期刊文献+
共找到479篇文章
< 1 2 24 >
每页显示 20 50 100
Releasing of Cupric Ion of Three types of Copper-bearing Intrauterine Contraceptive Device in Simulated UterineFluid 被引量:3
1
作者 Jie GAO Ying LI +1 位作者 Jian-ping LIU Xuan GU 《Journal of Reproduction and Contraception》 CAS 2007年第1期33-39,共7页
Objective To compare the cupric ion releasing in vitro o.f the three IUDs. Methods The stability o.f cupric ion releasing o.f IUDs including TCu 380.4 IUD (TCu 380A), Multiload Cu375 IUD (MCu 375) and Yuangong 365... Objective To compare the cupric ion releasing in vitro o.f the three IUDs. Methods The stability o.f cupric ion releasing o.f IUDs including TCu 380.4 IUD (TCu 380A), Multiload Cu375 IUD (MCu 375) and Yuangong 365 copper-bearing indomethacin-releasing IUD (Yuangong 365) by the determination of cupric ion releasing in simulated uterine fluid. The simulated uterine fluid was used for releasing media. Copper ion was determined by flame atomic absorption spectrometer. Results The cupric ion releasing of three IUDs were instable at the beginning and tend to be stable gradually. In the stable phase, the average level of cupric ion releasing of TCu380A, MCu375 and Yuangong 365 were 4.25±2.71-7.62±6.42 μg, 4.92±1.23 -8.62±3.08 μg and 2.19±0.40-4.68±1.66 μg, respectively. TCu380A had higher instable releasing level than those of Yuangong 365 (P〈0. 05). Conclusion TCu 380.4 and MCu 375 showed a "burst release" during the first few days and the.former was of great significance(P〈0.05). The initial cupric ion releasing of Yuangong 365 appeared to be the lowest, followed by MCu375 and TCu380A in a releasing order 展开更多
关键词 copper-bearing intrauterine contraceptive device CU-iud the releasing ofcupric ion simulated uterine fluid flame atomic absorption spectrometer
下载PDF
Intrauterine contraceptive device appendicitis: A case report
2
作者 Chung-Bao Hsieh Chung-Jueng Chen Jyh-Cherng Yu 《World Journal of Gastroenterology》 SCIE CAS CSCD 2005年第34期5414-5415,共2页
Uterine perforation is one of the serious complications associated with use of the intrauterine contraceptive device (IUD). Uterine perforaUon by IUD can involve several neighboring organs. A case of acute appendici... Uterine perforation is one of the serious complications associated with use of the intrauterine contraceptive device (IUD). Uterine perforaUon by IUD can involve several neighboring organs. A case of acute appendicitis was caused by a Multiload Cu 375 TUD inserted previously. This is a rare complication and only fourteen previous cases were recorded in the literature. 展开更多
关键词 Appendidcitis intrauterine contraceptive device Uterine perforation
下载PDF
Can We Predict Menorrhagia with Intrauterine Contraceptive Device (IUCD) Insertion?
3
作者 Ghada M. Mansour Sherif H. Hussein +3 位作者 Haitham F. Mohammed Sherif F. El Mekkawy Sherif A. Akl Asmaa A. Abd El Dayem 《Open Journal of Obstetrics and Gynecology》 2017年第7期753-766,共14页
Objective: Studying sub endometrial vascularity and blood flow in cases using intrauterine contraceptive devices for contraception with and without menorrhagia compared to cases not using intrauterine contraceptive de... Objective: Studying sub endometrial vascularity and blood flow in cases using intrauterine contraceptive devices for contraception with and without menorrhagia compared to cases not using intrauterine contraceptive devices. Methods: Three hundred and fifteen women attending gynecology and family planning outpatient clinics in the maternity hospital, Ain Shams University were included in the study. They were classified into three groups, 105 women using IUCD with menorrhagia (group I), 105 women using IUCD without menorrhagia (group II), and 105 normal controls not using IUCD (group III). After excluding local causes for bleeding, blood disease or any medical disorders, transvaginal ultrasound including three dimensional power Doppler (3DPD) ultrasound was done for all women. Right and left uterine artery pulsatility index (PI) and resistance index (RI) were calculated, subednometrial blood flow RI and PI were obtained then 3DPD Vascular indices (VI, FI and VFI) of subendometrial blood flow were obtained for all cases. Statistical analysis was done to compare between the three groups. Results: A significant statistical difference was found as regards subendometrial vascularity indices, while there was no difference as regards bilateral uterine arteries Doppler indices in the three groups. Conclusion: Subendometrial vascularity in cases of menorrhagia with IUCD was markedly higher than in cases without menorrhagia and cases with no IUCD. 3DPD may be used for selection of cases prior to insertion of IUCD. 展开更多
关键词 intrauterine contraceptive devices IUCD 3D Power DOPPLER Ultrasound MENORRHAGIA
下载PDF
Role of IL-6 in the contraceptive mechanism of intrauterine device
4
作者 Zhu Dan Wang Liyan +1 位作者 Fu Li Jia Ruiying 《白求恩医科大学学报》 CSCD 2000年第6期597-599,共3页
目的 :探讨血清中白细胞介素 - 6(IL- 6)水平与宫内节育器 (IUD)存在的关系。方法 :采用酶联免疫吸附试验测定 64例置器妇女 (试验组 ,试验组又分为置器出血组和无出血组 ) ,以及60例健康妇女 (对照组 )血清中 IL- 6水平 ,同时测定两组... 目的 :探讨血清中白细胞介素 - 6(IL- 6)水平与宫内节育器 (IUD)存在的关系。方法 :采用酶联免疫吸附试验测定 64例置器妇女 (试验组 ,试验组又分为置器出血组和无出血组 ) ,以及60例健康妇女 (对照组 )血清中 IL- 6水平 ,同时测定两组血清中 C-反应蛋白 (CRP)水平。结果 :试验组 64例中有 31例血中 IL- 6水平升高 ,与对照组相比差异显著 (P<0 .0 1 )。但其中置器出血组与不出血组中 IL- 6水平无统计学差异 (P>0 .0 5)。试验组及对照组血清中 CRP检验结果均为阴性。结论 :宫内节育器引起子宫内膜无菌性炎症反应 ,导致部分妇女血清中 IL- 6水平升高。IL- 展开更多
关键词 intrauterine contraceptive devices INTERLEUKIN-6 C-reactive protein
下载PDF
Postpartum intrauterine device contraception: A review
5
作者 Shadi Rezai Pameela Bisram +2 位作者 Hasan Nezam Ray Mercado Cassandra E Henderson 《World Journal of Obstetrics and Gynecology》 2016年第1期134-139,共6页
AIM: To review the safety (infection, perforation) and efficacy (expulsion, continuation rates, pregnancy) of intrauterine device (IUD) insertion in the postpartum period. METHODS: MEDLINE, PubMed and Google S... AIM: To review the safety (infection, perforation) and efficacy (expulsion, continuation rates, pregnancy) of intrauterine device (IUD) insertion in the postpartum period. METHODS: MEDLINE, PubMed and Google Scholar were searched for randomized controlled trials and prospective cohort studies of IUD insertions at different times during the postpartum period. Time of insertion during the postpartum period was documented speci-fically, immediate post placenta period (within 10 min), early post placenta period (10 min to 72 h), and de-layed/interval period (greater than 6 wk). Other study variables included mode of delivery, vaginal vs cesarean, manual vs use of ring forceps to insert the IUD. RESULTS: IUD insertion in the immediate postpartum (within 10 min of placental delivery), early postpartum (10 min up to 72 h) and Interval/Delayed (6 wk onward) were found to be safe and effcacious. Expulsion rates were found to be highest in the immediate postpartum groups ranging from 14% to 27%. Immediate post placental insertion found to have expulsion rates that ranged from 3.6% to 16.2%. Expulsion rate was significantly higher after insertion following vaginal vs cesarean delivery. The rates of infection, perforation and unplanned pregnancy following postpartum IUD insertion are low. Method of insertion such as with ring forceps, by hand, or another placement method unique to the type of IUD did not show any signifcant difference in expulsion rates. Uterine perforations are highest in the delayed/interval IUD insertion groups.Breastfeeding duration and infant development are not affected by delayed/interval insertion of the non-hormonal (copper) IUD or the Levonorgestrel IUD. Timing of the Levonorgestrel IUD insertion may affect breastfeeding. CONCLUSION: IUD insertion is safe and efficacious during the immediate postpartum, early postpartum and delayed postpartum periods. Expulsion rates are highest after vaginal delivery and when inserted during the immediate postpartum period. IUD associated infection rates were not increased by insertion during the postpartum period over interval insertion rates. There is no evidence that breastfeeding is negatively affected by postpartum insertion of copper or hormone-secreting IUD. Although perforation rates were higher when inserted after lactation was initiated. Randomized controlled trials are needed to further elucidate the consequence of lactation on postpartum insertion. Despite the concerns regarding expulsion, perforation and breastfeeding, current evidence indicates that a favorable risk beneft ratio in support of postpartum IUD insertion. This may be particularly relevant for women for whom barriers exist in achieving desired pregnancy spacing. 展开更多
关键词 Access to intrauterine devices Contra-ception EXPULSION intrauterine device Long acting reversible contraception Postpartum contraception Postpartum intrauterine device Postpartum intrauterine device placement Post-placental insertion
下载PDF
Barriers to Intrauterine Device Use at an University-Based Women’s Clinic
6
作者 Denise Ragland Nalin Paykachat Nafisa Dajani 《Open Journal of Obstetrics and Gynecology》 2014年第16期1058-1064,共7页
Objective: The purpose of this study was to determine the barriers to intrauterine device (IUD) use at a University-Based Women’s Clinic. Methods: This study is a cross-sectional survey of a convenience sample of sub... Objective: The purpose of this study was to determine the barriers to intrauterine device (IUD) use at a University-Based Women’s Clinic. Methods: This study is a cross-sectional survey of a convenience sample of subjects receiving obstetrical care at a University-Based Women’s Clinic. Eligible women who consented to participate self-administered a 16-question survey during a routine prenatal visit. Descriptive statistics were used to report participants’ demographics and history of contraception use. Additionally, subjects were asked if they would consider IUD use in the future. Results: A total of 160 women participated in this study. The average age of this sample was 24.9 (SD = 6.3). The majority were in low income and low education categories. Only 5% of women reported previous IUD use. 27% of women surveyed desired more information regarding IUD contraception. 19% of participants would consider using an IUD in the future and 25% would consider?IUD in the future if they knew more about them. Insurance and financial constraints were cited as barriers to IUD use. 4% of the sample reported that they had used an IUD previously and were unhappy with it due to pain and discomfort. 18% would not consider an IUD because they had heard about side effects. 68%?of the surveyed sample reported unintended pregnancies. Conclusion: The two most common barriers to IUD use in this patient population was lack of knowledge?and concern about side effects. Increasing patients’ knowledge of IUDs has the potential to increase IUD utilization in this clinic population which reported a 68% rate of unintended pregnancy. 展开更多
关键词 intrauterine device intrauterine contraceptION iud Utilization Barriers Unintended PREGNANCIES Component Formatting Style STYLING
下载PDF
A comparative, randomized study of levonorgestrel Intrauterine System (LNG-IUS) vs Copper T 380 A intrauterine device applied during cesarean section
7
作者 José A. López-Farfan Alicia Hernandez-Gonzalez +1 位作者 Irvin J. Vélez-Machorro Leopoldo A. Vázquez-Estrada 《Open Journal of Obstetrics and Gynecology》 2012年第2期151-155,共5页
Objective: To assess levonorgestrel-releasing intrauterine system LNG-IUS (Mirena?) application at caesarean section (CS). Design: Randomized, comparative study. Setting: Department of obstetrics and gynecology in a p... Objective: To assess levonorgestrel-releasing intrauterine system LNG-IUS (Mirena?) application at caesarean section (CS). Design: Randomized, comparative study. Setting: Department of obstetrics and gynecology in a primary reference hospital at Puebla City, Mexico. Sample: 396 women requiring CS signed informed consent and were randomly allocated to the post-placental application of LNG-IUS (198) or Copper T 380 A (198). Methods: Follow up visits at 6 weeks, and 6 and 12 months were performed. Main Outcomes Measures: IUDs expulsion, maternal and babies’ health conditions, breastfeeding and menstrual patterns, adverse effects and pregnancies. Differences between groups were analyzed by Fisher and X2 tests, Odds ratios, relative risk and 95% confidence limits, as appropriate. Results: After one year of follow up, no pregnancies were reported. The IUD expulsion rate was 4.5% in each group. LNG-IUS users had a higher incidence of amenorrhea (OR 2.5 95% CI 2.2 - 3) and menstrual patterns significantly brief and lighter than Copper T 380 A (p < 0.001) with lower incidence of dysmenorrhea (OR 0.1 95% CI 0.04 - 0.2). No detrimental effects of LNG-IUS on breastfeeding was observed and interestingly babies weights of LNG-IUS users was slightly above the average for age compared with Copper T 380 A users. This was probably related with a major proportion of women with normal ferritin serum levels (94% vs 68%) leading to better mother’s general condition. Conclusions: LNG-IUS inserted during CS provides high efficacy contraception with additional benefits, mainly reducing menstrual bleeding and doing so, faster recovery of ferrous homeostasis after CS. 展开更多
关键词 Levonorgestrel-Releasing intrauterine System Medicated iud Copper T iud CESAREAN Section Postpartum contraceptION Ferritin Levels
下载PDF
Com parison betw een Two Techniques Used in Im m ediatePostplacentalInsertion of TCu 380AIntrauterine Device:36-Month follow-up
8
作者 徐晋勋 杨秀兰 +5 位作者 顾兴林 徐素英 周晓波 陈月贞 肖志琴 庄留琪 《Journal of Reproduction and Contraception》 CAS 1999年第3期156-162,共7页
Three hundred and eighty four women in Shanghai who delivered vaginally and chose IUD for contraception received the copper T 380A IUD inserted vaginally within 10 min after delivery of the placenta(i.e.,immediate pos... Three hundred and eighty four women in Shanghai who delivered vaginally and chose IUD for contraception received the copper T 380A IUD inserted vaginally within 10 min after delivery of the placenta(i.e.,immediate postplacental insertion, IPPI). Among them, 98.70% were primipara. The women were randomly divided into two groups: IUD inserted by hand and IUD insreted by ring forceps. Using Life Table Method and χ 2 test, expulsion and other discontinuation rates were compared at 6, 12, 24, and 36 months post insertion between these two different groups. No uterine perforation, infection or prolonged period of lochia occurred in the 384 cases. Expulsions were the main reason for discontinuation. From 6 months to 36 months, the gross cumulative rates of all discontinuation events (expulsion, pregnancy, removal for bleeding/pain, etc.) were not statistically significantly different (P>0.05). The results suggest that these two different insertion techniques do not significantly affect discontinuation rate in vaginal IPPI using the TCu 380 A, which appears to be suitable for postpartum insertion in Chinese women. Other relevant issues, such as breast feeding and IUD position in uterine cavity, are also analyzed and discussed in this paper. 展开更多
关键词 intrauterine device Copper T 380A iud (TCu 380A iud) Immediate postplacental insertion (IPPI) Vaginal delivery Follow up studies
下载PDF
Intravesical Migration of Intrauterine Device and Calculi Formation 12 Years Post Missing: A Case Report
9
作者 Ahmad Rezaee Azandaryani Pezhman Ghaderzadeh Leili Ebrahimi Farsangi 《Case Reports in Clinical Medicine》 2017年第1期24-30,共7页
Intraunterine device (IUD) is a safe, effective and feasible method used for reversible contraception worldwide. Transvesical migration of an Intrauterine device (IUD) is a rare complication. We describe a case in who... Intraunterine device (IUD) is a safe, effective and feasible method used for reversible contraception worldwide. Transvesical migration of an Intrauterine device (IUD) is a rare complication. We describe a case in whom initially a plain abdominopelvic radiography demonstrated calcified string of an IUD in a 42-year-old woman with recurrent lower urinary symptoms (LUTS) and urinary tract infection since 2 years earlier. The IUD had been inserted 12 years earlier and 3 years after placement of the IUD, the patient experienced an uneventful pregnancy and a successful delivery. Sonographic images and later on the cystoscopic procedure confirmed the diagnosis of transvesical migration of the IUD. The IUD was removed using cystoscopic procedure, leaving no complication. 展开更多
关键词 BLADDER Stone intrauterine contraceptive device INTRAVESICAL MIGRATION
下载PDF
Opinions and Perceptions of Gynecologists and Midwives on the Use of the Intrauterine Device in Senegal
10
作者 Hadja Maimouna Barro Daff Khalifa Babacar Mansour Fall +7 位作者 Youssoupha Touré Aïssatou Mbodji Moussa Diallo Abdoul Aziz Diouf Magatte Mbaye Khalifa Babacar Gueye Babacar Biaye Alassane Diouf 《Open Journal of Obstetrics and Gynecology》 2021年第11期1484-1493,共10页
<strong>Objective: </strong><span><span><span style="font-family:""><span style="font-family:Verdana;">The purpose of this study was to analyze the opinions... <strong>Objective: </strong><span><span><span style="font-family:""><span style="font-family:Verdana;">The purpose of this study was to analyze the opinions of gynecologists, midwives, and interns/Specialist students practicing in Senegal about the use of IUD, and to assess factors that stand as obstacles to IUD prescribing. </span><b><span style="font-family:Verdana;">Patients and methods: </span></b><span style="font-family:Verdana;">An online questionnaire was developed to assess providers’ IUD practices and attitudes. The questionnaire was based on the one used in a Swiss study on the same topic. The platform used was Google forms. The questionnaire was shared in associative platforms involving gynecologists, midwives and interns/Specialist students. </span><b><span style="font-family:Verdana;">Results and comments: </span></b><span style="font-family:Verdana;">We received 292 feedbacks. Gynecologists represented 13.7% of the sample, interns and specialist students 11.3% and midwives 76%. Parity is a determining factor in IUD selection. The care-providers were concerned about the followings, which might have prevented the use of IUD, even </span><span style="font-family:Verdana;">though it </span></span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;">was</span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;"> indicated: infections (75.7%), pelvic pain (61.3%), expulsion (48.3%), increased risk of perforation (46.9%), women’s appreciation </span></span></span><span><span><span style="font-family:""><span style="font-family:Verdana;">(45.2%), ectopic pregnancy (33.9%) and sexual behavior (28.4%). </span><b><span style="font-family:Verdana;">Conclusion: </span></b><span style="font-family:Verdana;">Our study reveals that providers’ apprehensions and concerns severely limit the availability of IUDs. These concerns are often unfounded, based on personal experiences and not on official recommendations. Parity is a major obstacle.</span></span></span></span> 展开更多
关键词 intrauterine device iud PARITY Gynecologists MIDWIVES Interns
下载PDF
非意愿妊娠女性人工流产后放置吉妮致美IUD效果
11
作者 魏岚 韦玲 《中国计划生育学杂志》 2024年第1期142-145,共4页
目的:探讨非意愿妊娠女性人工流产后放置吉妮致美宫内节育器(IUD)效果.方法:以2021年7月-2022年7月在本院自愿要求人工流产术的未育女性213例,对实行流产后关爱干预,其中选择IUD避孕103例为观察组,未选择IUD避孕方法110例为对照组,问卷... 目的:探讨非意愿妊娠女性人工流产后放置吉妮致美宫内节育器(IUD)效果.方法:以2021年7月-2022年7月在本院自愿要求人工流产术的未育女性213例,对实行流产后关爱干预,其中选择IUD避孕103例为观察组,未选择IUD避孕方法110例为对照组,问卷调查比较两组干预前后对人工流产危害的知信行,比较流产后性生活恢复时间,随访1年非意愿妊娠及其妊娠原因、人工流产情况.结果:干预前后两组对人工流产危害性知识理论认知、态度信念、行为能力评分均提升(P<0.05),但两组间无差异;干预后观察组性生活恢复时间(3.7±0.1月)晚于对照组(3.2±0.9月),非意愿妊娠发生(8例,7.8%)低于对照组(24例,21.8%)(P<0.05),两组人工流产(0.9%、1.9%)发生无差异,观察组非意愿妊娠原因均为IUD脱落,对照组为避孕措施失败(11例,45.8%)和未避孕或避孕措施使用不正确(13例,54.2%).结论:吉妮致美IUD对降低人工流产后妇女非意愿妊娠有效,但需要重视IUD脱落率问题. 展开更多
关键词 人工流产后避孕 知信行 吉妮致美宫内节育器 非意愿妊娠 妊娠原因
下载PDF
瘢痕子宫人工流产术后即时放置元宫IUD与曼月乐IUD临床效果比较
12
作者 周晓红 苏爱芳 《中国计划生育学杂志》 2024年第6期1271-1274,共4页
目的:比较瘢痕子宫女性人工流产术后即时放置元宫IUD和曼月乐IUD临床效果。方法:选取2022年6月-2023年6月本院收治的瘢痕子宫行人工流产术女性104例,按照放置IUD种类的不同分组,分别放置元宫IUD(元宫组54例)、放置曼月乐IUD(曼月乐组50... 目的:比较瘢痕子宫女性人工流产术后即时放置元宫IUD和曼月乐IUD临床效果。方法:选取2022年6月-2023年6月本院收治的瘢痕子宫行人工流产术女性104例,按照放置IUD种类的不同分组,分别放置元宫IUD(元宫组54例)、放置曼月乐IUD(曼月乐组50例)。随访6个月,比较两组IUD使用效果、阴道出血情况和不良反应。结果:曼月乐组放置1个月、6个月累计续用率(100.0%、90.0%)与元宫组(98.2%、81.5%)无差异(P>0.05);术后阴道出血时间(5.4±2.3 d)及阴道出血量(53.3±10.5 ml)均少于元宫组(7.8±3.1 d、75.7±11.4 ml),不良反应发生率(8.0%)低于元宫组(24.1%)(均P<0.05)。结论:瘢痕子宫女性人工流产术后即时放置两种IUD避孕效果相当,但曼月乐IUD可有效改善术后阴道流血情况,降低不良反应发生率。 展开更多
关键词 瘢痕子宫 流产后避孕 宫内节育器 元宫 曼月乐 避孕效果 阴道出血 不良反应
下载PDF
A Comparative Study on the Contraception Efficacy and Safety of the Progesterone Releasing Contraceptive Vaginal Ring and the Copper T 380A IUD Inserted during the Lactation Period
13
作者 杜明昆 郑怀美 +1 位作者 郑苏华 陈帼君 《Journal of Reproduction and Contraception》 CAS 1996年第1期40-47,共8页
A comparative study was made on the contraception efficacy and safety of the vaginal ring releasing 10mg/day Of progesterone in 160 cases and an intrauterine device,the cOPPer T 380A in 100 cases during lactation.It w... A comparative study was made on the contraception efficacy and safety of the vaginal ring releasing 10mg/day Of progesterone in 160 cases and an intrauterine device,the cOPPer T 380A in 100 cases during lactation.It was found that the contraceptive method is acceptable from 42 to 60 days postpartum.No pregnancy occurred in the copper T 380A IUD users during lactation.Those methods are worth to be recommended because of their contraceptive efficacy and no adverse effects on breastfeeding children.Prenatal care and Family Planning Programe are administered together to raise lactation performance rate,and to decrease induced abortion rate,the health of mothers and children were protected. 展开更多
关键词 Vaginal ring intrauterine device POSTPARTUM Lactating Copper T 380A iud
下载PDF
未育女青年流产术后放置IUD与口服避孕药避孕效果及生命质量比较 被引量:1
14
作者 韩雪芹 董芬 《中国计划生育学杂志》 2023年第11期2550-2553,共4页
目的:比较分析未育女青年人工流产术后放置吉妮致美宫内节育器(IUD)和复方口服避孕药(COC)避孕效果及对生命质量的影响。方法:前瞻性选择2018年7月-2021年7月在本院早孕要求人工流产后避孕的未育女青108例,随机分组原则分为IUD组和COC组... 目的:比较分析未育女青年人工流产术后放置吉妮致美宫内节育器(IUD)和复方口服避孕药(COC)避孕效果及对生命质量的影响。方法:前瞻性选择2018年7月-2021年7月在本院早孕要求人工流产后避孕的未育女青108例,随机分组原则分为IUD组和COC组,流产术后分别采取IUD避孕或COC避孕。分析两组术后阴道流血时间、术后及时避孕率、术后1年再次妊娠以及重复流产率、生命质量(SF-36评分)。结果:术后阴道流血时间COC组(5.1±1.2d)少于IUD组(9.0±1.1d)(P<0.05),两组术后及时避孕率均为100%;术后1年,COC组再次妊娠(1.8%)及重复流产率(0)均低于IUD组(12.7%、10.9%),SF-36评分生理功能(75.47±2.9分)、生理职能(74.4±3.0分)、躯体疼痛(86.7±2.0分)、一般健康(86.7±2.0分)、精力(86.2±2.5分)、社会功能(87.5±3.0分)、情感职能(75.8±2.8分)、心理健康(88.9±3.0分)均高于IUD组(65.5±2.9分、70.7±2.8分、80.5±2.6分、80.6±2.5分、80.3±2.9分、77.9±2.5分、70.4±2.7分、77.8±2.6分)(均P<0.05)。结论:育龄妇女人工流产术后使用口服避孕药避孕,术后恢复更快,避孕有效率高,且提升避孕期间的生命质量。 展开更多
关键词 流产后避孕 吉妮致美宫内节育器 复方口服避孕药 有效率 生命质量
下载PDF
不同分娩史妇女早孕负压吸宫术后即时放置吉妮致美IUD的多中心临床观察 被引量:1
15
作者 吴尚纯 李来宝 +7 位作者 张建英 陈立霞 罗小婉 金平 杨艳娥 乐华 庞文艳 孟凡荣 《中国计划生育学杂志》 2023年第6期1291-1295,共5页
目的:观察不同分娩史妇女早孕负压吸宫术后即时放置吉妮致美IUD的效果。方法:将2017年1月-2019年10月在15家医院自愿要求于负压吸宫术后即时放置吉妮致美IUD的2994例作为观察对象,根据既往分娩方式分为阴道分娩组(1617例)和剖宫组(1377... 目的:观察不同分娩史妇女早孕负压吸宫术后即时放置吉妮致美IUD的效果。方法:将2017年1月-2019年10月在15家医院自愿要求于负压吸宫术后即时放置吉妮致美IUD的2994例作为观察对象,根据既往分娩方式分为阴道分娩组(1617例)和剖宫组(1377例),随访12个月。结果:共有2610例观察对象纳入12个月生命表分析,剖宫产组(1129例)放置12个月的帶器妊娠、脱落相关终止、因症取出和IUD相关终止的比尔指数分别为每百妇女年0.39、2.70、2.21、5.22,均高于阴道分娩组(1481例)的每百妇女年0.07、1.90、1.73、3.67,但两组间差异无统计学意义(P>0.05)。结论:不同分娩史对早孕负压吸宫术后即时放置吉妮致美IUD的效果无明显影响。 展开更多
关键词 吉妮致美宫内节育器 分娩方式 负压吸宫术流产后即时放置 避孕效果 生命表分析
下载PDF
Study on Vaginitis Among Intrauterine Contraceptive Device Users in Ibadan,South-western Nigeria 被引量:1
16
作者 Michael Abiola Okunlola Okonkwo N.Stella-Maris +1 位作者 Angelina A Tokzaka Oladosu.A Ojengbede 《Journal of Reproduction and Contraception》 CAS 2009年第4期247-255,共9页
Objective To investigate IUD-related vaginitis in IUD users at the University College Hospital Ibadan, South-western Nigeria.Methods A prospective cohort study in IUD users present with abnormal vaginal discharge at t... Objective To investigate IUD-related vaginitis in IUD users at the University College Hospital Ibadan, South-western Nigeria.Methods A prospective cohort study in IUD users present with abnormal vaginal discharge at the family planning clinic of the University College Hospital, Ibadan was conducted between lOth of October, 2008 and 31st of May 2009. High Vaginal Swabs were taken from the clients for microbiology, culture and drug sensitivity test. Diagnosis of bacterial vaginosis was made based on gram stained vaginal smear using the standard Nugents criteria. Other aetiological agents were identified either on wet preparation or culture using standard techniques. Treatment given was by the family planning nurse, as was the protocol at the family planning clinic.Results Twenty-four IUD users present at the Jamtty ptannmg ctmtc with vaginal discharge were studied. Their ages ranged 28-51 years(38.14 ± 5.9 years), Mean parity was 4.4 ± 1.4, All the women were married and all used CuT 380A. The mean duration of lUCD use was 2.5 years only. Majority (46%) had used it for more than 3 years and most (75%) of the visits were unscheduled. All the clients complained of abnormal vaginal discharge which was copious, watery and foul smelling, or clumpy. Nine users (37.5%) complained of pruritus vulvae, 3 users (12.5%) lower abdominal pain, 1 user (4,2%) dyspareunia and vaginosis was made in 16 (66. 7%) and 1 (4.2%) dysuria. The diagnosis of bacterial vaginal candidiasis in 8 (33.3%). Age less than 40 years, Christianity and IUD use more than 3 years were associated with a higher risk of bacterial vaginosis (OR=1.29, 1.67 and 6.6, respectively), while women above 40 years, Muslims and women with lower educational status had a higher risk of candida-related vaginitis (OR=1.67 and 4.2, respectively). Eight clients (33.3%) were treated for candidiasis with antifungals (3 empirically, and 5 after obtaining results of vaginal swab), 9 (37.5%) were given oral metronidazole, 3 patients were referred to the gynaecological emergency unit on account of abdominal pain and 4 did not return for follow up.Conclusion IUD associated vaginitis is a disturbing condition causing unscheduled visits among IUD users. Bacterial vaginosis and Candidia albicans are major aetiologies in south western Nigeria Ibadan. Persistent discharge is a documented reason for discontinuation of lUD use. Periodic empirical treatment for candidiasis and bacterial vaginosis with antifungals and oral metronidazole is advocated. This may reduce the discomfort caused by IUD-related vaginitis, the risk of PID and other risks exposed to the IUD users and ensure continued use of the IUD. 展开更多
关键词 intrauterine devices VAGINITIS contraceptION Ibadan NIGERIA
原文传递
Direct Interventional Discussion Effectively Improves Awareness and Knowledge about Modern Contraceptive Methods
17
作者 Abdelhaseib S. Saad Amr Sharafeldeen 《Advances in Reproductive Sciences》 2020年第1期1-13,共13页
Objectives: Determination of influence of direct interview of postpartum women about their awareness and knowledge regarding contraception and modern contraceptive methods. Patients & Methods: 1437 women joined th... Objectives: Determination of influence of direct interview of postpartum women about their awareness and knowledge regarding contraception and modern contraceptive methods. Patients & Methods: 1437 women joined the intervention and underwent evaluation of their knowledge about the concept and methods of contraception. Then, an interview was conducted with each woman to clarify advantages and appropriateness of various contraceptives and the proper time for initiation of contraception. All women were asked to discuss these data with their families and return to give their decision. Study outcomes included evaluation of women’s knowledge about contraception and its modalities, frequency of non-users who accepted to use contraception and is considered as success of the intervention and frequency of requesting each modality of contraception. Results: TV programs and discussion with local health provider, relatives or friends are the main sources of knowledge of primiparas. 182 primiparas had good knowledge and chose the appropriate method of contraception during the 1st session of discussion, and 81 primiparas required >2 sessions to choose the method appropriate for them, while 21 primiparas insisted not to use contraception for an acceptance rate of 92.6% among primipara. Among multiparas, 222 multiparas were non-users, but after discussion 133 couples accepted to use contraception. Thus, 396 non-users had accepted to use contraception for an intervention success rate of 78.3%. Collectively 692 women (52.1%) received IUD and 635 women (47.9%) received hormonal contraception;432 orally (32.6%) and 203 parenterally (15.3%). Conclusion: Ignorance, low financial status and cultural beliefs deleteriously affect knowledge about contraception options and its methods, so direct interview is mandatory. The applied intervention succeeded to replenish women’s knowledge about benefits of using contraception. Primiparas had knowledge about contraception but their knowledge about methods is deficient or hazy. Contraception using IUD is the most acceptable method especially for primiparas. 展开更多
关键词 KNOWLEDGE contraceptION MODERN Methods Primiparas intrauterine device
下载PDF
Impact of Social Determinants of Health on the Choice and Use of Long Acting Reversible Contraceptives
18
作者 Dani Zoorob Connor McNamee +2 位作者 Margaret Reilly Lindsey Loss James VanHook 《Advances in Reproductive Sciences》 2020年第3期166-174,共9页
Modern women have increased options for birth control with the development of Long Acting Reversible Contraceptives (LARCs). These methods are reliable, easy to use, and require less daily maintenance while providing ... Modern women have increased options for birth control with the development of Long Acting Reversible Contraceptives (LARCs). These methods are reliable, easy to use, and require less daily maintenance while providing contraception for an extended period of time. However, despite the surge of LARCs as contraceptive options, the prevalence of unintended pregnancies is still alarmingly high in the United States. As LARCs are the most effective reversible method of birth control at preventing pregnancy, and therefore the potential social, financial, and medical complications associated, we examined whether social determinants of health play a role in LARC usage. While parity and marriage do not seem to affect LARC utilization, increased research is needed to determine the effects of race. Age can affect the type of LARC implemented, as younger women prefer implants to intrauterine devices (IUDs). Insurance coverage was an apparent influencer of LARC usage, as low out-of-pocket costs translate to increased utilization. This is linked to socioeconomic status (SES), as lower SES is associated with decreased access to healthcare in general. Increased research is needed in order to draw conclusions about the effects of education, intimate partner violence, geographic location, and other SDH on LARC usage. 展开更多
关键词 Social Determinants of Health Long Acting Reversible contraceptives intrauterine devices DISPARITIES RACE Family Planning
下载PDF
25岁以下未育女性人工流产后即时落实宫内节育器和短效口服避孕药的临床对照观察
19
作者 尚禹 李来宝 +4 位作者 张英敏 林雪 张清 张爱华 吴尚纯 《中国计划生育学杂志》 2024年第9期2016-2019,2024,共5页
目的:观察25岁以下未育女性人工流产后即时放置宫内节育器(IUD)和使用短效复方口服避孕药(COC)的可行性和使用情况。方法:将≤25岁未育早孕自愿要求人工流产的女性作为观察对象,根据其意愿术后放置IUD或使用COC避孕。IUD组148例,COC组20... 目的:观察25岁以下未育女性人工流产后即时放置宫内节育器(IUD)和使用短效复方口服避孕药(COC)的可行性和使用情况。方法:将≤25岁未育早孕自愿要求人工流产的女性作为观察对象,根据其意愿术后放置IUD或使用COC避孕。IUD组148例,COC组204例,随访6个月观察两组的避孕情况。结果:两组均无妊娠发生。IUD组1例因完全脱落而终止使用,终止率为0.7%。COC组术后3月的累积停用率69.1%,6月达92.1%,停用的主要原因是嫌麻烦/不能坚持服药,占31.4%。术后1,3个月的不适主诉率IUD组高于COC组(P<0.010,P<0.001)。结论:≤25岁未育女性人工流产后即时放置IUD或使用COC避孕均可行高效。IUD组6个月续用率高;COC副作用轻,但需加强咨询,提高续用率。 展开更多
关键词 25岁以下未育女性 人工流产 宫内节育器 短效复方口服避孕药
下载PDF
无痛人流术后放置曼月乐与活性γ-宫内节育器的避孕效果比较
20
作者 张春红 孟庆霞 窦玉芝 《中国现代医学杂志》 CAS 2024年第12期90-94,共5页
目的 探讨无痛人流术后宫内放置曼月乐与活性γ-宫内节育器(γ-IUD)的临床效果比较。方法 选取2020年6月—2022年1月淄博市妇幼保健院收治的120例无痛人流手术后有避孕意愿的妇女作为研究对象。采用随机数字表法将其分为A、B组,每组60例... 目的 探讨无痛人流术后宫内放置曼月乐与活性γ-宫内节育器(γ-IUD)的临床效果比较。方法 选取2020年6月—2022年1月淄博市妇幼保健院收治的120例无痛人流手术后有避孕意愿的妇女作为研究对象。采用随机数字表法将其分为A、B组,每组60例。A组术后即刻宫内放置曼月乐避孕,B组术后即刻宫内放置活性γ-IUD避孕。对比两组妇女不同时间的宫内节育器续用情况、月经周期变化、性生活质量、并发症发生率差异。结果 术后6个月,A组与B组妇女的累积续用率分别为95.00%和98.33%,差异无统计学意义(χ^(2)=1.000,P=0.317)。术后12个月,A组与B组妇女的累积续用率为93.33%和96.67%,差异无统计学意义(χ^(2)=0.702,P=0.302)。A组与B组妇女术前、术后3个月的月经周期、行经时间、月经量及性欲、性唤起、性高潮、性心理、性行为、射精时间6个调查维度评分差值比较,差异均无统计学意义(P>0.05)。A组妇女术后总并发症发生率为23.33%,高于B组的8.33%(P <0.05)。结论 无痛人流术后宫内放置曼月乐与活性γ-IUD的宫内避孕效果、累积续用率、性生活情况差异不大,但是后者术后的并发症发生率更低,更推荐临床使用。 展开更多
关键词 无痛人流术 避孕 宫内节育 曼月乐 活性γ-iud
下载PDF
上一页 1 2 24 下一页 到第
使用帮助 返回顶部