The unintentional islanding of micro-grid may cause negative impacts on distribution loads and distributed generations,so it must be detected within the acceptable duration.In this paper a new islanding detection algo...The unintentional islanding of micro-grid may cause negative impacts on distribution loads and distributed generations,so it must be detected within the acceptable duration.In this paper a new islanding detection algorithm is proposed.This algorithm introduces the frequency feedback method by the reactive power compensation to derive the frequency continuous shift. Accordingly,the islanding can be detected by monitoring the frequency within 0.1 s.The simulation results prove that this algorithm has extremely small non-detection zone,and meanwhile it presents an excellent islanding detection speed as well.展开更多
Micro-grids comprise low voltage distribution systems with distributed energy resources(DERs) and controllable loads which can operate connected to the medium voltage grid or islanded in a controlled coordinated way. ...Micro-grids comprise low voltage distribution systems with distributed energy resources(DERs) and controllable loads which can operate connected to the medium voltage grid or islanded in a controlled coordinated way. This concept aims to move from "connect and forget" philosophy towards a full integration of DERs. Micro-grids can provide numerous economic and environmental benefits for end-customers, utilities and society. However, their implementation poses great technical challenges, such as a new philosophy in design of protection systems. In this work, a micro-grid protection scheme is presented based on positive-sequence component using phasor measurement units(PMUs) and a central protection unit(CPU). The salient feature of the proposed scheme in comparison with the previous works is that it has the ability to protect both radial and looped micro-grids against different types of faults with the capability of single-phase tripping. Furthermore, since the CPU is capable of updating its pickup values(upstream and downstream equivalent positive-sequence impedances of each line) after the first change in the micro-grid configuration(such as transferring from grid-connected to islanded mode and or disconnection of a line, bus, or DER either in grid-connected mode or in islanded mode), it can protect micro-grid against subsequent faults. Finally, in order to verify the effectiveness of the suggested scheme and the CPU, several simulations have been undertaken by using DIg SILENT Power Factory and MATLAB software packages.展开更多
基金National High-Tech R&D Program of China(No.2007AA05Z241).
文摘The unintentional islanding of micro-grid may cause negative impacts on distribution loads and distributed generations,so it must be detected within the acceptable duration.In this paper a new islanding detection algorithm is proposed.This algorithm introduces the frequency feedback method by the reactive power compensation to derive the frequency continuous shift. Accordingly,the islanding can be detected by monitoring the frequency within 0.1 s.The simulation results prove that this algorithm has extremely small non-detection zone,and meanwhile it presents an excellent islanding detection speed as well.
文摘Micro-grids comprise low voltage distribution systems with distributed energy resources(DERs) and controllable loads which can operate connected to the medium voltage grid or islanded in a controlled coordinated way. This concept aims to move from "connect and forget" philosophy towards a full integration of DERs. Micro-grids can provide numerous economic and environmental benefits for end-customers, utilities and society. However, their implementation poses great technical challenges, such as a new philosophy in design of protection systems. In this work, a micro-grid protection scheme is presented based on positive-sequence component using phasor measurement units(PMUs) and a central protection unit(CPU). The salient feature of the proposed scheme in comparison with the previous works is that it has the ability to protect both radial and looped micro-grids against different types of faults with the capability of single-phase tripping. Furthermore, since the CPU is capable of updating its pickup values(upstream and downstream equivalent positive-sequence impedances of each line) after the first change in the micro-grid configuration(such as transferring from grid-connected to islanded mode and or disconnection of a line, bus, or DER either in grid-connected mode or in islanded mode), it can protect micro-grid against subsequent faults. Finally, in order to verify the effectiveness of the suggested scheme and the CPU, several simulations have been undertaken by using DIg SILENT Power Factory and MATLAB software packages.
文摘多微源独立微网中,传统下垂控制的输出频率动态响应速度快,虚拟同步发电机(virtual synchronous generator,VSG)控制可改善频率响应特性,但无法兼顾功率和频率的动态调节性能。针对此问题,提出一种改进的转动惯量自适应控制(improved adaptive control of inertia,IACI)。首先,在同步旋转坐标系下建立VSG数学模型,并分析转动惯量对VSG输出特性的影响;其次,在VSG控制的基础上通过在转动惯量控制中引入频率变化量形成VSG转动惯量自适应控制,并给出频率跟踪系数、转动惯量和阻尼系数等参量的整定方法;最后利用Matlab/Simulink对比VSG控制和IACI控制在VSG并入微网和负载扰动条件下的有功和频率响应曲线,在由两台1k W的VSG组成的独立微网实验平台上进行实验验证,结果表明所提控制策略可避免VSG并入微网过程中的有功振荡,且可以有效优化频率响应曲线。