Circular impinging jet, which is widely used in accelerated control cooling (ACC) equipment to accelerate the cooling of hot rolled plates, is subject to breakup, and may result in undesirable cooling effect. Theref...Circular impinging jet, which is widely used in accelerated control cooling (ACC) equipment to accelerate the cooling of hot rolled plates, is subject to breakup, and may result in undesirable cooling effect. Therefore, the jet breakup should be avoided as possible in industrial production. The objective of this study is to find the relation of the processing parameters of the ACC equipment versus the breakup length of jet with weaker turbulence. To obtain quantitative findings, not only relative experimental study but also numerical simulation was carded out. For a weaker turbulent water jet, the breakup length increases with the increase of jet diameter, as well as with the jet velocity; jet diameter has a significant effect on the breakup length for a certain flow rate when compared with jet velocity; finally a suggested correlation of the jet breakup length versus jet Weber number is presented in this study.展开更多
Correlations for the extension of a water vapor jet injected in a liquid pool were historically proposed considering the mass flux (kg/m2/s) as a constant. The results were satisfactory, however adjusting the values b...Correlations for the extension of a water vapor jet injected in a liquid pool were historically proposed considering the mass flux (kg/m2/s) as a constant. The results were satisfactory, however adjusting the values by linear regression. Although, it presents the following drawbacks: 1) the formulation is only valid for the specific range of data for what it was created;2) it does not allow the analytical evaluation of the heat transfer coefficient from the extension equation. This paper proposes a new formulation for the calculation of the mass flux, in such a way to remove both of these drawbacks.展开更多
文摘Circular impinging jet, which is widely used in accelerated control cooling (ACC) equipment to accelerate the cooling of hot rolled plates, is subject to breakup, and may result in undesirable cooling effect. Therefore, the jet breakup should be avoided as possible in industrial production. The objective of this study is to find the relation of the processing parameters of the ACC equipment versus the breakup length of jet with weaker turbulence. To obtain quantitative findings, not only relative experimental study but also numerical simulation was carded out. For a weaker turbulent water jet, the breakup length increases with the increase of jet diameter, as well as with the jet velocity; jet diameter has a significant effect on the breakup length for a certain flow rate when compared with jet velocity; finally a suggested correlation of the jet breakup length versus jet Weber number is presented in this study.
文摘Correlations for the extension of a water vapor jet injected in a liquid pool were historically proposed considering the mass flux (kg/m2/s) as a constant. The results were satisfactory, however adjusting the values by linear regression. Although, it presents the following drawbacks: 1) the formulation is only valid for the specific range of data for what it was created;2) it does not allow the analytical evaluation of the heat transfer coefficient from the extension equation. This paper proposes a new formulation for the calculation of the mass flux, in such a way to remove both of these drawbacks.