期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Simultaneous integrated boost IMRT in pediatric:evaluation for two commercial treatment planning systems
1
作者 Ehab M.Attalla Ismail Eldesoky Eman Eldebawy 《The Chinese-German Journal of Clinical Oncology》 CAS 2013年第1期6-14,共9页
Objective: The aim of the work was to compare the dosimetric results that were obtained by using two treatment planning systems (TPS) Siemens KonRad version 2.2.23, Elekta XiO version 4.4 to perform a simultaneous ... Objective: The aim of the work was to compare the dosimetric results that were obtained by using two treatment planning systems (TPS) Siemens KonRad version 2.2.23, Elekta XiO version 4.4 to perform a simultaneous integrated boost (SIB) for head and neck and central nervous system (CNS) cases in paediatric patients. Methods: The CT scan data for five paediatric patients, with head and neck and CNS tumors, were transferred into both of the TPSs. Clinical step-and-shoot intensity-modulated radiotherapy (IMRT) treatment plans were designed using 6 MV photon beam for delivery on a Siemens Oncor Accelerator with multileaf collimator MLC (82 leaf). Plans were optimized to achieve the same clinical objectives using the same beam energy, number and direction of beams. The analysis was based on isodose distributions, the dose volume histogram (DVH) for planning target volume (PTV) and the relevant organs at risk (OARs) as well as volume receiving 2 Gy and 5 Gy, also total number of segments, MU/segment, and the number of MU/cGy had been investigated. Treatment delivery time and conformation number were two other parameters in this study. Results: The segmentation using KonRad was more efficient, resulting in fewer segments (reduction between 13.2% and 48.3%), fewer M Us (reduction between 10.7% and 33%) and that reflected on treatment delivery times to be shorter by up to 8 rain or 46%. In most of the cases KonRad had the highest volume receiving in excess of 2 and 5 Gy, and XiO showed the lowest. Also KonRad achieved slightly better conformality (0.76 ± 0.054) than XiO (0.73 ± 0.05) while XiO presented a higher modulation factor value (3.3 MU/cGy) than KonRad (2.4 MU/cGy). Conclusion: The KonRad treatment planning system was found to be superior to the XiO treatment planning system. This is true for the possible increase of radiation-induced secondary malignancies as well as for the local control. 展开更多
关键词 intensity-modulated radiotherapy (IMRT) KonRad simultaneous integrated boost (SIB) XiO
下载PDF
调强同期推量照射技术治疗脑恶性胶质瘤的可行性研究 被引量:2
2
作者 朱卫国 韩济华 +4 位作者 李涛 陶光州 于长华 彭进 周锡垒 《西部医学》 2009年第4期600-602,共3页
目的研究调强同期推量照射技术治疗脑恶性胶质瘤的可行性。方法本研究涉及6例病理确诊的恶性胶质瘤。根据ICRU 50号和62号报告要求勾画肿瘤靶区,用调强同期推量照射技术(SIB-IMRT)治疗,通过CMS逆向计划计算系统分别得出肿瘤靶区的剂量... 目的研究调强同期推量照射技术治疗脑恶性胶质瘤的可行性。方法本研究涉及6例病理确诊的恶性胶质瘤。根据ICRU 50号和62号报告要求勾画肿瘤靶区,用调强同期推量照射技术(SIB-IMRT)治疗,通过CMS逆向计划计算系统分别得出肿瘤靶区的剂量分布情况以及肿瘤周围重要器官的照射剂量。结果所有患者都顺利完成治疗,无放疗所致的毒性反应。随访过程中5例患者局部复发,3例GBM死亡。靶区剂量分布满意,各重要器官的照射量亦明显达到较低水平。结论用调强同期推量照射技术治疗脑恶性胶质瘤从剂量学和放射生物学角度来看有一定的优势。 展开更多
关键词 调强放射治疗 恶性胶质瘤 同期推量照射
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部