The nuclides inhaled during nuclear accidents usually cause internal contamination of the lungs with low activity.Although a parallel-hole imaging system,which is widely used in medical gamma cameras,has a high resolu...The nuclides inhaled during nuclear accidents usually cause internal contamination of the lungs with low activity.Although a parallel-hole imaging system,which is widely used in medical gamma cameras,has a high resolution and good image quality,owing to its extremely low detection efficiency,it remains difficult to obtain images of inhaled lung contamination.In this study,the Monte Carlo method was used to study the internal lung contamination imaging using the MPA-MURA coded-aperture collimator.The imaging system consisted of an adult male lung model,with a mosaicked,pattern-centered,and anti-symmetric MURA coded-aperture collimator model and a CsI(Tl)detector model.The MLEM decoding algorithm was used to reconstruct the internal contamination image,and the complementary imaging method was used to reduce the number of artifacts.The full width at half maximum of the I-131 point source image reconstructed by the MPAMURA coded-aperture imaging reached 2.51 mm,and the signal-to-noise ratio of the simplified respiratory tract source(I-131)image reconstructed through MPA-MURA coded-aperture imaging was 3.98 dB.Although the spatial resolution of MPA-MURA coded-aperture imaging is not as good as that of parallel-hole imaging,the detection efficiency of PMA-MURA coded-aperture imaging is two orders of magnitude higher than that of parallel-hole collimator imaging.Considering the low activity level of internal lung contamination caused by nuclear accidents,PMA-MURA coded-aperture imaging has significant potential for the development of lung contamination imaging.展开更多
A short review is given for the determination of gross alpha activity ill urine;detailed information is collected including urine mineralization,separation of alpha emitters and source preparation.
It is capable of giving the initial intakes of radionuclides and the assessment quantities used in radiation protection according to its measured results of radionuclides in vivo. It is accomplished by providing the ...It is capable of giving the initial intakes of radionuclides and the assessment quantities used in radiation protection according to its measured results of radionuclides in vivo. It is accomplished by providing the software of controlling, interface and internal dose estimation programs to the original iron cabin shielding whole-body counter. The preliminary application shows that its data processing is rapid and correct, and can meet the requirement of rapid internal radioactive contamination monitoring and diagnosing in case of lots of internal contamination subjects happened innuclear accident.展开更多
基金the Ministry of Science and Technology,People’s Republic of China(No.2012YQ180118)the National Natural Science Foundation of China(No.41874121)the Sichuan Science and Technology Program(No.2018JY0181).
文摘The nuclides inhaled during nuclear accidents usually cause internal contamination of the lungs with low activity.Although a parallel-hole imaging system,which is widely used in medical gamma cameras,has a high resolution and good image quality,owing to its extremely low detection efficiency,it remains difficult to obtain images of inhaled lung contamination.In this study,the Monte Carlo method was used to study the internal lung contamination imaging using the MPA-MURA coded-aperture collimator.The imaging system consisted of an adult male lung model,with a mosaicked,pattern-centered,and anti-symmetric MURA coded-aperture collimator model and a CsI(Tl)detector model.The MLEM decoding algorithm was used to reconstruct the internal contamination image,and the complementary imaging method was used to reduce the number of artifacts.The full width at half maximum of the I-131 point source image reconstructed by the MPAMURA coded-aperture imaging reached 2.51 mm,and the signal-to-noise ratio of the simplified respiratory tract source(I-131)image reconstructed through MPA-MURA coded-aperture imaging was 3.98 dB.Although the spatial resolution of MPA-MURA coded-aperture imaging is not as good as that of parallel-hole imaging,the detection efficiency of PMA-MURA coded-aperture imaging is two orders of magnitude higher than that of parallel-hole collimator imaging.Considering the low activity level of internal lung contamination caused by nuclear accidents,PMA-MURA coded-aperture imaging has significant potential for the development of lung contamination imaging.
文摘A short review is given for the determination of gross alpha activity ill urine;detailed information is collected including urine mineralization,separation of alpha emitters and source preparation.
文摘It is capable of giving the initial intakes of radionuclides and the assessment quantities used in radiation protection according to its measured results of radionuclides in vivo. It is accomplished by providing the software of controlling, interface and internal dose estimation programs to the original iron cabin shielding whole-body counter. The preliminary application shows that its data processing is rapid and correct, and can meet the requirement of rapid internal radioactive contamination monitoring and diagnosing in case of lots of internal contamination subjects happened innuclear accident.