A simple, reliable and efficient assay for quantitative analysis of a novel Kv7/KCNQ/M-channel opener QO58-lysin in rat plasma was developed using high-performance liquid chromatography(HPLC) with UV detection. Sepa...A simple, reliable and efficient assay for quantitative analysis of a novel Kv7/KCNQ/M-channel opener QO58-lysin in rat plasma was developed using high-performance liquid chromatography(HPLC) with UV detection. Separation of compound QO58-lysin from plasma was achieved using a reverse-phase C18 column with a mobile phase of 0.2 M ammonium acetate in H2O–acetonitrile(40:60, v/v) with nitrendipine used as an internal standard(IS). The retention times of QO58-lysin and the IS in rat plasma were 3.8 and 5.4 min, respectively. Calibration curve was linear ranging from 0.1 to 120 μg/mL with correlation coefficient(r2) of 0.9996. The lower limit of quantification was 0.1 μg/mL. Accuracy, precision, recovery as well as stability were all within acceptable criteria according to Food and Drug Administration(FDA) guidelines. This validated assay was successfully applied to determine the pharmacokinetics of QO58-lysin administered intravenously(10 mg/kg) in SD rats. The distribution and elimination half-life of QO58-lysin in plasma was(0.25±0.16) h and(2.15±0.12) h, respectively.展开更多
基金Ministry of Science and Technology of China(Grant No.2013ZX09103001-015 and 2013CB531300)the National Science Foundation of China(Grant No.81221002)
文摘A simple, reliable and efficient assay for quantitative analysis of a novel Kv7/KCNQ/M-channel opener QO58-lysin in rat plasma was developed using high-performance liquid chromatography(HPLC) with UV detection. Separation of compound QO58-lysin from plasma was achieved using a reverse-phase C18 column with a mobile phase of 0.2 M ammonium acetate in H2O–acetonitrile(40:60, v/v) with nitrendipine used as an internal standard(IS). The retention times of QO58-lysin and the IS in rat plasma were 3.8 and 5.4 min, respectively. Calibration curve was linear ranging from 0.1 to 120 μg/mL with correlation coefficient(r2) of 0.9996. The lower limit of quantification was 0.1 μg/mL. Accuracy, precision, recovery as well as stability were all within acceptable criteria according to Food and Drug Administration(FDA) guidelines. This validated assay was successfully applied to determine the pharmacokinetics of QO58-lysin administered intravenously(10 mg/kg) in SD rats. The distribution and elimination half-life of QO58-lysin in plasma was(0.25±0.16) h and(2.15±0.12) h, respectively.