BACKGROUND: Severe acute pancreatitis (SAP) is a serious disease with many complications, high mortality and poor prognosis. It is characterized by rapid deterioration and poses one of the most difficult challenges in...BACKGROUND: Severe acute pancreatitis (SAP) is a serious disease with many complications, high mortality and poor prognosis. It is characterized by rapid deterioration and poses one of the most difficult challenges in clinical practice. Previous investigations suggest that SAP is one of the main causes of intra-abdominal pressure (IAP) increase. The aim of this study was to evaluate the utility of IAP-monitoring in predicting the severity and prognosis of SAP. METHODS: Eighty-nine patients with SAP who had been treated from February 2001 to December 2005 were studied. Since bladder pressure accurately reflects IAP, we measured it instead of IAP. Bladder pressure was measured at the time of admission and every 12 hours in the course of the disease, 9 consecutive times in all. The APACHE II scores of all patients were obtained within 24 hours after admission. According to a maximum bladder pressure <10 cmH(2)O, all patients were divided into two groups, mildly-elevated and severely-elevated. Mortality and mean APACHE II scores in the two groups were calculated. In addition, the mean bladder pressure and APACHE II scores in survivors were compared with those in deaths. RESULTS: Sixty-eight of the 89 patients were in the severely-elevated group. Mortality and mean APACHE II scores in this group were much higher than those in the mildly-elevated group (mortality, 39.71% vs. 9.52%; mean APACHE II score, 23.15 +/- 7.42 vs. 15.95 +/- 5.35, P<0.01). The mean bladder pressures and APACHE II scores in deaths were significantly greater than those in survivors (mean bladder pressure, 14.1 +/- 3.8 vs. 9.2 +/- 2.3 cmH(2)O, P<0.01; mean APACHE II score, 27.83 +/- 4.87 vs. 18.37 +/- 6.74, P<0.01). CONCLUSION: It is suggested that IAP may be used as a marker of the severity and prognosis of SAP.展开更多
BACKGROUND: Noninvasive monitoring of intra-abdominal pressure(IAP) by measuring abdominal wall tension(AWT) was effective and feasible in previous postmortem and animal studies. This study aimed to investigate the fe...BACKGROUND: Noninvasive monitoring of intra-abdominal pressure(IAP) by measuring abdominal wall tension(AWT) was effective and feasible in previous postmortem and animal studies. This study aimed to investigate the feasibility of the AWT method for noninvasively monitoring IAP in the intensive care unit(ICU).METHODS: In this prospective study, we observed patients with detained urethral catheters in the ICU of Shanghai Tenth People's Hospital between April 2011 and March 2013. The correlation between AWT and urinary bladder pressure(UBP) was analyzed by linear regression analysis. The effects of respiratory and body position on AWT were evaluated using the paired samples t test, whereas the effects of gender and body mass index(BMI) on baseline AWT(IAP<12 mm Hg) were assessed using one-way analysis of variance.RESULTS: A total of 51 patients were studied. A significant linear correlation was observed between AWT and UBP(R=0.986, P<0.01); the regression equation was Y=–1.369+9.57X(P<0.01). There were signif icant differences among the different respiratory phases and body positions(P<0.01). However, gender and BMI had no signif icant effects on baseline AWT(P=0.457 and 0.313, respectively).CONCLUSIONS: There was a signif icant linear correlation between AWT and UBP and respiratory phase, whereas body position had signif icant effects on AWT but gender and BMI did not. Therefore, AWT could serve as a simple, rapid, accurate, and important method to monitor IAP in critically ill patients.展开更多
The potential of monitoring the movement of typhoons using the precipitable water vapor(PWV) has been confirmed. However, monitoring the movement of typhoon is focused on PWV, making it difficult to describe the movem...The potential of monitoring the movement of typhoons using the precipitable water vapor(PWV) has been confirmed. However, monitoring the movement of typhoon is focused on PWV, making it difficult to describe the movement of a typhoon in detail minutely and resulting in insufficient accuracy. Hence,based on PWV and meteorological data, we propose an improved typhoon monitoring mode. First, the European Centre for Medium-Range Weather Forecasts Reanalysis 5-derived PWV(ERA5-PWV) and the Global Navigation Satellite System-derived PWV(GNSS-PWV) were compared with the reference radiosonde PWV(RS-PWV). Then, using the PWV and atmospheric parameters derived from ERA5, we discussed the anomalous variations of PWV, pressure(P), precipitation, and wind speed during different typhoons. Finally, we compiled a list of critical factors related to typhoon movement, PWV and P. We developed an improved multi-factor typhoon monitoring mode(IMTM) with different models(i.e.,IMTM-I and IMTM-II) in different cases with a higher density of GNSS observation or only Numerical Weather Prediction(NWP) data. The IMTM was evaluated through the reference movement speeds of HATO and Mangkhut from the China Meteorological Observatory Typhoon Network(CMOTN). The results show that the root mean square(RMS) of the IMTM-I is 1.26 km/h based on ERA5-P and ERA5-PWV,and the absolute bias values are mostly within 2 km/h. Compared with the models considering the single factor ERA5-P/ERA5-PWV, the RMS of the IMTM-I is improved by 26.3% and 38.5%, respectively. The IMTM-II model manifests a residual of only 0.35 km/h. Compared with the single-factor model based on GNSS-PWV/P, the residual of the IMTM-II model is reduced by 90.8% and 84.1%, respectively. These results propose that the typhoon movement monitoring approach combining PWV and P has evident advantages over the single-factor model and is expected to supplement traditional typhoon monitoring.展开更多
The phase change of CO_(2) has a significant bearing on the siting, injection, and monitoring of storage. The phase state of CO_(2) is closely related to pressure. In the process of seismic exploration, the informatio...The phase change of CO_(2) has a significant bearing on the siting, injection, and monitoring of storage. The phase state of CO_(2) is closely related to pressure. In the process of seismic exploration, the information of formation pressure can be response in the seismic data. Therefore, it is possible to monitor the formation pressure using time-lapse seismic method. Apart from formation pressure, the information of porosity and CO_(2) saturation can be reflected in the seismic data. Here, based on the actual situation of the work area, a rockphysical model is proposed to address the feasibility of time-lapse seismic monitoring during CO_(2) storage in the anisotropic formation. The model takes into account the formation pressure, variety minerals composition, fracture, fluid inhomogeneous distribution, and anisotropy caused by horizontal layering of rock layers(or oriented alignment of minerals). From the proposed rockphysical model and the well-logging, cores and geological data at the target layer, the variation of P-wave and S-wave velocity with formation pressure after CO_(2) injection is calculated. And so are the effects of porosity and CO_(2) saturation. Finally, from anisotropic exact reflection coefficient equation, the reflection coefficients under different formation pressures are calculated. It is proved that the reflection coefficient varies with pressure. Compared with CO_(2) saturation, the pressure has a greater effect on the reflection coefficient. Through the convolution model, the seismic record is calculated. The seismic record shows the difference with different formation pressure. At present, in the marine CO_(2) sequestration monitoring domain, there is no study involving the effect of formation pressure changes on seismic records in seafloor anisotropic formation. This study can provide a basis for the inversion of reservoir parameters in anisotropic seafloor CO_(2) reservoirs.展开更多
Fully mechanized solid backfill mining(FMSBM) technology adopts dense backfill body to support the roof. Based on the distinguishing characteristics and mine pressure control principle in this technology, the basic pr...Fully mechanized solid backfill mining(FMSBM) technology adopts dense backfill body to support the roof. Based on the distinguishing characteristics and mine pressure control principle in this technology, the basic principles and methods for mining pressure monitoring were analyzed and established. And the characteristics of overburden strata movement were analyzed by monitoring the support resistance of hydraulic support, the dynamic subsidence of immediate roof, the stress of backfill body, the front abutment pressure, and the mass ratio of cut coal to backfilled materials. On-site strata behavior measurements of 7403 W solid backfilling working face in Zhai Zhen Coal Mine show that the backfill body can effectively support the overburden load, obviously control the overburden strata movement, and weaken the strata behaviors distinctly. Specific performances are as follows. The support resistance decreases obviously; the dynamic subsidence of immediate roof keeps consistent to the variation of backfill body stress, and tends to be stable after the face retreating to 120-150 m away from the cut. The peak value of front abutment pressure arises at 5-12 m before the operating face, and mass ratio is greater than the designed value of 1.15, which effectively ensures the control of strata movement. The research results are bases for intensively studying basic theories of solid backfill mining strata behaviors and its control, and provide theoretical guidance for engineering design in FMSBM.展开更多
Monitoring tire pressure of cars and signaling abnormal conditions is an important means to prevent deadly accidents. Large achievements have been gained, especially in direct tire pressure monitoring system(TPMS). ...Monitoring tire pressure of cars and signaling abnormal conditions is an important means to prevent deadly accidents. Large achievements have been gained, especially in direct tire pressure monitoring system(TPMS). But there has been rarely research on indirect TPMS in the world. In China, the research on indirect TPMS is almost lacking. The international research on the indirect monitoring tire pressure method is mainly based on measuring and comparing the rotating speed of wheels. But it is very difficult to measure wheel rotating speed accurately because of the influence of many random factors. In this paper, the authors propose a new method in which the tire pressure can be monitored indirectly. This method can be used for tire calibration, wheel speed frequency standardization, wheel speed frequency comparison, and abnormal tire pressure determination. The pulse frequencies from wheel speed sensors of ABS are used to indicate tire deformation. Because the frequency has a relationship with tire deformation, the tire deformation reflects the tire pressure. Small sample statistics is used in the new method to increase the accuracy, and the experimental samples using the principle of the new method have been made and tested. The result of vehicle tests on road demonstrates that the method is efficient and accurate to monitor tire pressure. The research has positive potential for developing products.展开更多
Elevated intra-abdominal pressure(IAP)is a known cause of increased morbidity and mortality among critically ill patients.Intra-abdominal hypertension(IAH)and abdominal compartment syndrome can lead to rapid deteriora...Elevated intra-abdominal pressure(IAP)is a known cause of increased morbidity and mortality among critically ill patients.Intra-abdominal hypertension(IAH)and abdominal compartment syndrome can lead to rapid deterioration of organ function and the development of multiple organ failure.Raised IAP affects every system and main organ in the human body.Even marginally sustained IAH results in malperfusion and may disrupt the process of recovery.Yet,despite being so common,this potentially lethal condition often goes unnoticed.In 2004,the World Society of the Abdominal Compartment Syndrome,an international multidisciplinary consensus group,was formed to provide unified definitions,improve understanding and promote research in this field.Simple,reliable and nearly costless standardized methods of non-invasive measurement and monitoring of bladder pressure allow early recognition of IAH and timely optimized management.The correct,structured approach to treatment can have a striking effect and fully restore homeostasis.In recent years,significant progress has been made in this area with the contribution of surgeons,internal medicine specialists and anesthesiologists.Our review focuses on recent advances in order to present the complex underlying pathophysiology and guidelines concerning diagnosis,monitoring and treatment of this life-threatening condition.展开更多
Background Fall injuries are common among the elderly. The aim of this study was to investigate whether blood-pressure patterns, as measured by 24-h ambulatory blood pressure monitoring (ABPM), or intensification of...Background Fall injuries are common among the elderly. The aim of this study was to investigate whether blood-pressure patterns, as measured by 24-h ambulatory blood pressure monitoring (ABPM), or intensification of antihypertensive therapy following the 24-h ABPM, may be associated with fall injuries in hypertensive elderly patients. Methods In a retrospective study, community-based elderly patients (age ≥ 70 years) who were referred to 24-h ABPM were evaluated for fall injuries within one-year post-ABPM. We compared the clinical characteristics, 24-h ABPM patterns and the intensification of hypertensive therapy following 24-h ABPM, between patients with and without a fall injury. Results Overall 1032 hypertensive elderly patients were evaluated. Fifty-five (5.3%) had a fall injury episode in the year following ABPM. Patients with a fall injury were significantly older, and with higher rates of previous falls. Lower 24-h diastolic blood-pressure (67.3 ± 7.6 vs. 70.7 ± 8.8 mmHg; P 〈 0.005) and increased pulse-pressure (74.7 ± 14.3 vs. 68.3 ± 13.7 mmHg; P 〈 0.005), were found in the patients with a fall injury, compared to those without a fall injury. After adjustment for age, gender, diabetes mellitus and previous falls, lower diastolic blood-pressure and increased pulse-pressure were independent predictors of fall injury. Intensification of antihypertensive treatment following the 24-h ABPM was not associated with an increased rate of fall injury. Conclusions Low diastolic blood-pressure and increased pulse-pressure in 24-h ABPM were associated with an increased risk of fall injury in elderly hypertensive patients. Intensification of antihypertensive treatment following 24-h ABPM was not associated with an increased risk of fall injury.展开更多
In accordance with the trans-lamina cribrosa pressure difference theory, decreasing the trans-lamina cribrosa pressure difference can re- lieve glaucomatous optic neuropathy. Increased intracranial pressure can also r...In accordance with the trans-lamina cribrosa pressure difference theory, decreasing the trans-lamina cribrosa pressure difference can re- lieve glaucomatous optic neuropathy. Increased intracranial pressure can also reduce optic nerve damage in glaucoma patients, and a safe, effective and noninvasive way to achieve this is by increasing the intra-abdominal pressure. The purpose of this study was to observe the changes in orbital subarachnoid space width and intraocular pressure at elevated intra-abdominal pressure. An inflatable abdominal belt was tied to each of 15 healthy volunteers, aged 22-30 years (12 females and 3 males), at the navel level, without applying pressure to the abdomen, before they laid in the magnetic resonance imaging machine. The baseline orbital subarachnoid space width around the optic nerve was measured by magnetic resonance imaging at 1, 3, 9, and 15 mm behind the globe. The abdominal belt was inflated to increase the pressure to 40 mmHg (1 mmHg = 0.133 kPa), then the orbital subarachnoid space width was measured every 10 minutes for 2 hours. After removal of the pressure, the measurement was repeated 10 and 20 minutes later. In a separate trial, the intraocular pressure was measured for all the subjects at the same time points, before, during and after elevated intra-abdominal pressure. Results showed that the baseline mean orbital subarachnoid space width was 0.88 + 0.1 mm (range: 0.77-1.05 mm), 0.77 + 0.11 mm (range: 0.60-0.94 mm), 0.70 + 0.08 mm (range: 0.62-0.80 ram), and 0.68 _+ 0.08 mm (range: 0.57-0.77 mm) at 1, 3, 9, and 15 mm behind the globe, respectively. During the elevated intra-abdominal pressure, the orbital subarachnoid space width increased from the baseline and dilation of the optic nerve sheath was significant at 1, 3 and 9 mm behind the globe. After decompression of the abdominal pressure, the orbital subarachnoid space width normalized and returned to the baseline value. There was no significant difference in the intraocular pressure before, during and after the intra-abdominal pressure elevation. These results verified that the increased intra-abdominal pressure widens the orbital subarachnoid space in this acute trial, but does not alter the intraocular pressure, indicating that intraocular pressure is not affected by rapid increased in- tra-abdominal pressure. This study was registered in the Chinese Clinical Trial Registry (registration number: ChiCTR-ONRC-14004947).展开更多
AIM: To determine the influence of intra-abdominal pressure(IAP) on respiratory function after surgical repair of ventral hernia and to compare two different methods of IAP measurement during the perioperative period....AIM: To determine the influence of intra-abdominal pressure(IAP) on respiratory function after surgical repair of ventral hernia and to compare two different methods of IAP measurement during the perioperative period. METHODS: Thirty adult patients after elective repair of ventral hernia were enrolled into this prospective study.IAP monitoring was performed via both a balloontipped nasogastric probe [intragastric pressure(IGP), Ci MON, Pulsion Medical Systems, Munich, Germany] and a urinary catheter [intrabladder pressure(IBP), Uno Meter Abdo-Pressure Kit, Uno Medical, Denmark] on five consecutive stages:(1) after tracheal intubation(AI);(2) after ventral hernia repair;(3) at the end of surgery;(4) during spontaneous breathing trial through the endotracheal tube; and(5) at 1 h after tracheal extubation. The patients were in the complete supine position during all study stages.RESULTS: The IAP(measured via both techniques) increased on average by 12% during surgery compared to AI(P < 0.02) and by 43% during spontaneous breathing through the endotracheal tube(P < 0.01). In parallel, the gradient between РаСО2 and Et CO2 [Р(а-et)CO2] rose significantly, reaching a maximum during the spontaneous breathing trial. The PаO2/Fi O2 decreased by 30% one hour after tracheal extubation(P = 0.02). The dynamic compliance of respiratory system reduced intraoperatively by 15%-20%(P < 0.025). At all stages, we observed a significant correlation between IGP and IBP(r = 0.65-0.81, P < 0.01) with a mean bias varying from-0.19 mm Hg(2SD 7.25 mm Hg) to-1.06 mm Hg(2SD 8.04 mm Hg) depending on the study stage. Taking all paired measurements together(n = 133), the median IGP was 8.0(5.5-11.0) mm Hg and the median IBP was 8.8(5.8-13.1) mm Hg. The overall r2 value( n = 30) was 0.76(P < 0.0001). Bland and Altman analysis showed an overall bias for the mean values per patient of 0.6 mm Hg(2SD 4.2 mm Hg) with percentage error of 45.6%. Looking at changes in IAP between the different study stages, we found an excellent concordance coefficient of 94.9% comparing IBP and IGP( n = 117).CONCLUSION: During ventral hernia repair, the IAP rise is accompanied by changes in Р(а-et)CO2 and PаO2/Fi O2-ratio. Estimation of IAP via IGP or IBP demonstrated excellent concordance.展开更多
A proof-of-concept indirect tire-pressure monitoring system is developed using artificial neural networks to identify the tire pressure of a vehicle tire.A quarter-car model was developed with MATLAB and Simulink to g...A proof-of-concept indirect tire-pressure monitoring system is developed using artificial neural networks to identify the tire pressure of a vehicle tire.A quarter-car model was developed with MATLAB and Simulink to generate simulated accelerometer output data.Simulation data are used to train and evaluate a recurrent neural network with long short-term memory blocks(RNN-LSTM)and a convolutional neural network(CNN)developed in Python with Tensorflow.Bayesian Optimization via SigOpt was used to optimize training and model parameters.The predictive accuracy and training speed of the two models with various parameters are compared.Finally,future work and improvements are discussed.展开更多
Despite an increasing popularity of home blood pressure monitoring (HBPM) over the last few decades, little is known about HBPM use among hypertensive patients in the rural areas. A cross-sectional survey including 31...Despite an increasing popularity of home blood pressure monitoring (HBPM) over the last few decades, little is known about HBPM use among hypertensive patients in the rural areas. A cross-sectional survey including 318 hypertensive patients was conducted in a rural community in Beijing, China, in 2012. Participants were mainly recruited from a community health clinic and completed the questionnaires assessing HBPM usage. Binary logistic regression models were used for the analysis of medication adherence with age, gender, level of education marital status, perceived health status, duration of hypertension, HBPM use, and frequency of performing BP measurement. Among the total population, 78 (24.5%) reported currently use of HBPM. Only 5.1% of the HBPM users cited doctor’s advice as the reason for using HBPM. Analysis of the risk factors of poor medication adherence by multivariable modeling indicated significant associations between the duration of hypertension (adjusted OR, 3.31;95% CI, 1.91-5.72;P 01), frequency of performing BP measurements (adjusted OR, 2.33;95% CI, 1.42-3.83;展开更多
This article is a review of 25 publications on ambulatory blood pressure monitoring(ABPM) and the importance of its results in everyday clinical practice. These studies, published in 2008-2011, were selected from the ...This article is a review of 25 publications on ambulatory blood pressure monitoring(ABPM) and the importance of its results in everyday clinical practice. These studies, published in 2008-2011, were selected from the Scopus database, but are also available in Pubmed. They were prepared by researchers from around the world, concerned with the problems of proper control of blood pressure(BP), and of abnormalities in the circadian pattern of BP in patients with arterial hypertension, diabetes mellitus or renal failure. In the first part of this article, I analyse publications focused on some nuances in the methodology of ABPM and recommend ways to avoid some traps, related not only to the individual patient but also to the device used and the technical staff. The next section is devoted to the advantages of ABPM as a diagnostic tool which enables clinicians to learn about patients' BP during sleep, and emphasizes the practical implications of this information for so-called chronotherapy. This section also presents some new studies on the prognostic value of ABPM in patients with cardiovascular(CV) risk. Some recent articles on the results of various methods of pharmacological treatment of arterial hypertension in different agegroups are then described. The observations presented in this article may be helpful not only for researchers interested in the chronobiology of the CV system, but also for general practitioners using ABPM.展开更多
Heart failure (HF) is an emerging epidemic associate with significant morbidity, mortality, and health care expenditure. Although there were major advances in pharmacologic and device based therapies for the managemen...Heart failure (HF) is an emerging epidemic associate with significant morbidity, mortality, and health care expenditure. Although there were major advances in pharmacologic and device based therapies for the management of HF, mortality of this condition remains high. Accurate monitoring of HF patients for exacerbations is very important to reduce recurrent hospitalizations and its associated complications. With the failure of clinical signs, tele-monitoring, and laboratory bio-markers to function as early markers of HF exacerbations, more sophisticated techniques were sought to accurately predict the circulatory status in HF patients in order to execute timely pharmacological intervention to reduce frequent hospitalizations. CardioMEMS<sup>TM</sup> (St. Jude Medical, Inc., Saint Paul, Minnesota) is an implantable, wireless pulmonary arterial pressure (PAP) monitoring system which transmits the patient’s continuous PAPs to the treating health care provider in the ambulatory setting. PAP-guided medical therapy modification has been shown to significantly reduce HF-related hospitalization and overall mortality. In advanced stages of HF, wireless access to hemodynamic information correlated with earlier left ventricular assist device implantation and shorter time to heart transplantation.展开更多
This paper presents an RF energy harvesting system for wireless intraocular pressure monitoring applications.The system consists of an implantable antenna and a rectifier.A new sizing strategy is adopted to optimize t...This paper presents an RF energy harvesting system for wireless intraocular pressure monitoring applications.The system consists of an implantable antenna and a rectifier.A new sizing strategy is adopted to optimize the conversion efficiency of the rectifier,and the design principle of an implantable antenna is introduced from material selection and structure design.Results from testing demonstrate that the antenna gain is about-20 dBi and the rectifier's maximum total conversion efficiency which contains match efficiency and rectifying efficiency is 47.18%under the implementation of0.18μm standard CMOS process.The maximum power obtained from the proposed system is 8μW when the power density of electromagnetic wave is lower than the national standard 40μW/cm^2 at915 MHz,which is enough to power the intraocular pressure monitoring system.展开更多
This paper presents the tire pressure monitoring system (TPMS) by using the system on chip (SoC) mixed signals with the help of Bluetooth transmission and in advantage of low power consumption design. This is to monit...This paper presents the tire pressure monitoring system (TPMS) by using the system on chip (SoC) mixed signals with the help of Bluetooth transmission and in advantage of low power consumption design. This is to monitor the variations in temperature and pressure of the vehicle’s tire, and the TPMS system is involved. It improves the driver’s safety by automatically detecting the tire pressure and temperature and then warning signal is sent to driver to take a measure, which prevents from accident. The proposed system of tire pressure monitoring system using SoC increases the speed of indication time to the driver by using mixed signals. The inflation of the tire can be avoided by preventing from high temperature and high pressure. Limitation of temperature and pressure in the previous system is also elongated i.e. temperature from 40℃ to 125℃ and pressure from 0 to 750 Kpa. Sensors, wireless communication (Bluetooth dongle) and SoC unit are used to design the low power TPMS. Quantitative results are taken and the analogy between temperature and pressure is also verified. The tested results proved by need of the practical system. Signal conditioning voltage and SoC unit is the trace for low power design TPMS. Finally, the performance of the system is tested and executed by using proteus software given as a real time application.展开更多
Glaucoma is a neurodegenerative condition that is the leading cause of irreversible blindness worldwide. Elevated intraocular pressure (IOP) is the main risk factor for the development and progression of the disease. ...Glaucoma is a neurodegenerative condition that is the leading cause of irreversible blindness worldwide. Elevated intraocular pressure (IOP) is the main risk factor for the development and progression of the disease. Methods to lower IOP remain the first line treatments for the condition. Current methods of IOP measurement do not permit temporary noninvasive monitoring 24-hour IOP on a periodic basis. Ongoing research will in time provide a means of developing a device that will enable continuous or temporary monitoring of IOP. At present a device suitable for clinical use is not yet available.This review contains a description of different devices currently in development for measuring IOP: soft contact lens, LC resonant circuits and on-chip sensing devices. All of them use application-specific integrated circuits (ASICS) to process the measured signals and send them to recording devices. Soft contact lens devices are based on an embedded strain gauge, LC circuits vary their resonance frequency depending on the intraocular pressure (IOP) and, finally, on-chip sensing devices include an integrated microelectromechanical sensor (MEMS). MEMS are capacitors whose capacity varies with IOP. These devices allow for an accurate IOP measurement (up to +/– 0.2 mm Hg) with high sampling rates (up to 1 sample/min) and storing 1 week of raw data. All of them operate in an autonomous way and even some of them are energetically independent.展开更多
Management of hypertension (HTN) largely relies on proper and accurate measurement of blood pressure (BP). Even following the criteria for HTN diagnosis defined in the Fourth report on high BP in children and adolesce...Management of hypertension (HTN) largely relies on proper and accurate measurement of blood pressure (BP). Even following the criteria for HTN diagnosis defined in the Fourth report on high BP in children and adolescents, inaccurate diagnosis and misdiagnosis can occur with white coat effect and masked HTN. The use of Ambulatory Blood Pressure Monitoring (ABPM) has been increasing in pediatrics in the last 20 years. The main use of ABPM is to differentiate between sustained HTN and white coat HTN in patients who have elevated casual BP measurements and to detect masked HTN in high risk patients. ABPM is most useful in patients with casual BP within 20% of the 95th percentile for age, gender, and height. This report will highlight the use of ABPM in the evaluation of elevated BP and management of HTN in pediatrics. The discussion includes a review of various non-invasive BP measuring techniques, a description of ABPM and ABPM-unique data and diagnoses, updated ABPM clinical data more specific to pediatrics, its use in HTN clinical trials, and future outlook and direction of ABPM in pediatrics.展开更多
Objectives: To study the ambulatory measured blood pressure (ABPM) profile in normotensive patients with mild cognitive impairment (MCI). Patients and Methods: The study was designed as a case control study including ...Objectives: To study the ambulatory measured blood pressure (ABPM) profile in normotensive patients with mild cognitive impairment (MCI). Patients and Methods: The study was designed as a case control study including 50male patients with mild cognitive impairment in the age group of 30 - 50 years old. The control group included 30 volunteers with no cognitive impairment and in the same age group (30 - 50 years old) and same gender. Mini-mental estate examination, office and ABP monitoring (ABPM) and brain MRI scans were done for cases and controls. Results: Thirty patients (60%) with MCI revealed a non-dipper blood pressure pattern. Sleeping systolic blood pressure and sleeping systolic load were significantly higher in patients with MCI than in normal volunteers (p = 0.01). MRI brain showed more white matter lesions (WMLs) in patients with MCI than in normal volunteers;however, this didn’t reach significance level (p = 0.056). Conclusion: MCI in normotensive young adult patients could reflect an abnormal circadian blood pressure rhythm. Ambulatory blood pressure monitoring could be an essential investigation in young adult MCI patients.展开更多
Upon the analysis of the interior and exterior pressures observed on the double-tubbing shaftwalls of the West Ventilation Shaft in Xieqiao Coal Mine of Huainan, deep-going investigations are made into foreign loads o...Upon the analysis of the interior and exterior pressures observed on the double-tubbing shaftwalls of the West Ventilation Shaft in Xieqiao Coal Mine of Huainan, deep-going investigations are made into foreign loads on the shaftwalls of thes kind at each working stage and into the distributiona patterns of interior pressures. As a result, a calculation model is established for forecasting exterior loads on the shaftwalls by using the grey theory.展开更多
文摘BACKGROUND: Severe acute pancreatitis (SAP) is a serious disease with many complications, high mortality and poor prognosis. It is characterized by rapid deterioration and poses one of the most difficult challenges in clinical practice. Previous investigations suggest that SAP is one of the main causes of intra-abdominal pressure (IAP) increase. The aim of this study was to evaluate the utility of IAP-monitoring in predicting the severity and prognosis of SAP. METHODS: Eighty-nine patients with SAP who had been treated from February 2001 to December 2005 were studied. Since bladder pressure accurately reflects IAP, we measured it instead of IAP. Bladder pressure was measured at the time of admission and every 12 hours in the course of the disease, 9 consecutive times in all. The APACHE II scores of all patients were obtained within 24 hours after admission. According to a maximum bladder pressure <10 cmH(2)O, all patients were divided into two groups, mildly-elevated and severely-elevated. Mortality and mean APACHE II scores in the two groups were calculated. In addition, the mean bladder pressure and APACHE II scores in survivors were compared with those in deaths. RESULTS: Sixty-eight of the 89 patients were in the severely-elevated group. Mortality and mean APACHE II scores in this group were much higher than those in the mildly-elevated group (mortality, 39.71% vs. 9.52%; mean APACHE II score, 23.15 +/- 7.42 vs. 15.95 +/- 5.35, P<0.01). The mean bladder pressures and APACHE II scores in deaths were significantly greater than those in survivors (mean bladder pressure, 14.1 +/- 3.8 vs. 9.2 +/- 2.3 cmH(2)O, P<0.01; mean APACHE II score, 27.83 +/- 4.87 vs. 18.37 +/- 6.74, P<0.01). CONCLUSION: It is suggested that IAP may be used as a marker of the severity and prognosis of SAP.
基金supported by a grant from Shanghai Municipal Health Bureau Program(2009143)
文摘BACKGROUND: Noninvasive monitoring of intra-abdominal pressure(IAP) by measuring abdominal wall tension(AWT) was effective and feasible in previous postmortem and animal studies. This study aimed to investigate the feasibility of the AWT method for noninvasively monitoring IAP in the intensive care unit(ICU).METHODS: In this prospective study, we observed patients with detained urethral catheters in the ICU of Shanghai Tenth People's Hospital between April 2011 and March 2013. The correlation between AWT and urinary bladder pressure(UBP) was analyzed by linear regression analysis. The effects of respiratory and body position on AWT were evaluated using the paired samples t test, whereas the effects of gender and body mass index(BMI) on baseline AWT(IAP<12 mm Hg) were assessed using one-way analysis of variance.RESULTS: A total of 51 patients were studied. A significant linear correlation was observed between AWT and UBP(R=0.986, P<0.01); the regression equation was Y=–1.369+9.57X(P<0.01). There were signif icant differences among the different respiratory phases and body positions(P<0.01). However, gender and BMI had no signif icant effects on baseline AWT(P=0.457 and 0.313, respectively).CONCLUSIONS: There was a signif icant linear correlation between AWT and UBP and respiratory phase, whereas body position had signif icant effects on AWT but gender and BMI did not. Therefore, AWT could serve as a simple, rapid, accurate, and important method to monitor IAP in critically ill patients.
基金supported by the Guangxi Natural Science Foundation of China (2020GXNSFBA297145,Guike AD23026177)the Foundation of Guilin University of Technology(GUTQDJJ6616032)+3 种基金Guangxi Key Laboratory of Spatial Information and Geomatics (21-238-21-05)the National Natural Science Foundation of China (42064002,42004025,42074035,42204006)the Innovative Training Program Foundation (202210596015,202210596402)the Open Fund of Hubei Luojia Laboratory(gran 230100020,230100019)。
文摘The potential of monitoring the movement of typhoons using the precipitable water vapor(PWV) has been confirmed. However, monitoring the movement of typhoon is focused on PWV, making it difficult to describe the movement of a typhoon in detail minutely and resulting in insufficient accuracy. Hence,based on PWV and meteorological data, we propose an improved typhoon monitoring mode. First, the European Centre for Medium-Range Weather Forecasts Reanalysis 5-derived PWV(ERA5-PWV) and the Global Navigation Satellite System-derived PWV(GNSS-PWV) were compared with the reference radiosonde PWV(RS-PWV). Then, using the PWV and atmospheric parameters derived from ERA5, we discussed the anomalous variations of PWV, pressure(P), precipitation, and wind speed during different typhoons. Finally, we compiled a list of critical factors related to typhoon movement, PWV and P. We developed an improved multi-factor typhoon monitoring mode(IMTM) with different models(i.e.,IMTM-I and IMTM-II) in different cases with a higher density of GNSS observation or only Numerical Weather Prediction(NWP) data. The IMTM was evaluated through the reference movement speeds of HATO and Mangkhut from the China Meteorological Observatory Typhoon Network(CMOTN). The results show that the root mean square(RMS) of the IMTM-I is 1.26 km/h based on ERA5-P and ERA5-PWV,and the absolute bias values are mostly within 2 km/h. Compared with the models considering the single factor ERA5-P/ERA5-PWV, the RMS of the IMTM-I is improved by 26.3% and 38.5%, respectively. The IMTM-II model manifests a residual of only 0.35 km/h. Compared with the single-factor model based on GNSS-PWV/P, the residual of the IMTM-II model is reduced by 90.8% and 84.1%, respectively. These results propose that the typhoon movement monitoring approach combining PWV and P has evident advantages over the single-factor model and is expected to supplement traditional typhoon monitoring.
文摘The phase change of CO_(2) has a significant bearing on the siting, injection, and monitoring of storage. The phase state of CO_(2) is closely related to pressure. In the process of seismic exploration, the information of formation pressure can be response in the seismic data. Therefore, it is possible to monitor the formation pressure using time-lapse seismic method. Apart from formation pressure, the information of porosity and CO_(2) saturation can be reflected in the seismic data. Here, based on the actual situation of the work area, a rockphysical model is proposed to address the feasibility of time-lapse seismic monitoring during CO_(2) storage in the anisotropic formation. The model takes into account the formation pressure, variety minerals composition, fracture, fluid inhomogeneous distribution, and anisotropy caused by horizontal layering of rock layers(or oriented alignment of minerals). From the proposed rockphysical model and the well-logging, cores and geological data at the target layer, the variation of P-wave and S-wave velocity with formation pressure after CO_(2) injection is calculated. And so are the effects of porosity and CO_(2) saturation. Finally, from anisotropic exact reflection coefficient equation, the reflection coefficients under different formation pressures are calculated. It is proved that the reflection coefficient varies with pressure. Compared with CO_(2) saturation, the pressure has a greater effect on the reflection coefficient. Through the convolution model, the seismic record is calculated. The seismic record shows the difference with different formation pressure. At present, in the marine CO_(2) sequestration monitoring domain, there is no study involving the effect of formation pressure changes on seismic records in seafloor anisotropic formation. This study can provide a basis for the inversion of reservoir parameters in anisotropic seafloor CO_(2) reservoirs.
基金Project(SKLCRSM12X01)supported by State Key Laboratory of Coal Resources and Safe Mining,China University of Mining&TechnologyProject(2014ZDPY02)supported by the Fundamental Research Funds for the Central Universities,ChinaProject(CXLX13_951)supported by the Research Innovation Program for College Graduates of Jiangsu Province,China
文摘Fully mechanized solid backfill mining(FMSBM) technology adopts dense backfill body to support the roof. Based on the distinguishing characteristics and mine pressure control principle in this technology, the basic principles and methods for mining pressure monitoring were analyzed and established. And the characteristics of overburden strata movement were analyzed by monitoring the support resistance of hydraulic support, the dynamic subsidence of immediate roof, the stress of backfill body, the front abutment pressure, and the mass ratio of cut coal to backfilled materials. On-site strata behavior measurements of 7403 W solid backfilling working face in Zhai Zhen Coal Mine show that the backfill body can effectively support the overburden load, obviously control the overburden strata movement, and weaken the strata behaviors distinctly. Specific performances are as follows. The support resistance decreases obviously; the dynamic subsidence of immediate roof keeps consistent to the variation of backfill body stress, and tends to be stable after the face retreating to 120-150 m away from the cut. The peak value of front abutment pressure arises at 5-12 m before the operating face, and mass ratio is greater than the designed value of 1.15, which effectively ensures the control of strata movement. The research results are bases for intensively studying basic theories of solid backfill mining strata behaviors and its control, and provide theoretical guidance for engineering design in FMSBM.
基金supported by the Opening Foundation of State Key Laboratory of Automobile Safety and Energy,Tsinghua University,China(Grant No. KF2005-11,Grant No.KF2007-09)
文摘Monitoring tire pressure of cars and signaling abnormal conditions is an important means to prevent deadly accidents. Large achievements have been gained, especially in direct tire pressure monitoring system(TPMS). But there has been rarely research on indirect TPMS in the world. In China, the research on indirect TPMS is almost lacking. The international research on the indirect monitoring tire pressure method is mainly based on measuring and comparing the rotating speed of wheels. But it is very difficult to measure wheel rotating speed accurately because of the influence of many random factors. In this paper, the authors propose a new method in which the tire pressure can be monitored indirectly. This method can be used for tire calibration, wheel speed frequency standardization, wheel speed frequency comparison, and abnormal tire pressure determination. The pulse frequencies from wheel speed sensors of ABS are used to indicate tire deformation. Because the frequency has a relationship with tire deformation, the tire deformation reflects the tire pressure. Small sample statistics is used in the new method to increase the accuracy, and the experimental samples using the principle of the new method have been made and tested. The result of vehicle tests on road demonstrates that the method is efficient and accurate to monitor tire pressure. The research has positive potential for developing products.
文摘Elevated intra-abdominal pressure(IAP)is a known cause of increased morbidity and mortality among critically ill patients.Intra-abdominal hypertension(IAH)and abdominal compartment syndrome can lead to rapid deterioration of organ function and the development of multiple organ failure.Raised IAP affects every system and main organ in the human body.Even marginally sustained IAH results in malperfusion and may disrupt the process of recovery.Yet,despite being so common,this potentially lethal condition often goes unnoticed.In 2004,the World Society of the Abdominal Compartment Syndrome,an international multidisciplinary consensus group,was formed to provide unified definitions,improve understanding and promote research in this field.Simple,reliable and nearly costless standardized methods of non-invasive measurement and monitoring of bladder pressure allow early recognition of IAH and timely optimized management.The correct,structured approach to treatment can have a striking effect and fully restore homeostasis.In recent years,significant progress has been made in this area with the contribution of surgeons,internal medicine specialists and anesthesiologists.Our review focuses on recent advances in order to present the complex underlying pathophysiology and guidelines concerning diagnosis,monitoring and treatment of this life-threatening condition.
文摘Background Fall injuries are common among the elderly. The aim of this study was to investigate whether blood-pressure patterns, as measured by 24-h ambulatory blood pressure monitoring (ABPM), or intensification of antihypertensive therapy following the 24-h ABPM, may be associated with fall injuries in hypertensive elderly patients. Methods In a retrospective study, community-based elderly patients (age ≥ 70 years) who were referred to 24-h ABPM were evaluated for fall injuries within one-year post-ABPM. We compared the clinical characteristics, 24-h ABPM patterns and the intensification of hypertensive therapy following 24-h ABPM, between patients with and without a fall injury. Results Overall 1032 hypertensive elderly patients were evaluated. Fifty-five (5.3%) had a fall injury episode in the year following ABPM. Patients with a fall injury were significantly older, and with higher rates of previous falls. Lower 24-h diastolic blood-pressure (67.3 ± 7.6 vs. 70.7 ± 8.8 mmHg; P 〈 0.005) and increased pulse-pressure (74.7 ± 14.3 vs. 68.3 ± 13.7 mmHg; P 〈 0.005), were found in the patients with a fall injury, compared to those without a fall injury. After adjustment for age, gender, diabetes mellitus and previous falls, lower diastolic blood-pressure and increased pulse-pressure were independent predictors of fall injury. Intensification of antihypertensive treatment following the 24-h ABPM was not associated with an increased rate of fall injury. Conclusions Low diastolic blood-pressure and increased pulse-pressure in 24-h ABPM were associated with an increased risk of fall injury in elderly hypertensive patients. Intensification of antihypertensive treatment following 24-h ABPM was not associated with an increased risk of fall injury.
文摘In accordance with the trans-lamina cribrosa pressure difference theory, decreasing the trans-lamina cribrosa pressure difference can re- lieve glaucomatous optic neuropathy. Increased intracranial pressure can also reduce optic nerve damage in glaucoma patients, and a safe, effective and noninvasive way to achieve this is by increasing the intra-abdominal pressure. The purpose of this study was to observe the changes in orbital subarachnoid space width and intraocular pressure at elevated intra-abdominal pressure. An inflatable abdominal belt was tied to each of 15 healthy volunteers, aged 22-30 years (12 females and 3 males), at the navel level, without applying pressure to the abdomen, before they laid in the magnetic resonance imaging machine. The baseline orbital subarachnoid space width around the optic nerve was measured by magnetic resonance imaging at 1, 3, 9, and 15 mm behind the globe. The abdominal belt was inflated to increase the pressure to 40 mmHg (1 mmHg = 0.133 kPa), then the orbital subarachnoid space width was measured every 10 minutes for 2 hours. After removal of the pressure, the measurement was repeated 10 and 20 minutes later. In a separate trial, the intraocular pressure was measured for all the subjects at the same time points, before, during and after elevated intra-abdominal pressure. Results showed that the baseline mean orbital subarachnoid space width was 0.88 + 0.1 mm (range: 0.77-1.05 mm), 0.77 + 0.11 mm (range: 0.60-0.94 mm), 0.70 + 0.08 mm (range: 0.62-0.80 ram), and 0.68 _+ 0.08 mm (range: 0.57-0.77 mm) at 1, 3, 9, and 15 mm behind the globe, respectively. During the elevated intra-abdominal pressure, the orbital subarachnoid space width increased from the baseline and dilation of the optic nerve sheath was significant at 1, 3 and 9 mm behind the globe. After decompression of the abdominal pressure, the orbital subarachnoid space width normalized and returned to the baseline value. There was no significant difference in the intraocular pressure before, during and after the intra-abdominal pressure elevation. These results verified that the increased intra-abdominal pressure widens the orbital subarachnoid space in this acute trial, but does not alter the intraocular pressure, indicating that intraocular pressure is not affected by rapid increased in- tra-abdominal pressure. This study was registered in the Chinese Clinical Trial Registry (registration number: ChiCTR-ONRC-14004947).
文摘AIM: To determine the influence of intra-abdominal pressure(IAP) on respiratory function after surgical repair of ventral hernia and to compare two different methods of IAP measurement during the perioperative period. METHODS: Thirty adult patients after elective repair of ventral hernia were enrolled into this prospective study.IAP monitoring was performed via both a balloontipped nasogastric probe [intragastric pressure(IGP), Ci MON, Pulsion Medical Systems, Munich, Germany] and a urinary catheter [intrabladder pressure(IBP), Uno Meter Abdo-Pressure Kit, Uno Medical, Denmark] on five consecutive stages:(1) after tracheal intubation(AI);(2) after ventral hernia repair;(3) at the end of surgery;(4) during spontaneous breathing trial through the endotracheal tube; and(5) at 1 h after tracheal extubation. The patients were in the complete supine position during all study stages.RESULTS: The IAP(measured via both techniques) increased on average by 12% during surgery compared to AI(P < 0.02) and by 43% during spontaneous breathing through the endotracheal tube(P < 0.01). In parallel, the gradient between РаСО2 and Et CO2 [Р(а-et)CO2] rose significantly, reaching a maximum during the spontaneous breathing trial. The PаO2/Fi O2 decreased by 30% one hour after tracheal extubation(P = 0.02). The dynamic compliance of respiratory system reduced intraoperatively by 15%-20%(P < 0.025). At all stages, we observed a significant correlation between IGP and IBP(r = 0.65-0.81, P < 0.01) with a mean bias varying from-0.19 mm Hg(2SD 7.25 mm Hg) to-1.06 mm Hg(2SD 8.04 mm Hg) depending on the study stage. Taking all paired measurements together(n = 133), the median IGP was 8.0(5.5-11.0) mm Hg and the median IBP was 8.8(5.8-13.1) mm Hg. The overall r2 value( n = 30) was 0.76(P < 0.0001). Bland and Altman analysis showed an overall bias for the mean values per patient of 0.6 mm Hg(2SD 4.2 mm Hg) with percentage error of 45.6%. Looking at changes in IAP between the different study stages, we found an excellent concordance coefficient of 94.9% comparing IBP and IGP( n = 117).CONCLUSION: During ventral hernia repair, the IAP rise is accompanied by changes in Р(а-et)CO2 and PаO2/Fi O2-ratio. Estimation of IAP via IGP or IBP demonstrated excellent concordance.
文摘A proof-of-concept indirect tire-pressure monitoring system is developed using artificial neural networks to identify the tire pressure of a vehicle tire.A quarter-car model was developed with MATLAB and Simulink to generate simulated accelerometer output data.Simulation data are used to train and evaluate a recurrent neural network with long short-term memory blocks(RNN-LSTM)and a convolutional neural network(CNN)developed in Python with Tensorflow.Bayesian Optimization via SigOpt was used to optimize training and model parameters.The predictive accuracy and training speed of the two models with various parameters are compared.Finally,future work and improvements are discussed.
文摘Despite an increasing popularity of home blood pressure monitoring (HBPM) over the last few decades, little is known about HBPM use among hypertensive patients in the rural areas. A cross-sectional survey including 318 hypertensive patients was conducted in a rural community in Beijing, China, in 2012. Participants were mainly recruited from a community health clinic and completed the questionnaires assessing HBPM usage. Binary logistic regression models were used for the analysis of medication adherence with age, gender, level of education marital status, perceived health status, duration of hypertension, HBPM use, and frequency of performing BP measurement. Among the total population, 78 (24.5%) reported currently use of HBPM. Only 5.1% of the HBPM users cited doctor’s advice as the reason for using HBPM. Analysis of the risk factors of poor medication adherence by multivariable modeling indicated significant associations between the duration of hypertension (adjusted OR, 3.31;95% CI, 1.91-5.72;P 01), frequency of performing BP measurements (adjusted OR, 2.33;95% CI, 1.42-3.83;
文摘This article is a review of 25 publications on ambulatory blood pressure monitoring(ABPM) and the importance of its results in everyday clinical practice. These studies, published in 2008-2011, were selected from the Scopus database, but are also available in Pubmed. They were prepared by researchers from around the world, concerned with the problems of proper control of blood pressure(BP), and of abnormalities in the circadian pattern of BP in patients with arterial hypertension, diabetes mellitus or renal failure. In the first part of this article, I analyse publications focused on some nuances in the methodology of ABPM and recommend ways to avoid some traps, related not only to the individual patient but also to the device used and the technical staff. The next section is devoted to the advantages of ABPM as a diagnostic tool which enables clinicians to learn about patients' BP during sleep, and emphasizes the practical implications of this information for so-called chronotherapy. This section also presents some new studies on the prognostic value of ABPM in patients with cardiovascular(CV) risk. Some recent articles on the results of various methods of pharmacological treatment of arterial hypertension in different agegroups are then described. The observations presented in this article may be helpful not only for researchers interested in the chronobiology of the CV system, but also for general practitioners using ABPM.
文摘Heart failure (HF) is an emerging epidemic associate with significant morbidity, mortality, and health care expenditure. Although there were major advances in pharmacologic and device based therapies for the management of HF, mortality of this condition remains high. Accurate monitoring of HF patients for exacerbations is very important to reduce recurrent hospitalizations and its associated complications. With the failure of clinical signs, tele-monitoring, and laboratory bio-markers to function as early markers of HF exacerbations, more sophisticated techniques were sought to accurately predict the circulatory status in HF patients in order to execute timely pharmacological intervention to reduce frequent hospitalizations. CardioMEMS<sup>TM</sup> (St. Jude Medical, Inc., Saint Paul, Minnesota) is an implantable, wireless pulmonary arterial pressure (PAP) monitoring system which transmits the patient’s continuous PAPs to the treating health care provider in the ambulatory setting. PAP-guided medical therapy modification has been shown to significantly reduce HF-related hospitalization and overall mortality. In advanced stages of HF, wireless access to hemodynamic information correlated with earlier left ventricular assist device implantation and shorter time to heart transplantation.
基金Supported by the Shanghai Science Committee Project(No.Y232821D01)
文摘This paper presents an RF energy harvesting system for wireless intraocular pressure monitoring applications.The system consists of an implantable antenna and a rectifier.A new sizing strategy is adopted to optimize the conversion efficiency of the rectifier,and the design principle of an implantable antenna is introduced from material selection and structure design.Results from testing demonstrate that the antenna gain is about-20 dBi and the rectifier's maximum total conversion efficiency which contains match efficiency and rectifying efficiency is 47.18%under the implementation of0.18μm standard CMOS process.The maximum power obtained from the proposed system is 8μW when the power density of electromagnetic wave is lower than the national standard 40μW/cm^2 at915 MHz,which is enough to power the intraocular pressure monitoring system.
文摘This paper presents the tire pressure monitoring system (TPMS) by using the system on chip (SoC) mixed signals with the help of Bluetooth transmission and in advantage of low power consumption design. This is to monitor the variations in temperature and pressure of the vehicle’s tire, and the TPMS system is involved. It improves the driver’s safety by automatically detecting the tire pressure and temperature and then warning signal is sent to driver to take a measure, which prevents from accident. The proposed system of tire pressure monitoring system using SoC increases the speed of indication time to the driver by using mixed signals. The inflation of the tire can be avoided by preventing from high temperature and high pressure. Limitation of temperature and pressure in the previous system is also elongated i.e. temperature from 40℃ to 125℃ and pressure from 0 to 750 Kpa. Sensors, wireless communication (Bluetooth dongle) and SoC unit are used to design the low power TPMS. Quantitative results are taken and the analogy between temperature and pressure is also verified. The tested results proved by need of the practical system. Signal conditioning voltage and SoC unit is the trace for low power design TPMS. Finally, the performance of the system is tested and executed by using proteus software given as a real time application.
文摘Glaucoma is a neurodegenerative condition that is the leading cause of irreversible blindness worldwide. Elevated intraocular pressure (IOP) is the main risk factor for the development and progression of the disease. Methods to lower IOP remain the first line treatments for the condition. Current methods of IOP measurement do not permit temporary noninvasive monitoring 24-hour IOP on a periodic basis. Ongoing research will in time provide a means of developing a device that will enable continuous or temporary monitoring of IOP. At present a device suitable for clinical use is not yet available.This review contains a description of different devices currently in development for measuring IOP: soft contact lens, LC resonant circuits and on-chip sensing devices. All of them use application-specific integrated circuits (ASICS) to process the measured signals and send them to recording devices. Soft contact lens devices are based on an embedded strain gauge, LC circuits vary their resonance frequency depending on the intraocular pressure (IOP) and, finally, on-chip sensing devices include an integrated microelectromechanical sensor (MEMS). MEMS are capacitors whose capacity varies with IOP. These devices allow for an accurate IOP measurement (up to +/– 0.2 mm Hg) with high sampling rates (up to 1 sample/min) and storing 1 week of raw data. All of them operate in an autonomous way and even some of them are energetically independent.
文摘Management of hypertension (HTN) largely relies on proper and accurate measurement of blood pressure (BP). Even following the criteria for HTN diagnosis defined in the Fourth report on high BP in children and adolescents, inaccurate diagnosis and misdiagnosis can occur with white coat effect and masked HTN. The use of Ambulatory Blood Pressure Monitoring (ABPM) has been increasing in pediatrics in the last 20 years. The main use of ABPM is to differentiate between sustained HTN and white coat HTN in patients who have elevated casual BP measurements and to detect masked HTN in high risk patients. ABPM is most useful in patients with casual BP within 20% of the 95th percentile for age, gender, and height. This report will highlight the use of ABPM in the evaluation of elevated BP and management of HTN in pediatrics. The discussion includes a review of various non-invasive BP measuring techniques, a description of ABPM and ABPM-unique data and diagnoses, updated ABPM clinical data more specific to pediatrics, its use in HTN clinical trials, and future outlook and direction of ABPM in pediatrics.
文摘Objectives: To study the ambulatory measured blood pressure (ABPM) profile in normotensive patients with mild cognitive impairment (MCI). Patients and Methods: The study was designed as a case control study including 50male patients with mild cognitive impairment in the age group of 30 - 50 years old. The control group included 30 volunteers with no cognitive impairment and in the same age group (30 - 50 years old) and same gender. Mini-mental estate examination, office and ABP monitoring (ABPM) and brain MRI scans were done for cases and controls. Results: Thirty patients (60%) with MCI revealed a non-dipper blood pressure pattern. Sleeping systolic blood pressure and sleeping systolic load were significantly higher in patients with MCI than in normal volunteers (p = 0.01). MRI brain showed more white matter lesions (WMLs) in patients with MCI than in normal volunteers;however, this didn’t reach significance level (p = 0.056). Conclusion: MCI in normotensive young adult patients could reflect an abnormal circadian blood pressure rhythm. Ambulatory blood pressure monitoring could be an essential investigation in young adult MCI patients.
文摘Upon the analysis of the interior and exterior pressures observed on the double-tubbing shaftwalls of the West Ventilation Shaft in Xieqiao Coal Mine of Huainan, deep-going investigations are made into foreign loads on the shaftwalls of thes kind at each working stage and into the distributiona patterns of interior pressures. As a result, a calculation model is established for forecasting exterior loads on the shaftwalls by using the grey theory.