRT,may be a preferred option.
文摘Subcarrier intensity modulation with direet detection is a modulatiou/detection technique tbr optical wireless communication systems, where a pre-modulated and properly biased radio frequency signal is modulated on the intensity of the optical carrier. The most important benefits of subcarrier intensity modulation are as follows: 1) it does not provide irreducible error floor like the conventional on-off keying intensity modulation with a fixed detection threshold; 2) it provides improved spectral efficiency and supports higher order modulation schemes; and 3) it has much less implementation complexity compared to coherent optical wireless communications with heterodyne or homodyne detection. In this paper, we present an up-to-date review of subcarrier intensity modulated optical wireless communication systems. We survey the error rate and outage performance of subcarrier intensity modulations in the atmospheric turbulence channels considering different modulation and coding schemes. We also explore different contemporary atmospheric turbulence fading mitigation solutions that can be employed for subcarrier intensity modulation. These solutions include diversity combining, adaptive transmission, relay assisted transmission, multiple-subcarrier intensity modulations, and optical orthogonal frequency division multiplexing. Moreover, we review the performance of subcarrier intensity modulations due to the pointing error and synchronization error.
基金supported by Program for New Century Excellent Talents in University under Grand No. NCET-06-0925.
文摘High-speed and wide-band LiNbO3 waveguide electro-optic intensity modulator has drawn great attention in the field of optical fiber communication and sensor. This paper reports the research results on the measurement of frequency shift characteristics of Mach-Zehnder electro-optic intensity modulator. Two measurement methods of frequency shift characteristics for high and low frequency modulations are studied in theory and experiment and demonstrate different results. The realization of a multi-wavelength optical source based on Mach-Zehnder electro-optic intensity modulator has been introduced. The technique to reach the maximum intensity for interesting shift frequency, particularly for heterodyne detection of Brillouin distributed optical fiber sensing, has been given.
基金Supported by the Joint Research Fund in Astronomy under Cooperative Agreement between the National Natural Science Foundation of China and Chinese Academy of Sciences under Grant No U1531102the Fundamental Research Funds for the Central Universities under Grant No HEUCF181116the National Natural Science Foundation of China under Grant Nos61107059,61077047 and 11264001
文摘We propose a novel light intensity modulator based on magnetic fluid and liquid crystal(LC) filled photonic crystal fibers(PCFs). The influences of electric and magnetic fields on the transmission intensity are theoretically and experimentally analyzed and investigated. Both the electric and magnetic fields can manipulate the molecular arrangement of LC to array a certain angle without changing the refractive index of the LC. Therefore, light loss in the PCF varies with the electric and magnetic fields whereas the peak wavelengths remain constant. The experimental results show that the transmission intensity decreases with the increase of the electric and magnetic fields. The cut-off electric field is 0.899 V/um at 20 Hz and the cut-off magnetic field is 195 m T. This simple and compacted optical modulator will have a great prospect in sensing applications.
文摘Objective:Serum prostate specific antigen(PSA)is commonly used to evaluate treatment response after definitive radiation therapy(RT).However,PSA levels can temporarily rise without a clear reason,termed“PSA bounce”,and often engender great anxiety for both patients and physicians.The present study aimed to determine the prevalence and factors that predict“PSA bounce”after intensity-modulated radiation therapy(IMRT),and the relevance to biochemical failure and cancer recurrence in an Asian population.Methods:We retrospectively reviewed 206 patients who received IMRT for prostate cancer from 2004 to 2012 in the National Cancer Centre Singapore.These patients were followed up with regular PSA monitoring.We defined“PSA bounce”as a rise of 0.1 ng/mL,followed by two consecutive falls.Patients with biochemical failure(PSA nadir t 2 ng/mL)were further evaluated for cancer recurrence.Results:Sixty-one patients(29.6%)experienced“PSA bounce”,at a median time of 16 months and lasted for 12 months.Age remained the most consistent predictor of the incidence,duration and extent of“PSA bounce”.Other contributory factors included baseline PSA,Gleason score and PSA nadir.Hormonal therapy and prostate volume did not affect this phenomenon.Sixteen patients(7.8%)developed biochemical recurrence,at median time of 32 months,of which 11 were confirmed to have metastatic disease.The median follow-up time was 71 months.
基金Supported by a grant from Health Bureau of Lianyungang City’s Fund Program (No. 05051).
文摘Objective: To evaluate the clinical effects of concurrent and sequential therapy for middle and advanced stage non-small cell lung cancer (NSCLC) useing IMRT combined with NP regimen chemotherapy. Methods: Eighty patients with middle and advanced stage NSCLC were randomized into two groups. Forty patients were underwent sequential therapy and other 40 patients were underwent concurrent therapy. IMRT was used in radiotherapy and NP regimen of vinorelbine+cispatin (NP) was used in chemotherapy. Results: (1) The overall response (CR+PR) rate was 75% in concurrent group and 45% in sequential group (P<0.05); (2) The treatment courses were 84 days and 140 days for concurrent group and sequential group respectively (P<0.05); (3) One-year survival rate in concurrent group was 72.4% and 52.3% in sequential group respectively; (4) The toxic effects can be tolerable by all of patients. Conclusion: The concurrent chemo-radiotherapy has better overall re- sponse, one-year survival rate and shorter treatment course than the sequential chemo-radiotherapy, so it is a better method for the treatment of middle and advanced stage NSCLC, but the long term survival rate will be studied.
文摘Objective: The purpose of this study was to investigate the impact of intensity modulated radiotherapy (IMRT) on surface doses for brain, abdomen and pelvis deep located tumors treated with 6 MV photon and to evaluate the skin dose calculation accuracy of the XIO 4.04 treatment planning system. Methods: More investigations for the influences of IMRT on skin doses would increase its applications for many treatment sites. Measuring skin doses in real treatment situations would reduce the uncertainty of skin dose prediction. In this work a pediatric human phantom was covered by a layer of 1 mm bolus at three treatment sites and thermoluminescent dosimeter (TLD) chips were inserted into the bolus at each treatment site before CT scan. Two different treatment plans [three-dimensional conformal radiation therapy (3DCRT) and IMRT] for each treatment sites were performed on XIO 4.04 treatment planning system using superposition algorism. Results: The results showed that the surface doses for 3DCRT were higher than the surface doses in IMRT by 1.6%, 2.5% and 3.2% for brain, abdomen and pelvis sites respectively. There was good agreement between measured and calculated surface doses, where the calculated surface dose was 15.5% for brain tumor calculated with 3DCRT whereas the measured surface dose was 12.1%. For abdomen site the calculated surface dose for IMRT treatment plan was 16.5% whereas the measured surface dose was 12.6%. Conclusion: The skin dose in IMRT for deep seated tumors is lower than that in 3DCRT which is another advantage for the IMRT. The TLD readings showed that the difference between the calculated and measured point dose is negligible. The superposition calculation algorism of the XIO 4.04 treatment planning system modeled the superficial dose well.
文摘Objective:This study was to compare 5 field conformal technique to the intensity modulated radiotherapy (IMRT) 8 fields technique in boosting locally advanced cancer cervix cases after external beam radiotherapy with respect to target volume coverage and dose to normal tissues. Methods:We conducted a single institutional comparative dosimetric analysis of 10 patients with cancer cervix who was presented to radiotherapy department in National Cancer Institute, Cairo in period between June 2012 to September 2012 and received a CRT boost in the place of planned brachytherapy after large field pelvic radiotherapy (PRT) with concurrent chemotherapy were retrospectively identified. All tumors were situated in the low central pelvis. Two plans were done for every patient; one using the 8 fields IMRT and the second one using 5 fields' 3DCRT the two techniques were then compared using dose volume histogram (DVH) analysis for the PTV, bladder, rectum and both femoral heads. Results:Comparing different DVHs, it was found that the planning target volume (PTV) was adequately covered in both plans while it was demonstrates that the 8 fields IMRT technique carried less doses reaching OARs (rectum, bladder, both femoral heads). Conclusion:From the present study, it is concluded that IMRT technique spared more efficiently OARs than CRT technique but both techniques covered the PTV adequately so whenever possible IMRT technique should be used.
基金Sponsored by the National Natural Science Foundation of China(Grant No.51775260)the Qinglan Project of Jiangsu Province(2017)of China and the Funds of Nanjing Institute of Technology(Grant No.CKJA201801).
文摘Optical fibre sensor has the advantages of small size,light weight,anti⁃electromagnetic interference,and high measurement accuracy,which has important applications in research and industrial production.To design an optical fibre displacement sensor(OFBDS)with simple structure and high measurement accuracy,the unified model of the commonly used OFBDS structures was proposed and the feasibility of the intensity⁃modulation of multi⁃structural optical fibre bundles was analysed based on the arrangement characteristics of the fibre bundle end⁃face.The intensity⁃modulation characteristic of different fibre bundles was analysed,and the single coil coaxial fibre bundle was chosen as the fibre probe in this study.The sensor hardware system was designed.Lastly,the calibration experiment,temperature interference experiment,changes of measured plane surface area,and the dynamic experiment were conducted.Results showed that the sensor linear measurement range was about 3 mm,and the sensor system had excellent static and dynamic characteristics.
文摘Patients with recurrent breast cancer to chest wall, who had previous irradiation, are difficult to manage and have limited options. Several reports described the use of photon therapy, hyperthermia, and brachytherapy. This is a case report of a 72-year-old female with Stage IIIA (pT3N1M0) invasive ductal carcinoma of the right breast status post modified radical mastectomy. The patient developed recurrence to the chest wall and one internal mammary lymph node one year later. She received 3-D conformal photon radiation therapy for this recurrence. Two years later, she had progression of the recurrence at the right chest wall and axillary and internal mammary lymph nodes. She was treated with intensity modulated proton therapy (IMPT) for a total of 6600 cGy in 33 fractions. However, four months later, she was found to have biopsy-proven isolated metastatic disease at her right bicep, which was again treated with IMPT for a dose of 6000 cGy in 20 fractions. Proton beam therapy was used in this case to spare dose to the brachial plexus, heart and lung while optimally irradiating the recurrent tumors. At last follow up, the patient is alive and has been disease free for 39 months. This report describes the technique and dosimetry for this unique case, which also reviewed recent series of re-irradiation using proton beam.
文摘Introduction: Nasopharyngeal carcinomas are the most radiation-sensitive tumours, and radiotherapy alone provides better local control. Objectives: To evaluate the clinical efficacy and acute and late toxicities of two different treatment regimens for locally advanced nasopharyngeal carcinoma. Methods: From 2014 to 2017, 150 cases of stage III and 68 cases of stage IVA nasopharyngeal carcinoma were treated. Of these, 137 received conventional radiotherapy plus chemotherapy, and 81 received intensity-modulated radiotherapy plus chemotherapy. Chemotherapy was given either as induction, concurrent or adjuvant therapy. Survival rates were calculated according to Kaplan Meier and compared with the Log-rank test. The RTOG or EORTC criteria were used to assess acute and late toxicities. Results: The median follow-up time was 21.5 months, and the 2-year locoregional relapse-free survival, distant metastases-free survival, and overall survival rates in the conventional radiotherapy plus chemotherapy group were 76%, 71% and 77%, respectively;in the intensity-modulated radiotherapy plus chemotherapy group, they were 97%, 84%, and 100%, respectively. The difference in survival between the two groups was significant (χ<sup>2</sup> = 5.06, P = 0.028). The incidence of grade 2 and 3 xerostomia one year after radiotherapy was 45.1% and 30.9% versus 33.3% and 0%. Conclusion: Compared with conventional radiotherapy plus chemotherapy, intensity-modulated radiotherapy plus chemotherapy offers better locoregional relapse-free survival and overall survival in patients with stage III and IVA nasopharyngeal carcinoma, and may significantly reduce the occurrence of radiation-induced xerostomia.
基金Project supported by the National Natural Science Foundation of China (Grant No 60438010).
文摘The mode hopping phenomenon induced by optical feedback in single-mode microchip Nd:YAG lasers is presented. With optical feedback, mode hopping strongly depends on two factors: the ratio of external cavity length to intra-cavity length, and initial gains of the two hopping modes, When external cavity length equals an integral multiple of intracavity length, there is almost no mode hopping. However, if the external cavity length does not equal an integral multiple of intra-cavity length, mode hopping occurs. The ratio of external cavity length to intra-cavity length determines the position of two-mode hopping, The initial gains of the two hopping modes determine the corresponding peak values and oscillating periods of them in the intensity modulation curves.
基金Project supported by the Major Program of National Natural Science Foundation of China (Grant No 60438010).
文摘Strong optical feedback in a birefringent dual frequency He-Ne laser with a high reflectivity feedback mirror has been investigated for the first time. The output characteristics of two orthogonally polarized modes are demonstrated in two different optical feedback cases: one is for both modes being fed back and the other is for only one of the modes being fed back. Strong mode competition can be observed between the two modes with strong optical feedback, And when one mode's intensity is near its maximum, the other mode is nearly extinguished. When both modes are fed back into the laser cavity, the mode competition is stronger than when only one mode is fed back, The difference in initial intensity between the two orthogonally polarized modes plays an important role in the mode competition, which has been experimentally and theoretically demonstrated.
基金the National Key Research and Development Program of China(No.2016YFC0105305)the National Natural Science Foundation of China(11975107)the Program for HUST Academic Frontier Youth Team.
文摘A proton therapy(PT)facility with multiple treatment rooms based on the superconducting cyclotron scheme is under development at Huazhong University of Science and Technology(HUST).This paper attempts to describe the design considerations and implementation of the PT beamline from a systematic viewpoint.Design considerations covering beam optics and the influence of high-order aberrations,beam energy/intensity modulation,and beam orbit correction are described.In addition to the technical implementation of the main beamline components and subsystems,including the energy degrader,fast kicker,beamline magnets,beam diagnostic system,and beamline control system are introduced.