A novel control scheme of active disturbance rejection internal model control(ADRIMC) is proposed to improve the anti-interference ability and robustness for the dead-time process. The active anti-interference concept...A novel control scheme of active disturbance rejection internal model control(ADRIMC) is proposed to improve the anti-interference ability and robustness for the dead-time process. The active anti-interference concept is introduced into the internal model control(IMC) by analyzing the relationship between IMC and disturbance observer control(DOB). Further, a design process of disturbance filter is presented to realize the active anti-interference ability for ADRIMC scheme. The disturbance filter is used to estimate an equivalent disturbance consisting of both external disturbances and internal disturbances caused by model mismatches.Simulation results demonstrate that the proposed method possesses a good disturbance rejection performance, though losing some partial dynamic performance. In other words, the proposed method shows a tradeoff between the dynamic performance and the system robust.展开更多
Nonlinearity is an important characteristic in electrostatic suspension system (ESS). This paper concludes the nonlinear parts in ESS, which generally result from the relationships between rotor displacement and capac...Nonlinearity is an important characteristic in electrostatic suspension system (ESS). This paper concludes the nonlinear parts in ESS, which generally result from the relationships between rotor displacement and capacitance, rotor displacement and electrostatic force, and control voltage and electrostatic force. In terms of the nonlinearities, a new control method with modified internal model control (IMC) was proposed to analyze the ESS, deduce the transfer function of the modified IMC controller in ESS, and simulate this new application in ESS. Comparing with proportional integral derivative (PID) control, IMC has only a parameter, and has better performance. As a result, IMC solves nonlinearity error well in ESS with only one uncertain parameter, and performs well when the rotor has large displacement.展开更多
Doubly-Fed Induction Generator (DFIG), with vector control applied, is widely used in Variable-Speed Constant- Frequency (VSCF) wind energy generation system and shows good performance in maximum wind energy captu...Doubly-Fed Induction Generator (DFIG), with vector control applied, is widely used in Variable-Speed Constant- Frequency (VSCF) wind energy generation system and shows good performance in maximum wind energy capture. But in two traditional vector control schemes, the equivalent stator magnetizing current is considered invariant in order to simplify the rotor current inner-loop controller. The two schemes can perform very well when the grid is in normal condition. However, when grid disturbance such as grid voltage dip or swell fault occurs, the control performance worsens, the rotor over current occurs and the Fault Ride-Through (FRT) capability of the DFIG wind energy generation system gets seriously deteriorated. An accurate DFIG model was used to deeply investigate the deficiency of the traditional vector control. The improved control schemes of two typical traditional vector control schemes used in DFIG were proposed, and simulation study of the proposed and traditional control schemes, with robust rotor current control using Internal Model Control (IMC) method, was carded out. The validity of the proposed modified schemes to control the rotor current and to improve the FRT capability of the DFIG wind energy generation system was proved by the comparison study.展开更多
Multirate multivariable predictive control system with the sampling mechanism that adjusts the plant inputs only once but detects the plant outputs several times during a period is examined. The IMC structure of the s...Multirate multivariable predictive control system with the sampling mechanism that adjusts the plant inputs only once but detects the plant outputs several times during a period is examined. The IMC structure of the system is derived, and its robust stability and zero steady state error characteristics are analyzed. A new control algorithm is developed by adding the variation of the outputs to the index performance. The simulation results show that the method is effective and has zeros steady-state error.展开更多
Since the combustion system of coal-fired boiler in thermal power plant is characterized as time varying, strongly coupled, and nonlinear, it is hard to achieve a satisfactory performance by the conventional proportio...Since the combustion system of coal-fired boiler in thermal power plant is characterized as time varying, strongly coupled, and nonlinear, it is hard to achieve a satisfactory performance by the conventional proportional integral derivative (PID) control scheme. For the characteristics of the main steam pressure in coal-fired power plant boiler, the sliding mode control system with Smith predictive structure is proposed to look for performance and robustness improvement. First, internal model control (IMC) and Smith predictor (SP) is used to deal with the time delay, and sliding mode controller (SMCr) is designed to overcome the model mismatch. Simulation results show the effectiveness of the proposed controller compared with conventional ones.展开更多
针对永磁无刷直流电机调速系统提出了一种改进的内模PI(Internal model control PI,IMC-PI)控制方法。根据内模控制原理设计出PI控制器,引入一种作用函数,将其与PI控制器串联构成改进的IMC-PI控制器。作用函数为偏差的微分表达式,其阶...针对永磁无刷直流电机调速系统提出了一种改进的内模PI(Internal model control PI,IMC-PI)控制方法。根据内模控制原理设计出PI控制器,引入一种作用函数,将其与PI控制器串联构成改进的IMC-PI控制器。作用函数为偏差的微分表达式,其阶次的选择应保证系统开环传递函数严格真实。改进IMC-PI控制可使系统的调节过程分为作用函数趋近零和保持为零的两个阶段,从而保证系统偏差按照作用函数等于零确定的轨迹趋近于零。仿真和实验结果表明方法可有效提高控制系统的性能。展开更多
基金Project(61273132)supported by the National Natural Foundation of ChinaProject(20110010010)supported by Higher School Specialized Research Fund for the Doctoral Program,China
文摘A novel control scheme of active disturbance rejection internal model control(ADRIMC) is proposed to improve the anti-interference ability and robustness for the dead-time process. The active anti-interference concept is introduced into the internal model control(IMC) by analyzing the relationship between IMC and disturbance observer control(DOB). Further, a design process of disturbance filter is presented to realize the active anti-interference ability for ADRIMC scheme. The disturbance filter is used to estimate an equivalent disturbance consisting of both external disturbances and internal disturbances caused by model mismatches.Simulation results demonstrate that the proposed method possesses a good disturbance rejection performance, though losing some partial dynamic performance. In other words, the proposed method shows a tradeoff between the dynamic performance and the system robust.
基金Weaponry Advanced FundItem of China(No51409030101JW03)
文摘Nonlinearity is an important characteristic in electrostatic suspension system (ESS). This paper concludes the nonlinear parts in ESS, which generally result from the relationships between rotor displacement and capacitance, rotor displacement and electrostatic force, and control voltage and electrostatic force. In terms of the nonlinearities, a new control method with modified internal model control (IMC) was proposed to analyze the ESS, deduce the transfer function of the modified IMC controller in ESS, and simulate this new application in ESS. Comparing with proportional integral derivative (PID) control, IMC has only a parameter, and has better performance. As a result, IMC solves nonlinearity error well in ESS with only one uncertain parameter, and performs well when the rotor has large displacement.
基金Project (No.50577056) supported by the National Natural Science Foundation of China
文摘Doubly-Fed Induction Generator (DFIG), with vector control applied, is widely used in Variable-Speed Constant- Frequency (VSCF) wind energy generation system and shows good performance in maximum wind energy capture. But in two traditional vector control schemes, the equivalent stator magnetizing current is considered invariant in order to simplify the rotor current inner-loop controller. The two schemes can perform very well when the grid is in normal condition. However, when grid disturbance such as grid voltage dip or swell fault occurs, the control performance worsens, the rotor over current occurs and the Fault Ride-Through (FRT) capability of the DFIG wind energy generation system gets seriously deteriorated. An accurate DFIG model was used to deeply investigate the deficiency of the traditional vector control. The improved control schemes of two typical traditional vector control schemes used in DFIG were proposed, and simulation study of the proposed and traditional control schemes, with robust rotor current control using Internal Model Control (IMC) method, was carded out. The validity of the proposed modified schemes to control the rotor current and to improve the FRT capability of the DFIG wind energy generation system was proved by the comparison study.
文摘Multirate multivariable predictive control system with the sampling mechanism that adjusts the plant inputs only once but detects the plant outputs several times during a period is examined. The IMC structure of the system is derived, and its robust stability and zero steady state error characteristics are analyzed. A new control algorithm is developed by adding the variation of the outputs to the index performance. The simulation results show that the method is effective and has zeros steady-state error.
基金Supported by the National Natural Science Foundation of China (61174059, 60934007, 61233004)the National Basic Research Program of China (2013CB035406)Shanghai Rising-Star Tracking Program (11QH1401300)
文摘Since the combustion system of coal-fired boiler in thermal power plant is characterized as time varying, strongly coupled, and nonlinear, it is hard to achieve a satisfactory performance by the conventional proportional integral derivative (PID) control scheme. For the characteristics of the main steam pressure in coal-fired power plant boiler, the sliding mode control system with Smith predictive structure is proposed to look for performance and robustness improvement. First, internal model control (IMC) and Smith predictor (SP) is used to deal with the time delay, and sliding mode controller (SMCr) is designed to overcome the model mismatch. Simulation results show the effectiveness of the proposed controller compared with conventional ones.
文摘针对永磁无刷直流电机调速系统提出了一种改进的内模PI(Internal model control PI,IMC-PI)控制方法。根据内模控制原理设计出PI控制器,引入一种作用函数,将其与PI控制器串联构成改进的IMC-PI控制器。作用函数为偏差的微分表达式,其阶次的选择应保证系统开环传递函数严格真实。改进IMC-PI控制可使系统的调节过程分为作用函数趋近零和保持为零的两个阶段,从而保证系统偏差按照作用函数等于零确定的轨迹趋近于零。仿真和实验结果表明方法可有效提高控制系统的性能。