An accurate and sensitive method for the simultaneous determination of gibberellic acid(GA3), gibberellin A4(GA4) and gibberellin A7(GA7) residues in tomato paste was developed by coupling solid phase extraction...An accurate and sensitive method for the simultaneous determination of gibberellic acid(GA3), gibberellin A4(GA4) and gibberellin A7(GA7) residues in tomato paste was developed by coupling solid phase extraction to high performance liquid chromatography-tandem mass spectrometry(LC-MS/MS) with electrospray ionization based stable isotope dilution analysis(SIDA). The isotope labeled internal standard can compensate for the losses during the extraction and cleanup steps and for discrimination due to ion suppression. After extraction from methanol, hydrophile lipophilic balance(HLB) solid phase extraction(SPE) column was tested for the capacity of the cleanup of the tomato paste in compared with C18 SPE column which is the common way to the detection of GAs, and the former gained better result. Spiked experiments were performed in the non-contaminated tomato pastes and the recoveries of GA3, GA4 and GA7 were 42.6%―75.0% in external standard method(ESM) and 91.1%―103.8% in internal standard method(ISM) respectively. The validities of this method were investigated and good analytical performance for the three GAs was obtained, including low limits of method detection(2 ng/g for GA3 and GA4, 0.3 ng/g for GA7), excellent linear dynamic ranges(5―500 ng/g for GA3 and GA4, 1―100 ng/g for GA7) and good relative standard deviation ranges(4.8%―9.4% for the intra-day test and 3.5%―11.9% for the inter-day test).展开更多
The analysis of hexavalent chromium, Cr(VI), in soil and sediment samples has been predominantly carried out in materials containing elevated levels. Reliable analysis of trace-level of Cr(VI) in sediment samples rema...The analysis of hexavalent chromium, Cr(VI), in soil and sediment samples has been predominantly carried out in materials containing elevated levels. Reliable analysis of trace-level of Cr(VI) in sediment samples remains challenging. Cr(VI) analyses with multipoint calibration and speciated isotope dilution (SID) adapted from U.S. EPA method 6800 were used to measure lower-level Cr(VI) on an ion chromatograph coupled with a tandem mass spectrometer (IC-MS/MS). Lake sediment samples were collected from various locations in Northern Ontario and Cr(VI) was extracted using both alkaline digestion and ethylene diaminetetraacetic acid (EDTA) extraction. Certified reference materials were extracted and analyzed by IC-MS/MS and UV-VIS detection. The SID-MS approach allowed for the quantification of Cr(VI) in samples with concentration levels below 0.5 μg.g-1 wet weight.展开更多
A method for the determination of vitamin A in milk powder was developed by high performance liquid chromatography-isotope dilution mass spectrometry(HPLC-ID MS) and using deuterium-labeled vitamin A as an internal st...A method for the determination of vitamin A in milk powder was developed by high performance liquid chromatography-isotope dilution mass spectrometry(HPLC-ID MS) and using deuterium-labeled vitamin A as an internal standard.RSD of the method was 2.85%.This method was applied in the determination of standard reference material SRM 1849 with satisfactory results.展开更多
采用HRGC/HRMS和同位素稀释定量技术对样品中17种4~8个氯原子取代的二嗯英和呋喃(PCDDs/Fs)与12种共平面多氯联苯(PCBs)定量分析。样品经索式抽提、FMS Power Prep系统净化、浓缩,利用高分辨气相色谱/高分辨质谱联用仪的多离子检...采用HRGC/HRMS和同位素稀释定量技术对样品中17种4~8个氯原子取代的二嗯英和呋喃(PCDDs/Fs)与12种共平面多氯联苯(PCBs)定量分析。样品经索式抽提、FMS Power Prep系统净化、浓缩,利用高分辨气相色谱/高分辨质谱联用仪的多离子检测方式,同位素稀释技术对样品中的目标化合物进行定性和定量。该方法的检出限为pg/g水平。^13同位素内标回收率范围为47%~100%。对3个CRM鱼样中17个PCDDs/Fs和4个PCBs的检测值均在标准定值允许误差范围内。对5个不同的实际样品鱼进行测定表明,样品的回收率在48%~100%之间,回收率的相对标准偏差小于20%;对同一样品进行定量检测的精密度测试结果表明,17种PCDDs/Fs浓度的RSD低于16%,12种PCBs浓度的RSD低于11%。本方法定量分析重现性良好。展开更多
基金Supported by the Project of Chinese Academy of Inspection and Quanrantine(No.2010JK001)the Project of Xinjiang Entry-exit Inspection and Quarantine Bureau, China(No.2010XK0033)
文摘An accurate and sensitive method for the simultaneous determination of gibberellic acid(GA3), gibberellin A4(GA4) and gibberellin A7(GA7) residues in tomato paste was developed by coupling solid phase extraction to high performance liquid chromatography-tandem mass spectrometry(LC-MS/MS) with electrospray ionization based stable isotope dilution analysis(SIDA). The isotope labeled internal standard can compensate for the losses during the extraction and cleanup steps and for discrimination due to ion suppression. After extraction from methanol, hydrophile lipophilic balance(HLB) solid phase extraction(SPE) column was tested for the capacity of the cleanup of the tomato paste in compared with C18 SPE column which is the common way to the detection of GAs, and the former gained better result. Spiked experiments were performed in the non-contaminated tomato pastes and the recoveries of GA3, GA4 and GA7 were 42.6%―75.0% in external standard method(ESM) and 91.1%―103.8% in internal standard method(ISM) respectively. The validities of this method were investigated and good analytical performance for the three GAs was obtained, including low limits of method detection(2 ng/g for GA3 and GA4, 0.3 ng/g for GA7), excellent linear dynamic ranges(5―500 ng/g for GA3 and GA4, 1―100 ng/g for GA7) and good relative standard deviation ranges(4.8%―9.4% for the intra-day test and 3.5%―11.9% for the inter-day test).
文摘The analysis of hexavalent chromium, Cr(VI), in soil and sediment samples has been predominantly carried out in materials containing elevated levels. Reliable analysis of trace-level of Cr(VI) in sediment samples remains challenging. Cr(VI) analyses with multipoint calibration and speciated isotope dilution (SID) adapted from U.S. EPA method 6800 were used to measure lower-level Cr(VI) on an ion chromatograph coupled with a tandem mass spectrometer (IC-MS/MS). Lake sediment samples were collected from various locations in Northern Ontario and Cr(VI) was extracted using both alkaline digestion and ethylene diaminetetraacetic acid (EDTA) extraction. Certified reference materials were extracted and analyzed by IC-MS/MS and UV-VIS detection. The SID-MS approach allowed for the quantification of Cr(VI) in samples with concentration levels below 0.5 μg.g-1 wet weight.
文摘提出了同位素稀释-液相色谱-串联质谱法测定鱼、虾、蟹、贝4类水产品中甲霜灵残留量的方法。取样品(5±0.05)g,加入10 ng的内标甲霜灵-d 6,静置10 min,用10 mL含1%(体积分数)乙酸的乙腈溶液涡旋混合、离心。取上清液,于45℃氮吹至0.5 mL以下,加入7.5 mL 20%(体积分数,下同)乙腈溶液混匀,用7.5 mL正己烷去脂,Agela Cleanert S C_(18)固相萃取柱富集净化。所得溶液于45℃氮吹至干,用1 mL 20%乙腈溶液复溶,混匀后过0.22μm针式水相尼龙滤膜,滤液收集至进样小瓶中。以SHISEIDO CAPCELL PAK C_(18)色谱柱为固定相,以不同体积比的0.1%(体积分数)甲酸溶液和乙腈的混合液为流动相进行梯度洗脱,内标法定量。结果表明,甲霜灵标准曲线的线性范围为1.0~100.0μg·L^(-1),检出限(3S/N)为0.5μg·kg^(-1)。以不同品种水产品为空白基质,在1.0,2.0,10.0μg·kg^(-1)等3个浓度水平下,甲霜灵的回收率为93.8%~105%,测定值的相对标准偏差(n=6)均小于13%。
文摘A method for the determination of vitamin A in milk powder was developed by high performance liquid chromatography-isotope dilution mass spectrometry(HPLC-ID MS) and using deuterium-labeled vitamin A as an internal standard.RSD of the method was 2.85%.This method was applied in the determination of standard reference material SRM 1849 with satisfactory results.
文摘采用HRGC/HRMS和同位素稀释定量技术对样品中17种4~8个氯原子取代的二嗯英和呋喃(PCDDs/Fs)与12种共平面多氯联苯(PCBs)定量分析。样品经索式抽提、FMS Power Prep系统净化、浓缩,利用高分辨气相色谱/高分辨质谱联用仪的多离子检测方式,同位素稀释技术对样品中的目标化合物进行定性和定量。该方法的检出限为pg/g水平。^13同位素内标回收率范围为47%~100%。对3个CRM鱼样中17个PCDDs/Fs和4个PCBs的检测值均在标准定值允许误差范围内。对5个不同的实际样品鱼进行测定表明,样品的回收率在48%~100%之间,回收率的相对标准偏差小于20%;对同一样品进行定量检测的精密度测试结果表明,17种PCDDs/Fs浓度的RSD低于16%,12种PCBs浓度的RSD低于11%。本方法定量分析重现性良好。