BACKGROUND Vascular injury during thoracoscopic surgery for esophageal cancer is a rare but life-threatening complication that can lead to severe hypotension and hypoxemia.Anesthesiologists need to provide rapid and e...BACKGROUND Vascular injury during thoracoscopic surgery for esophageal cancer is a rare but life-threatening complication that can lead to severe hypotension and hypoxemia.Anesthesiologists need to provide rapid and effective treatment to save patients'lives.CASE SUMMARY A 54-year-old male patient was scheduled to undergo a thoracoscopic-assisted radical resection of esophageal cancer through the upper abdomen and right chest.While dissociating the esophagus from the carina through the right chest,unexpected profuse bleeding occurred from a suspected pulmonary vascular hemorrhage.While the surgeon attempted to achieve hemostasis,the patient developed severe hypoxemia.The anesthesiologist implemented continuous positive airway pressure(CPAP)using a bronchial blocker(BB),which effectively improved the patient’s oxygenation and the operation was completed success-fully.CONCLUSION CPAP using a BB can resolve severe hypoxemia caused by accidental injury of the left inferior pulmonary vein during surgery.展开更多
Obstructive sleep apnea syndrome(OSAS)is a relatively common disorder in the adult population.It is associated with alterations in glucose metabolism and increases the risk for diabetes mellitus.Continuous positive ai...Obstructive sleep apnea syndrome(OSAS)is a relatively common disorder in the adult population.It is associated with alterations in glucose metabolism and increases the risk for diabetes mellitus.Continuous positive airway pressure(CPAP)is the treatment of choice for OSAS.It may also have a favorable effect on insulin resistance and glucose metabolism,although relevant data is conflicting.Additional research is still needed to fully establish the effect of CPAP on glucose homeostasis.It should ascertain which patients may benefit most and how long treatment takes to induce favorable changes.Finally,patient compliance is being appreciated as a major factor influencing therapeutic outcomes,and this needs to be further examined.展开更多
This work is aimed at exploring the clinical efficacy of continuous positive airway pressuie(CPAP)in treatment of patients with arrhythmias combined with obstructive sleep apnea(OSA).Through evaluating serum native th...This work is aimed at exploring the clinical efficacy of continuous positive airway pressuie(CPAP)in treatment of patients with arrhythmias combined with obstructive sleep apnea(OSA).Through evaluating serum native thiol,malonaldehyde(MDA)and nicotinamide adenine dinucleotide phosphate oxidase(NADPH oxidase)in these patients and describing the effects on oxidative parameters of CPAP therapy for 3 months,we confirmed the impact of oxidative stress on arrhythmias.A total of 64 patients with OSA combined with arrhythmias were collected from April 2014 to April 2017 with full clinical information.Patients were divided into two groups(paired experiment design):32 patients in group A(control group),who received unchanged anti-arrhythmia treatment and 32 patients in group B,who were subjected to unchanged pharmacological anti-arrhythmia therapy combined with CPAP.OSA related parameters were compared between the two groups after 3-month therapy.And the levels of parameters of oxidative stress in patients were measured before and after CPAP therapy.After 3 months of CPAP therapy,compared with the control group,the percentage of sage N3(NREM 3)and stage R(REM)in total sleep time was significantly increased,while apnea-hypopnea index(AHI)and the Epworth Sleepiness Scale(ESS)score were evidently decreased.Meanwhile,the lowest oxygen saturation(LSpCh)was also elevated after CPAP treatment for 3 months.The CPAP therapy significantly prevented the occurrence of arrhythmias(P<0.05).Both the MDA level and NADPH oxidase levels were significantly lower in the group B than in the group A(P<0.05).But serum native thiol was improved by CPAP treatment(P<0.05).In conclusion,proper use of CPAP therapy provides significant benefits for the treatment of arrhythmia in patients with OSA.展开更多
Obstructive sleep apnea (OSA) and diabetes mellitus are both highly prevalent disorders.There has been a recent recognition of an association between insulin resistance and sleep apnea.Continuous positive airway press...Obstructive sleep apnea (OSA) and diabetes mellitus are both highly prevalent disorders.There has been a recent recognition of an association between insulin resistance and sleep apnea.Continuous positive airway pressure (CPAP) has emerged as an effective therapy for treatment of OSA and has been shown to positively influence numerous pathophysiological factors that con-tribute to cardiovascular risk.There is emerging data that explores the influence of CPAP therapy,insulin sensitivity and glycemic control.In the current review,we examine this literature critically and formulate a synopsis that summarizes the current knowledge in this field.展开更多
The present study aimed to examine the effectiveness of bi-level positive airway pressure(BiPAP)versus continuous positive airway pressure(CPAP)in preterm infants with birth weight less than 1500 g and respiratory dis...The present study aimed to examine the effectiveness of bi-level positive airway pressure(BiPAP)versus continuous positive airway pressure(CPAP)in preterm infants with birth weight less than 1500 g and respiratory distress syndrome(RDS)following intubation-surfactant-extubation(INSURE)treatment.A two-center randomized control trial was performed.The primary outcome was the reintubation rate of infants within 72 h of age after INSURE.Secondary outcomes included bronchopulmonary dysplasia(BPD),necrotizing enterocolitis(NEC),retinopathy of prematurity(ROP)and incidences of adverse events.Lung function at one year of corrected age was also compared between the two groups.There were 140 cases in the CPAP group and 144 in the BiPAP group.After INSURE,the reintubation rates of infants within 72 h of age were 15%and 11.1%in the CPAP group and the BiPAP group,respectively(P>0.05).Neonates in the BiPAP group was on positive airway pressure(PAP)therapy three days less than in the CPAP group(12.6 d and 15.3 d,respectively,P<0.05),and on oxygen six days less than in the CPAP group(20.6 d and 26.9 d,respectively,P<0.05).Other outcomes such as BPD,NEC,ROP and feeding intolerance were not significantly different between the two groups(P>0.05).There was no difference in lung function at one year of age between the two groups(P>0.05).In conclusion,after INSURE,the reintubation rate of infants within 72 h of age was comparable between the BiPAP group and the CPAP group.BiPAP was superior to CPAP in terms of shorter durations(days)on PAP support and oxygen supplementation.There were no differences in the incidences of BPD and ROP,and lung function at one year of age between the two ventilation methods.展开更多
Aim: To assess the efficacy of sildenafil and continuous positive airway pressure (CPAP) in the treatment of concurrent erectile dysfunction (ED) with obstructive sleep apnea (OSA), and to gauge the level of tr...Aim: To assess the efficacy of sildenafil and continuous positive airway pressure (CPAP) in the treatment of concurrent erectile dysfunction (ED) with obstructive sleep apnea (OSA), and to gauge the level of treatment satisfaction in patients and their partners. Methods: Forty men were treated for 12 weeks with sildenafil 100 mg (20 men) or CPAP during nighttime sleep (20 men). Treatment efficacy was assessed by the rate of successful intercourse attempts, and satisfaction with treatment was assessed by patients' and partners' answers to question 1 of the Erectile Dysfunction Inventory of Treatment Satisfaction. Results: Under sildenafil, 128 of 249 (51.4%) intercourse attempts were successful; under CPAP, 51 of 193 (26.9%) attempts were successful (^cp 〈 0.001). Erectile function was improved in both groups. After sildenafil and CPAP treatment, the mean International Index for Erectile Function domain scores were 14.3 and 10.8, respectively (^bp = 0.025), compared to 7.8 and 7 at baseline, respectively. CPAP and sildenafil were well tolerated. Sporadic episodes of nasal dryness under CPAP and transient headache and flushing under sildenafil were not significant. Fifty percent of patients treated with sildenafil and 25% with CPAP were satisfied with the treatment, and their partners were equally satisfied. The satisfaction scores for both patients and partners under sildenafil were superior to those under CPAP (^cP 〈 0.002). Conclusion: Both sildenafil 100 mg and CPAP, used separately, had positive therapeutic impact but sildenafil was superior. Patients and their partners were more satisfied with sildenafil for the treatment of ED. However, because of the high proportion of dissatisfied men and partners, new therapeutic agents or a combination of the two methods must be studied further.展开更多
BACKGROUND: To determine whether the prehospital use of continuous positive airway pressure(CPAP) therapy is associated with a reduced rate of endotracheal intubation in patients with an acute respiratory disorder bro...BACKGROUND: To determine whether the prehospital use of continuous positive airway pressure(CPAP) therapy is associated with a reduced rate of endotracheal intubation in patients with an acute respiratory disorder brought to the emergency department(ED).METHODS: We reviewed medical records of patients with acute respiratory distress who had been treated with CPAP in the Mobile Intensive Care Unit(MICU) from January 2010 to December 2011. These records were compared with those of patients who received standardized care without CPAP in the MICU from January 2004 to December 2004. Categorical variables were summarized as frequencies and compared between groups using Fisher's exact test or the Chi-square test. Continuous variables were summarized as medians(interquartile range), and comparison between the groups was made using Wilcoxon's rank-sum test. The relationship between CPAP and intubation rate was determined using multivariable logistic regression analysis of propensity scores. The results were presented as odds ratio(OR), 95% confidence interval(CI), and P value for test effect. The adequacy of the model was calibrated using Hosmer and Lemeshow's goodness-of-fit test. P<0.05 was considered statistically significant.RESULTS: The records of 785 patients were reviewed. Of the 215 patients treated with CPAP in the MICU, 13% were intubated after admission. In contrast, of the 570 patients who did not receive CPAP, 28% were intubated after ED admission. Unadjusted logistic regression analysis showed that patients who had been treated with CPAP were less likely to be intubated than those without CPAP treatment(OR=0.37, 95% CI, 0.24–0.57, P<0.0001). With propensity scores adjusted, multivariate logistic regression analysis showed that CPAP treatment was associated with a 62% reduction of intubation(OR=0.384, 95%CI, 0.25–0.60, P≤0.0001).CONCLUSIONS: In patients with acute respiratory disorder, there was a relationship between CPAP therapy and the decreased intubation rate. CPAP therapy was feasible in prehospital management of patients with respiratory distress.展开更多
BACKGROUND Obstructive sleep apnea(OSA)has been suggested as an independent risk factor for nonalcoholic fatty liver disease(NAFLD),and continuous positive airway pressure(CPAP)is the first-line therapy for OSA.AIM To...BACKGROUND Obstructive sleep apnea(OSA)has been suggested as an independent risk factor for nonalcoholic fatty liver disease(NAFLD),and continuous positive airway pressure(CPAP)is the first-line therapy for OSA.AIM To clarify the efficacy of effective CPAP therapy on NAFLD of OSA patients by serum markers and transient elastography(TE)using FibroScan®(Echosens,Paris,France).METHODS We prospectively enrolled 123 consecutive patients with OSA who met the indications for CPAP.Liver fibrosis and steatosis were assessed using TE.Before and after 6 mo of CPAP therapy,serum markers and TE were assessed for all patients.The mean usage rate of CPAP therapy for 6 mo was arbitrarily calculated in each patient and expressed as“mean compliance index”(m-CI).RESULTS In 50 OSA patients with NAFLD,both aspartate aminotransferase(AST)and alanine aminotransferase(ALT)levels were significantly decreased after 6 mo of CPAP therapy.Univariate analysis showed that decreased body weight(BW),decreased body mass index(BMI),decreased AST level,decreased hemoglobin A1c,and high m-CI were significantly related with improved ALT level.In multivariate regression model adjusted for quantities of BW change during 6 mo of CPAP therapy,high m-CI tended to improve ALT level(P=0.051).All 17 OSA patients with NAFLD,high m-CI and no BMI changes showed significant improvements in AST and ALT levels.Meanwhile,no significant changes in TE data or serum fibrosis markers were seen.CONCLUSION Some NAFLD could be associated with chronic intermittent hypoxia due to OSA independent of BW changes.In those cases,adequate reoxygenation from effective CPAP therapy may improve NAFLD.展开更多
Objective To determine whether sleep-disordered breathing (SDB) may lead to nocturnal myocardial ischemia and whether the severity of this ischemia may be relieved by nasal continuous positive airway pressure (CPAP). ...Objective To determine whether sleep-disordered breathing (SDB) may lead to nocturnal myocardial ischemia and whether the severity of this ischemia may be relieved by nasal continuous positive airway pressure (CPAP). Methods Overnight polysomnogram examination and simultaneous 3-channel Holter monitoring were performed on 76 patients with moderate to severe SDB and no history of coronary heart disease. All the cases were treated with CPAP for one night. ST depression was defined as a ST segment decrease of more than 1 mm from baseline and lasting 1 min or more. The total duration (minutes) of ST depression was indexed to the total sleep time (minutes per hour of sleep). Results Twenty-eight patients (37%) showed ST segment depression during their sleep. Before CPAP treatment, the respiratory disturbance index (RDI) and arousal index were significantly higher during periods of ST depression than when ST segments were isoelectric, whereas no significant difference was found in blood oxygen saturation (SaO2). After the CPAP treatment of patients with ST depression, the duration of ST depression was significantly reduced from 36.8±18.9 to 11.4±13.2 min/h (P<0.05). ST depression-related indexes, including RDI, arousal index and the percentage of sleep time spent at SaO2 below 90% (TS90/ TST), were all significantly decreased, with RDI from 63.4±23.8 to 8.1±6.6 /h, arousal index from 51.2±18.9 to 9.6±5.4 /h, and TS90/ TST from 50.6±21.4 to 12.9±14.7% (P<0.05). Conclusion ST-segment depression is rather common in patients with moderate to severe SDB, and CPAP treatment can significantly reduce the duration of ST depression. ST depression in these patients may reflect the myocardial ischemia that really exists and the non-ischemic changes associated with recurrent SDB.展开更多
Objective: To investigate the clinical effects of the mask continuous positive airway pressure (CPAP) mechanical ventilation in children with severe pneumonia. Methods: A total of 100 cases of children with severe pne...Objective: To investigate the clinical effects of the mask continuous positive airway pressure (CPAP) mechanical ventilation in children with severe pneumonia. Methods: A total of 100 cases of children with severe pneumonia were randomly divided into two groups, study group with 50 children and control group with 50 children. These 100 children were given comprehensive treatment measures: treatment of anti-infection, anti-respiratory failure, anti-heart failure (if necessary), relieving cough and reducing sputum, aerosol inhalation, limited fluid volume, nutrition support etc. Children in the study group were added mask continuous positive airway pressure mechanical ventilation (CPAP). Children in the control group were added ordinary mask oxygen inhalation. Investigated and checked the treatment effect in these two groups. Results: After treatment, SaO2, PaO2 in both two groups were showed significantly higher than before the treatment. PaO2 of the study group is obviously higher than the control group. The oxygen inhalation time of the study group was obviously lesser than the control group. The total effective rate of the study group was significantly higher than the control group which was 96.0% vs 66.0%. Conclusion: The mask continuous positive airway pressure (CPAP) mechanical ventilation can significantly improve the related symptoms and blood gas status of the children with severe pneumonia, shorten the oxygen inhalation time and had remarkable effect.展开更多
Background: Previous studies of continuous positive airway pressure (CPAP) treatment for obstructive sleep apnoea (OSA) have shown conflicting results on the effect on blood pressure (BP), and patients with chronic ki...Background: Previous studies of continuous positive airway pressure (CPAP) treatment for obstructive sleep apnoea (OSA) have shown conflicting results on the effect on blood pressure (BP), and patients with chronic kidney disease (CKD) have not been included in these studies. As OSA is a frequent comorbidity in patients with CKD, it is of relevance to evaluate the effect of CPAP treatment on BP in this population. Aim: In this prospective follow-up study, we measured the effect of short term CPAP treatment of moderate-to-severe OSA on brachial and central BP, plasma level of syndecan-1 and vasoactive hormones, renal handling of sodium, subjective sleepiness, and quality of life in patients with impaired renal function. Methods: From December 2015 until March 2017, 25 patients were invited to participate in the study at the University Clinic in Nephrology and Hypertension, Aarhus University and Holstebro Hospital. At baseline and at follow-up after three to four months of CPAP treatment, we performed 24 h brachial and central ambulatory BP measurement, blood sampling measurements of plasma concentrations of syndecan-1, renin, angiotensin II, aldosterone, vasopressin, creatinine, haemoglobin A1c, and cholesterol, cardio respiratory monitoring, 24 h urine collection for measurement of urinary excretion of albumin, aquaporin-2, and epithelial sodium channel, Epworth Sleepiness Scale (ESS), and SF-36 (quality of life). Results: At follow-up, the 17 included patients with mean baseline estimated glomerular filtration rate 66 mL/min/1.73 m2 had a significant decrease in systolic office-, 24 h- and daytime-BP (13, 7, and 8 mmHg, respectively, p Conclusion: Short-term CPAP treatment of patients with moderate-to-severe OSA and reduced renal function decreased 24 h- and daytime-BP significantly and reduced urinary albumin excretion. Our results underline the importance of treatment of OSA in hypertensive patients with impaired renal function.展开更多
Introduction: Positive airway pressure (PAP) therapy is the gold-standard for obstructive sleep apnea (OSA) management. While it is known that PAP is efficacious for controlling breathing events during sleep when it i...Introduction: Positive airway pressure (PAP) therapy is the gold-standard for obstructive sleep apnea (OSA) management. While it is known that PAP is efficacious for controlling breathing events during sleep when it is worn at the right pressure for the amount of time prescribed, there is less clear data on how well it improves sleep quality. There are few studies that have examined the effectiveness of PAP therapy on sleep quality. Methods: OSA participants (n = 241) from a larger trial examining a PAP adherence were included. Participants were provided with PAP instruction and followed at 2 months and 4 months. PAP adherence was measured as the number of hours per night at prescribed pressure, an objective measure of treatment adherence. The Pittsburgh Sleep Quality Index (PSQI) was used as the primary measure of sleep quality. Results: The PSQI was significantly correlated with PAP adherence at both the 2-month and 4-month time points, such that lower sleep quality was associated with lower PAP use. This finding held for the sleep disturbance subscale of the PSQI. Over 55% of those using PAP therapy at the 4-month time point continued to report significantly disturbed sleep. Discussion: This study shows that PAP therapy does not appear to improve sleep quality to a degree that would be expected. Over half of those patients using PAP therapy still experienced disturbed sleep. Whether the disturbed sleep is directly attributable to the PAP device itself or to disturbed sleep secondary to uncontrolled OSA when PAP is not worn is worthy of further investigation.展开更多
Objective: Research was conducted to examine benefits to using non-invasive ventilation (NIV) or continuous positive airway pressure (CPAP) early in the treatment of respiratory distress caused by pulmonary edema, chr...Objective: Research was conducted to examine benefits to using non-invasive ventilation (NIV) or continuous positive airway pressure (CPAP) early in the treatment of respiratory distress caused by pulmonary edema, chronic obstructive pulmonary disease (COPD) and asthma. Limitations to successful NIV and CPAP therapy were evaluated to determine how prolonged initiation of treatment may lead to hypoxemia (decreased oxygen in the blood) and hypercapnia (increased carbon dioxide in the blood) resulting in poor outcomes. Method: Reviews of literature from nursing and allied health data bases (CINAHL and ProQuest) with terms pulmonary edema, positive pressure device and non-invasive ventilation from 2010 to 2014 were used. Studies were conducted in the hospital and prehospital settings. Results: The literature search located 7 articles from CINAHL and 25 articles from ProQuest. A total of 6 of these articles were analyzed. Additional sources of data were obtained from Ignatavicius and Workman (2013) Medical-Surgical Nursing Patient-Centered Collaborative Care 7th edition and American Journal of Nursing (02/2013) Volume 113: 2. Conclusion: All of the articles concluded that early initiation of continuous positive airway pressure ventilations in the short-term was beneficial;however, late initiation of therapy required additional interventions. The studies indicated that early use of positive airway pressure in acute respiratory distress improved breath rate, heart rate and blood pressure. The use of positive airway pressure for respiratory distress may decrease the need for endotracheal intubation.展开更多
Background: For patients with obstructive sleep apnea-hypopnea syndrome (OSAHS) and type 2 diabetes mellitus (T2DM), the night sleep interruption and intermittent hypoxia due to apnea or hypopnea may induce glyce...Background: For patients with obstructive sleep apnea-hypopnea syndrome (OSAHS) and type 2 diabetes mellitus (T2DM), the night sleep interruption and intermittent hypoxia due to apnea or hypopnea may induce glycemic excursions and reduce insulin sensitivity. This study aimed to investigate the effect of continuous positive airway pressure (CPAP) therapy in patients with OSAHS and T2DM. Methods: Continuous glucose monitoring system (CGMS) was used in 40 patients with T2DM and newly diagnosed OSAHS. The measurements were repeated after 30 days of CPAP treatment. Subsequently, insulin sensitivity and glycohemoglobin (HbAlc) were measured and compared to the pretreatment data. Results: After CPAP therapy, the CGMS indicators showed that the 24-h mean blood glucose (MBG) and the night time MBG were significantly reduced (P 〈 0.05 and P = 0.03, respectively). The mean ambulatory glucose excursions (MAGEs) and the mean of daily differences were also significantly reduced (P 〈 0.05 and P = 0.002, respectively) compared to pretreatment levels. During the night, MAGE also significantly decreased (P = 0.049). The differences between the highest and lowest levels of blood glucose over 24 h and during the night were significantly lower than prior to CPAP treatment (P 〈 0.05 and P = 0.024, respectively). The 24 h and night time durations of high blood glucose (〉7.8 mmol/L and 〉 11.1 mmol/L) decreased (P 〈 0.05 and P 〈 0.05, respectively) after the treatment. In addition, HbA 1 c levels were also lower than those before treatment (P 〈 0.05), and the homeostasis model assessment index of insulin resistance was also significantly lower than before CPAP treatment (P = 0.034). Conclusions: CPAP therapy may have a beneficial effect on improving not only blood glucose but also upon insulin sensitivity in T2DM patients with OSAHS. This suggests that CPAP may be an effective treatment for T2DM in addition to intensive diabetes management.展开更多
Background Recent research suggested that obstructive sleep apnea syndrome (OSAS) might be independently associated with hypoadiponectinemia, which was linked to some complications of OSAS, such as hypertension, dia...Background Recent research suggested that obstructive sleep apnea syndrome (OSAS) might be independently associated with hypoadiponectinemia, which was linked to some complications of OSAS, such as hypertension, diabetes etc. This study was conducted to investigate the effect of continuous positive airway pressure (CPAP) treatment on changes of both serum adiponectin levels and mean arterial pressure and their possible links in male OSAS patients. Methods Twenty-three adult male patients with moderate-to-severe OSAS but without obesity, coronary heart disease and diabetes were recruited. Their blood samples were collected and morning mean arterial pressure (MAP) was measured before CPAP treatment and on day 3, 7, 14 of CPAP treatment respectively. The serum adiponectin concentration was tested with radioimmunoassay. Results Compared with the serum adiponectin level before CPAP treatment, no significant change was found in OSAS patients on day 3 and day 7 of CPAP treatment (P〉0.05). It was not until day 14 of CPAP treatment did a significant elevation in serum adiponectin level occur (P〈0.01). Meanwhile, the MAP showed no statistically significant difference among its levels before CPAP, on day 3 and day 7 of CPAP treatment (P〉0.05). However, on day 14 of CPAP treatment, a significantly lower MAP than that obtained before treatment was observed (P〈0.05). Conclusions CPAP treatment can gradually reverse hypoadiponectinemia and reduce MAP in OSAS patients. Hypoadiponectinemia might be involved in the pathogenesis of OSAS-mediated hypertension.展开更多
Background: Current views on continuous positive airway pressure (CPAP) treatment to improve the cognitive deficits of patients with obstructive sleep apnea syndrome (OSAS) are controversial, so we performed a me...Background: Current views on continuous positive airway pressure (CPAP) treatment to improve the cognitive deficits of patients with obstructive sleep apnea syndrome (OSAS) are controversial, so we performed a meta-analysis. Methods: A comprehensive literature search was undertaken in PubMed, CINAHL, Medline, Psyclnfo, EMBASE, Cochrane Library, CNKI, WanFang, VIP, and CBMdisc for studies published from June 1971 to July 2014. The outcome measures included neuropsychological tests of the 7 cognitive domains detailed below. Results: After screening the titles and abstracts and thoroughly reading the fuU text, we obtained 13 studies with little risk of bias that incorporated 1744 middle-aged obese participants with mild to severe OSAS. The studies were published from 1994 to 2012. Treatment durations varied from 1 to 24 weeks. The effect sizes of attention, vigilance, processing speed, working memory, memory, verbal fluency, and visuoconstructive skills domains were -0.10 (P = 0.24), -0.12 (P = 0.04), -0.08 (P = 0.16), 0.00 (P = 0.95), -0.04 (P = 0.30), -0.06 (P = 0.34), and -0.01 (P = 0.92), respectively. Conclusions: Cognition partially improved in patients with OSAS after CPAP treatment. The only domain with significant improvement was vigilance. Rigorous randomized controlled trials need to be performed to obtain clear results.展开更多
Obstructive sleep apnea (OSA), which is the most common sleep-related breathing disorder and characterized by recurrent collapse of the upper airway, causes repeated arousals from sleep, decreased oxygen saturation ...Obstructive sleep apnea (OSA), which is the most common sleep-related breathing disorder and characterized by recurrent collapse of the upper airway, causes repeated arousals from sleep, decreased oxygen saturation of the blood, and excessive daytime sleepiness. Patients with OSA are at increased risk of cardiovascular and cerebrovascular disease,展开更多
Background Continuous positive airway pressure (CPAP) treatment has been proven to be effective in improving the symptoms of coexisting coronary heart disease (CHD) in patients with obstructive sleep apnea hypopnea sy...Background Continuous positive airway pressure (CPAP) treatment has been proven to be effective in improving the symptoms of coexisting coronary heart disease (CHD) in patients with obstructive sleep apnea hypopnea syndrome (OSAHS). However,it is still unclear whether such improvements are linked to changes in vascular endothelial function. This research was carried out to investigate the effects of CPAP treatment on vascular endothelial function in patients with OSAHS and CHD.Methods Thirty-six patients with moderate or severe OSAHS and CHD undergoing three months of CPAP treatment were recruited for this study. The changes in their morning plasma nitric oxide (NO) and endothelin (ET) levels,NO/ET ratio,total ischemic burden (TIB) of the myocardium,apnea hypopnea index (AHI),and minimal and mean pulse oxygen saturation (SpO_2) were compared and analyzed before and during CPAP treatment. Results Compared with the plasma levels of ET [(51.39±11.69) ng/L] and NO [(36.67±11.86) μmol/L],NO/ET (0.71±0.14),AHI (32.4±7.9),minimal SpO_2 [(68.9±11.4)%],and myocardial TIB [(66.29±16.37) mm·min] before treatment,there were significant decreases in ET [(33.41±10.03) ng/L] ( P <0.05),increases in NO [(59.89±10.26) μmol/L] and NO/ET (1.79±0.38) ( P <0.01),decreases in AHI (1.9±0.5),and increases in minimal SpO_2 [(90.6±1.8) %] (all P <0.01) and myocardial TIB [(36.42±10.87) mm·min] ( P <0.05) after three months of CPAP treatment.Conclusion CPAP treatment may play an important role in the improvement and protection of vascular endothelial dysfunction and myocardial ischemia in OSAHS patients with CHD.展开更多
Objectives To characterize the prethrombotic state ( PTS) in elderly Chinese patients with obstructive sleep apnea hypopnea syndrome (OSAHS) and the effect of nasal continuous positive airway pressure (nCPAP) ventilat...Objectives To characterize the prethrombotic state ( PTS) in elderly Chinese patients with obstructive sleep apnea hypopnea syndrome (OSAHS) and the effect of nasal continuous positive airway pressure (nCPAP) ventilation on their PTS.Methods Forty-one elderly patients with moderate and severe OSAHS were enrolled into the OSAHS group and underwent nCPAP treatment. Their blood samples were drawn at 6:00 am and 4:00 pm before and during nCPAP treatment, respectively, to test hemocrit, platelet aggregation (PAG), whole blood viscosity (WBV), plasma fibrinogen (fng), prothrombin time (PT) and activated partial thromboplastin time (APTT). All blood factors were also tested in a control group consisting of 32 healthy elderly Chinese with neither OSAHS nor cerebrocardiac vascular disease.Results In the OSAHS group there was a significantly higher hemocrit, WBV, fng, and a significantly shorter PT and APTT at 6:00 am compared to 4:00 pm before nCPAP treatment, while there was no significant difference among all blood test factors between 6:00 am and 4:00 pm on day 30 of the nCPAP treatment. In the OSAHS group, the hemocrit, WBV, PAG and plasma fng were significantly lower and the PT and APTT were significantly longer at 6:00 am on day 30 of the nCPAP treatment compared to 6:00 am before the nCPAP treatment. A significantly lower hemocrit, but a much longer PT and APTT were observed at 4:00 pm on day 30 of the treatment, compared with 4:00 pm before the treatment. No significant difference among the blood test factors was found between 6:00 am and 4:00 pm blood in the control group or between the control and OSAHS groups after 30 days of nCPAP treatment.Conclusion In elderly Chinese OSAHS patients, PTS could be effectively eliminated by nCPAP treatment.展开更多
Background Obesity is a common risk factor for several diseases. Obesity related hormone and increased insulin resistance (IR) may contribute to the effects of obstructive sleep apnoea on cardiovascular consequences...Background Obesity is a common risk factor for several diseases. Obesity related hormone and increased insulin resistance (IR) may contribute to the effects of obstructive sleep apnoea on cardiovascular consequences. We investigated ghrelin and IR in non-diabetic apnoeic patients with stable coronary heart disease and assessed the effects of continuous positive airway pressure (CPAP). Methods Plasma ghrelin, glucose and insulin were measured in 22 patients with CPAP and 22 matched controls without CPAP at baseline and three months. Indexes including homeostasis model assessment IR (HOMA IR), HOMA S and HOMA β were calculated for the assessment of IR, insulin sensitivity and pancreatic β cell function. Results At three months follow-up, plasma ghrelin levels and HOMA IR in CPAP group were significantly decreased (P=0.002 and 0.046, respectively) while those in control group increased significantly (P=0.012 and 0.009, respectively). Significant moderate correlations were found between ghrelin vs. HOMA IR and ghrelin vs. HOMA S after CPAP, however, for those without CPAP, no significant associations were observed. Conclusions Short-term effective continuous positive airway pressure had a significant effect on lowering plasma ghrelin levels and IR, but not body fat. Further large scale and longer term studies are warranted to corroborate these findings.展开更多
文摘BACKGROUND Vascular injury during thoracoscopic surgery for esophageal cancer is a rare but life-threatening complication that can lead to severe hypotension and hypoxemia.Anesthesiologists need to provide rapid and effective treatment to save patients'lives.CASE SUMMARY A 54-year-old male patient was scheduled to undergo a thoracoscopic-assisted radical resection of esophageal cancer through the upper abdomen and right chest.While dissociating the esophagus from the carina through the right chest,unexpected profuse bleeding occurred from a suspected pulmonary vascular hemorrhage.While the surgeon attempted to achieve hemostasis,the patient developed severe hypoxemia.The anesthesiologist implemented continuous positive airway pressure(CPAP)using a bronchial blocker(BB),which effectively improved the patient’s oxygenation and the operation was completed success-fully.CONCLUSION CPAP using a BB can resolve severe hypoxemia caused by accidental injury of the left inferior pulmonary vein during surgery.
文摘Obstructive sleep apnea syndrome(OSAS)is a relatively common disorder in the adult population.It is associated with alterations in glucose metabolism and increases the risk for diabetes mellitus.Continuous positive airway pressure(CPAP)is the treatment of choice for OSAS.It may also have a favorable effect on insulin resistance and glucose metabolism,although relevant data is conflicting.Additional research is still needed to fully establish the effect of CPAP on glucose homeostasis.It should ascertain which patients may benefit most and how long treatment takes to induce favorable changes.Finally,patient compliance is being appreciated as a major factor influencing therapeutic outcomes,and this needs to be further examined.
文摘This work is aimed at exploring the clinical efficacy of continuous positive airway pressuie(CPAP)in treatment of patients with arrhythmias combined with obstructive sleep apnea(OSA).Through evaluating serum native thiol,malonaldehyde(MDA)and nicotinamide adenine dinucleotide phosphate oxidase(NADPH oxidase)in these patients and describing the effects on oxidative parameters of CPAP therapy for 3 months,we confirmed the impact of oxidative stress on arrhythmias.A total of 64 patients with OSA combined with arrhythmias were collected from April 2014 to April 2017 with full clinical information.Patients were divided into two groups(paired experiment design):32 patients in group A(control group),who received unchanged anti-arrhythmia treatment and 32 patients in group B,who were subjected to unchanged pharmacological anti-arrhythmia therapy combined with CPAP.OSA related parameters were compared between the two groups after 3-month therapy.And the levels of parameters of oxidative stress in patients were measured before and after CPAP therapy.After 3 months of CPAP therapy,compared with the control group,the percentage of sage N3(NREM 3)and stage R(REM)in total sleep time was significantly increased,while apnea-hypopnea index(AHI)and the Epworth Sleepiness Scale(ESS)score were evidently decreased.Meanwhile,the lowest oxygen saturation(LSpCh)was also elevated after CPAP treatment for 3 months.The CPAP therapy significantly prevented the occurrence of arrhythmias(P<0.05).Both the MDA level and NADPH oxidase levels were significantly lower in the group B than in the group A(P<0.05).But serum native thiol was improved by CPAP treatment(P<0.05).In conclusion,proper use of CPAP therapy provides significant benefits for the treatment of arrhythmia in patients with OSA.
文摘Obstructive sleep apnea (OSA) and diabetes mellitus are both highly prevalent disorders.There has been a recent recognition of an association between insulin resistance and sleep apnea.Continuous positive airway pressure (CPAP) has emerged as an effective therapy for treatment of OSA and has been shown to positively influence numerous pathophysiological factors that con-tribute to cardiovascular risk.There is emerging data that explores the influence of CPAP therapy,insulin sensitivity and glycemic control.In the current review,we examine this literature critically and formulate a synopsis that summarizes the current knowledge in this field.
文摘The present study aimed to examine the effectiveness of bi-level positive airway pressure(BiPAP)versus continuous positive airway pressure(CPAP)in preterm infants with birth weight less than 1500 g and respiratory distress syndrome(RDS)following intubation-surfactant-extubation(INSURE)treatment.A two-center randomized control trial was performed.The primary outcome was the reintubation rate of infants within 72 h of age after INSURE.Secondary outcomes included bronchopulmonary dysplasia(BPD),necrotizing enterocolitis(NEC),retinopathy of prematurity(ROP)and incidences of adverse events.Lung function at one year of corrected age was also compared between the two groups.There were 140 cases in the CPAP group and 144 in the BiPAP group.After INSURE,the reintubation rates of infants within 72 h of age were 15%and 11.1%in the CPAP group and the BiPAP group,respectively(P>0.05).Neonates in the BiPAP group was on positive airway pressure(PAP)therapy three days less than in the CPAP group(12.6 d and 15.3 d,respectively,P<0.05),and on oxygen six days less than in the CPAP group(20.6 d and 26.9 d,respectively,P<0.05).Other outcomes such as BPD,NEC,ROP and feeding intolerance were not significantly different between the two groups(P>0.05).There was no difference in lung function at one year of age between the two groups(P>0.05).In conclusion,after INSURE,the reintubation rate of infants within 72 h of age was comparable between the BiPAP group and the CPAP group.BiPAP was superior to CPAP in terms of shorter durations(days)on PAP support and oxygen supplementation.There were no differences in the incidences of BPD and ROP,and lung function at one year of age between the two ventilation methods.
文摘Aim: To assess the efficacy of sildenafil and continuous positive airway pressure (CPAP) in the treatment of concurrent erectile dysfunction (ED) with obstructive sleep apnea (OSA), and to gauge the level of treatment satisfaction in patients and their partners. Methods: Forty men were treated for 12 weeks with sildenafil 100 mg (20 men) or CPAP during nighttime sleep (20 men). Treatment efficacy was assessed by the rate of successful intercourse attempts, and satisfaction with treatment was assessed by patients' and partners' answers to question 1 of the Erectile Dysfunction Inventory of Treatment Satisfaction. Results: Under sildenafil, 128 of 249 (51.4%) intercourse attempts were successful; under CPAP, 51 of 193 (26.9%) attempts were successful (^cp 〈 0.001). Erectile function was improved in both groups. After sildenafil and CPAP treatment, the mean International Index for Erectile Function domain scores were 14.3 and 10.8, respectively (^bp = 0.025), compared to 7.8 and 7 at baseline, respectively. CPAP and sildenafil were well tolerated. Sporadic episodes of nasal dryness under CPAP and transient headache and flushing under sildenafil were not significant. Fifty percent of patients treated with sildenafil and 25% with CPAP were satisfied with the treatment, and their partners were equally satisfied. The satisfaction scores for both patients and partners under sildenafil were superior to those under CPAP (^cP 〈 0.002). Conclusion: Both sildenafil 100 mg and CPAP, used separately, had positive therapeutic impact but sildenafil was superior. Patients and their partners were more satisfied with sildenafil for the treatment of ED. However, because of the high proportion of dissatisfied men and partners, new therapeutic agents or a combination of the two methods must be studied further.
文摘BACKGROUND: To determine whether the prehospital use of continuous positive airway pressure(CPAP) therapy is associated with a reduced rate of endotracheal intubation in patients with an acute respiratory disorder brought to the emergency department(ED).METHODS: We reviewed medical records of patients with acute respiratory distress who had been treated with CPAP in the Mobile Intensive Care Unit(MICU) from January 2010 to December 2011. These records were compared with those of patients who received standardized care without CPAP in the MICU from January 2004 to December 2004. Categorical variables were summarized as frequencies and compared between groups using Fisher's exact test or the Chi-square test. Continuous variables were summarized as medians(interquartile range), and comparison between the groups was made using Wilcoxon's rank-sum test. The relationship between CPAP and intubation rate was determined using multivariable logistic regression analysis of propensity scores. The results were presented as odds ratio(OR), 95% confidence interval(CI), and P value for test effect. The adequacy of the model was calibrated using Hosmer and Lemeshow's goodness-of-fit test. P<0.05 was considered statistically significant.RESULTS: The records of 785 patients were reviewed. Of the 215 patients treated with CPAP in the MICU, 13% were intubated after admission. In contrast, of the 570 patients who did not receive CPAP, 28% were intubated after ED admission. Unadjusted logistic regression analysis showed that patients who had been treated with CPAP were less likely to be intubated than those without CPAP treatment(OR=0.37, 95% CI, 0.24–0.57, P<0.0001). With propensity scores adjusted, multivariate logistic regression analysis showed that CPAP treatment was associated with a 62% reduction of intubation(OR=0.384, 95%CI, 0.25–0.60, P≤0.0001).CONCLUSIONS: In patients with acute respiratory disorder, there was a relationship between CPAP therapy and the decreased intubation rate. CPAP therapy was feasible in prehospital management of patients with respiratory distress.
基金the Japan Society for the Promotion of Science,No.JP16K09564.
文摘BACKGROUND Obstructive sleep apnea(OSA)has been suggested as an independent risk factor for nonalcoholic fatty liver disease(NAFLD),and continuous positive airway pressure(CPAP)is the first-line therapy for OSA.AIM To clarify the efficacy of effective CPAP therapy on NAFLD of OSA patients by serum markers and transient elastography(TE)using FibroScan®(Echosens,Paris,France).METHODS We prospectively enrolled 123 consecutive patients with OSA who met the indications for CPAP.Liver fibrosis and steatosis were assessed using TE.Before and after 6 mo of CPAP therapy,serum markers and TE were assessed for all patients.The mean usage rate of CPAP therapy for 6 mo was arbitrarily calculated in each patient and expressed as“mean compliance index”(m-CI).RESULTS In 50 OSA patients with NAFLD,both aspartate aminotransferase(AST)and alanine aminotransferase(ALT)levels were significantly decreased after 6 mo of CPAP therapy.Univariate analysis showed that decreased body weight(BW),decreased body mass index(BMI),decreased AST level,decreased hemoglobin A1c,and high m-CI were significantly related with improved ALT level.In multivariate regression model adjusted for quantities of BW change during 6 mo of CPAP therapy,high m-CI tended to improve ALT level(P=0.051).All 17 OSA patients with NAFLD,high m-CI and no BMI changes showed significant improvements in AST and ALT levels.Meanwhile,no significant changes in TE data or serum fibrosis markers were seen.CONCLUSION Some NAFLD could be associated with chronic intermittent hypoxia due to OSA independent of BW changes.In those cases,adequate reoxygenation from effective CPAP therapy may improve NAFLD.
文摘Objective To determine whether sleep-disordered breathing (SDB) may lead to nocturnal myocardial ischemia and whether the severity of this ischemia may be relieved by nasal continuous positive airway pressure (CPAP). Methods Overnight polysomnogram examination and simultaneous 3-channel Holter monitoring were performed on 76 patients with moderate to severe SDB and no history of coronary heart disease. All the cases were treated with CPAP for one night. ST depression was defined as a ST segment decrease of more than 1 mm from baseline and lasting 1 min or more. The total duration (minutes) of ST depression was indexed to the total sleep time (minutes per hour of sleep). Results Twenty-eight patients (37%) showed ST segment depression during their sleep. Before CPAP treatment, the respiratory disturbance index (RDI) and arousal index were significantly higher during periods of ST depression than when ST segments were isoelectric, whereas no significant difference was found in blood oxygen saturation (SaO2). After the CPAP treatment of patients with ST depression, the duration of ST depression was significantly reduced from 36.8±18.9 to 11.4±13.2 min/h (P<0.05). ST depression-related indexes, including RDI, arousal index and the percentage of sleep time spent at SaO2 below 90% (TS90/ TST), were all significantly decreased, with RDI from 63.4±23.8 to 8.1±6.6 /h, arousal index from 51.2±18.9 to 9.6±5.4 /h, and TS90/ TST from 50.6±21.4 to 12.9±14.7% (P<0.05). Conclusion ST-segment depression is rather common in patients with moderate to severe SDB, and CPAP treatment can significantly reduce the duration of ST depression. ST depression in these patients may reflect the myocardial ischemia that really exists and the non-ischemic changes associated with recurrent SDB.
文摘Objective: To investigate the clinical effects of the mask continuous positive airway pressure (CPAP) mechanical ventilation in children with severe pneumonia. Methods: A total of 100 cases of children with severe pneumonia were randomly divided into two groups, study group with 50 children and control group with 50 children. These 100 children were given comprehensive treatment measures: treatment of anti-infection, anti-respiratory failure, anti-heart failure (if necessary), relieving cough and reducing sputum, aerosol inhalation, limited fluid volume, nutrition support etc. Children in the study group were added mask continuous positive airway pressure mechanical ventilation (CPAP). Children in the control group were added ordinary mask oxygen inhalation. Investigated and checked the treatment effect in these two groups. Results: After treatment, SaO2, PaO2 in both two groups were showed significantly higher than before the treatment. PaO2 of the study group is obviously higher than the control group. The oxygen inhalation time of the study group was obviously lesser than the control group. The total effective rate of the study group was significantly higher than the control group which was 96.0% vs 66.0%. Conclusion: The mask continuous positive airway pressure (CPAP) mechanical ventilation can significantly improve the related symptoms and blood gas status of the children with severe pneumonia, shorten the oxygen inhalation time and had remarkable effect.
文摘Background: Previous studies of continuous positive airway pressure (CPAP) treatment for obstructive sleep apnoea (OSA) have shown conflicting results on the effect on blood pressure (BP), and patients with chronic kidney disease (CKD) have not been included in these studies. As OSA is a frequent comorbidity in patients with CKD, it is of relevance to evaluate the effect of CPAP treatment on BP in this population. Aim: In this prospective follow-up study, we measured the effect of short term CPAP treatment of moderate-to-severe OSA on brachial and central BP, plasma level of syndecan-1 and vasoactive hormones, renal handling of sodium, subjective sleepiness, and quality of life in patients with impaired renal function. Methods: From December 2015 until March 2017, 25 patients were invited to participate in the study at the University Clinic in Nephrology and Hypertension, Aarhus University and Holstebro Hospital. At baseline and at follow-up after three to four months of CPAP treatment, we performed 24 h brachial and central ambulatory BP measurement, blood sampling measurements of plasma concentrations of syndecan-1, renin, angiotensin II, aldosterone, vasopressin, creatinine, haemoglobin A1c, and cholesterol, cardio respiratory monitoring, 24 h urine collection for measurement of urinary excretion of albumin, aquaporin-2, and epithelial sodium channel, Epworth Sleepiness Scale (ESS), and SF-36 (quality of life). Results: At follow-up, the 17 included patients with mean baseline estimated glomerular filtration rate 66 mL/min/1.73 m2 had a significant decrease in systolic office-, 24 h- and daytime-BP (13, 7, and 8 mmHg, respectively, p Conclusion: Short-term CPAP treatment of patients with moderate-to-severe OSA and reduced renal function decreased 24 h- and daytime-BP significantly and reduced urinary albumin excretion. Our results underline the importance of treatment of OSA in hypertensive patients with impaired renal function.
文摘Introduction: Positive airway pressure (PAP) therapy is the gold-standard for obstructive sleep apnea (OSA) management. While it is known that PAP is efficacious for controlling breathing events during sleep when it is worn at the right pressure for the amount of time prescribed, there is less clear data on how well it improves sleep quality. There are few studies that have examined the effectiveness of PAP therapy on sleep quality. Methods: OSA participants (n = 241) from a larger trial examining a PAP adherence were included. Participants were provided with PAP instruction and followed at 2 months and 4 months. PAP adherence was measured as the number of hours per night at prescribed pressure, an objective measure of treatment adherence. The Pittsburgh Sleep Quality Index (PSQI) was used as the primary measure of sleep quality. Results: The PSQI was significantly correlated with PAP adherence at both the 2-month and 4-month time points, such that lower sleep quality was associated with lower PAP use. This finding held for the sleep disturbance subscale of the PSQI. Over 55% of those using PAP therapy at the 4-month time point continued to report significantly disturbed sleep. Discussion: This study shows that PAP therapy does not appear to improve sleep quality to a degree that would be expected. Over half of those patients using PAP therapy still experienced disturbed sleep. Whether the disturbed sleep is directly attributable to the PAP device itself or to disturbed sleep secondary to uncontrolled OSA when PAP is not worn is worthy of further investigation.
文摘Objective: Research was conducted to examine benefits to using non-invasive ventilation (NIV) or continuous positive airway pressure (CPAP) early in the treatment of respiratory distress caused by pulmonary edema, chronic obstructive pulmonary disease (COPD) and asthma. Limitations to successful NIV and CPAP therapy were evaluated to determine how prolonged initiation of treatment may lead to hypoxemia (decreased oxygen in the blood) and hypercapnia (increased carbon dioxide in the blood) resulting in poor outcomes. Method: Reviews of literature from nursing and allied health data bases (CINAHL and ProQuest) with terms pulmonary edema, positive pressure device and non-invasive ventilation from 2010 to 2014 were used. Studies were conducted in the hospital and prehospital settings. Results: The literature search located 7 articles from CINAHL and 25 articles from ProQuest. A total of 6 of these articles were analyzed. Additional sources of data were obtained from Ignatavicius and Workman (2013) Medical-Surgical Nursing Patient-Centered Collaborative Care 7th edition and American Journal of Nursing (02/2013) Volume 113: 2. Conclusion: All of the articles concluded that early initiation of continuous positive airway pressure ventilations in the short-term was beneficial;however, late initiation of therapy required additional interventions. The studies indicated that early use of positive airway pressure in acute respiratory distress improved breath rate, heart rate and blood pressure. The use of positive airway pressure for respiratory distress may decrease the need for endotracheal intubation.
文摘Background: For patients with obstructive sleep apnea-hypopnea syndrome (OSAHS) and type 2 diabetes mellitus (T2DM), the night sleep interruption and intermittent hypoxia due to apnea or hypopnea may induce glycemic excursions and reduce insulin sensitivity. This study aimed to investigate the effect of continuous positive airway pressure (CPAP) therapy in patients with OSAHS and T2DM. Methods: Continuous glucose monitoring system (CGMS) was used in 40 patients with T2DM and newly diagnosed OSAHS. The measurements were repeated after 30 days of CPAP treatment. Subsequently, insulin sensitivity and glycohemoglobin (HbAlc) were measured and compared to the pretreatment data. Results: After CPAP therapy, the CGMS indicators showed that the 24-h mean blood glucose (MBG) and the night time MBG were significantly reduced (P 〈 0.05 and P = 0.03, respectively). The mean ambulatory glucose excursions (MAGEs) and the mean of daily differences were also significantly reduced (P 〈 0.05 and P = 0.002, respectively) compared to pretreatment levels. During the night, MAGE also significantly decreased (P = 0.049). The differences between the highest and lowest levels of blood glucose over 24 h and during the night were significantly lower than prior to CPAP treatment (P 〈 0.05 and P = 0.024, respectively). The 24 h and night time durations of high blood glucose (〉7.8 mmol/L and 〉 11.1 mmol/L) decreased (P 〈 0.05 and P 〈 0.05, respectively) after the treatment. In addition, HbA 1 c levels were also lower than those before treatment (P 〈 0.05), and the homeostasis model assessment index of insulin resistance was also significantly lower than before CPAP treatment (P = 0.034). Conclusions: CPAP therapy may have a beneficial effect on improving not only blood glucose but also upon insulin sensitivity in T2DM patients with OSAHS. This suggests that CPAP may be an effective treatment for T2DM in addition to intensive diabetes management.
文摘Background Recent research suggested that obstructive sleep apnea syndrome (OSAS) might be independently associated with hypoadiponectinemia, which was linked to some complications of OSAS, such as hypertension, diabetes etc. This study was conducted to investigate the effect of continuous positive airway pressure (CPAP) treatment on changes of both serum adiponectin levels and mean arterial pressure and their possible links in male OSAS patients. Methods Twenty-three adult male patients with moderate-to-severe OSAS but without obesity, coronary heart disease and diabetes were recruited. Their blood samples were collected and morning mean arterial pressure (MAP) was measured before CPAP treatment and on day 3, 7, 14 of CPAP treatment respectively. The serum adiponectin concentration was tested with radioimmunoassay. Results Compared with the serum adiponectin level before CPAP treatment, no significant change was found in OSAS patients on day 3 and day 7 of CPAP treatment (P〉0.05). It was not until day 14 of CPAP treatment did a significant elevation in serum adiponectin level occur (P〈0.01). Meanwhile, the MAP showed no statistically significant difference among its levels before CPAP, on day 3 and day 7 of CPAP treatment (P〉0.05). However, on day 14 of CPAP treatment, a significantly lower MAP than that obtained before treatment was observed (P〈0.05). Conclusions CPAP treatment can gradually reverse hypoadiponectinemia and reduce MAP in OSAS patients. Hypoadiponectinemia might be involved in the pathogenesis of OSAS-mediated hypertension.
基金a grant from the National Natural Science Foundation of China
文摘Background: Current views on continuous positive airway pressure (CPAP) treatment to improve the cognitive deficits of patients with obstructive sleep apnea syndrome (OSAS) are controversial, so we performed a meta-analysis. Methods: A comprehensive literature search was undertaken in PubMed, CINAHL, Medline, Psyclnfo, EMBASE, Cochrane Library, CNKI, WanFang, VIP, and CBMdisc for studies published from June 1971 to July 2014. The outcome measures included neuropsychological tests of the 7 cognitive domains detailed below. Results: After screening the titles and abstracts and thoroughly reading the fuU text, we obtained 13 studies with little risk of bias that incorporated 1744 middle-aged obese participants with mild to severe OSAS. The studies were published from 1994 to 2012. Treatment durations varied from 1 to 24 weeks. The effect sizes of attention, vigilance, processing speed, working memory, memory, verbal fluency, and visuoconstructive skills domains were -0.10 (P = 0.24), -0.12 (P = 0.04), -0.08 (P = 0.16), 0.00 (P = 0.95), -0.04 (P = 0.30), -0.06 (P = 0.34), and -0.01 (P = 0.92), respectively. Conclusions: Cognition partially improved in patients with OSAS after CPAP treatment. The only domain with significant improvement was vigilance. Rigorous randomized controlled trials need to be performed to obtain clear results.
基金This study was supported by-the grants from National Natural Science Foundation of China (No. 30800507 and No. 30770934).
文摘Obstructive sleep apnea (OSA), which is the most common sleep-related breathing disorder and characterized by recurrent collapse of the upper airway, causes repeated arousals from sleep, decreased oxygen saturation of the blood, and excessive daytime sleepiness. Patients with OSA are at increased risk of cardiovascular and cerebrovascular disease,
基金ThisworkwassupportedbytheInternationalCooperationProjectFoundationoftheJiangsuScienceandTechnologyCommittee (No BJ2 0 0 3 0 48)
文摘Background Continuous positive airway pressure (CPAP) treatment has been proven to be effective in improving the symptoms of coexisting coronary heart disease (CHD) in patients with obstructive sleep apnea hypopnea syndrome (OSAHS). However,it is still unclear whether such improvements are linked to changes in vascular endothelial function. This research was carried out to investigate the effects of CPAP treatment on vascular endothelial function in patients with OSAHS and CHD.Methods Thirty-six patients with moderate or severe OSAHS and CHD undergoing three months of CPAP treatment were recruited for this study. The changes in their morning plasma nitric oxide (NO) and endothelin (ET) levels,NO/ET ratio,total ischemic burden (TIB) of the myocardium,apnea hypopnea index (AHI),and minimal and mean pulse oxygen saturation (SpO_2) were compared and analyzed before and during CPAP treatment. Results Compared with the plasma levels of ET [(51.39±11.69) ng/L] and NO [(36.67±11.86) μmol/L],NO/ET (0.71±0.14),AHI (32.4±7.9),minimal SpO_2 [(68.9±11.4)%],and myocardial TIB [(66.29±16.37) mm·min] before treatment,there were significant decreases in ET [(33.41±10.03) ng/L] ( P <0.05),increases in NO [(59.89±10.26) μmol/L] and NO/ET (1.79±0.38) ( P <0.01),decreases in AHI (1.9±0.5),and increases in minimal SpO_2 [(90.6±1.8) %] (all P <0.01) and myocardial TIB [(36.42±10.87) mm·min] ( P <0.05) after three months of CPAP treatment.Conclusion CPAP treatment may play an important role in the improvement and protection of vascular endothelial dysfunction and myocardial ischemia in OSAHS patients with CHD.
文摘Objectives To characterize the prethrombotic state ( PTS) in elderly Chinese patients with obstructive sleep apnea hypopnea syndrome (OSAHS) and the effect of nasal continuous positive airway pressure (nCPAP) ventilation on their PTS.Methods Forty-one elderly patients with moderate and severe OSAHS were enrolled into the OSAHS group and underwent nCPAP treatment. Their blood samples were drawn at 6:00 am and 4:00 pm before and during nCPAP treatment, respectively, to test hemocrit, platelet aggregation (PAG), whole blood viscosity (WBV), plasma fibrinogen (fng), prothrombin time (PT) and activated partial thromboplastin time (APTT). All blood factors were also tested in a control group consisting of 32 healthy elderly Chinese with neither OSAHS nor cerebrocardiac vascular disease.Results In the OSAHS group there was a significantly higher hemocrit, WBV, fng, and a significantly shorter PT and APTT at 6:00 am compared to 4:00 pm before nCPAP treatment, while there was no significant difference among all blood test factors between 6:00 am and 4:00 pm on day 30 of the nCPAP treatment. In the OSAHS group, the hemocrit, WBV, PAG and plasma fng were significantly lower and the PT and APTT were significantly longer at 6:00 am on day 30 of the nCPAP treatment compared to 6:00 am before the nCPAP treatment. A significantly lower hemocrit, but a much longer PT and APTT were observed at 4:00 pm on day 30 of the treatment, compared with 4:00 pm before the treatment. No significant difference among the blood test factors was found between 6:00 am and 4:00 pm blood in the control group or between the control and OSAHS groups after 30 days of nCPAP treatment.Conclusion In elderly Chinese OSAHS patients, PTS could be effectively eliminated by nCPAP treatment.
文摘Background Obesity is a common risk factor for several diseases. Obesity related hormone and increased insulin resistance (IR) may contribute to the effects of obstructive sleep apnoea on cardiovascular consequences. We investigated ghrelin and IR in non-diabetic apnoeic patients with stable coronary heart disease and assessed the effects of continuous positive airway pressure (CPAP). Methods Plasma ghrelin, glucose and insulin were measured in 22 patients with CPAP and 22 matched controls without CPAP at baseline and three months. Indexes including homeostasis model assessment IR (HOMA IR), HOMA S and HOMA β were calculated for the assessment of IR, insulin sensitivity and pancreatic β cell function. Results At three months follow-up, plasma ghrelin levels and HOMA IR in CPAP group were significantly decreased (P=0.002 and 0.046, respectively) while those in control group increased significantly (P=0.012 and 0.009, respectively). Significant moderate correlations were found between ghrelin vs. HOMA IR and ghrelin vs. HOMA S after CPAP, however, for those without CPAP, no significant associations were observed. Conclusions Short-term effective continuous positive airway pressure had a significant effect on lowering plasma ghrelin levels and IR, but not body fat. Further large scale and longer term studies are warranted to corroborate these findings.