期刊文献+
共找到1篇文章
< 1 >
每页显示 20 50 100
The optimal slice thickness of CT in revealing lobulation of malignant solitary pulmonary nodules 被引量:2
1
作者 Shenjiang Li Changcheng Li Xin Wang Debin Liu Wenjie Liang Feng Zhu Yan Zhu Xuefeng Cui Wenjie Bi 《The Chinese-German Journal of Clinical Oncology》 CAS 2011年第10期559-562,共4页
Objective: The aim of this study was to determine an optimal slice thickness that was efficient in revealing Iobulation of malignant solitary pulmonary nodules (SPNs) on multi-slice spiral computed tomography (MSC... Objective: The aim of this study was to determine an optimal slice thickness that was efficient in revealing Iobulation of malignant solitary pulmonary nodules (SPNs) on multi-slice spiral computed tomography (MSCT) images preliminarily. Methods: Fifty patients with malignant SPNs (diameter -〈 3 cm) underwent multidetector-row computed tomography of the chest in a single-breath-hold technique. The raw data were acquired with a collimation of 0.625 mm. Three sets of contiguous images were reconstructed with 1-, 2-, and 5-ram slice thickness, respectively. The Iobulation sign of SPNs on the computed tomography (CT) images presented in 1-, 2-, and 5-ram slice thickness was compared. Using the 1-mm sections as the gold standard, an optimal slice thickness in revealing Iobulation sign of SPNs was determined. Results: The 1-mm-thick images CT revealed 98 Iobulations (25 with chord distance 〈 1 ram; 30 with chord distance 1-2 ram; 43 with chord distance 〉 2 mm) of 45 malignant SPNs. 18 Iobulations with chord distance 〈 1 mm presented in 2-mm-thick sections were as same as those in I-ram-thick sections. Statistically significant difference in Iobulations number was found between that revealed in 2-ram-thick images and that in I-ram-thick images (P = 0.023 〈 0.05). 16 Iobulations with chord distance 〈 1 mm presented in 5-mm-thick sections were as same as that in I-ram-thick sections. There was statistically significant difference in Iobulations number between that revealed in 5-mm-thick images and that in I-ram-thick images (P = 0.004 〈 0.05). The 24 Iobulations with chord distance 1-2 mm presented in 2-ram-thick sections were as same as that in 1-mm-thick sections. No statistically significant difference in Iobulations number were found between that revealed in 2-mm-thick images and that in 1-mm-thick images (P = 0.261 〉 0.05). 13 Iobulations with chord distance 1-2 mm presented in 5-ram-thick sections were as same as that in 1- mm-thick sections. There was statistically significant difference in Iobulations number between that revealed in 5-ram-thick images and that in I-ram-thick images (P = 0.003 〈 0.05). 40 Iobulations with chord distance 〉 2 mm presented in 2-ram-thick sections were as same as that in I-ram-thick sections. No statistically significant difference in Iobulations number was found between that revealed in 2-ram-thick images and that in I-ram-thick images (P = 0.631 〉 0.05). 36 Iobulations with chord distance 〉 2 mm presented in 5-mm-thick sections were as same as that in I-ram-thick sections. There was no statistically significant difference in Iobulations number between that revealed in 5-ram-thick images and that in I-ram-thick images (P = 0.264 〉 0.05). Conclusion: It is suggested that the use of 1-mm slice thickness is suitable in revealing Iobulations with chord distance 〈 1 ram. A 2-mm slice thickness is suggested to be used in revealing Iobulafions with chord distance 1-2 mm and 5-mm slice thickness to be used in revealing Iobulations with chord distance 〉 2 mm. 展开更多
关键词 TOMOGRAPHY X-ray computed coin lesion PULMONARY iobulation
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部