期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
Simulation of an imaging system for internal contamination of lungs using MPA-MURA coded-aperture collimator 被引量:6
1
作者 Ting Zhang Lei Wang +4 位作者 Jing Ning Wei Lu Xiao-Fei Wang Hai-Wei Zhang Xian-Guo Tuo 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2021年第2期58-69,共12页
The nuclides inhaled during nuclear accidents usually cause internal contamination of the lungs with low activity.Although a parallel-hole imaging system,which is widely used in medical gamma cameras,has a high resolu... The nuclides inhaled during nuclear accidents usually cause internal contamination of the lungs with low activity.Although a parallel-hole imaging system,which is widely used in medical gamma cameras,has a high resolution and good image quality,owing to its extremely low detection efficiency,it remains difficult to obtain images of inhaled lung contamination.In this study,the Monte Carlo method was used to study the internal lung contamination imaging using the MPA-MURA coded-aperture collimator.The imaging system consisted of an adult male lung model,with a mosaicked,pattern-centered,and anti-symmetric MURA coded-aperture collimator model and a CsI(Tl)detector model.The MLEM decoding algorithm was used to reconstruct the internal contamination image,and the complementary imaging method was used to reduce the number of artifacts.The full width at half maximum of the I-131 point source image reconstructed by the MPAMURA coded-aperture imaging reached 2.51 mm,and the signal-to-noise ratio of the simplified respiratory tract source(I-131)image reconstructed through MPA-MURA coded-aperture imaging was 3.98 dB.Although the spatial resolution of MPA-MURA coded-aperture imaging is not as good as that of parallel-hole imaging,the detection efficiency of PMA-MURA coded-aperture imaging is two orders of magnitude higher than that of parallel-hole collimator imaging.Considering the low activity level of internal lung contamination caused by nuclear accidents,PMA-MURA coded-aperture imaging has significant potential for the development of lung contamination imaging. 展开更多
关键词 Lung internal contamination MPA-MURA Monte Carlo MLEM Spatial resolution Detection efficiency
下载PDF
GROSS ALPHA DETERMINATION IN URINE
2
作者 贾国纲 《Nuclear Science and Techniques》 SCIE CAS CSCD 1995年第2期95-103,共9页
A short review is given for the determination of gross alpha activity ill urine;detailed information is collected including urine mineralization,separation of alpha emitters and source preparation.
关键词 URINE Gross alpha MINERALIZATION internal contamination Alpha spectrometry ZnS(Ag) scintillation detectors
下载PDF
PRELIMINARY PROGRAMMED WHOLE-BODY COUNTER
3
作者 张少东 郑文忠 +6 位作者 安永峰 李伟博 申成摇 唐明华 程昕 郭力生 周淑珍 《Nuclear Science and Techniques》 SCIE CAS CSCD 1995年第3期159-163,共5页
It is capable of giving the initial intakes of radionuclides and the assessment quantities used in radiation protection according to its measured results of radionuclides in vivo. It is accomplished by providing the ... It is capable of giving the initial intakes of radionuclides and the assessment quantities used in radiation protection according to its measured results of radionuclides in vivo. It is accomplished by providing the software of controlling, interface and internal dose estimation programs to the original iron cabin shielding whole-body counter. The preliminary application shows that its data processing is rapid and correct, and can meet the requirement of rapid internal radioactive contamination monitoring and diagnosing in case of lots of internal contamination subjects happened innuclear accident. 展开更多
关键词 Whole-body counter internal contamination monitoring internal dose Computer code
下载PDF