期刊文献+
共找到5,554篇文章
< 1 2 250 >
每页显示 20 50 100
Optimization of tracheoesophageal fistula model established with Tshaped magnet system based on magnetic compression technique
1
作者 Miao-Miao Zhang Jian-Qi Mao +5 位作者 Lin-Xin Shen Ai-Hua Shi Xin Lyu Jia Ma Yi Lyu Xiao-Peng Yan 《World Journal of Gastroenterology》 SCIE CAS 2024年第16期2272-2280,共9页
BACKGROUND The magnetic compression technique has been used to establish an animal model of tracheoesophageal fistula(TEF),but the commonly shaped magnets present limitations of poor homogeneity of TEF and poor model ... BACKGROUND The magnetic compression technique has been used to establish an animal model of tracheoesophageal fistula(TEF),but the commonly shaped magnets present limitations of poor homogeneity of TEF and poor model control.We designed a Tshaped magnet system to overcome these problems and verified its effectiveness via animal experiments.AIM To investigate the effectiveness of a T-shaped magnet system for establishing a TEF model in beagle dogs.METHODS Twelve beagles were randomly assigned to groups in which magnets of the Tshaped scheme(study group,n=6)or normal magnets(control group,n=6)were implanted into the trachea and esophagus separately under gastroscopy.Operation time,operation success rate,and accidental injury were recorded.After operation,the presence and timing of cough and the time of magnet shedding were observed.Dogs in the control group were euthanized after X-ray and gastroscopy to confirm establishment of TEFs after coughing,and gross specimens of TEFs were obtained.Dogs in the study group were euthanized after X-ray and gastroscopy 2 wk after surgery,and gross specimens were obtained.Fistula size was measured in all animals,and then harvested fistula specimens were examined by hematoxylin and eosin(HE)and Masson trichrome staining.RESULTS The operation success rate was 100%for both groups.Operation time did not differ between the study group(5.25 min±1.29 min)and the control group(4.75 min±1.70 min;P=0.331).No bleeding,perforation,or unplanned magnet attraction occurred in any animal during the operation.In the early postoperative period,all dogs ate freely and were generally in good condition.Dogs in the control group had severe cough after drinking water at 6-9 d after surgery.X-ray indicated that the magnets had entered the stomach,and gastroscopy showed TEF formation.Gross specimens of TEFs from the control group showed the formation of fistulas with a diameter of 4.94 mm±1.29 mm(range,3.52-6.56 mm).HE and Masson trichrome staining showed scar tissue formation and hierarchical structural disorder at the fistulas.Dogs in the study group did not exhibit obvious coughing after surgery.X-ray examination 2 wk after surgery indicated fixed magnet positioning,and gastroscopy showed no change in magnet positioning.The magnets were removed using a snare under endoscopy,and TEF was observed.Gross specimens showed well-formed fistulas with a diameter of 6.11 mm±0.16 mm(range,5.92-6.36 mm),which exceeded that in the control group(P<0.001).Scar formation was observed on the internal surface of fistulas by HE and Masson trichrome staining,and the structure was more regular than that in the control group.CONCLUSION Use of the modified T-shaped magnet scheme is safe and feasible for establishing TEF and can achieve a more stable and uniform fistula size compared with ordinary magnets.Most importantly,this model offers better controllability,which improves the flexibility of follow-up studies. 展开更多
关键词 magnetic surgery magnetic compression technique Tracheoesophageal fistula magnet Animal model Beagles
下载PDF
Modeling and Validation of Diamagnetic Rotor Levitated by Permanent Magnetics
2
作者 Yuanping Xu Yue Zhang +1 位作者 Jin Zhou Chaowu Jin 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2024年第3期224-235,共12页
As an innovative,low-power consuming,and low-stiffness suspension approach,the diamagnetic levitation technique has attracted considerable interest because of its potential applicability in miniaturized mechanical sys... As an innovative,low-power consuming,and low-stiffness suspension approach,the diamagnetic levitation technique has attracted considerable interest because of its potential applicability in miniaturized mechanical systems.The foundation of a diamagnetic levitation system is mathematical modeling,which is essential for operating performance optimization and stability prediction.However,few studies on systematic mathematical modeling have been reported.In this study,a systematic mathematical model for a disc-shaped diamagnetically levitated rotor on a permanent magnet array is proposed.Based on the proposed model,the magnetic field distribution characteristics,diamagnetic levitation force characteristics(i.e.,levitation height and stiffness),and optimized theoretical conditions for realizing stable levitation are determined.Experiments are conducted to verify the feasibility of the proposed mathematical model.Theoretical predictions and experimental results indicate that increasing the levitation height enlarges the stable region.Moreover,with a further increase in the rotor radius,the stable regions of the rotor gradually diminish and even vanish.Thus,when the levitation height is fixed,a moderate rotor radius permits stable levitation.This study proposes a mathematical modeling method for a diamagnetic levitation system that has potential applications in miniaturized mechanical systems. 展开更多
关键词 Diamagnetic levitation magnetic levitation ROTOR modelING VALIDATION STABILITY
下载PDF
Predicting distant metastasis in nasopharyngeal carcinoma using gradient boosting tree model based on detailed magnetic resonance imaging reports
3
作者 Yu-Liang Zhu Xin-Lei Deng +7 位作者 Xu-Cheng Zhang Li Tian Chun-Yan Cui Feng Lei Gui-Qiong Xu Hao-Jiang Li Li-Zhi Liu Hua-Li Ma 《World Journal of Radiology》 2024年第6期203-210,共8页
BACKGROUND Development of distant metastasis(DM)is a major concern during treatment of nasopharyngeal carcinoma(NPC).However,studies have demonstrated im-proved distant control and survival in patients with advanced N... BACKGROUND Development of distant metastasis(DM)is a major concern during treatment of nasopharyngeal carcinoma(NPC).However,studies have demonstrated im-proved distant control and survival in patients with advanced NPC with the addition of chemotherapy to concomitant chemoradiotherapy.Therefore,precise prediction of metastasis in patients with NPC is crucial.AIM To develop a predictive model for metastasis in NPC using detailed magnetic resonance imaging(MRI)reports.METHODS This retrospective study included 792 patients with non-distant metastatic NPC.A total of 469 imaging variables were obtained from detailed MRI reports.Data were stratified and randomly split into training(50%)and testing sets.Gradient boosting tree(GBT)models were built and used to select variables for predicting DM.A full model comprising all variables and a reduced model with the top-five variables were built.Model performance was assessed by area under the curve(AUC).RESULTS Among the 792 patients,94 developed DM during follow-up.The number of metastatic cervical nodes(30.9%),tumor invasion in the posterior half of the nasal cavity(9.7%),two sides of the pharyngeal recess(6.2%),tubal torus(3.3%),and single side of the parapharyngeal space(2.7%)were the top-five contributors for predicting DM,based on their relative importance in GBT models.The testing AUC of the full model was 0.75(95%confidence interval[CI]:0.69-0.82).The testing AUC of the reduced model was 0.75(95%CI:0.68-0.82).For the whole dataset,the full(AUC=0.76,95%CI:0.72-0.82)and reduced models(AUC=0.76,95%CI:0.71-0.81)outperformed the tumor node-staging system(AUC=0.67,95%CI:0.61-0.73).CONCLUSION The GBT model outperformed the tumor node-staging system in predicting metastasis in NPC.The number of metastatic cervical nodes was identified as the principal contributing variable. 展开更多
关键词 Nasopharyngeal carcinoma Distant metastasis Machine learning Detailed magnetic resonance imaging report Gradient boosting tree model
下载PDF
Numerical Analysis on Magnetic-induced Shear Modulus of Magnetorheological Elastomers Based on Multi-chain Model 被引量:4
4
作者 朱应顺 龚兴龙 +2 位作者 党辉 张先舟 张培强 《Chinese Journal of Chemical Physics》 SCIE CAS CSCD 北大核心 2006年第2期126-130,共5页
Based on the magnetic interaction energy, using derivative of the magnetic energy density, a model is proposed to compute the magnetic-induced shear modulus of magnetorheological elastomers. Taking into account the in... Based on the magnetic interaction energy, using derivative of the magnetic energy density, a model is proposed to compute the magnetic-induced shear modulus of magnetorheological elastomers. Taking into account the influences of particles in the same chain and the particles in all adjacent chains, the traditional magnetic dipole model of the magnetorheological elastomers is modified. The influence of the ratio of the distance etween adjacent chains to the distance between adjacent particles in a chain on the magnetic induced shear odulus is quantitatively studied. When the ratio is large, the multi-chain model is compatible with the single chain model, but when the ratio is small, the difference of the two models is significant and can not be neglected. Making certain the size of the columns and the distance between adjacent columns, after constructing the computational model of BCT structures, the mechanical property of the magnetorheological elastomers composed of columnar structures is analyzed. Results show that, conventional point dipole model has overrated the magnetic-induced shear modulus of the magnetorheological elastomers. From the point of increasing the magnetic-induced shear modulus, when the particle volume fraction is small, the chain-like structure exhibits better result than the columnar structure, but when the particle volume fraction is large,the columnar structure will be better. 展开更多
关键词 magnetorheological elastomers Shear modulus magnetic dipole model
下载PDF
Joint inversion of gravity and magnetic data for a two-layer model 被引量:1
5
作者 江凡 吴健生 王家林 《Applied Geophysics》 SCIE CSCD 2008年第4期331-339,共9页
Based on the synchronous joint gravity and magnetic inversion of single interface by Pilkington and the need of revealing Cenozoic and crystalline basement thickness in the new round of oil-gas exploration, we propose... Based on the synchronous joint gravity and magnetic inversion of single interface by Pilkington and the need of revealing Cenozoic and crystalline basement thickness in the new round of oil-gas exploration, we propose a joint gravity and magnetic inversion methodfor two-layer models by concentrating on the relationship between the change of thicknessI and position of the middle layer and anomaly and discuss the effects of the key parameters. Model tests and application to field data show the validity of this method. 展开更多
关键词 Two-layer model joint inversion of gravity and magnetic data Cenozoic andcrystalline basement
下载PDF
Simulation of the SMILE Soft X-ray Imager response to a southward interplanetary magnetic field turning 被引量:1
6
作者 Andrey Samsonov Graziella Branduardi-Raymont +3 位作者 Steven Sembay Andrew Read David Sibeck Lutz Rastaetter 《Earth and Planetary Physics》 EI CSCD 2024年第1期39-46,共8页
The Solar wind Magnetosphere Ionosphere Link Explorer(SMILE)Soft X-ray Imager(SXI)will shine a spotlight on magnetopause dynamics during magnetic reconnection.We simulate an event with a southward interplanetary magne... The Solar wind Magnetosphere Ionosphere Link Explorer(SMILE)Soft X-ray Imager(SXI)will shine a spotlight on magnetopause dynamics during magnetic reconnection.We simulate an event with a southward interplanetary magnetic field turning and produce SXI count maps with a 5-minute integration time.By making assumptions about the magnetopause shape,we find the magnetopause standoff distance from the count maps and compare it with the one obtained directly from the magnetohydrodynamic(MHD)simulation.The root mean square deviations between the reconstructed and MHD standoff distances do not exceed 0.2 RE(Earth radius)and the maximal difference equals 0.24 RE during the 25-minute interval around the southward turning. 展开更多
关键词 magnetOPAUSE magnetic reconnection solar wind charge exchange southward interplanetary magnetic field numerical modeling Solar wind magnetosphere Ionosphere Link Explorer(SMILE) Soft X-ray Imager
下载PDF
Novel magnetic compression technique for establishment of a canine model of tracheoesophageal fistula 被引量:23
7
作者 Yi Gao Rong-Qian Wu +1 位作者 Yi Lv Xiao-Peng Yan 《World Journal of Gastroenterology》 SCIE CAS 2019年第30期4213-4221,共9页
BACKGROUND Clinically,tracheoesophageal fistula(TEF)is lack of effective surgical strategies.One reason is due to the lack of appropriate animal models of acquired TEF,which is usually complex and difficult.Recently,t... BACKGROUND Clinically,tracheoesophageal fistula(TEF)is lack of effective surgical strategies.One reason is due to the lack of appropriate animal models of acquired TEF,which is usually complex and difficult.Recently,the magnetic compression technique has been applied for digestive tract anastomosis or vascular anastomosis in animals.In this study,an animal model of TEF in dogs was developed by using the magnetic compression technique,hoping to provide a new method for mimicking TEF.AIM To establish a TEF model in dogs by using the magnetic compression technique.METHODS Six male beagles were used as models with two Nd-Fe-B permanent magnets for TEF.The parent magnet and the daughter magnet were placed in the cervical esophagus and trachea,respectively.The anterior wall of the esophagus and the posterior wall of the trachea were compressed when the two magnets coupled.After 4-6 d,the necrotic tissue between the two magnets fell off and the parent and daughter magnets disengaged from the target location,leaving a fistula.Gastroscopy/bronchoscopy,upper gastrointestinal contrast study,and histological analysis were performed.RESULTS The establishment of the TEF model in all six beagles was successful.The average time of magnet placement was 4.33±1.11 min(range,3-7 min).Mean time for the magnets to disengage from the target location was 4.67±0.75 d(range,4-6 d).TEFs were observed by gastroscopy/bronchoscopy and esophageal angiography.The gross anatomical structure of the esophagus and the trachea was in good condition.There was no esophageal mucosa or pseudostratified ciliated columnar epithelium at the site of the fistula according to histological analysis.CONCLUSION It is simple,feasible,and minimally invasive to use the magnetic compression technique for the establishment of the TEF model in dogs. 展开更多
关键词 magnetic compression TECHNIQUE Tracheoesophageal FISTULA BEAGLE ANIMAL model
下载PDF
Target distribution of magnetic albumin nanoparticles containing adriamycin in transplanted rat liver cancer model 被引量:9
8
《Hepatobiliary & Pancreatic Diseases International》 SCIE CAS 2004年第3期365-368,共4页
关键词 TRANSPLANTED liver CANCER model magnetic ALBUMIN nanoparticles magnetic target therapy
下载PDF
Mathematical model and magnetic-control mechanism of the stability of rotating spray transfer 被引量:14
9
作者 殷树言 陈树君 +1 位作者 王军 徐鲁宁 《China Welding》 EI CAS 2003年第1期57-61,共5页
To realize stable rotating spray transfer in the region of high constant current is the key of realizing high deposition rate MAG welding process without helium in shielding gas and extending the welding current rang... To realize stable rotating spray transfer in the region of high constant current is the key of realizing high deposition rate MAG welding process without helium in shielding gas and extending the welding current range of traditional MAG welding process. In this paper, the magnetic control mechanism of the rotating spray transfer is stated and mathematical model is given. Theoretic basis is established, which implements high deposition rate MAG welding process with magnetic control instead of helium in shielding gas. 展开更多
关键词 magnetic control rotating spray transfer high deposition rates MAG welding process mathematical model
下载PDF
Critical behaviours and magnetic properties of three-dimensional bond and anisotropy dilution Blume-Capel model in the presence of an applied field 被引量:5
10
作者 晏世雷 朱海霞 《Chinese Physics B》 SCIE EI CAS CSCD 2006年第12期3026-3032,共7页
This paper studies the critical behaviours and magnetic properties of three-dimensional bond and anisotropy dilution Blume-Capel model (BCM) in the presence of an applied field within the effective field theory. The... This paper studies the critical behaviours and magnetic properties of three-dimensional bond and anisotropy dilution Blume-Capel model (BCM) in the presence of an applied field within the effective field theory. The trajectory of tricritical point, reentrant transitions and degenerate patterns of anisotropy are obtained both for the bond and the anisotropy dilutions. The global phase diagrams demonstrate unusually reentrant phenomena. The temperature dependences of magnetization curves undergo remarkable spin glass behaviour at low temperatures, and transform from ferromagnetism to paramagnetism at high temperature in applied fields. Temperature dependence of magnetic susceptibility curve is in qualitative agreement with experimental result. 展开更多
关键词 critical behaviours and magnetic properties Blume-Capel model bond and anisotropy dilutions applied field
下载PDF
Cardiac magnetic source imaging based on current multipole model 被引量:3
11
作者 唐发宽 王倩 +3 位作者 华宁 陆宏 唐雪正 马平 《Chinese Physics B》 SCIE EI CAS CSCD 2011年第1期258-266,共9页
It is widely accepted that the heart current source can be reduced into a current multipole. By adopting three linear inverse methods, the cardiac magnetic imaging is achieved in this article based on the current mult... It is widely accepted that the heart current source can be reduced into a current multipole. By adopting three linear inverse methods, the cardiac magnetic imaging is achieved in this article based on the current multipole model expanded to the first order terms. This magnetic imaging is realized in a reconstruction plane in the centre of human heart, where the current dipole array is employed to represent realistic cardiac current distribution. The current multipole as testing source generates magnetic fields in the measuring plane, serving as inputs of cardiac magnetic inverse problem. In the heart-torso model constructed by boundary element method, the current multipole magnetic field distribution is compared with that in the homogeneous infinite space, and also with the single current dipole magnetic field distribution. Then the minimum-norm least-squares (MNLS) method, the optimal weighted pseudoinverse method (OWPIM), and the optimal constrained linear inverse method (OCLIM) are selected as the algorithms for inverse computation based on current multipole model innovatively, and the imaging effects of these three inverse methods are compared. Besides, two reconstructing parameters, residual and mean residual, are also discussed, and their trends under MNLS, OWPIM and OCLIM each as a function of SNR are obtained and compared. 展开更多
关键词 cardiac magnetic imaging current multipole heart-torso model inverse method
下载PDF
Pairwise thermal entanglement in a three-qubit Heisenberg XX model with a nonuniform magnetic field and Dzyaloshinski-Moriya interaction 被引量:3
12
作者 任金忠 邵晓强 +1 位作者 张寿 Yeon Kyu-Hwang 《Chinese Physics B》 SCIE EI CAS CSCD 2010年第10期74-80,共7页
Pairwise thermal entanglement in a three-qubit Heisenberg XX model is investigated when a nonuniform mag- netic field and the Dzyaloshinski-Moriya interaction are included. We find that the nonuniform magnetic field a... Pairwise thermal entanglement in a three-qubit Heisenberg XX model is investigated when a nonuniform mag- netic field and the Dzyaloshinski-Moriya interaction are included. We find that the nonuniform magnetic field and Dzyaloshinski-Moriya interaction are the more efficient control parameters for the increase of entanglement and critical temperature. For both the nearest neighbour sites and the next nearest neighbour sites, the magnetic field can induce entanglement to a certain extent and the Dzyaloshinski-Moriya interaction can enhance the entanglement to a stable value. The steady value of the nearest neighbour site entanglement C12 is larger than the next nearest neighbour site entanglement C13. An interesting phenomenon is that the entanglement curve of C12 appears a peak value when the Dzyaloshinski-Moriya interaction is considered in a nonuniform magnetic field. 展开更多
关键词 thermal entanglement nonuniform magnetic field Dzyaloshinski-Moriya interaction Heisenberg model
下载PDF
EVALUATION OF CIRRHOTIC LIVER WITH PERFUSION-WEIGHTED MAGNETIC RESONANCE IMAGING:A PRELIMINARY EXPERIMENTAL STUDY IN ANIMAL MODELS WITH HALF-LIVER CIRRHOSIS 被引量:6
13
作者 Zheng-han Yang Xiao-hua Ye +5 位作者 Ye Tan Min Zhang Ming-zhu Zhou Jing-xia Xie Min Chen Cheng Zhou 《Chinese Medical Sciences Journal》 CAS CSCD 2006年第4期252-257,共6页
Objective To investigate the role of peffusion-weighted magnetic resonance imaging (MRI) in evaluation of cirrhotic fiver. Methods With a 4F catheter, 1% diluted carbon tetrachloride ( 1 ml/kg) was selectively in... Objective To investigate the role of peffusion-weighted magnetic resonance imaging (MRI) in evaluation of cirrhotic fiver. Methods With a 4F catheter, 1% diluted carbon tetrachloride ( 1 ml/kg) was selectively injected into fight or left hepatic artery of 12 dogs fortnightly. The half fiver into which carbon tetrachloride was injected was called as study side (SS), while the other half fiver without carbon tetrachloride injection was called as study control side (SCS). Conventional and peffusion-weighted MRI were performed in every 4 weeks. Via a 4F catheter, 5ml gadolinium diethylentriamine pentaaceti acid (Gd-DTPA) dilution was injected into superior mesenteric artery at the 5th scan. The signal intensity-thne curves of SS, SCS, and portal vein were completed in MR workstation. The maximal relative signal increase ( MRSI), peak time ( tp), and slope of the curves were measured. Results On conventional MR images, no abnormalities of externality and signal intensity were observed in both SS and SCS of fiver at each stage. The mean tp, MP, SI, and slope of intensity-time curves in normal fiver were 10. 56 seconds, 1.01, and 10. 23 arbitrary unit (au)/s, respectively. Three parameters of curves didn't show obvious change in SCS of fiver at every stage. Abnormal perfusion curves occurred in SS of fiver at the 12th week after the 1st injection. The abnormality of perfusion curve in SS was more and more serious as the times of injection increased. The mean tp, IVlRSI, and slope intensity-time curves in SS of fiver were 19.45 seconds, 0. 43, and 3. 60 au/s respectively at the 24th week. Conclusion Perfusion-weighted imaging can potentially provide information about portal peffusion of hepatic parenchyma, and to some degree, reflect the severity of cirrhosis. 展开更多
关键词 liver cirrhosis animal model magnetic resonance imaging perfusion imaging
下载PDF
Theoretical characterization of the temperature-dependent saturation magnetization of magnetic metallic materials
14
作者 吴金龙 董攀 +6 位作者 贺屹 马艳丽 李梓源 姚沁远 邱俊 麻建坐 李卫国 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第7期577-585,共9页
Based on the force-heat equivalence energy density principle,a theoretical model for magnetic metallic materials is developed,which characterizes the temperature-dependent magnetic anisotropy energy by considering the... Based on the force-heat equivalence energy density principle,a theoretical model for magnetic metallic materials is developed,which characterizes the temperature-dependent magnetic anisotropy energy by considering the equivalent relationship between magnetic anisotropy energy and heat energy;then the relationship between the magnetic anisotropy constant and saturation magnetization is considered.Finally,we formulate a temperature-dependent model for saturation magnetization,revealing the inherent relationship between temperature and saturation magnetization.Our model predicts the saturation magnetization for nine different magnetic metallic materials at different temperatures,exhibiting satisfactory agreement with experimental data.Additionally,the experimental data used as reference points are at or near room temperature.Compared to other phenomenological theoretical models,this model is considerably more accessible than the data required at 0 K.The index included in our model is set to a constant value,which is equal to 10/3 for materials other than Fe,Co,and Ni.For transition metals(Fe,Co,and Ni in this paper),the index is 6 in the range of 0 K to 0.65T_(cr)(T_(cr) is the critical temperature),and 3 in the range of 0.65T_(cr) to T_(cr),unlike other models where the adjustable parameters vary according to each material.In addition,our model provides a new way to design and evaluate magnetic metallic materials with superior magnetic properties over a wide range of temperatures. 展开更多
关键词 magnetic metallic materials temperature dependent saturation magnetization modelING
下载PDF
Crustal structure of the western Indian shield: Model based on regional gravity and magnetic data 被引量:2
15
作者 Suman Kilaru Bandaru Karunakar Goud Vijay Kumar Rao 《Geoscience Frontiers》 SCIE CAS CSCD 2013年第6期717-728,共12页
Regional surface gravity data and global satellite magnetic data have been utilized to generate a preliminary model of the crustal structure along a southwest-northeast profile (Gadra-Fatehpur) through western Rajas... Regional surface gravity data and global satellite magnetic data have been utilized to generate a preliminary model of the crustal structure along a southwest-northeast profile (Gadra-Fatehpur) through western Rajasthan.The study area represents the western part of the Indian continental landmass which has undergone several major episodes of repeated subduction/collision,plume traces and rifting from Archaean to recent times.The temporal and spatial relationship between the various geotectonic provinces is quite complex,thereby limiting the emergence of a suitable crustal structure model for this region.Exposures of the Malani Igneous Suite (MIS),a product of bimodal volcanism (~780 Ma),and considered to be the third largest felsic magmatic province of the world,is evident along the profile and also to the southwest of the study area.The easternmost part of the profile is close to the DAFB (Delhi Aravalli Fold Belt),a Proterozoic orogenic belt.This study probes the geometry of the different crustal units in terms of density and susceptibility variations in order to decipher the imprints of the major tectonic processes the region has undergone.In order to decipher the crustal geometry of the Gadra-Fatehpur profile,two NW-SE gravity and magnetic profile vertical sections (A-A' in the south and B-B' in the north) are modelled on the basis of the constraints provided from previous seismic models.The crustal model of the Gadra-Fatehpur profile is composed of alluvium,Tertiary sediments,MIS,Marwar Supergroup,low-density layers (LDLs) and the middle-lower crustal layers,with a distinct change in configuration from the southwest to northeast.The Moho dips from SW to NE,the MIS in the SW gives way to the thick pile of the Marwar Supergroup to the NE.The evolution of MIS has been suggested to have occurred as a consequence of delamination of the upper mantle.LDLs are incorporated in Gadra-Fatehpur model.In the SW,LDL (2550 kg/m3) lies below the MIS in the NE,another LDL (2604 kg/m3) is depicted below the mid-crustal layer. 展开更多
关键词 Western Indian shield Gravity and magnetic modelling MIS DELAMINATION Bimodal volcanism
下载PDF
Immobilized laccase on magnetic nanoparticles for enhanced lignin model compounds degradation 被引量:4
16
作者 Xinyan Chen Bin He +2 位作者 Mi Feng Dingwei Zhao Jian Sun 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2020年第8期2152-2159,共8页
As a natural aromatic polymer,lignin has great potential but limited industrial application due to its complex chemical structure.Among strategies for lignin conversion,biodegradation has attracted promising interest ... As a natural aromatic polymer,lignin has great potential but limited industrial application due to its complex chemical structure.Among strategies for lignin conversion,biodegradation has attracted promising interest recently in term of efficiency,selectivity and mild condition.In order to overcome the issues of poor stability and non-reusability of enzyme in the biodegradation of lignin,this work explored a protocol of immobilized laccase on magnetic nanoparticles(MNPs)with rough surfaces for enhanced lignin model compounds degradation.Scanning electron microscope with energy dispersive spectrometer(SEM-EDS),flourier transformation infrared spectroscopy(FTIR)and thermal gravimetric analysis(TGA)were utilized to characterize the immobilization of laccase.The results showed a maximum activity recovery of 64.7%towards laccase when it was incubated with MNPs and glutaraldehyde(GA)with concentrations of 6 mg·ml^-1and 7.5 mg·ml^-1for 5 h,respectively.The immobilized laccase showed improved thermal stability and pH tolerance compared with free laccase,and remained more than 80%of its initial activity after 20 days of storage at 4℃.In addition,about 40%residual activity of the laccase remained after 8 times cycles.Gas chromatography–mass spectrometry(GC–MS)was utilized to characterize the products of lignin model compound degradation and activation,and the efficiency of immobilized laccase was calculated to be 1–5 times that of free laccase.It was proposed that the synergistic effect between MNPs and laccase displays an important role in the enhancement of stability and activity in lignin model compound biodegradation. 展开更多
关键词 LACCASE IMMOBILIZATION magnetic nanoparticles Lignin model compounds DEGRADATION
下载PDF
Preliminary geological interpretation of long-wavelength magnetic anomalies over China and surrounding regions
17
作者 Jie Wang YanYan Yang +4 位作者 ZhiMa Zeren Jian Wang Xin Wang YuXin Luo XuHui Shen 《Earth and Planetary Physics》 EI CAS CSCD 2024年第3期445-458,共14页
Long-wavelength(>500 km)magnetic anomalies originating in the lithosphere were first found in satellite magnetic surveys.Compared to the striking magnetic anomalies around the world,the long-wavelength magnetic ano... Long-wavelength(>500 km)magnetic anomalies originating in the lithosphere were first found in satellite magnetic surveys.Compared to the striking magnetic anomalies around the world,the long-wavelength magnetic anomalies in China and surrounding regions are relatively weak.Specialized research on each of these anomalies has been quite inadequate;their geological origins remain unclear,in particular their connection to tectonic activity in the Chinese and surrounding regions.We focus on six magnetic high anomalies over the(1)Tarim Basin,(2)Sichuan Basin(3)Great Xing’an Range,(4)Barmer Basin,(5)Central Myanmar Basin,and(6)Sunda and Banda Arcs,and a striking magnetic low anomaly along the southern part of the Himalayan-Tibetan Plateau.We have analyzed their geological origins by reviewing related research and by detailed comparison with geological results.The tectonic backgrounds for these anomalies belong to two cases:either ancient basin basement,or subduction-collision zone.However,the geological origins of large-scale regional magnetic anomalies are always subject to dispute,mainly because of limited surface exposure of sources,later tectonic destruction,and superposition of multi-phase events. 展开更多
关键词 long-wavelength magnetic anomaly lithospheric magnetic anomaly lithospheric magnetic field model satellite magnetic survey CSES
下载PDF
Evaluation of a rabbit rectal VX2 carcinoma model using computed tomography and magnetic resonance imaging 被引量:9
18
作者 Xin-Mei Liang Guang-Yu Tang +1 位作者 Ying-Sheng Cheng Bi Zhou 《World Journal of Gastroenterology》 SCIE CAS CSCD 2009年第17期2139-2144,共6页
AIM: To establish a rabbit rectal VX2 carcinoma model for the study of rectal carcinoma.METHODS: A suspension of VX2 cells was injected into the rectum wall under the guidance of X-ray fluoroscopy. Computed tomograp... AIM: To establish a rabbit rectal VX2 carcinoma model for the study of rectal carcinoma.METHODS: A suspension of VX2 cells was injected into the rectum wall under the guidance of X-ray fluoroscopy. Computed tomography (CT) and magnetic resonance imaging (MRI) were used to observe tumorgrowth and metastasis at different phases. Pathological changes and spontaneous survival time of the rabbits were recorded.RESULTS: Two weeks after VX2 cell implantation, the tumor diameter ranged 4.1-5.8 mm and the success implantation rate was 81.8%. CT scanning showed low-density loci of the tumor in the rectum wail, while enhanced CT scanning demonstrated a symmetrical intensification in tumor loci. MRI scanning showed alow signal of the tumor on T1-weighted imaging anda high signal of the tumor on T2-weighted imaging.Both types of signals were intensified with enhanced MRI. Metastases to the liver and lung could beobserved 6 wk after VX2 cell implantation, and a largearea of necrosis appeared in the primary tumor. The spontaneous survival time of rabbits with cachexia and multiple organ failure was about 7 wk after VX2 cell implantation.CONCLUSION: The rabbit rectal VX2 carcinoma model we established has a high stability, and can be used in the study of rectal carcinoma. 展开更多
关键词 Rectal carcinoma Animal model Rabbit VX2 Computed tomography magnetic resonance imaging
下载PDF
Model acupuncture point:Bone marrow-derived stromal stem cells are moved by a weak electromagnetic field 被引量:2
19
作者 Artem N Emelyanov Marina V Borisova Vera V Kiryanova 《World Journal of Stem Cells》 SCIE CAS 2016年第10期342-354,共13页
AIM To show the existence of a structural formative role of magnetic fields(MFs) with respect to biological objects by using our proposed model of an acupoint.METHODS We introduced a magnetised 10-100 μT metal rod(ne... AIM To show the existence of a structural formative role of magnetic fields(MFs) with respect to biological objects by using our proposed model of an acupoint.METHODS We introduced a magnetised 10-100 μT metal rod(needle) into culture dishes with a negatively charged working surface and observed during 24 h how cells were arranged by MFs and by electrical fields(EFs) when attached. Rat and human bone marrow-derived stromal stem cells(r BMSCs and h BMSCs), human nonadherent mononuclear blood cells, NCTCs and A172 cells, and Escherichia coli(E. coli) were evaluated. The dish containing BMSCs was defined as the model of an acupoint. r BMSCs proliferative activity affected by the needle was investigated. For investigating electromagnetic field structures, we used the gas discharge visualisation(GDV) method.RESULTS During 24 h of incubation in 50-mm culture dishes, BMSCs or the nonadherent cells accumulated into a central heap in each dish. BMSCs formed a torus(central ring) with an inner diameter of approximately10 mm only upon the introduction of the needle in the centre of the dish. The cells did not show these effects in 35- or 90-mm culture dishes or hydrophobic dishes or rectangular cuvettes. NCTCs and A172 cells showed unstable the effects and only up to two weeks after thawing. Moreover, we observed that the appearance of these effects depended on the season. In winter, BMSCs showed no the effects. GDV experiments revealed that the resonant annular illumination gradually formed from 10 to 18-20 s in polar solutions with and without cell suspension of BMSCs, NCTCs and E. coli when using circular 50-mm dishes, stimulation at 115 V and switching of the electrode poles at 1 kH z. All these data demonstrate the resonant nature of the central ring. Significant influence of MFs on the rB MSC proliferation rate was not observed.CONCLUSION BMSCs can be moved by MFs when in the presence of a constant EF and MF, when the cells are in the responsive functional state, and when there is a resonant relationship between them. 展开更多
关键词 Stem cell MOVEMENT magnetic targeting Acupuncture model ACUPOINT Frizzled-related protein Biology resonance CYTOPLASM MOVEMENT GLYCOCALYX
下载PDF
Metal magnetic memory field characterization at early fatigue damage based on modified Jiles-Atherton model 被引量:6
20
作者 徐明秀 徐敏强 +1 位作者 李建伟 邢海燕 《Journal of Central South University》 SCIE EI CAS 2012年第6期1488-1496,共9页
In order to propel the development of metal magnetic memory (MMM) technique in fatigue damage detection, the Jiles-Atherton model (J-A model) was modified to describe MMM mechanism in elastic stress stage. A serie... In order to propel the development of metal magnetic memory (MMM) technique in fatigue damage detection, the Jiles-Atherton model (J-A model) was modified to describe MMM mechanism in elastic stress stage. A series of rotating bending fatigue experiments were conducted to study the stress-magnetization relationship and verify the correctness of modified J-A model. In MMM detection, the magnetization of material irreversibly approaches to the local equilibrium state Mo instead of global equilibrium state M^n under cyclic stress, and the M0-a curves are loops around the Mar,-a curve. The modified J-A model is constructed by replacing M~ in J-A model with M0, and it can describe the magnetomechanical effect well at low external magnetic field. In the rotating bending fatigue experiments, the MMM field distribution in normal direction around cylinder specimen is similar to the stress distribution, and the calculation result of model coincides with experiment result after some necessary modifications. The MMM field variation with time at a certain point in fatigue process is divided into three stages with the variation of stable stress-stain hysteresis loop, and the calculation results of model can explain not only the three stages of MMM field changes, but also the different change laws when the applied magnetic field and initial magnetic field are different. The MMM field distribution in normal direction along specimen axis reflects stress concentration effect at artificial defect, and the magnetic signal fluctuates around the defect at late fatigue stage. The calculation results coincide with the initial MMM principle and can explain signal fluctuates around the defect. The modified J-A model can explain experiment results well, and it is fit for MMM field characterization. 展开更多
关键词 metal magnetic memory Jiles-Atherton model rotating bending fatigue magnetomechanical effect local equilibriumstate
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部