A perspective on the key factors of safety for rechargeable magnesium batteries
1
作者 Shuangshuang Tan Jie Xu +5 位作者 Rongrui Deng Qiannan Zhao Chaohe Xu Guangsheng Huang Jingfeng Wang Fusheng Pan 《Journal of Energy Chemistry》 SCIE EI CAS CSCD 2024年第7期656-676,共21页
Rechargeable Mg batteries(RMBs)have become one of the best subsitutes for lithium-ion batteries due to the high volumetric capacity,abundant resources,and uniform plating behavior of Mg metal anode.However,the safety ... Rechargeable Mg batteries(RMBs)have become one of the best subsitutes for lithium-ion batteries due to the high volumetric capacity,abundant resources,and uniform plating behavior of Mg metal anode.However,the safety hazard induced by the formation of high-modulue Mg dendrites under a high current density(10 mA cm^(-1))was still revealed in recent years.It has forced researchers to re-examine the safety of RMBs.In this review,the intrinsic safety factors of key components in RMBs,such as uneven plating,pitting and flammability of Mg anode,heat release and crystalline water decomposition of cathode,strong corrosion,low oxidition stability and flammability of electrolytes,and soforth,are systematacially summarized.Their origins,formation mechanisms,and possible safety hazards are deeply discussed.To develop high-performance Mg anode,current strategies including designing artificial SEI,three-dimensional substrates,and Mg alloys are summarized.For practical electrolytes,the configurations of boron-centered anions and simple Mg salts and the functionalized solvent with high boiling point and low flammability are suggested to comprehensively design.In addition,the future study should more focus on the investigation on the thermal runaway and decomposition of cathode materials and separa-tors.This review aims to provide fundamental insights into the relationship between electrochemistry and safety,further promoting the sustainable development of RMBs. 展开更多
关键词 Rechargeable Mg batteries Battery safety Mg dendrites Electrolyte decomposition Intrinsic safety issues
下载PDF
Study on Critical,Modern Technology for Mining in Gassy Deep Mines 被引量:10
2
作者 YUAN Liang 《Journal of China University of Mining and Technology》 EI 2007年第2期226-231,共6页
To achieve safe and highly efficient mining in the gassy, deep mines of the Huainan collieries simultaneous coal and gas extraction, and the corresponding ventilation methods were developed. This includes a set of min... To achieve safe and highly efficient mining in the gassy, deep mines of the Huainan collieries simultaneous coal and gas extraction, and the corresponding ventilation methods were developed. This includes a set of mining procedures and principles which help insure safe and efficient production. Furthermore, green mining, meaning the comprehensive use of emitted gas, proper treatment of the environment and appropriate mine temperature control, is now standard. The concepts of modem mining and the principles of pressure relief are described. Coal-gas simultaneous ex- traction and multi-pressure relief techniques were developed which require a combination of surface and underground gas extraction. The application of Y-ventilation systems, of roadways retained along goafs, of stress control techniques for highly fragile mine roofs and of powerful, automatic and reliable mining equipment contributes to safe operation of modem deep mines. Operating parameters for these techniques are described and the results of their use discussed. 展开更多
关键词 gassy deep mining modem mining intrinsic safety coal and gas simultaneous extraction green mining
下载PDF
Optically powered gas monitoring system using single-mode fibre for underground coal mines 被引量:1
3
作者 Yingge Chen Leonardo Silvestri +1 位作者 Xinyue Lei François Ladouceur 《International Journal of Coal Science & Technology》 EI CAS CSCD 2022年第2期36-47,共12页
We present an optically powered,intrinsically safe gas monitoring system to measure four essential environmental gases(CH_(4),CO_(2),CO and O_(2)),together with ambient temperature and pressure,for underground mines.T... We present an optically powered,intrinsically safe gas monitoring system to measure four essential environmental gases(CH_(4),CO_(2),CO and O_(2)),together with ambient temperature and pressure,for underground mines.The system is based on three key technologies developed at UNSW:(1)power-over-fbre(PoF)at 1550 nm using a single industry-standard,low-cost single-mode fbre(SMF)for both power delivery and information transmission,(2)liquid–crystal-based optical transducers for optical telemetry,and(3)ultra-low power consumption design of all electronics.Together,this approach allows each gas monitoring station to operate with less than 150 mW of optical power,meeting the intrinsic safety requirements specifed by the IEC60079-28 standard.A 2-month feld trial at BMA’s Broadmeadow underground mine proved the cabling compatibility to the mine’s existing optical network and the stability of the system performance.Compared with conventional electrically powered gas sensors,this technology bypasses the usual roadblocks of underground gas monitoring where electrical power is either unsafe or unavailable.Furthermore,using one fbre for both power delivery and communication enables longer distance coverage,reduces optical cabling and increases multiplexing possibilities and data throughput for better awareness of underground environment. 展开更多
关键词 Power-over-fbre Ultra-low power consumption Gas monitoring Intrinsic safety Single-mode fbre Optical transducer
下载PDF
Characteristic investigation of permanent magnet actuator for vacuum contactors operating with an intrinsically safe low voltage
4
作者 FANG ShuHua LIN HeYun +2 位作者 Ho SiuLau WANG XianBing JIN Ping 《Science China(Technological Sciences)》 SCIE EI CAS 2012年第6期1688-1694,共7页
This paper reports a new application of permanent magnet actuator for vacuum contactors.A novel permanent magnet(PM) actuator to drive a vacuum contactor with intrinsically safe and low supply voltage is proposed.PM i... This paper reports a new application of permanent magnet actuator for vacuum contactors.A novel permanent magnet(PM) actuator to drive a vacuum contactor with intrinsically safe and low supply voltage is proposed.PM is mounted on the static iron of the contactor to enhance its holding force and reliability.While only one coil is used to break the vacuum contactor,two series coils are deployed to yield a high magnetomotive force to realize the making operation.The electrical circuit equation,mechanical equation and magnetic field are all coupled in the simulation.A prototype is manufactured and tested to validate and showcase the performance of the contactor which is equipped with the proposed PM actuator. 展开更多
关键词 low voltage control permanent magnet actuator intrinsic safety vacuum contactor