This article investigates the power quality enhancement in power system using one of the most famous series converter based FACTS controller like IPFC (Interline Power Flow Controller) in Power Injection Model (PIM). ...This article investigates the power quality enhancement in power system using one of the most famous series converter based FACTS controller like IPFC (Interline Power Flow Controller) in Power Injection Model (PIM). The parameters of PIM are derived with help of the Newton-Raphson power flow algorithm. In general, a sample test power system without FACTs devices has generated more reactive power, decreased real power, more harmonics, small power factor and poor dynamic performance under line and load variations. In order to improve the real power, compensating the reactive power, proficient power factor and excellent load voltage regulation in the sample test power system, an IPFC is designed. The D-Q technique is utilized here to derive the reference current of the converter and its D.C link capacitor voltage is regulated. Also, the reference voltage of the inverter is arrived by park transformation technique and its load voltage is controlled. Here, a sample 230 KV test power system is taken for study. Further as the conventional PI controllers are designed at one nominal operating point they are not competent to respond satisfactorily in dynamic operating conditions. This can be circumvented by a Fuzzy and Neural network based IPFC and its detailed Simulink model is developed using MATLAB and the overall performance analysis is carried out under different operating state of affairs.展开更多
As one of the new generation flexible AC transmission systems(FACTS)devices,the interline power flow controller(IPFC)has the significant advantage of simultaneously regulating the power flow of multiple lines.Neverthe...As one of the new generation flexible AC transmission systems(FACTS)devices,the interline power flow controller(IPFC)has the significant advantage of simultaneously regulating the power flow of multiple lines.Nevertheless,how to choose the appropriate location for the IPFC converters has not been discussed thoroughly.To solve this problem,this paper proposes a novel location method for IPFC using entropy theory.To clarify IPFC’s impact on system power flow,its operation mechanism and control strategies of different types of serial converters are discussed.Subsequently,to clarify the system power flow characteristic suitable for device location analysis,the entropy concept is introduced.In this process,the power flow distribution entropy index is used as an optimization index.Using this index as a foundation,the power flow transfer entropy index is also generated and proposed for the IPFC location determination study.Finally,electromechanical electromagnetic hybrid simulations based on ADPSS are implemented for validation.These are tested in a practical power grid with over 800 nodes.A modular multilevel converter(MMC)-based IPFC electromagnetic model is also established for precise verification.The results show that the proposed method can quickly and efficiently complete optimized IPFC location and support IPFC to determine an optimal adjustment in the N-1 fault cases.展开更多
A single machine-infinite-bus(SMIB) system including the interline power flow controllers(IPFCs) and the power system stabilizer(PSS) controller is addressed. The linearized system model is considered for investigatin...A single machine-infinite-bus(SMIB) system including the interline power flow controllers(IPFCs) and the power system stabilizer(PSS) controller is addressed. The linearized system model is considered for investigating the interactions among IPFC and PSS controllers. To improve the stability of whole system again different disturbances, a lead-lag controller is considered to produce supplementary signal. The proposed supplementary controller is implemented to improve the damping of the power system low frequency oscillations(LFOs). Imperialist optimization algorithm(ICA) and shuffled frog leaping algorithm(SFLA) are implemented to search for optimal supplementary controllers and PSS parameters. Moreover, singular value decomposition(SVD) method is utilized to select the most effective damping control signal of IPFC lead-lag controllers. To evaluate the system performance, different operating conditions are considered. Reponses of system in five modes including uncoordinated and coordinated modes of IPFC and PSS using ICA and SFLA are studied and compared. Considering the results, response of system without controller shows the highest overshoot and the longest settling time for rotor angel at the different operating conditions. In this mode of system, rotor speed has the highest overshoot. Rotor angel in the system with only PSS includes lower overshoot and oscillation than system without controller. When PSS is only implemented, rotor speed deviation has the longest settling time. Rotor speed deviation in the uncoordinated mode of IPFC and PSS shows lower overshoot than system with only PSS and without controller. It is noticeable that in this mode, rotor angel has higher overshoot than system with only PSS. The superiority of the suggested ICA-based coordinated controllers is obvious compared with SFLA-based coordinated controllers and other system modes. Responses of coordinated PSS and IPFC SFLA-based supplementary controllers include higher peak amplitude and longer settling time compared with coordinated IPFC and PSS ICA-based controllers. This comparison shows that overshoots, undershoots and the settling times are reduced considerably in coordinated mode of IPFC based controller and PSS using ICA. Analysis of the system performance shows that the proposed method has excellent response to different faults in power system.展开更多
The restructuring of the electric power market has led to complex power transmission congestion problems.Additionally,scheduled power flows in the transmission line,as well as spontaneous power exchanges have also ris...The restructuring of the electric power market has led to complex power transmission congestion problems.Additionally,scheduled power flows in the transmission line,as well as spontaneous power exchanges have also risen sharply in recent years.The proper placement of IPFC can improve the transmission line congestion problem to a great extent.This paper proposes a disparity line utilization factor(DLUF)for the optimal placement of IPFC to control the congestion in transmission lines.DLUF determines the difference between the percentages of Mega Volt Ampere utilization of each line connected to the same bus.The IPFC is placed in the lines with maximum DLUF.A multiobjective function consisting of reduction of active power loss,minimization of total voltage deviations,minimization of security margin and minimization of installed IPFC capacity is considered for the optimal tuning of IPFC using differential evolution algorithm.The proposed method is implemented for IEEE-30 bus test system under different loading conditions and the results are presented and analyzed to establish the effectiveness on the reduction of congestion.展开更多
With the continuous expansion of power systems and the application of power electronic equipment, forced oscillation has become one of the key problems in terms of system safety and stability. In this paper, an interl...With the continuous expansion of power systems and the application of power electronic equipment, forced oscillation has become one of the key problems in terms of system safety and stability. In this paper, an interline power flow controller (IPFC) is used as a power suppression carrier and its mechanism is analyzed using the linearized state-space method to improve the system damping ratio. It is shown that although the IPFC can suppress forced oscillation with well-designed parameters, its capability of improving the system damping ratio is limited. Thus, combined with the repetitive control method, an additional repetitive controller (ARC) is proposed to further dampen the forced power oscillation. The ARC control scheme is characterized by outstanding tracking performance to a system steady reference value, and the main IPFC controller with the ARC can provide higher damping, and further reduce the amplitude of oscillations to zero compared with a supplementary damping controller (SDC). Simulation results show that the IPFC with an ARC can not only greatly reduce the oscillation amplitude, but also actively output the compensation power according to the reference value of the ARC tracking system.展开更多
In this paper, an interline power flow controller (IPFC) is used for controlling multi transmission lines. However, the optimal placement of IPFC in the transmis-sion line is a major problem. Thus, we use a combinat...In this paper, an interline power flow controller (IPFC) is used for controlling multi transmission lines. However, the optimal placement of IPFC in the transmis-sion line is a major problem. Thus, we use a combination of tabu search (TS) algorithm and artificial neural network (ANN) in the proposed method to find out the best placement locations for IPFC in a given multi transmission line system. TS algorithm is an optimization algorithm and we use it in the proposed method to determine the optimum bus combination using line data. Then, using the optimum bus combination, the neural network is trained to find out the best placement locations for IPFC. Finally, IPFC is connected at the best locations indicated by the neural network. Furthermore, using Newton-Raphson load flow algorithm, the transmission line loss of the IPFC connected bus is analyzed. The proposed methodology is implemen- ted in MATLAB working platform and tested on the IEEE-14 bus system. The output is compared with the genetic algorithm (GA) and general load flow analysis. The results are validated with Levenberg-Marquardt back propagation and gradient descent with momentum network training algorithm.展开更多
由平衡变压器和综合潮流控制器(integrated power flow controller,IPFC)组合构成的同相牵引供电系统可解决负序电流、谐波电流、无功电流的补偿及电分相方面存在的问题,分析了该供电系统的补偿原理,比较了牵引和再生制动状态同相牵引...由平衡变压器和综合潮流控制器(integrated power flow controller,IPFC)组合构成的同相牵引供电系统可解决负序电流、谐波电流、无功电流的补偿及电分相方面存在的问题,分析了该供电系统的补偿原理,比较了牵引和再生制动状态同相牵引供电系统对电力系统供电质量的影响,指出制动状态下IPFC可在不改变控制策略的情况下将能量平衡地回馈到三相电网,节约电能。仿真结果验证了同相牵引供电方案的正确性。展开更多
基于YNvd平衡变压器和综合潮流控制器(integrated power flow controller,IPFC)相结合构成的同相供电系统,在机车运行状态改变时进行了仿真分析。当同相供电系统采用传统型电流检测方法,在机车由牵引状态转变为电气制动状态时,由于传统...基于YNvd平衡变压器和综合潮流控制器(integrated power flow controller,IPFC)相结合构成的同相供电系统,在机车运行状态改变时进行了仿真分析。当同相供电系统采用传统型电流检测方法,在机车由牵引状态转变为电气制动状态时,由于传统型电流检测方法的缺陷性,IPFC直流侧电容电压会急剧上升。而基于Fryze功率定义的改进型电流检测方法则可以避免该问题,另外改进型电流检测方法可应用于部分补偿模式。仿真结果证明了改进型电流检测方法的可行性。展开更多
线间潮流控制器(interline power flow controller,IPFC)作为第3代柔性交流输电系统(flexible AC transmission system,FACTS)的代表性设备,具有强大的潮流调控能力。而IPFC的引入,会增加潮流优化(optimal power flow,OPF)问题的非凸性...线间潮流控制器(interline power flow controller,IPFC)作为第3代柔性交流输电系统(flexible AC transmission system,FACTS)的代表性设备,具有强大的潮流调控能力。而IPFC的引入,会增加潮流优化(optimal power flow,OPF)问题的非凸性,导致其难以被准确、快速求解。为解决传统IPFC模型中等效电压源相角对应约束难以被凸化的问题,该文基于注入功率变量重新构造了IPFC的等效约束,并进一步利用数学变形、近似处理、二进制展开技术,对该模型进行凸化处理,将含IPFC的OPF问题从高度非凸的优化问题转化为混合整数二阶锥规划(mixed integer second-order cone programming,MISOCP)问题。最终,在仿真算例中完成近似误差分析,并利用Matlab/Gurobi求解MISOCP模型。结果表明,所提优化方法计算精度高,求解速度快,显著降低了系统发电成本,可为综合型FACTS的在线优化调控提供理论和技术支撑。展开更多
文摘This article investigates the power quality enhancement in power system using one of the most famous series converter based FACTS controller like IPFC (Interline Power Flow Controller) in Power Injection Model (PIM). The parameters of PIM are derived with help of the Newton-Raphson power flow algorithm. In general, a sample test power system without FACTs devices has generated more reactive power, decreased real power, more harmonics, small power factor and poor dynamic performance under line and load variations. In order to improve the real power, compensating the reactive power, proficient power factor and excellent load voltage regulation in the sample test power system, an IPFC is designed. The D-Q technique is utilized here to derive the reference current of the converter and its D.C link capacitor voltage is regulated. Also, the reference voltage of the inverter is arrived by park transformation technique and its load voltage is controlled. Here, a sample 230 KV test power system is taken for study. Further as the conventional PI controllers are designed at one nominal operating point they are not competent to respond satisfactorily in dynamic operating conditions. This can be circumvented by a Fuzzy and Neural network based IPFC and its detailed Simulink model is developed using MATLAB and the overall performance analysis is carried out under different operating state of affairs.
基金supported by the Natural Science Foundation of Sichuan Province of China(No.2022NSFSC0262)the Fundamental Research Funds for the Central Universities(No.2022SCU12005).
文摘As one of the new generation flexible AC transmission systems(FACTS)devices,the interline power flow controller(IPFC)has the significant advantage of simultaneously regulating the power flow of multiple lines.Nevertheless,how to choose the appropriate location for the IPFC converters has not been discussed thoroughly.To solve this problem,this paper proposes a novel location method for IPFC using entropy theory.To clarify IPFC’s impact on system power flow,its operation mechanism and control strategies of different types of serial converters are discussed.Subsequently,to clarify the system power flow characteristic suitable for device location analysis,the entropy concept is introduced.In this process,the power flow distribution entropy index is used as an optimization index.Using this index as a foundation,the power flow transfer entropy index is also generated and proposed for the IPFC location determination study.Finally,electromechanical electromagnetic hybrid simulations based on ADPSS are implemented for validation.These are tested in a practical power grid with over 800 nodes.A modular multilevel converter(MMC)-based IPFC electromagnetic model is also established for precise verification.The results show that the proposed method can quickly and efficiently complete optimized IPFC location and support IPFC to determine an optimal adjustment in the N-1 fault cases.
文摘A single machine-infinite-bus(SMIB) system including the interline power flow controllers(IPFCs) and the power system stabilizer(PSS) controller is addressed. The linearized system model is considered for investigating the interactions among IPFC and PSS controllers. To improve the stability of whole system again different disturbances, a lead-lag controller is considered to produce supplementary signal. The proposed supplementary controller is implemented to improve the damping of the power system low frequency oscillations(LFOs). Imperialist optimization algorithm(ICA) and shuffled frog leaping algorithm(SFLA) are implemented to search for optimal supplementary controllers and PSS parameters. Moreover, singular value decomposition(SVD) method is utilized to select the most effective damping control signal of IPFC lead-lag controllers. To evaluate the system performance, different operating conditions are considered. Reponses of system in five modes including uncoordinated and coordinated modes of IPFC and PSS using ICA and SFLA are studied and compared. Considering the results, response of system without controller shows the highest overshoot and the longest settling time for rotor angel at the different operating conditions. In this mode of system, rotor speed has the highest overshoot. Rotor angel in the system with only PSS includes lower overshoot and oscillation than system without controller. When PSS is only implemented, rotor speed deviation has the longest settling time. Rotor speed deviation in the uncoordinated mode of IPFC and PSS shows lower overshoot than system with only PSS and without controller. It is noticeable that in this mode, rotor angel has higher overshoot than system with only PSS. The superiority of the suggested ICA-based coordinated controllers is obvious compared with SFLA-based coordinated controllers and other system modes. Responses of coordinated PSS and IPFC SFLA-based supplementary controllers include higher peak amplitude and longer settling time compared with coordinated IPFC and PSS ICA-based controllers. This comparison shows that overshoots, undershoots and the settling times are reduced considerably in coordinated mode of IPFC based controller and PSS using ICA. Analysis of the system performance shows that the proposed method has excellent response to different faults in power system.
文摘The restructuring of the electric power market has led to complex power transmission congestion problems.Additionally,scheduled power flows in the transmission line,as well as spontaneous power exchanges have also risen sharply in recent years.The proper placement of IPFC can improve the transmission line congestion problem to a great extent.This paper proposes a disparity line utilization factor(DLUF)for the optimal placement of IPFC to control the congestion in transmission lines.DLUF determines the difference between the percentages of Mega Volt Ampere utilization of each line connected to the same bus.The IPFC is placed in the lines with maximum DLUF.A multiobjective function consisting of reduction of active power loss,minimization of total voltage deviations,minimization of security margin and minimization of installed IPFC capacity is considered for the optimal tuning of IPFC using differential evolution algorithm.The proposed method is implemented for IEEE-30 bus test system under different loading conditions and the results are presented and analyzed to establish the effectiveness on the reduction of congestion.
基金funded by Jiangsu electric power company project“key technology research on planning and demonstration application of inter line power flow controller”,J2020088.
文摘With the continuous expansion of power systems and the application of power electronic equipment, forced oscillation has become one of the key problems in terms of system safety and stability. In this paper, an interline power flow controller (IPFC) is used as a power suppression carrier and its mechanism is analyzed using the linearized state-space method to improve the system damping ratio. It is shown that although the IPFC can suppress forced oscillation with well-designed parameters, its capability of improving the system damping ratio is limited. Thus, combined with the repetitive control method, an additional repetitive controller (ARC) is proposed to further dampen the forced power oscillation. The ARC control scheme is characterized by outstanding tracking performance to a system steady reference value, and the main IPFC controller with the ARC can provide higher damping, and further reduce the amplitude of oscillations to zero compared with a supplementary damping controller (SDC). Simulation results show that the IPFC with an ARC can not only greatly reduce the oscillation amplitude, but also actively output the compensation power according to the reference value of the ARC tracking system.
文摘In this paper, an interline power flow controller (IPFC) is used for controlling multi transmission lines. However, the optimal placement of IPFC in the transmis-sion line is a major problem. Thus, we use a combination of tabu search (TS) algorithm and artificial neural network (ANN) in the proposed method to find out the best placement locations for IPFC in a given multi transmission line system. TS algorithm is an optimization algorithm and we use it in the proposed method to determine the optimum bus combination using line data. Then, using the optimum bus combination, the neural network is trained to find out the best placement locations for IPFC. Finally, IPFC is connected at the best locations indicated by the neural network. Furthermore, using Newton-Raphson load flow algorithm, the transmission line loss of the IPFC connected bus is analyzed. The proposed methodology is implemen- ted in MATLAB working platform and tested on the IEEE-14 bus system. The output is compared with the genetic algorithm (GA) and general load flow analysis. The results are validated with Levenberg-Marquardt back propagation and gradient descent with momentum network training algorithm.
文摘由平衡变压器和综合潮流控制器(integrated power flow controller,IPFC)组合构成的同相牵引供电系统可解决负序电流、谐波电流、无功电流的补偿及电分相方面存在的问题,分析了该供电系统的补偿原理,比较了牵引和再生制动状态同相牵引供电系统对电力系统供电质量的影响,指出制动状态下IPFC可在不改变控制策略的情况下将能量平衡地回馈到三相电网,节约电能。仿真结果验证了同相牵引供电方案的正确性。
文摘基于YNvd平衡变压器和综合潮流控制器(integrated power flow controller,IPFC)相结合构成的同相供电系统,在机车运行状态改变时进行了仿真分析。当同相供电系统采用传统型电流检测方法,在机车由牵引状态转变为电气制动状态时,由于传统型电流检测方法的缺陷性,IPFC直流侧电容电压会急剧上升。而基于Fryze功率定义的改进型电流检测方法则可以避免该问题,另外改进型电流检测方法可应用于部分补偿模式。仿真结果证明了改进型电流检测方法的可行性。
文摘线间潮流控制器(interline power flow controller,IPFC)作为第3代柔性交流输电系统(flexible AC transmission system,FACTS)的代表性设备,具有强大的潮流调控能力。而IPFC的引入,会增加潮流优化(optimal power flow,OPF)问题的非凸性,导致其难以被准确、快速求解。为解决传统IPFC模型中等效电压源相角对应约束难以被凸化的问题,该文基于注入功率变量重新构造了IPFC的等效约束,并进一步利用数学变形、近似处理、二进制展开技术,对该模型进行凸化处理,将含IPFC的OPF问题从高度非凸的优化问题转化为混合整数二阶锥规划(mixed integer second-order cone programming,MISOCP)问题。最终,在仿真算例中完成近似误差分析,并利用Matlab/Gurobi求解MISOCP模型。结果表明,所提优化方法计算精度高,求解速度快,显著降低了系统发电成本,可为综合型FACTS的在线优化调控提供理论和技术支撑。