An accurate and sensitive method for the simultaneous determination of gibberellic acid(GA3), gibberellin A4(GA4) and gibberellin A7(GA7) residues in tomato paste was developed by coupling solid phase extraction...An accurate and sensitive method for the simultaneous determination of gibberellic acid(GA3), gibberellin A4(GA4) and gibberellin A7(GA7) residues in tomato paste was developed by coupling solid phase extraction to high performance liquid chromatography-tandem mass spectrometry(LC-MS/MS) with electrospray ionization based stable isotope dilution analysis(SIDA). The isotope labeled internal standard can compensate for the losses during the extraction and cleanup steps and for discrimination due to ion suppression. After extraction from methanol, hydrophile lipophilic balance(HLB) solid phase extraction(SPE) column was tested for the capacity of the cleanup of the tomato paste in compared with C18 SPE column which is the common way to the detection of GAs, and the former gained better result. Spiked experiments were performed in the non-contaminated tomato pastes and the recoveries of GA3, GA4 and GA7 were 42.6%―75.0% in external standard method(ESM) and 91.1%―103.8% in internal standard method(ISM) respectively. The validities of this method were investigated and good analytical performance for the three GAs was obtained, including low limits of method detection(2 ng/g for GA3 and GA4, 0.3 ng/g for GA7), excellent linear dynamic ranges(5―500 ng/g for GA3 and GA4, 1―100 ng/g for GA7) and good relative standard deviation ranges(4.8%―9.4% for the intra-day test and 3.5%―11.9% for the inter-day test).展开更多
The concept of metrological traceability in laboratory medicine has increasingly received considerable recognition worldwide.The Consultative Committee for Amount of Substance (CCQM) which concerned international comp...The concept of metrological traceability in laboratory medicine has increasingly received considerable recognition worldwide.The Consultative Committee for Amount of Substance (CCQM) which concerned international comparisons and establishment of international equivalence between national laboratories had organized international comparison CCQM-P77a: determination of serum cortisol in 2006.National Institute of Metrology (NIM) took part in the comparison as the representative of China and received good performance according to the results published by CCQM.展开更多
Phenylalanine in serum was determined by HPLC isotope dilution mass spectrometry method with D8 labeled phenylalanine as internal standard.Phenylalanine and its isotope labeled analogue were monitored at the transitio...Phenylalanine in serum was determined by HPLC isotope dilution mass spectrometry method with D8 labeled phenylalanine as internal standard.Phenylalanine and its isotope labeled analogue were monitored at the transitions m/z=166→120 and 172→126 in multiple reaction monitoring (MRM) mode,respectively,which effectively eliminated the matrix effect.The RSD for 5 repeats measurement of the same sample was 0.5%.Uncertainty was evaluated,which showed the main uncertainty was from the purity assessment of phenylalanine reference material and the variation of method.The presented method can be applied into value assessment of reference material of phenylalanine in serum,and it can be also used for traceability establishment of the measurement of phenylalanine in serum.展开更多
基金Supported by the Project of Chinese Academy of Inspection and Quanrantine(No.2010JK001)the Project of Xinjiang Entry-exit Inspection and Quarantine Bureau, China(No.2010XK0033)
文摘An accurate and sensitive method for the simultaneous determination of gibberellic acid(GA3), gibberellin A4(GA4) and gibberellin A7(GA7) residues in tomato paste was developed by coupling solid phase extraction to high performance liquid chromatography-tandem mass spectrometry(LC-MS/MS) with electrospray ionization based stable isotope dilution analysis(SIDA). The isotope labeled internal standard can compensate for the losses during the extraction and cleanup steps and for discrimination due to ion suppression. After extraction from methanol, hydrophile lipophilic balance(HLB) solid phase extraction(SPE) column was tested for the capacity of the cleanup of the tomato paste in compared with C18 SPE column which is the common way to the detection of GAs, and the former gained better result. Spiked experiments were performed in the non-contaminated tomato pastes and the recoveries of GA3, GA4 and GA7 were 42.6%―75.0% in external standard method(ESM) and 91.1%―103.8% in internal standard method(ISM) respectively. The validities of this method were investigated and good analytical performance for the three GAs was obtained, including low limits of method detection(2 ng/g for GA3 and GA4, 0.3 ng/g for GA7), excellent linear dynamic ranges(5―500 ng/g for GA3 and GA4, 1―100 ng/g for GA7) and good relative standard deviation ranges(4.8%―9.4% for the intra-day test and 3.5%―11.9% for the inter-day test).
文摘The concept of metrological traceability in laboratory medicine has increasingly received considerable recognition worldwide.The Consultative Committee for Amount of Substance (CCQM) which concerned international comparisons and establishment of international equivalence between national laboratories had organized international comparison CCQM-P77a: determination of serum cortisol in 2006.National Institute of Metrology (NIM) took part in the comparison as the representative of China and received good performance according to the results published by CCQM.
文摘Phenylalanine in serum was determined by HPLC isotope dilution mass spectrometry method with D8 labeled phenylalanine as internal standard.Phenylalanine and its isotope labeled analogue were monitored at the transitions m/z=166→120 and 172→126 in multiple reaction monitoring (MRM) mode,respectively,which effectively eliminated the matrix effect.The RSD for 5 repeats measurement of the same sample was 0.5%.Uncertainty was evaluated,which showed the main uncertainty was from the purity assessment of phenylalanine reference material and the variation of method.The presented method can be applied into value assessment of reference material of phenylalanine in serum,and it can be also used for traceability establishment of the measurement of phenylalanine in serum.